The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: a comparison of serum, synovial fluid, albumin, EDTA, and water.

Physical wear of orthopedic implants is inevitable. CoCr alloy samples, typically used in joint reconstruction, corrode rapidly after removal of the protective oxide layer. The behavior of CoCr pellets immersed in human serum, foetal bovine serum (FBS), synovial fluid, albumin in phosphate-buffered saline (PBS), EDTA in PBS, and water were studied using X-ray Photoelectron Spectroscopy (XPS) and Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS). The difference in the corrosive nature of human serum, water, albumin in PBS and synovial fluid after 5 days of immersion was highlighted by the oxide layer, which was respectively 15, 3.5, 1.5, and 1.5 nm thick. The thickness of an additional calcium phosphate deposit from human serum and synovial fluid was 40 and 2 nm, respectively. Co and Cr ions migrated from the bulk metal surface and were trapped in this deposit by the phosphate anion. This may account for the composition of wear debris from CoCr orthopedic implants, which is known to consist predominantly of hydroxy-phosphate compounds. Known components of synovial fluid including proteoglycans, pyrophosphates, phospholipids, lubricin, and superficial zone protein (SZP), have been identified as possible causes for the lack of significant calcium phosphate deposition in this environment. Circulation of these compounds around the whole implant may inhibit calcium phosphate deposition.

Albumins↗

The practical limitations of resurfacing hip arthroplasty.

Resurfacing hip arthroplasty has recently experienced a resurgence in popularity, associated with an unprecedented amount of coverage in the media. This article assesses what proportion of a consecutive series of young adults presenting for total hip arthroplasty would have been suitable for resurfacing arthroplasty. Retrospective review of the preoperative radiographs was performed, with templating for the resurfacing prostheses. The hips were divided into those appropriate and those inappropriate for the procedure, and those in whom the procedure would be technically challenging. Sixty-one hips in 57 patients were reviewed, with ages ranging from 17 to 49 years. Twenty-eight hips were assessed as suitable, 26 as unsuitable, and 7 as technically challenging. Reasons for unsuitability included collapse and/or cystic degeneration of the femoral head.

Adolescent↗

Clinical experience with metal-on-metal total joint replacements: indications and results.

Survivorship of total joint arthroplasty depends on the durability of fixation and durability of articulation. The metal-on-polyethylene articular couple has been the most widely used. Polyethylene wear (and the associated cytochemical events that culminate in osteolysis) has been identified as a major factor adversely influencing the durability of joint replacement. This stimulated the orthopaedic community to explore the possibility of using alternative bearings with lower wear rates. Hard-on-hard bearings have been shown to be associated with reduced wear. Metal-on-metal bearings have wear rates that are 20-100 times lower than metal on conventional polyethylene. However, patients with metal-on-metal articulations have increased levels of cobalt and chromium in the serum and urine, and this has raised concerns about toxicity, mutagenesis, and hypersensitivity. At this stage there is no epidemiological evidence to suggest that the risk of carcinogenesis is anything more than theoretical. Successful long-term results have been reported with the cast cobalt-chromium metal-on-metal couples of the mid-1960s. Tissues retrieved at revision of these implants did not show the giant-cell inflammatory response associated with polyethylene particles. Several researchers have reported excellent mid-term results with the current generation of high-precision metal-on-metal bearings.

Biocompatible Materials↗

Numerical predictions of the thermal behaviour and resultant effects of grouting cements while setting prosthetic components in bone.

Acrylic cements are commonly used to attach prosthetic components in joint replacement surgery. The cements set in short periods of time by a complex polymerization of initially liquid monomer compounds into solid structures with accompanying significant heat release. Two main problems arise from this form of fixation: the first is the potential damage caused by the temperature excursion, and the second is incomplete reaction leaving active monomer compounds, which can potentially be slowly released into the patient. This paper presents a numerical model predicting the temperature-time history in an idealized prosthetic-cement-bone system. Using polymerization kinetics equations from the literature, the degree of polymerization is predicted, which is found to be very dependent on the thermal history of the setting process. Using medical literature, predictions for the degree of thermal bone necrosis are also made. The model is used to identify the critical parameters controlling thermal and unreacted monomer distributions.

Bone Cements↗

Femoral cementing techniques: current trends in the UK.

INTRODUCTION: The results of a survey conducted amongst hip surgeons in Great Britain on the use of bone cement and femoral cementing techniques are reported. MATERIALS AND METHODS: A postal questionnaire was sent out to the members of the British Orthopaedic Association for their opinion on cement usage and femoral cementing techniques in primary hip arthroplasty. RESULTS: A majority of surgeons use high viscosity cement (82%) and cement containing antibiotics (77%). Almost a fifth of the respondents were unaware of the place of storage of the cement and of the ambient theatre temperature. Over two-thirds experienced inconsistencies in the handling of cement and attributed this to inconsistent theatre temperature (40%) and storage temperature (14%). A majority of the surgeons followed the 'modern' femoral cementing technique of vacuum mixing (94%), plugging the femoral canal (98%), pulsed lavage (87%), retrograde cement introduction (95%), use of stem centralisers (62%) and cement pressurisation. Four-fifths of the surgeons used time as a guide for cement and stem insertion rather than consistency of the cement. CONCLUSIONS: Though most of the surgeons follow contemporary cementing techniques, it appears that inconsistency of the working properties of the cement is a major impediment. Many surgeons are also unaware of the variables that can influence polymerisation and working time of the cement.

Anti-Bacterial Agents↗

An in-vitro investigation into the cement pressurization achieved during insertion of four different femoral stems.

Adequate cement pressurization during stem insertion improves the interdigitation of cement into bone. This increases the strength of the cement-bone interface, thus contributing to the reduction of the incidence of aseptic loosening, the commonest cause of revision surgery. This in-vitro study compared the cement pressurization achieved during insertion of four different stems of equivalent sizes: the Elite Plus (DePuy, UK), C-Stem (DePuy, UK), Exeter (Stryker, USA), and CPS-Plus (Plus Orthopedics, Switzerland). The maximum pressures attained at the time of stem insertion were recorded at proximal, mid and distal stem levels. The Elite Plus generated significantly higher distal pressures than the other stems. The CPS-Plus generated significantly greater proximal cement pressures than the Elite Plus, C-Stem, and Exeter prostheses. The triple taper of the C-Stem increased the cement pressurization medial to the stem. The stem shape and the presence or absence of a proximal stem centralizer affect cement pressurization. The presence of a proximal stem centralizer, a large stem volume, and a lateral-medial taper are all factors associated with increased cement pressurization during stem insertion.

Adhesiveness↗

Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty.

Previous research has shown an increase in chromosomal aberrations in patients with worn implants. The type of aberration depended on the type of metal alloy in the prosthesis. We have investigated the metal-specific difference in the level of DNA damage (DNA stand breaks and alkali labile sites) induced by culturing human fibroblasts in synovial fluid retrieved at revision arthroplasty. All six samples from revision cobalt-chromium metal-on-metal and four of six samples from cobalt-chromium metal-on-polyethylene prostheses caused DNA damage. By contrast, none of six samples from revision stainless-steel metal-on-polyethylene prostheses caused significant damage. Samples of cobalt-chromium alloy left to corrode in phosphate-buffered saline also caused DNA damage and this depended on a synergistic effect between the cobalt and chromium ions. Our results further emphasise that epidemiological studies of orthopaedic implants should take account of the type of metal alloy used.

Aged↗

Revision of an acetabular liner has a high risk of dislocation.

Polyethylene liners of modular acetabular components wear sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of revision. We prospectively followed up 1126 Harris-Galante I metal-backed, uncemented components for between nine and 19 years. We found 38 (3.4%) liners of 1126 acetabular components wore and required revision. These revisions were then followed up for a mean of 4.8 years. The rate of dislocation was 28.9%. Nine of the dislocations occurred once and two were recurrent. The overall secondary revision rate was three of 38 total hip replacements (7.9%) at a mean follow-up of 4.8 years. This gives a 92.1% survivorship (35 of 38) at under five years. In isolated revision of a liner, we had a complication rate of 23% (three of 13). In revision of a liner combined with revision of the femoral stem, there was a complication rate of 48% (12 of 25). We discuss possible reasons for the high dislocation rates. Leaving the well-fixed acetabular shell in situ leads to an increased risk of instability. However, this needs to be balanced against the otherwise low complication rate for revision of the liner. Patients should be consented accordingly.

Arthroplasty, Replacement, Hip↗

The compatibility of ceramic bone graft substitutes as allograft extenders for use in impaction grafting of the femur.

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures.

Absorptiometry, Photon↗

Ten-year results of a press-fit, porous-coated acetabular component.

We retrospectively reviewed, ten years after surgery, 100 consecutive total hip replacements in which the Duraloc 300 cup had been used. Post-operative radiographs were analysed for placement of the cup and interface gaps and follow-up radiographs for lucent lines, osteolysis, wear and migration. All the components were found to be stable with no evidence of loosening. The mean rate of wear was 0.12 mm/year. Three hips developed acetabular osteolysis at the level of the apex hole. Two have successfully undergone bone grafting without removal of the implants and one patient is awaiting surgery. The Duraloc 300 cup has a survival of 100% at ten years with no aseptic loosening and a low incidence of pelvic osteolysis.

Acetabulum↗

An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements.

BACKGROUND: Metal-on-metal bearing surfaces have been reintroduced for use during total hip replacement. To assess tissue reactions to various types of articulations, we studied the histological appearance of periprosthetic tissues retrieved from around metal-on-metal and metal-on-polyethylene total hip replacements and compared these findings with the appearance of control tissues retrieved at the time of primary arthroplasty. METHODS: Periprosthetic tissues were obtained at the time of revision of twenty-five cobalt chromium-on-cobalt chromium, nine cobalt chromium-on-polyethylene, and ten titanium-on-polyethylene total hip arthroplasties. Control tissues were obtained from nine osteoarthritic hips at the time of primary total hip arthroplasty. Each tissue sample was processed for routine histological analysis, and sections were stained with hematoxylin and eosin. Quantitative stereological analysis was performed with use of light microscopy. RESULTS: Tissue samples obtained from hips with metal-on-metal implants displayed a pattern of well-demarcated tissue layers. A prominent feature, seen in seventeen of twenty-five tissue samples, was a pattern of perivascular infiltration of lymphocytes. In ten of the tissue samples obtained from hips with metal-on-metal prostheses, there was also an accumulation of plasma cells in association with macrophages that contained metallic wear-debris particles. The surfaces of tissues obtained from hips with metal-on-metal prostheses were more ulcerated than those obtained from hips with other types of implants, particularly in the region immediately superficial to areas of perivascular lymphocytic infiltration. The lymphocytic infiltration was more pronounced in samples obtained at the time of revision because of aseptic failure than in samples retrieved at the time of autopsy or during arthrotomy for reasons other than aseptic failure. Total-joint-replacement and surface-replacement designs of metal-on-metal prostheses were associated with similar results. Tissue samples obtained from hips with metal-on-polyethylene implants showed far less surface ulceration, much less distinction between tissue layers, no pattern of lymphocytic infiltration, and no plasma cells. The inflammation was predominantly histiocytic. Tissues retrieved from hips undergoing primary joint replacement showed dense scar tissue and minimal inflammation. CONCLUSIONS AND CLINICAL RELEVANCE: The pattern and type of inflammation seen in periprosthetic tissues obtained from hips with metal-on-metal and metal-on-polyethylene implants are very different. At the present time, we do not know the prevalence or clinical implications of these histologic findings, but we suggest that they may represent a novel mode of failure for some metal-on-metal joint replacements.

Biocompatible Materials↗

Outcome assessment following total hip replacement.

Outcome assessment after hip anthroplasty is relevant both to in-depth research of specific procedures and to monitoring standards of practice. Instruments of outcome assessment should be fast, easy to use, reliable, specific to the question being asked, cost-effective, and applicable. Increasing evidence exists that patient-based outcome measures are more reliable than those based on clinicians' scores. This article reviews the types of instruments that are available and offers guidance about the outcome measures that are most approprate for orthopedic surgeons.

Arthroplasty, Replacement, Hip↗

Fracture of a Y-TZP ceramic femoral head. Analysis of a fault.

We studied factors contributing to the initiation of fracture and failure of a zirconia ceramic femoral head. The materials retrieved during a revision total hip replacement were submitted to either visual, stereomicroscopic and scanning electron microscopy (SEM) or SEM and energy-dispersive X-ray analysis. X-ray diffraction was performed in order to investigate the extent of tetragonal to monoclinic phase transition. Histological examination was performed on the periprosthetic tissues. The results showed that failure was due to the propagation during clinical use of defects which may have been introduced into the material during the processing of the ceramic, rather than those intrinsic to zirconia. The literature relating to previous failures of zirconia components is reviewed.

Ceramics↗

Glass ionomer as an expander of allograft in revision arthroplasty of the hip.

The use of glass ionomer as a bone graft expander was investigated in an in vivo model of revision hip arthroplasty. Bone grafts of pure allograft and allograft + glass ionomer particles in a 50:50 by weight mixture were implanted in an ovine hemi-arthroplasty model. Post-operative assessments of locomotor function, radiographic appearance and quantitative changes in mineralisation around the graft were made at 2, 4 and 6 months. Post-mortem assessments of radiographic and histologic appearance of the grafts were made at 6 months. No significant differences were noted in any of the measured or assessed parameters between the two graft types. The glass ionomer particles seemed to be well tolerated within the matrix of new bone, smaller sized particles appearing to be better incorporated than larger ones. The use of particles of glass ionomer as a bone graft expander, in this in vivo model of revision hip arthroplasty, would therefore appear to offer no detriment in performance over pure allograft in the short to medium term.

Acrylic Resins↗

Biocompatibility: a biomechanical and biological concept in total hip replacement.

The insertion of any implant or prosthesis into bone usually changes the biomechanical environment and, thus, alters the stresses and strains applied to the bone. Both bone overload and excessive stress protection can result in bone resorption. The material and geometry of any implant should be designed to avoid excessive flexural mismatch. Incompatibility of materials may result in interface and mechanical failure, with the consequent generation of particulate debris, subsequent osteolysis and implant failure. Particulate debris can be generated from articulating surfaces and from any other modular or fixation interface. Larger particles are associated with a foreign body giant cell reaction. Polyethylene particles in the size range of 0.5 to 10 microm excite a cytochemical reaction that culminates in osteolysis. The precise pathogenesis of osteolysis has not been characterised, but it is probable that different pathogenetic mechanisms are involved in the different radiological types of osteolysis. A large number of very small metallic particles are released from metal-on-metal couples. These may cause mutagenic damage (chromatid breaks, chromosome translocations, aneuploidy, etc.). In defining implant biocompatibility it is essential to consider the biological response both to an altered mechanical environment and to the liberation of particulate debris.

Arthroplasty, Replacement, Hip↗