Search PubMed⌕ Search

Biomedical subjects

I Cornelese-ten Velde

Publications and source records attributed to I Cornelese-ten Velde.

6 recordsLinked to original sources

Reflection contrast microscopy: The bridge between light and electron microscopy.

Reflection contrast microscopy (RCM) is a light microscopic method to image cells at high definition and enhanced sensitivity compared to conventional bright-field microscopy. RCM images have very high contrast, which makes them easily applicable for digital image analysis. Because ultrathin sections are mostly used in this method, RCM also functions by bridging light with electron microscopy: the combination of ultrastructural with histochemical studies. RCM can also replace electron microscopy for rapid and simple screening of large quantities of samples for immunocytochemical staining. Special attention is paid to small biological objects, which have to be processed for RCM. If you encounter the limits of brightfield microscopy, in resolution, sensitivity or handling of the specimen, RCM will be a feasible option. Reflection contrast microscopy methods use only slightly adjusted electron microscopy methods for specimen preparation. Therefore, many familiar techniques for ultrathin specimen preparation can be applied. It is essential that only refractive index differences exist in those areas that are of interest and that the further specimen is as optically homogenic as possible, with a refractive index as close to that of glass as possible. Therefore, plastic embedding is recommended.

Animals↗

Effects of acetone, methanol, or paraformaldehyde on cellular structure, visualized by reflection contrast microscopy and transmission and scanning electron microscopy.

The authors recently showed variable subcellular immunoreactivity of the Bcl-2 and Bax proteins after fixation of cell monolayers with acetone, methanol, or paraformaldehyde (PF) followed by methanol (PF/methanol). Here, the authors demonstrate by reflection contrast microscopy and transmission electron microscopy that acetone or methanol fixation result in complete loss of integrity of intracellular structures in contrast with PF or glutaraldehyde fixation. Scanning electron microscopy revealed poor preservation of plasma membrane integrity after fixation in acetone or methanol. Fixation with PF before methanol reduced damage to intracellular and plasma membranes. In addition, Western blot analysis demonstrated loss of Bcl-2 and Bax protein during acetone or methanol fixation, whereas PF fixation before methanol permeabilization markedly reduced this loss. For studies on the intracellular localization of soluble or unknown types of antigen, the authors discourage the use of acetone and methanol as single fixatives.

Acetone↗

Reflection contrast microscopy of ultrathin sections in immunocytochemical localization studies: a versatile technique bridging electron microscopy with light microscopy.

Reflection contrast microscopy (RCM) of ultrathin sections was recently introduced as a sensitive technique for visualization with enhanced definition in immunogold histochemistry. Experience of using RCM as a major tool in immunocytochemical research in different fields is summarized, e.g. oncology, nephrology and embryology. The sensitive visualization of immunocytochemical labels, gold particles or peroxidase-diaminobenzidine deposits in or on ultrathin sections, by RCM instead of electron microscopy is demonstrated. RCM of ultrathin sections is an adequate light microscopical alternative for immunoelectron microscopy, since an overview of both label and tissue is obtained with a high image definition and high contrast of label. In the studies presented, RCM is shown to provide a better gradation in staining intensity and staining pattern than other light microscopical methods. Moreover, a precise localization of multiple labels is obtained with this method. Besides the applications shown, ultrathin section visualization by RCM is very useful for correlative light- and electron microscopical studies of fine structures. Commercially available fluorescence microscopes can be adapted for proper RCM functioning; an adaptation scheme and list of microscopes tested is provided.

Animals↗

New sensitive light microscopical detection of colloidal gold on ultrathin sections by reflection contrast microscopy. Combination of reflection contrast and electron microscopy in post-embedding immunogold histochemistry.

One simple post-embedding method for combined light- and electron microscopy is presented. Different types of antigens in normal rat and mouse kidneys as well as in tissues from cases of experimental induced nephritis were stained after Lowicryl K4M embedding by an immunogold (silver) method. The (silver-enhanced) gold particles were visualized by light microscopy, e.g. bright-field (BFM)- and reflection contrast (RCM) microscopy, as well as by electron microscopy. The potentials of RCM visualization in this field were investigated, resulting in the successful detection of colloidal gold (15 nm) particles, or silver enhanced gold particles, on ultrathin sections. Furthermore, an increased detection sensitivity of RCM compared with BFM together with an increase in the sensitivity of the immunostaining by RCM visualization was found. The different ways to use RCM, alone or in combination with bright-field- or phase contrast microscopy for visualization of plastic sections varying in thickness, type of plastic and staining, are discussed.

Animals↗

Improved detection and quantification of the (immuno) peroxidase product using reflection contrast microscopy.

Reflection contrast microscopy (RCM) is a sensitive tool to detect minor amounts of precipitated diaminobenzidine (DABox) in immunoperoxidase stained specimens. One of the main issues in immunocytochemistry is the ongoing need for more sensitive and quantitative techniques. Therefore we applied RCM, using a new simple model system, to methods previously described for increased sensitivity in immunocytochemistry with bright field microscopy. Addition of imidazole was found the most sensitive method and addition of Nickel and Cobalt ions gave the most enhanced colour intensity. Variation of the enzyme reaction parameters yielded a continuous increase in reflection with time. This was then discussed in view of other model studies of peroxidase kinetics. A quantitative relationship between the amount of peroxidase and the reflection of DABox was observed, indicating that quantitative immunoperoxidase studies with RCM are feasible. In situ hybridization (ISH) was then used as a useful biological model for RCM to test the optimal conditions for DAB staining found in the model system (high concentrations of DAB and peroxidase and 2 h incubation time). There was no background staining in the model system, also after prolonged incubation time. The ISH experiments showed that the contrast (ratio) between specific signal and chromosome background did not increase in time, whereas only the use of high avPO concentrations yielded the highest contrast.

3,3'-Diaminobenzidine↗

Reflection contrast microscopy. Visualization of (peroxidase-generated) diaminobenzidine polymer products and its underlying optical phenomena.

Reflection contrast microscopy (RCM) has proven to be a useful tool for the study of living cells (Ploem 1975). Due to the effective suppression of aspecific reflected light by polarization optics combined with a quarter lambda plate at the front lens of the objective, low intensity reflection signals originating from minor amounts of precipitated diaminobenzidine (DABox) in immunocytochemically stained specimens, can be made visible. RCM has been successfully applied in demonstrating single copy nucleic acid sequences using in situ hybridization procedures (Landegent et al. 1984). We have systematically studied the aspects of image formation of DABox by RCM by using a model system consisting of glass slides coated with peroxidase containing protein layers to determine the conditions for optimal sensitivity of this detection method. Moreover, investigations were performed to study the relationship between the amount of reflected light and DABox depending on the thickness of the object. Both theoretical and practical evidence is obtained to show that DABox detection by RCM is based on interference phenomena occurring in the layer of DABox, and less on selective reflection. This restricts the type of specimen which can be used for sensitive detection of DABox by RCM. Consequently, in ultrathin (40 nm) sections osmificated DABox was visualized in peroxidatic positive cell organelles with high contrast and resolution. Similar results were obtained with immunoperoxidase stained material embedded in Lowicryl under conditions that did not allow visualization of the staining product by bright field microscopy.

3,3'-Diaminobenzidine↗