Search PubMed⌕ Search

Biomedical subjects

I Birdi

Publications and source records attributed to I Birdi.

28 records · Page 2Linked to original sources

Comparison of hemodynamic performances of St. Jude Medical and CarboMedics 21 mm aortic prostheses by means of dobutamine stress echocardiography.

Dobutamine stress Doppler echocardiography was used to compare the hemodynamic performance of two small aortic bileaflet prostheses. Nineteen patients (14 female, mean age 64 years) who had undergone aortic valve replacement with 21 mm bileaflet valve prostheses (St. Jude Medical valve, n = 9, or CarboMedics valve, n = 10) were studied. Dobutamine infusion was started at a rate of 5 micrograms.kg-1.min-1 and increased to 10 and 20 micrograms.kg-1.min-1 at 15-minute intervals. Under maximum stress, heart rate and cardiac output increased by 70% and 120%, respectively, and mean arterial blood pressure decreased by 9%. Pulsed-wave and continuous-wave Doppler studies were performed at rest and at the end of each stage. Velocity ratio, effective orifice area, performance index, and discharge coefficient of the valve were calculated, and peak and mean velocities and pressure drops across the prostheses were measured. Dobutamine infusion produced similar increases in cardiac output in all patients. Effective orifice areas, discharge coefficients, and performance indexes were comparable for the two valve groups both at rest and maximum stress. Transvalvular velocities and pressure drops were also similar in the two valve groups. Transvalvular pressure drops were also comparable in patients with large body surface area. Dobutamine stress echocardiography is useful in the evaluation of the hemodynamic performance of prosthetic heart valves. St. Jude Medical and CarboMedics 21 mm prostheses have equally favorable hemodynamic performances in most patients under conditions of high cardiac output.

Aged↗

Evaluation of the hemodynamic performance of small CarboMedics aortic prostheses using dobutamine-stress Doppler echocardiography.

BACKGROUND: The well-known correlation between prosthetic valve orifice area and transvalvular gradients has raised concerns about the presence of significant residual gradients when the size of the prosthesis that can be implanted is limited by the presence of a small aortic annulus. METHODS: Dobutamine-stress Doppler echocardiography was used to evaluate the hemodynamic performance of small CarboMedics aortic prostheses (19 mm and 21 mm) in 18 patients (16 women; mean age, 64 years) who had undergone aortic valve replacement 23.5 +/- 19 months (standard deviation) previously. Dobutamine infusion was started at a rate of 5 micrograms.kg-1.min-2 and increased to 10 and 20 micrograms.kg-1.min-2 at 15-minute intervals. Pulsed and continuous wave Doppler studies were performed at rest and at the end of each stage. Effective orifice area, performance index, and discharge coefficient of both valves were calculated, and peak and mean velocity and pressure drop across the prostheses were measured. RESULTS: Heart rate and cardiac output increased by 74% and 94%, respectively, and mean arterial blood pressure decreased by 9% at maximum stress. Effective orifice area, discharge coefficient, and performance index were comparable in both valve sizes at rest and maximum stress. Also, there was no significant difference in mean transvalvular pressure drop (gradient) for 19-mm and 21-mm prostheses at rest (8.1 +/- 8.4 and 4.8 +/- 3.8 mm Hg) or maximum stress (15.1 +/- 14.2 and 8.8 +/- 5.8 mm Hg, respectively). No significant correlation could be demonstrated between transvalvular pressure drop and patient's body surface area. CONCLUSIONS: These data show that 19-mm and 21-mm CarboMedics aortic prostheses exhibit equally favorable hemodynamic performance with minimal pressure gradient, both at rest and under stress conditions.

Aged↗

In-hospital audit underestimates early postoperative morbidity after cardiac surgery.

BACKGROUND: The demand for open heart surgery has driven current practice towards early postoperative discharge and interhospital transfer to maximise patient throughput. The extent to which this redirects morbidity to other healthcare providers is unknown. OBJECTIVE: To define the incidence of inhospital and early postoperative morbidity within 6 weeks of primary hospital discharge after cardiac surgery. DESIGN: Prospective inhospital data for 322 consecutive adult patients undergoing cardiac surgery were compared with retrospective information obtained by postal questionnaire. RESULTS: Mean (SD) primary postoperative hospital stay was 8.3 (3.1) days. There were 13 inhospital deaths (4%), and three patients died within 6 weeks of primary discharge. Retrospective information was obtained from 297 patients (96%). Of these, 77% patients were discharged home directly, while 23% were transferred to other hospitals for continued medical care. Mean (SD) hospital stay after transfer was 12 (8.4) days and required 741 additional hospital bed days. Thirty nine patients (13%) were readmitted to hospital, requiring a further 275 hospital bed days. The readmission rate was lower in patients sent home directly (10%), than in those who were transferred (22%; P < 0.001). CONCLUSIONS: Inhospital audit underestimates early morbidity after cardiac surgery. The burden transferred to other healthcare providers is considerable and has important financial implications for purchasers.

Cardiac Surgical Procedures↗

Cardiopulmonary bypass perfusion temperature does not influence perioperative renal function.

BACKGROUND: The recent introduction of normothermic cardiopulmonary bypass (CPB) perfusion has raised concerns regarding the associated risk of renal dysfunction through its potential to exacerbate the systemic inflammatory response and end-organ injury. This study was designed to investigate the influence of CPB perfusion temperature on renal function. METHODS: A prospective, randomized, controlled trial of CPB perfusion temperature (28 degrees C, 32 degrees C, and 37 degrees C) was performed in 30 patients undergoing routine coronary artery bypass grafting with normal preoperative renal function. Creatinine clearance was measured before induction of anesthesia, during CPB, and during every 12-hour period thereafter for 48 hours postoperatively. Glomerular and tubular function were assessed further by measurement of urinary creatinine, albumin, total protein, and retinol binding protein levels preoperatively, during CPB, and on days 1 and 3 postoperatively. RESULTS: Creatinine clearance increased on CPB by 51% (28 degrees C), 185% (32 degrees C), and 112% (37 degrees C) (all p < 0.01 versus preoperative values) and returned to preoperative values by 24 hours postoperatively in all three groups. Urinary albumin/creatinine ratios rose significantly from a mean of 0.4 +/- 0.1 (standard deviation) to 10 +/- 12.5 (28 degrees C), from 0.55 +/- 0.3 to 5.2 +/- 4.9 (32 degrees C), and from 0.96 +/- 0.8 to 7.8 +/- 7.0 (37 degrees C) during CPB (all p < 0.001) but decreased gradually thereafter. Also, urinary total protein/creatinine ratios rose significantly from a mean of 0.009 +/- 0.007 to 0.034 +/- 0.02 (28 degrees C), from 0.01 +/- 0.006 to 0.026 +/- 0.01 (32 degrees C), and from 0.011 +/- 0.008 to 0.033 +/- 0.02 (37 degrees C) during CPB (all p < 0.005); however, there was a further increase by 24 hours, and ratios decreased gradually thereafter. Similarly, urinary retinol binding protein/creatinine ratios rose significantly in all three groups during CPB (all p < 0.0001) and increased further by 24 hours. There was no statistically significant difference between the renal markers in the three temperature groups in any of the observations. CONCLUSION: These data suggest that cardiopulmonary bypass perfusion temperature does not influence renal function in patients undergoing coronary artery bypass grafting.

Aged↗

Thrombolytic therapy for left sided prosthetic heart valve thrombosis.

In order to clarify the role of thrombolytic therapy for the treatment of left sided prosthetic valve thrombosis, a composite analysis of 158 cases reported in the English literature was undertaken. Complete success of therapy was achieved in 68.4% of patients, and the results were better in patients with aortic compared to mitral valve prostheses (p < 0.01), in those presenting in lower NYHA class (p < 0.01), and with acute rather than chronic symptoms (p < 0.05). A successful outcome was seen more frequently with tilting disc than bileaflet valves (p < 0.001). Overall mortality during therapy was 7%. Cerebral embolic events were observed in 9.5% of patients, and irreversible neurological injury occurred in 4.4%. The rethrombosis rate was 17% and the incidence of late death was 6.3%. Thrombolysis may be a useful therapeutic alternative for left sided prosthetic valve thrombosis in patients with a perceived contraindication to surgery. The risks of systemic clot embolization along with incomplete resolution of valve leaflet motion or rethrombosis limits any recommendation for more widespread use.

Adult↗

Laparoscopic cholecystectomy in Leicester: an audit of 555 patients.

Laparoscopic techniques have revolutionised the surgical approach to cholecystectomy, even though there have been no published randomised controlled trials to demonstrate the safety of this approach. We present an audit of 555 patients offered laparoscopic cholecystectomy. In all, 54 patients (9.7%) were converted to an open procedure. Peroperative cholangiography (POC) was attempted in 190 cases (34.2%) and achieved in 141 (25.4%). Major complications occurred in 26 cases (4.7%) including 5 (0.9%) deaths, two of whom had major pre-existing morbidity. There was one common bile duct (CBD) injury (0.18%). There were 30 patients (5.4%) found to have CBD stones, 27 of which were cleared at ERCP, and three converted to open exploration. Cholecystectomy by any route is a major operation and we conclude that careful case selection remains imperative. However, morbidity is favourable compared with open cholecystectomy, and comparable with other reports using the laparoscopic technique. Our experience of CBD injury (0.18%) is also acceptable compared with the risk of injury during open cholecystectomy. There were 312 patients (56.2%) who did not undergo perioperative CBD imaging with ERCP or POC and three of these developed early symptomatic retained stones. This group requires further follow-up.

Adolescent↗

The substrate determines the rate and pattern of neutral lipid synthesized by isolated human sebaceous glands.

Lipogenesis from different substrates was determined in isolated human sebaceous glands after 17-20 h in culture. Rates of total lipogenesis were 1003 +/- 141, 842 +/- 90, 481 +/- 57 pmol.h-1 gland-1 +/- SE from acetate, lactate and glucose, respectively, when present as sole substrates: the rate from glucose was significantly lower (P less than 0.01). Squalene synthesis was greatest from acetate at 479 +/- 44 pmol.h-1.gland-1; significantly higher than from lactate (281 +/- 45 pmol.h-1.gland-1) or glucose at 119 +/- 18 pmol.h-1.gland-1. Wax ester plus cholesterol ester synthesis showed similar dependence on substrate but triglyceride synthesis was unaffected. We conclude that the added substrate determines both the rate and pattern of non-polar lipid synthesized by isolated human sebaceous glands.

Acetates↗