[Hyperbaric oxygen therapy. Will radiation ulcers healing in hyperbaric pressure? (interview by Dr. Ulrich Scharmer)].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to I A Adamietz.
Explore the source record for details and available documents.
BACKGROUND: In case of recurrent carcinoma of the head and neck region therapeutic options are often limited due to intensive prior therapy and/or reduced physical condition of the patient. Nevertheless there is a need for palliative treatment to control symptoms like pain, obstruction of the airways, dysphagia and for hygienic and cosmetic reasons. Side effects, treatment time and achievable results have to be adjusted to the needs of this patient subgroup. PATIENTS AND METHOD: 14 patients (13 male, one female) with recurrent squamous cell carcinoma of the head and neck region were studied. Average age was 56.1 years (range 42-76 years) (Table 1). Prior therapy: radiotherapy n = 14 (42-71.3 Gy), surgery: n = 10, chemotherapy: n = 13 (Table 2). Our patients received 100-150 mg/m2 Bendamustin i.v. (day 1 and 2) and involved field irradiation 15 Gy (daily dose 3 Gy, day 1-5) (Figure 1). Remission status, time to progression, side effects and survival were documented. RESULTS: Ten patients showed partial remissions, four patients had complete remissions of the treated lesion (Figure 2), amelioration of 70% of tumor symptoms was documented (Figure 3). Time to progression was 2-104 weeks. Side effects: 71% of patients had no significant side effects, CTC Grade 3 to 4 toxicity was seen in two patients (14%). CONCLUSION: The reported therapy regimen allows successful palliative treatment of intensively pretreated patients with progressive recurrent tumors of the head and neck. Side effects are tolerable even in patients with reduced physical condition.
Colorectal carcinoma is one of the most common cancer in Germany. We want to evaluate the most reliable CT features indicating local recurrence of rectal cancer as early as possible. 232 patients suffering from rectal cancer being administered to our clinic from 1987-1998 were investigated. Criteria for inclusion: patients after surgery and radiotherapy of rectal cancer with a minimum follow-up of two years and at least 3 CT examinations. All CT examinations were analyzed standardized. The main target parameters for relapse were enlargement of a presacral mass, inhomogeneous appearance, asymmetric outlines, enlarged lymph nodes and infiltration of the surrounding structures. An unchanged appearance of the presacral space in more than three CT examinations after surgery correlated with freedom of recurrence.
BACKGROUND: In literature there are only few informations about the influence of postoperative irradiation on the psychological health of breast cancer patients treated by breast-conserving surgery. However, psychological distress and anxiety related to irradiation are often observed. Purpose of our study was the evaluation of the influence of radiotherapy-induced distress in these patients. PATIENTS AND METHODS: Between October 1995 and June 1996 in 48 breast cancer patients (31 to 76 years old) treated by breast-conserving surgery adjuvant irradiation with or without systemic therapy was applied. On the first and the last day of radiotherapy they were given a questionnaire (Table 1) which was designed together with psychologists. Covering different situations related to radiotherapy the construction of items are determined by factors with possible influence on psychological distress and perception with regard to irradiation. RESULTS: Most of the women (92%) stated to be well informed about the irradiation and tried to obtain further information about this treatment (83%). 56% tried not to think about radiotherapy and/or to distract themselves (81%). 40% were anxious about the fact to undergo irradiation. In the end of treatment 77% reported to have been anxious only initially or never; only 19% were anxious almost or most of the time. 35% were worried about the expected cosmetic alterations of their breast; only 30% observed acute cosmetic changes. With regard to situation-related distress all patients (100%) stated that the communication with the medical staff made it easier to stand the irradiation treatment. CONCLUSIONS: In spite of theoretical considerations our results are explorative in character. However, following statements seem to be important: 1. A large requirement exists to get information about radiotherapy. 2. The patients experience irradiation treatment more positive than initially expected by themselves. 3. With regard to radiotherapy anxiety is reduced during the course of treatment. Here the psychosocial care of the medical staff is an important support for reduction of anxiety.
In palliative treatment, irregularly shaped fields are used to reduce side-effects and can improve, or avoid, field matching. We investigated the effectiveness of a multileaf collimator (MLC) supported by a digitizing data entry system in the palliative radiotherapy treatment of 66 patients and compared it with conventional shielding with geometrically shaped blocks. After conventional simulation of rectangular fields, irregular field shapes were marked on the simulator film in 17 patients (27%) to reduce radiotherapy related side-effects. Individual leading was performed with an MLC. Digitizing and fitting of the optimum leaf position were carried out using a multileaf preparation system (MLP, Elekta, Crawley, UK). Target volumes included bone metastases in the pelvis, spine and extremities, mediastinal soft tissues, lymph nodes and central nervous system. In 10 patients, treated with a parallel pair for pelvic metastases, MLC and conventional shielding were prospectively compared with regard to time requirements and area shielded. Compared with conventional blocking, the mean simulation, preparation and treatment time required for MLP fields was shorter (9.55 +/- 1.44 min vs 16.90 +/- 2.64 min, and 5.50 +/- 1.14 min vs 8.97 +/- 1.75 min). The mean shielded area was 31 cm2 larger for MLC fields compared with geometrically shaped blocks (p < 0.05). Compared with cerrobend blocking, the use of an MLC, supported by preparation data entry software, is more flexible and reduces radiotherapy resources. Therefore, a preparation data entry system as a separate device, or integrated into the treatment planning system, is a useful tool in palliative treatment.
PURPOSE: Very young children with medulloblastoma are considered to have a worse prognosis than older children. As radiotherapy remains an important part of the treatment, the adverse prognosis could be due to inadequate radiation treatment rather than biological factors. We analyzed the published literature to examine the impact of radiotherapy on survival in this group. METHODS AND MATERIALS: A Medline search was performed and we reviewed studies of treatment of medulloblastoma where radiotherapy was delivered using megavoltage equipment and the minimum follow-up allowed the calculation of 5-year survival rates. RESULTS: Thirty-nine studies were published between 1979 and 1996 with a treatment including craniospinal irradiation and boost to the posterior fossa. Eleven studies comprising 1366 patients analyzed survival by age at diagnosis. Eight of 11 studies showed a worse 5-year survival for the younger patient group which reached statistical significance in two. There is also a suggestion of a higher proportion of children with metastatic disease at presentation in the very young age group. The usual policy in younger children was to give a lower dose of radiotherapy to the craniospinal axis (CSA) and posterior fossa (PF) with reduction of dose in the range of 15 to 25% compared to standard treatment. As dose reduction to the posterior fossa is associated with worse survival and local recurrence is the predominant site of failure, the major determinant of worse survival in very young children with medulloblastoma may be suboptimal radiotherapy. Protocols including postoperative chemotherapy with delayed, omitted, or only local tumor irradiation do not reach survival rates of protocols with standard radiotherapy, also suggesting a continued importance for irradiation. CONCLUSION: Very young children with medulloblastoma have a worse prognosis than older children. Inadequate radiation dose and technique to the primary tumor region may be a major contributing factor. Current chemotherapeutic regimes alone are not sufficient to compensate for reduced radiation doses and volumes.
PURPOSE: The use of positioning and immobilization techniques during external beam irradiation of the female breast is time consuming and expensive. The currently available standardized positioning devices are insufficient. For this reason, we designed a new and generally useable hard foam positioning support cushion for the use during breast irradiation, and tested its clinical usefulness in a prospective study. METHODS AND MATERIALS: Fifty-five female breast cancer patients receiving adjuvant radiotherapy following breast-conservative surgery were irradiated either without immobilization (n = 27) or with the positioning support cushion (n = 28). The time necessary for patient setup, the lying subjective comfort and--comparing portal images with simulator images--the reproducibility of the set up were determined. RESULTS: Irradiation reproducibility was significantly improved (average deviation without positioning support cushion: 8.4 mm, with positioning support cushion: 6.1 mm, p < 0.001). The time required for the positioning of the patient with positioning support cushion was in average 73 s, without cushion it was 55 s. A significantly higher proportion of patients (72%) found the position with the positioning support cushion as pleasant, whereas only 46% of patients were pleased with the position without cushion. CONCLUSION: The positioning support cushion designed in our department makes a substantial contribution to quality assurance in breast irradiation. It significantly increases the patients' comfort in a supine position. In contrast to conventional positioning and fixation aids it may be quickly and easily applied at low costs. Therefore, its use can be recommended.
PURPOSE: An individualized radiation treatment planning in patients with head and neck tumors requires an exact definition of tumorspread. Despite of high reliability of methods like computed tomography, sonography or magnetic resonance imaging used in daily routine, the correct diagnosis of lymphonodal tumor infiltration is often not possible. In a prospective trial, we examined whether an additional FDG-PET gives a relevant gain of information for radiation treatment planning. PATIENTS AND METHODS: We studied data of 34 patients with histologically confirmed squamous cell carcinoma of the head and neck who received a FDG-PET prior to treatment planning additionally to conventional staging procedures. The extent of changes of treatment strategy or target volume due to additional FDG-PET findings were analyzed. RESULTS: In 9/22 of patients with primary tumors and in 7/12 of patients with recurrent disease, FDG-PET detected additional tumor manifestations. In all cases, changes of treatment strategy or target volume were necessary. Regarding patients with primary tumors, the percentage of treatment modifications was highest in patients with large tumors (T3 and T4) and patients with advanced lymph node involvement (N2 and N3). CONCLUSIONS: Especially in patients with recurrent disease and patients with advanced tumor stages, FDG-PET is able to give clinically relevant information compared to conventional staging procedures. Therefore, in these group of patients a FDG-PET study prior to radiotherapy planning should be considered.
BACKGROUND: Oral mucositis is a frequent complication of radiochemotherapy. The origin of radiation-induced mucosa lesions is of iatrogenic nature although further development of mucositis is essentially influenced by infection. It can be assumed that disinfection measures should decrease the severity of mucositis induced by radiochemotherapy. Therefore, in a prospective randomised study the efficacy of prophylactic oral rinsing with a disinfection agent was investigated. PATIENTS AND METHOD: An open, randomised, prospective comparative trial was conducted with 40 patients undergoing radiochemotherapy of head and neck region due to malignant disease. The treatment scheme consisted of irradiation to tumor region and adjacent lymph nodes with a total dose of 71.3 Gy and simultaneous chemotherapy with carboplatin (60 mg/m2) on days 1 to 5 and 29 to 34. In all patients, a prophylaxis of mucositis with nystatine, rutosides, panthenol and immunoglobulin was undertaken. In addition, 20 patients rinsed oral cavity 4 times daily with povidone-iodine-solution, the comparative group rinsed with sterile water. Clinical examination of the oral mucosa was performed weekly. Onset, grading and duration of mucositis were used as main variables. RESULTS: Clinically manifested oral mucositis was observed in 14 patients of the iodine group (mean grading: 1.0) and all 20 patients of the control group (mean grading: 3.0). Total duration (mean) of clinically observed mucositis was 2.75 weeks in treatment patients and 9.25 in control patients. Median AUC (area under curve for grade vs duration) was 2.5 in iodine rinsing patients and 15.75 in control patients. All differences found between the 2 groups were statistically significant. Increased iodine incorporation was not observed. A pathological increase of thyroid hormone levels in the iodine group was not found. CONCLUSIONS: The gained results indicate that incidence, severity and duration of radiochemotherapy-induced mucositis can be significantly reduced by oral rinsing with povidone-iodine performed additionally to the standard prophylaxis scheme.
PURPOSE: In the treatment of differentiated thyroid carcinomas the indication for adjuvant radiotherapy is discussed contradictory. The following study analyzes the long-term survival rates of patients with follicular and papillar thyroid carcinomas after percutaneous radiotherapy. PATIENTS AND METHOD: Records of 178 patients with differentiated thyroid carcinomas (132 female, median age 46 years; 46 male, median age 47 years) were evaluated. Following thyroid-resection and radioiodine therapy external beam irradiation was performed with a telecobalt device and high energy electrons (mean reference dose 54.7 Gy). Hundred and twenty patients (67.4%) had a histologically confirmed papillary carcinoma, 58 (32.6%) patients had follicular carcinoma. In the group with papillary carcinoma 57 patients (47.5%) were classified as stage I, 11 patients (9.2%) as stage II, 48 patients (40.0%) as stage III, 4 patients (3.3%) as stage IV, respectively, in the group with follicular carcinoma 21 patients (36.2%) were classified as stage I, 4 patients (6.9%) as stage II, 28 patients (48.3%) as stage III and 5 patients (8.6%) as stage IV. Survival, recurrence rate and prognostic factors were analyzed.
BACKGROUND: Positioning and immobilisation techniques are essential for precise radiotherapy. The currently available standardised positioning devices are insufficient. For this reason, we designed a new and generally usable hard foam positioning support cushion for the breast irradiation and tested its usefulness in a prospective study. PATIENTS AND METHODS: Fifty-five female breast cancer patients receiving adjuvant radiotherapy following breast conservative surgery were irradiated either without immobilisation (n = 27) or with the developed positioning support cushion (n = 28). The time necessary for patient set-up, the subjective lying comfort and--comparing portal images with simulator images--the reproducibility of the set-up were determined. RESULTS: It was possible to improve irradiation reproducibility significantly (average deviation without positioning support cushion: 8.4 mm, with positioning support cushion: 6.1 mm, p < 0.001). The additional time required for the positioning of the patient was in average 19 s (with positioning support cushion: 74 s, without cushion: 55 s). A significantly higher proportion of patients (72%) found the position with the hard foam cushion was pleasant, whereas only 46% of patients were pleased with the position without cushion. CONCLUSION: The positioning support cushion designed in our department seems to play an important role in quality assurance of external beam irradiation of the breast and significantly increases the patients' comfort in a supine position. Compared to conventional positioning and fixation devices it may be quickly and easily applied at low cost. Therefore, its use can be recommended.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Oral mucositis is a frequent complication of radiochemotherapy. The origin of radiation-induced mucosal lesions is iatrogenic in nature, although further development of mucositis is essentially influenced by infection. It can be assumed that disinfection measures should decrease the severity of mucositis induced by radiochemotherapy. Therefore, in a prospective randomised study the efficacy of prophylactic oral rinsing with a disinfection agent was investigated. A randomised, prospective comparative trial was conducted with 40 patients undergoing radiochemotherapy of the head and neck region because of malignant disease. The treatment scheme consisted of irradiation to the tumour region and adjacent lymph nodes, with a total dose of 71.3 Gy, and simultaneous chemotherapy with carboplatin (60 mg/m2) on days 1-5 and 29-34. In all patients mucositis prophylaxis with nystatin, rutosides, panthenol and immunoglobulin was undertaken. In addition, 20 patients rinsed the oral cavity 4 times daily with povidone-iodine solution, while the group for comparison rinsed with sterile water. Clinical examination of the oral mucosa was performed weekly. Onset, grading and duration of mucositis were used as the main variables. Clinically manifest oral mucositis was observed in 14 patients in the iodine group (mean grading: 1.0) and in all 20 patients in the control group (mean grading: 3.0). The total duration (mean) of clinically observed mucositis was 2.75 weeks in treatment patients and 9.25 weeks in control patients. Median AUC (area under curve for grade vs duration) was 2.5 in the iodine rinsing patients and 15.75 in control patients. All differences found between the two groups were statistically significant. Increased iodine incorporation was not observed. A pathologic rise in thyroid hormone levels was not found in the iodine group. The results obtained indicate that incidence, severity and duration of radiochemotherapy-induced mucositis can be significantly reduced by oral rinsing with povidone-iodine in addition to the standard prophylaxis scheme. It can be concluded that rinsing with povidone-iodine is an easy, cheap and safe prophylactic method and can be recommended as a supportive treatment during antineoplastic treatment of the head and neck region.
Explore the source record for details and available documents.
AIM: Factors which influence the accuracy of the field application during daily irradiation routine are not well known. The aim of this prospective analysis was to determine the significance of these factors on the occurrence of field misadjustments in irradiation without immobilization and to evaluate their clinical relevance. PATIENTS AND METHODS: Fifty-three patients received external cobalt-60 beam irradiation without fixation. Once weekly portal images of all treatment fields were carried out. In addition to objective patient data (age, weight, height, general condition, irradiation indication), the psychological situation of the patient during treatment (anxiety, restlessness, pain) and work circumstances of the medical staff during treatment were evaluated once weekly. The distance of clearly visible anatomic structures to the field borders of the portal images were measured and the deviation to the corresponding simulator images was calculated. Patient data were correlated to the number of field misadjustments (deviation larger than 1 cm). RESULTS: Patients whose condition is generally poor and patients being treated palliatively, patients with feeling of anxiety, restlessness or pain during simulation or irradiation and heavy patients (90 kg and more) were more often misadjusted. The number of field misadjustments increased with the stress of the medical staff. CONCLUSIONS: The problem of reproducibility of external beam irradiation without fixation in palliative treatment is of clinical relevance. Effective analgesic therapy and a comfortable and painfree patient set-up reduce misadjustments. In curative treatment, immobilization techniques should be used.
Explore the source record for details and available documents.
Explore the source record for details and available documents.