Search PubMed⌕ Search

Biomedical subjects

Hyo Sung Kwak

Publications and source records attributed to Hyo Sung Kwak.

7 recordsLinked to original sources

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy.

Aged, 80 and over↗

Hepatocellular carcinoma in patients with chronic liver disease: comparison of SPIO-enhanced MR imaging and 16-detector row CT.

PURPOSE: To compare the sensitivity, positive predictive value, and diagnostic accuracy of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging with those of 16-detector row computed tomography (CT) for the detection of hepatocellular carcinoma (HCC) in patients with hepatitis B-induced cirrhosis. MATERIALS AND METHODS: Institutional Review Board approval was obtained for this study, and informed consent was obtained from all patients. A total of 44 patients (36 men, eight women; age range, 35-67 years) with 59 HCCs and mild liver cirrhosis (Child-Pugh score A or B) underwent multiphasic CT and SPIO-enhanced MR imaging. The diagnosis of HCC was established at surgical resection (n = 31) and percutaneous biopsy (n = 28). SPIO-enhanced MR imaging was composed of T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences. Multiphasic CT consisted of four phases (ie, early arterial, late arterial, portal venous, and equilibrium). Three observers independently analyzed each image in random order. Sensitivity, positive predictive value, and diagnostic accuracy were calculated by using the alternative free-response receiver operating characteristic analysis for multi-detector row CT and SPIO-enhanced MR imaging. RESULTS: Although not significant (P > .05), the area under the receiver operating characteristic curve for SPIO-enhanced MR imaging (mean, 0.90) was higher than that for multi-detector row CT (mean, 0.82) for all observers. Also, although no significant difference was demonstrated by any of the three observers (P > .05), there was a trend toward increased sensitivity on both a per-lesion and a per-patient basis for SPIO-enhanced MR imaging (mean, 84.7% and 94.7%, respectively) compared with multi-detector row CT (mean, 76.9% and 88.6%, respectively). No significant difference in positive predictive value was observed between modalities. CONCLUSION: SPIO-enhanced MR imaging and multiphasic CT show similar diagnostic accuracy, sensitivity, and positive predictive value for the detection of HCC in patients with relatively mild hepatitis B-induced cirrhosis.

Adult↗

Three-dimensional dynamic liver MR imaging using sensitivity encoding for detection of hepatocellular carcinomas: comparison with superparamagnetic iron oxide-enhanced mr imaging.

PURPOSE: To assess the diagnostic performance of three-dimensional dynamic liver imaging with sensitivity encoding (SENSE), including double arterial phase images and increased resolution, by comparing it to superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging for the detection of hypervascular hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty-seven consecutive patients with 50 HCCs underwent Gd-BOPTA-enhanced dynamic imaging using SENSE and SPIO-enhanced MR imaging with at least a 24-hour interval between examinations. Using a three-dimensional gradient-echo technique applying SENSE, dynamic imaging consisting of double arterial phase-, portal phase- and delayed phase-images, was obtained. Using T2-weighted turbo spin-echo and T2*-weighted fast imaging with steady-state precession sequence, SPIO-enhanced MR imaging was obtained. For qualitative analysis, the diagnostic accuracy of both MR examinations for detecting the 50 HCCs was evaluated using the alternative free-response receiver operating characteristic method. Sensitivity and positive predictive value were also evaluated. RESULTS: The mean sensitivity and positive predictive value of three-dimensional dynamic imaging with SENSE were 91.3% and 89.2%, respectively, and those of SPIO-enhanced imaging were 77.3% and 92.6 %, respectively. There was a significant difference in sensitivity between the two images (P <0.05). The mean Az value of three-dimensional dynamic imaging with SENSE (0.97 +/- 0.01) was significantly higher than that of SPIO-enhanced imaging (0.90 +/- 0.02) (P=0.00). CONCLUSION: Three-dimensional dynamic liver MR imaging using SENSE for acquiring double arterial phase images is more efficient than SPIO-enhanced MR imaging for detecting HCCs.

Carcinoma, Hepatocellular↗

Comparison of superparamagnetic iron oxide-enhanced and gadobenate dimeglumine-enhanced dynamic MRI for detection of small hepatocellular carcinomas.

OBJECTIVE: The purpose of this study was to compare superparamagnetic iron oxide (SPIO)-enhanced MRI with gadobenate dimeglumine-enhanced MRI for the detection of hepatocellular carcinoma using receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS: Twenty-nine consecutive patients with 35 hepatocellular carcinomas underwent gadobenate dimeglumine-enhanced MRI (unenhanced, arterial, portal, and equilibrium phases) using 3D fat-saturated volumetric interpolated imaging and SPIO-enhanced MRI on a 1.5-T unit. SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences were performed 48 hr after completion of the dynamic study. Three observers independently interpreted the images in random order, separately, and without patient identifiers. Diagnostic accuracy was evaluated using the alternative free response receiver operating characteristic method. Sensitivity and positive predictive value were also evaluated. RESULTS: The mean sensitivity and positive predictive value of SPIO-enhanced imaging were 81.0% and 85.0%, respectively, and those of gadobenate dimeglumine-enhanced MRI were 91.4% and 88.1%, respectively. A significant difference was seen in the sensitivity of the two MRI examinations (p < 0.05). The mean value of the area under the ROC curve (A(z)) for gadobenate dimeglumine-enhanced imaging (A(z) = 0.97 +/- 0.01) was significantly higher than that for SPIO-enhanced imaging (A(z) = 0.90 +/- 0.02) (p = 0.004). CONCLUSION: Gadobenate dimeglumine-enhanced 3D dynamic imaging showed better diagnostic performance than SPIO-enhanced imaging for the detection of hepatocellular carcinomas.

Adult↗

Radiologic findings of multiple myeloma with gastric involvement: a case report.

We report a case of multiple myeloma with gastric involvement occurring in a patient who underwent an upper gastrointestinal series (UGIS), CT and MRI. UGIS depicted a luminal protruding mass, while contrast-enhanced CT demonstrated marked thickening of the gastric wall, with subtle contrast enhancement. At T1- and T2-weighted MR imaging, the mass showed iso- and intermediate signal intensity, respectively. After the administration of contrast material, subtle homogeneous enhancement was apparent.

Contrast Media↗

Radio frequency ablation in the rabbit lung using wet electrodes: comparison of monopolar and dual bipolar electrode mode.

OBJECTIVE: To compare the effect of radio frequency ablation (RFA) on the dimensions of radio frequency coagulation necrosis in a rabbit lung using a wet electrode in monopolar mode with that in dual electrode bipolar mode at different infusion rates (15 mm/hr versus 30 ml/hr) and saline concentrations (0.9% normal versus 5.8% hypertonic saline). MATERIALS AND METHODS: Fifty ablation zones (one ablation zone in each rabbit) were produced in 50 rabbits using one or two 16-gauge wet electrodes with a 1-cm active tip. The RFA system used in the monopolar and dual electrode wet bipolar RFA consisted of a 375-kHz generator (Elektrotom HiTT 106, Berchtold, Medizinelektronik, Germany). The power used was 30 watts and the exposure time was 5 minutes. The rabbits were assigned to one of five groups. Group A (n = 10) was infused with 0.9% NaCl used at a rate of 30 ml/hr in a monopolar mode. Groups B (n = 10) and C (n = 10) were infused with 0.9% NaCl at a rate of 15 and 30 ml/hr, respectively in dual electrode bipolar mode; groups D (n = 10) and E (n = 10) were infused with 5.8% NaCl at a rate of 15 and 30 ml/hr, respectively in a dual electrode bipolar mode. The dimensions of the ablation zones in the gross specimens from the groups were compared using one-way analysis of variance by means of the Scheffe test (post-hoc testing). RESULTS: The mean largest diameter of the ablation zones was larger in dual electrode bipolar mode (30.9+/-4.4 mm) than in monopolar mode (22.5+/-3.5 mm). The mean smallest diameter of the ablation zones was larger in dual electrode bipolar mode (22.3+/-2.5 mm) than in monopolar mode (19.5+/-3.5 mm). There were significant differences in the largest and smallest dimension between the monopolar (group A) and dual electrode wet bipolar mode (groups B-E). In dual electrode bipolar mode, the mean largest diameter of the ablation zones was larger at an infusion rate of 15 ml/hr (34.2+/-4.0 mm) than at 30 ml/hr (27.6+/-0.1 mm), and the mean smallest diameter of the ablation zones was larger at an infusion rate of 15 ml/hr (27.2+/-7.5 mm) than at an infusion rate of 30 ml/hr (24+/-2.9 mm). CONCLUSION: Using a wet electrode, dual electrode bipolar RFA can create a larger ablation zone more efficiently than monopolar RFA.

Animals↗