Three saints and critical limb ischemia.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Hutan Ashrafian.
Explore the source record for details and available documents.
Auscultation for thoracic aortic aneurysms and dissections is largely limited to listening to praecordium, neck and axillae associated with disease located at the ascending aorta and root, typically overlooking the descending thoracic aorta. We report a new test and protocol for differentiating aortic root and descending aortic disease by adding auscultation over the back as part of the cardiovascular examination.
Aortic regurgitation is associated with numerous eponymous signs. We report the case of a patient with this condition who presented with a previously unidentified sign, namely pulsatile pseudo-proptosis. Furthermore, we place this in context by listing and describing to the best of our knowledge the largest all-inclusive series to-date of named signs.
Explore the source record for details and available documents.
OBJECTIVE: The primary limitation of the American Heart Association/American College of Cardiology guidelines is specificity. To improve the selection process, we proposed a simple additive model including age (1 point for every 5 years above 50), male sex (2 points), hypercholesterolemia (2 points), angina (3 points), and electrocardiographic evidence of ischemia (3 points). We recommend screening angiography at 3 or more points. This model was previously derived from 359 patients at Papworth Hospital. METHODS: The validation cohort was a consecutive series of patients who underwent mitral valve surgery at the Royal Brompton Hospital. Preoperative coronary angiography reports were obtained, and coronary disease was defined as luminal narrowing of 50% in 2 or more views. Sensitivities and specificities were calculated for the American Heart Association/American College of Cardiology criteria, the simple additive model, and a logistic regression model. Receiver operating characteristic curves were used to validate accuracy and compare discrimination with logistic regression. RESULTS: From 1998 through 2003, angiographic details were available for 342 (86%) of 396 patients who underwent mitral valve surgery. The sensitivity and specificity of the American Heart Association/American College of Cardiology guidelines were 100% and 5%, respectively; those of the simple additive model were 91% and 44%, respectively; and those of logistic regression were 93% and 41%, respectively. The receiver operating characteristic areas for the simple additive and logistic regression model were 0.78 (95% confidence interval, 0.73-0.84) and 0.80 (95% confidence interval, 0.74-0.85), respectively. CONCLUSIONS: This is the third independent cohort to highlight the poor specificity of the American Heart Association/American College of Cardiology guidelines. Although high sensitivity is achieved, the cost is the majority of patients requiring screening angiography. Our validated simple model improved the specificity and selection; however, this was achieved at the expense of decreased sensitivity.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Primary intracardiac malignant mesotheliomas are extremely rare and carry a very poor prognosis. We present such a case where the lesion encompassed two chambers, the left atrium and ventricle, with no pericardial involvement. Initial echocardiography mimicked a myxoma, and urgent surgical intervention was required in view of significant cardiorespiratory compromise. To the best of our knowledge this is the first case of a primary two-chamber intracardiac malignant sarcomatoid mesothelioma.
BACKGROUND AND AIM OF THE STUDY: Stentless prostheses in the aortic position produce a superior hemodynamic profile in comparison to that with stented valves. To determine whether routine use of stentless valves in an elderly population is justified, a 10-year retrospective review was performed of a consecutive series of patients aged > or =75 years undergoing stentless aortic valve replacement (AVR). METHODS: Demographic, operative and mortality data were obtained retrospectively. Survivors were interviewed by telephone according to a defined protocol. Univariate and multivariate analysis was used to identify independent predictors of 30-day and overall medium-term mortality. Definitions and analyses were in accordance with joint STS/AATS guidelines. RESULTS: A total of 103 patients (57 males, 46 females; mean age 79.8 years; range: 75-91 years) underwent AVR with a either a Toronto stentless porcine valve (size range: 21-29 mm; n = 74) or an aortic homograft (n = 29). Twenty-eight patients (27%) had either urgent/emergency surgery, 12 (11%) underwent redo surgery, and in 54 cases (52%), the preoperative left ventricular function was significantly impaired (ejection fraction <50%). Forty patients (39%) also underwent concomitant coronary artery bypass grafting. The mean cross-clamp and cardiopulmonary bypass times were 105+/-22 min and 144+/-47 min, respectively. The overall 30-day mortality was 11.6% (n = 12). The 30-day mortality for all elective cases was 5.3%, but for isolated elective AVR was only 2.5%. Using a multivariate model, the only independent predictor of 30-day mortality and medium-term overall mortality was increasing age. The mean follow up period was 3.6 years (range: 0.1-9.3 years), and the Kaplan-Meier actuarial five-year survival was 52%. At follow up, 92% of patients were in NYHA functional classes I and II. CONCLUSION: Stentless AVR in elderly patients is associated with excellent functional and survival outcome in the medium term. Furthermore, in elective cases, age alone should not be a deterrent to the routine use of stentless aortic valves.
Alexander the Great died in 323 B.C. from an unknown cause. Physical depictions of this historical figure reveal the likelihood of a cervical scoliotic deformity. This is substantiated with the medical history and is correlated with his untimely death. For the first time, it is concluded that Alexander's death may have ensued from the sequelae of congenital scoliotic syndrome.
The case of a 42-year-old female requiring surgical management of aortic regurgitation, secondary to Takayasu's disease, with a co-existing heavily calcified ascending aorta is described. In order to address aortic valve surgery with such calcific disease affecting the ascending aorta and peripheral vessels, we present a simple and safe technique that allows aortic valve replacement using a vascular intra-aortic occlusion catheter.
BACKGROUND: At present there is little reported experience in the application of new technology in the performance of distal coronary anastomoses in the clinical setting. The aim of our study was to evaluate the feasibility of using the Ventrica magnetic vascular positioner (MVP) device for left internal thoracic artery (LITA)-to-left anterior descending (LAD) coronary anastomosis. METHODS: We present our preliminary experience of the first 14 coronary artery cases performed in the United Kingdom from April 2003 to December 2003. The selection criteria, surgical technique, clinical outcome, advantages or disadvantages, and future implications are all discussed. RESULTS: The device was used in 12 patients for LITA-to-LAD anastomosis and in 2 patients for the proximal anastomosis of a radial artery Y-graft from the LITA to the circumflex territories. The first 3 patients underwent coronary artery bypass graft with the use of cardiopulmonary bypass, and the remaining 9 underwent surgery performed using an off-pump coronary artery bypass technique. No mortality or device-related events were observed in these patients. The anastomosis time in our series was 5.6 +/- 1.99 minutes, and the blood loss was 914 +/- 234 mL. The mean length of stay was 5.8 +/- 1.16 days. CONCLUSION: The MVP system is a novel distal coronary anastomotic device that is quick, simple, and effective, producing consistently reliable coronary anastomoses in a wide variety of coronary bypass procedures. Early results are encouraging, and further studies are required in order to evaluate long-term efficacy of this system in the rapidly changing world of coronary revascularization.
Explore the source record for details and available documents.
The role of radial artery as an arterial conduit for myocardial revascularisation is well established. Minimally invasive approaches for the harvesting of conduits are desirable for clinical and cosmetic reasons. We report our experience with two techniques of endoscopic radial artery harvesting. The techniques are illustrated and their relative advantages discussed.
We report the case of a 35-year-old female with acute massive right pulmonary embolism, successfully treated by a minimally invasive off-pump pulmonary embolectomy-the first case in the literature implemented via the J-ministernotomy.
BACKGROUND AND AIM OF THE STUDY: Stentless porcine valves in the aortic position exhibit similar excellent hemodynamic performance to homografts, but have the advantage of availability. Their performance was compared over a 10-year period in a single-surgeon and single-institution series. METHODS: Demographic, operative and mortality data were obtained retrospectively. Survivors were interviewed by telephone according to a defined protocol. Definitions and analyses were in accordance with joint STS/AATS guidelines. RESULTS: A total of 408 stentless porcine and homograft aortic valve replacements (AVR) was performed between 1991 and 2001. Five patients were excluded due to incomplete data, in addition to 82 patients who underwent AVR with a free-standing root replacement technique. Hence, 321 patients (217 males, 104 females; mean age 67 +/- 12 years) had a subcoronary implant. The median time to follow up was 4.9 years (range: 2.9-6.6 years). No differences were noted between homograft and stentless porcine valves in one- and five-year freedom from structural valve deterioration (99.1 versus 97.2% and 95.7 versus 93.1%; p = 0.10), reoperation (99.2 versus 99.4% and 97.8 versus 96.7%; p = 0.45) and endocarditis (98.3 versus 99.4% and 97.4 versus 99.4%; p = 0.14). Overall one- and five-year survival comparing homograft to stentless porcine valve was 90.4 versus 92.3% and 80.8 versus 73.7%, respectively; p = 0.23. Independent predictors of mortality on multivariate analysis were: ventricular function (p < 0.0001), increasing age (p < 0.001), increasing serum creatinine (p < 0.001) and concomitant coronary surgery (p = 0.05). Treated hypercholesterolemia was independently protective against mortality, with an odds ratio of 0.26 (CI 0.10 to 0.66; p = 0.005). CONCLUSION: The porcine stentless valve, when implanted in the subcoronary position, is an excellent alternative to the homograft and shows excellent clinical performance and durability at mid term.