Search PubMed⌕ Search

Biomedical subjects

Howard S An

Publications and source records attributed to Howard S An.

At least 55 records · Page 3Linked to original sources

Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method.

STUDY DESIGN: Axial pullout tests using fresh cadaveric thoracolumbar vertebral bodies. OBJECTIVES: To evaluate the effect of a new injectable calcium phosphate cement on the axial pullout strength of both revised and augmented pedicle screws in comparison with polymethyl methacrylate and in terms of injection method. SUMMARY OF BACKGROUND DATA: Failure of pedicle screws by loosening and back out remains a significant clinical problem and is of particular concern for patients with low bone quality. Polymethyl methacrylate was shown to significantly improve the screw pullout strength. However, polymethyl methacrylate is known to have a high polymerization temperature, which may damage surrounding tissues, and a short handling time, and it lacks long-term biocompatibility. Bone mineral cements such as calcium phosphate have a longer working time, very low thermal effect, and are biodegradable as well as having good mechanical strength. Recently, new calcium phosphate cement with improved infiltration properties for better injectability has been introduced, but its performance in augmenting the pedicle screw fixation has not been tested yet. METHODS: The bone mineral densities of 52 vertebral bodies (T11-L5) were measured using dual-energy x-ray absorptiometry. In each vertebral body, a 6.5-mm-diameter and 45 +/- 5-mm-long pedicle screw was inserted into either the right or left pedicle, representing an initial intact implantation. These intact screws were pulled axially until failure at 10 mm/min. Following failure of the intact pedicle, 3.0 cc of cement was injected into the failed screw hole, representing a revision case, and the prepared screw hole in the contralateral intact pedicle representing an augmentation case. The cement was injected either to the distal tip of the screw hole (calcium phosphate-1 group, n = 19) or along the entire length of the screw hole (calcium phosphate-2 group, n = 20), and the screws were inserted. The cement was then allowed to cure for 24 hours at room temperature before both screws were pulled to failure. In 13 specimens, polymethyl methacrylate was injected along the entire length of the screw hole (polymethyl methacrylate group). Kruskal-Wallis and Mann-Whitney tests were used to compare the screw pullout strengths for study groups, whereas linear relationships between variables were assessed with scatter plots and Spearman correlation coefficients with a significance level of 0.05. RESULTS: Mean bone mineral densities of all groups were similar. A significant positive correlation was seen between bone mineral density and intact pullout strength. In revision, the pullout strength of calcium phosphate-1 was similar to that of intact, whereas the pullout strength of calcium phosphate-2 and polymethyl methacrylate was significantly greater than that of intact. In augmentation, all 3 injection methods significantly improved the pullout strength over intact. Injection of the calcium phosphate cement along the entire screw length was found to produce significantly higher pullout strengths than injection only at the distal tip of the screw in revision case. Injection of polymethyl methacrylate produced significantly higher pullout strengths than the injection of calcium phosphate by either method in both revision and augmentation. CONCLUSION: Results of this study demonstrate that the new calcium phosphate cement can improve the axial pullout strength of revised and augmented pedicle screws when injected along the entire length of the screw. This suggests that the injection method may be crucial for revision of failed pedicle screws. Considering inherent properties more favorable for in vivo application, such as nonexothermal polymerization and longer working time, and significant improvement in pullout strength, the new calcium phosphate cement may be a good alternative to polymethyl methacrylate for the augmentation of pedicle screw fixation.

Aged↗

Enhancement of stability following anterior cervical corpectomy: a biomechanical study.

STUDY DESIGN: An in vitro biomechanical study of various reconstructive techniques following decompression of the spondylotic cervical spine. OBJECTIVE.: To evaluate the biomechanical stability of anterior cervical plate fixation following three strategies of decompression for multilevel cervical spondylosis (three levels) of the cervical spine: three level discectomy, single corpectomy and discectomy, and a two-level corpectomy. SUMMARY OF BACKGROUND DATA: The main goals of surgical treatment for cervical myelopathy include adequate decompression and stabilization while maintaining or restoring cervical lordosis. Cervical decompression is often performed through a corpectomy followed by strut-graft reconstruction. An anterior cervical plate with end-fixation (two points of fixation) is then used to span the construct. The authors propose an alternative to multilevel corpectomy and long-segment end construct plate fixation. Often times, the cervical stenosis is confined to the area of the degenerative discs. As a result, the authors feel that either multilevel discectomy or a corpectomy combined with discectomy followed by segmental plate fixation may provide adequate decompression with increased biomechanical rigidity as compared to cervical plate-constructs with end-fixation only. METHODS: Seven human cadaveric fresh-frozen cervical spines from C1-T1 were utilized. Three-dimensional motion analysis with an optical tracking device was used to determine motion following various reconstruction methods. All seven cervical spines underwent testing in a randomized order. The end construct model consisted of a corpectomy at C4 and C5 with a polymethyl methacrylate strut graft and an anterior cervical PEAK (DePuy-AcroMed) plate. The two segmental constructs also utilized the PEAK plate with one construct undergoing discectomies at C3-C4, C4-C5, and C5-C6 with polymethyl methacrylate interbody grafts and the other segmental construct undergoing a discectomy at C3-C4 and a corpectomy of C5. All specimens underwent a pure moment application of 2 Nm with regards to flexion-extension, lateral bending, and axial rotation. RESULTS.: The three-level discectomy and combined one-level discectomy and corpectomy with segmental fixation was significantly more rigid in flexion-extension and lateral bending than the two-level corpectomy with end-construct plate fixation (P < 0.05). There was no increase in stability during extension between the end construct (two-level corpectomy) reconstruction model and the un-instrumented corpectomy and grafted specimen. No difference was noted between the segmental constructs and the end-construct with regards to axial rotation. CONCLUSIONS: Cervical myelopathy is traditionally treated with a multilevel corpectomy and an end-construct plate fixation spanning the strut graft. A large moment arm is generated at the ends of the construct, potentially leading to plate migration or dislodgment. Often times, adequate decompression can be achieved with either a multilevel discectomy or a combined discectomy and corpectomy with segmental plate fixation. This study clearly demonstrates that segmental plate fixation affords a more biomechanically rigid method of reconstruction with regards to flexion-extension and lateral bending than end-construct plate fixation. The increased rigidity afforded by segmental fixation may significantly decrease the likelihood of plate dislodgement in the setting of anterior instrumentation alone following anterior alone, long segment reconstruction procedures.

Biomechanical Phenomena↗

Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws.

STUDY DESIGN: This study attempts to determine the most biomechanically rigid posterior spinal instrumentation configuration in a burst-fracture calf spine model. OBJECTIVES: To compare the biomechanical stability of contemporary posterior spinal instrumentation in various hook and screw configurations in an unstable calf spine model. SUMMARY OF BACKGROUND DATA: Burst-fractures are relatively common injuries seen in the setting of spinal trauma. The use of posterior-only configurations in the treatment of this deformity has become a much more popular approach because of the relative ease of applying the instrumentation. METHODS: Fresh frozen in vitro study using 10 calf spines involving the T11-S1 vertebral segments. Pure moment forces including flexion, extension, axial rotation, and lateral bending were applied to the top of the spinal column at T11. Testing was first performed on all intact specimens. A corpectomy was then performed at L2. Testing was then repeated on each of the ten specimens after internal fixation with different posterior spinal configurations using ISOLA instrumentation (DePuy AcroMed Inc., Raynham, MA). RESULTS: With regards to flexion-extension and lateral bending, all configurations except for distraction hook-rod construct provided stability greater than the intact spine. The distraction hook-rod configuration failed to control extension (P > 0.05) above the intact specimen. All pedicle screw constructs were more rigid than the hook-rod constructs in axial rotation at the level of injury (P < 0.001). CONCLUSIONS: The motion segment at the corpectomy site is adequately stabilized by contemporary spinal internal fixation configurations tested except for the distraction-hook stabilization. Axial rotation is generally poorly controlled by posterior-only internal fixation. Pedicle screw instrumentation was the most rigid compared with other forms of stabilization in stabilizing a burst-corpectomy defect. Based on this study, pedicle screw configurations are preferred over hook-rod strategies in the posterior stabilization of a burst-corpectomy anterior defect. Among hook-rod configurations, the distraction hook-rod strategy provided the least stability.

Animals↗

The course of the nerve root in the neural foramen and its relationship with foraminal entrapment or impingement in adult patients with lumbar isthmic spondylolisthesis and radicular pain.

The purpose of this study was to demonstrate the course of a nerve root in the neural foramen and its relationship with foraminal entrapment or impingement in 19 adult patients with isthmic spondylolisthesis and radicular pain. Myelo-computed tomography and magnetic resonance imaging showed that the course of the nerve root was normal (ie, medial and then inferior, along the pedicle) in 10 patients and was deviated posteriorly in 9 patients. The patients with a normal nerve root course (N-NRC) had either a bony callus projecting medially into the spinal canal (n = 6) or a low mean percentile of vertebral slip (n = 4; 13.9 +/- 1.3). Those nine patients with a posteriorly deviated nerve root course (PD-NRC) had no medially projecting bony callus in the spinal canal but had a higher mean percentile of vertebral slip (n = 9; 31.5 +/- 10.1; P = 0.005). In the neural foramen, nerve roots of the N-NRC patients were entrapped craniocaudally between the pedicle and superior part of the intervertebral disc. In contrast, nerve roots of the PD-NRC patients were impinged ventrodorsally between the posterosuperior part of the intervertebral disc and either bony callus projecting inferiorly toward the neural foramen or fibrocartilaginous mass arising around the isthmic defect. The foraminal craniocaudal entrapment and ventrodorsal impingement highly agreed with the side of radicular pain (kappa= 0.73, P < 0.001). Our results demonstrate that the medially projecting bony callus and the percentile of vertebral slip affect the course of the nerve root in the neural foramen, which in turn determines the foraminal craniocaudal entrapment or ventrodorsal impingement. These two mechanisms, based on the course of the nerve root, correlate well with the side of radicular pain.

Adult↗

Growth factor osteogenic protein-1: differing effects on cells from three distinct zones in the bovine intervertebral disc.

OBJECTIVE: The objective of this study was to determine if cells isolated from three distinct zones in the bovine intervertebral disc (IVD) differ in their response to growth factor osteogenic protein-1 (OP-1) because of inherent biological differences. The new knowledge gained will help determine if treatment of degenerative disc disease with purified growth factors is effective and will provide guidance in terms of the injection technique and frequency of treatments required. DESIGN: This was an in vitro study measuring the effects of OP-1 on proteoglycan accumulation and synthesis by cells from the nucleus pulposus, inner-annulus fibrosus (inner-AF), and outer-annulus fibrosus (outer-AF) in the bovine IVD. RESULTS: Growth factor OP-1, at 100 ng/ml, stimulated proteoglycan accumulation and resulted in a statistically significant increase in the proteoglycan content of cells derived from three zones of the bovine IVD: 97% in the nucleus pulposus, 40% in the inner-AF, and 75% in the outer-AF. To elucidate the mechanism of enhanced proteoglycan accumulation in response to OP-1, we studied the rate of proteoglycan synthesis and cell proliferation. OP-1 stimulation resulted in a statistically significant increase in the DNA content in cultures containing cells from all three zones of the IVDs: 79% in the nucleus pulposus, 100% in the inner-AF, and 73% in the outer-AF. After dividing by DNA content, OP-1 resulted in a statistically significant increase in the rate of proteoglycan synthesis in the nucleus pulposus (78%) and outer-AF (17%) cells, but the increase in inner-AF cells (23%) did not achieve statistical significance. CONCLUSIONS: OP-1 stimulates proteoglycan accumulation by bovine IVD cells isolated from all three zones of the bovine IVDs. Cells from all three zones proliferated significantly. Individual cells derived from nucleus pulposus and outer-AF, but not those from the inner-AF, synthesized proteoglycans at a significantly faster rate with OP-1 stimulation.

Animals↗

Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corpectomy of the cervical spine.

STUDY DESIGN: An in vitro biomechanical study of several reconstructive techniques after a two-level cervical corpectomy. OBJECTIVES: To evaluate, compare, and quantitate the stability of several reconstructive strategies (anterior, posterior, or anterior/posterior with or without instrumentation) after a multilevel cervical corpectomy. SUMMARY OF BACKGROUND DATA: Several clinical and biomechanical studies have questioned the stability of stand-alone long-segment anterior plate fixation after a multilevel (>or=2) corpectomy. The large cantilever forces generated within the stabilized construct, particularly at the caudal screw-bone interface, have led to plate and screw dislodgement and the need for further surgical intervention. The addition of posterior segmental instrumentation has been shown to improve overall stability and decrease local stresses on the anterior fusion construct (graft and plate). MATERIALS AND METHODS: Seven fresh-frozen cadaveric human cervical spines (C1-T1) were harvested. The C1-C2 and C7-T1 vertebral bodies were embedded in poly-methylmethacrylate (PMMA). Three VICON cameras tracked three-dimensional segmental motions at the ends of the fusion construct after a two-level corpectomy and placement of a strut graft with or without instrumentation. Pure moments (flexion/extension, lateral bending, and axial rotation) were applied to the C1 level of each specimen. The motion segments were loaded to a maximum of 2 Nm using dead weights. Testing was first performed on the intact specimens. Then, a two-level corpectomy at the C4 and C5 levels was performed. A PMMA strut graft was then placed into the corpectomy site. Biomechanical testing was then repeated among three different reconstruction techniques: 1) anterior cervical locking plate (PEAK; Depuy-Acromed, Raynham, MA) with dual unicortical screw fixation at C3 and C6; 2) posterior cervical instrumentation (Summit; Depuy-Acromed) using a 3.0-mm rod with segmental lateral mass screw fixation from C3 to C6; and 3) a combined anterior-posterior instrumentation using the anterior PEAK plate and posterior Summit rod system. RESULTS: In all pure moments tested (flexion/extension/lateral bending/axial rotation) the combined anterior-posterior instrumentation reconstruction model and the posterior-only instrumentation model were significantly more rigid than the anterior-only instrumentation model (P < 0.05). Interestingly, no statistically significant difference was noted between the combined anterior plate/posterior instrumentation model and the posterior instrumentation-only model. CONCLUSION: The biomechanical results obtained suggest that posterior segmental instrumentation confers significant stability to a multilevel cervical corpectomy regardless of the presence or absence of anterior instrumentation. In cases in which the stability of a multilevel reconstruction procedure is tenuous, the surgeon should strongly consider the placement of segmental posterior instrumentation to significantly improve the overall stability of the fusion construct.

Biomechanical Phenomena↗

Intradiscal electrothermal therapy: a treatment option in patients with internal disc disruption.

STUDY DESIGN: A literature review was conducted. OBJECTIVES: To review the anatomy, pathophysiology, diagnosis, procedure, and clinical results of intradiscal electrothermal therapy (IDET). SUMMARY OF BACKGROUND DATA: Low back pain is a major physical and socioeconomic entity. A significant percentage of low back pain is attributable to internal disc disruption. The management of internal disc disruption has traditionally been limited to either conservative treatment or spinal fusion. IDET has been performed as an alternative to these therapies. METHODS: The available literature was reviewed. RESULTS: Scientific data regarding the pathophysiology, biologic effects, and clinical results are relatively scarce. Early biomechanical and histologic investigations into the effects of IDET are conflicting. However, in early prospective human trials, IDET seems to provide some benefit with little risk. CONCLUSIONS: IDET is potentially beneficial treatment for internal disc disruption in carefully selected patients as an alternative to spinal fusion. More basic science and clinical research with long-term follow-up evaluation is necessary.

Clinical Trials as Topic↗

Effects of slip severity and loading directions on the stability of isthmic spondylolisthesis: a finite element model study.

STUDY DESIGN: Using a validated finite element model, the biomechanical effects of pars defect in a lumbar segment with and without different degrees of slip (up to 50% slip) were studied. OBJECTIVES: To study the effects of slip severity and loading parameters on the stability of the lytic and adjacent motion segments. Better knowledge of the biomechanics of spondylolisthesis may help formulate treatment strategies such as bracing or spinal implants. SUMMARY OF THE BACKGROUND DATA: Clinically, spondylolisthesis exists in varying grades of anterior slip, and the biomechanical stability of the motion segments at the lytic defect and adjacent level probably varies as well. In vitro studies of L4-L5 and L5-S1 isthmic spondylolisthesis slips have concluded that an L4-L5 pars defect is more unstable than an L5-S1 pars defect. Comparing the stability of lytic motion segments with different grades of spondylolisthesis is difficult to do experimentally and therefore has not been done. Further assessing the stresses in the bone and intervertebral discs at or adjacent to a lytic defect is also difficult to study experimentally, so no data are available. METHODS: A finite element model of L4-S1 was validated with and without a pars defect at L5. The model was then revised to represent different degrees of slip at L5, and six different moment loadings were applied. RESULTS: The current study showed larger decrease in stiffness with increasing percent slip. The decrease in disc stiffness and increase in disc stresses with increasing percent slip were larger at the level of spondylolisthesis as compared to the changes in the adjacent segment. Lateral bending moment and torsion load showed the largest decrease in stiffness due to slip. At 50% slip, the maximum increase in motion (as compared to motion in an intact segment) was seen under lateral bending moment load (about 55% at L4/L5 and 250% at L5/S1). Lateral bending also produced the largest increase in stresses due to 50% slip in the anulus and endplates (300% increase in anular stress and 190% increase in endplate stress) at L5/S1. CONCLUSIONS: The stiffness of a spondylolisthetic motion segment decreases as the slip increases. Lateral bending and torsion are moment directions causing the greatest resulting motions.

Biomechanical Phenomena↗

The origin of chondrocytes in the nucleus pulposus and histologic findings associated with the transition of a notochordal nucleus pulposus to a fibrocartilaginous nucleus pulposus in intact rabbit intervertebral discs.

STUDY DESIGN: Intact rabbit lumbar intervertebral discs were examined histologically. OBJECTIVES: To demonstrate the origin of chondrocytes in the nucleus pulposus, and to document histologic findings associated with the transition of a notochordal to a fibrocartilaginous nucleus pulposus. SUMMARY OF BACKGROUND DATA: A human nucleus pulposus undergoes a chronological transition from a notochordal to a fibrocartilaginous nucleus pulposus. However, the origin of chondrocytes forming fibrocartilage in the nucleus pulposus and the mechanisms of transition remain unknown. METHODS: Hematoxylin-eosin- and safranin O-stained slides obtained from 125 intact rabbit intervertebral discs were observed with light and polarized light microscopy. RESULTS: Of the 125 intervertebral discs examined, 58 had a notochordal nucleus pulposus. The remaining intervertebral discs had a nucleus pulposus with fibrocartilage lamellas or fibrocartilage fibers. All forms of fibrocartilage lamellas and fibers found in the nucleus pulposus were formed by chondrocytes that had originated and migrated from the cartilage endplate. The origin of chondrocytes proceeded in a centripetal direction from the periphery toward the center of the cartilage endplate. The newly formed fibrocartilage lamellas and fibers, therefore, initially involved replacement of the peripheral regions of the nucleus pulposus, followed by replacement of the central region. This centripetal sequential replacement mechanism decreased the size of the notochordal tissue while increasing the lamellar structure of the intervertebral disc. CONCLUSIONS: Chondrocytes in the intact rabbit nucleus pulposus originated and migrated from the cartilage endplate. The chondrocytes changed notochordal nucleus pulposus into fibrocartilaginous nucleus pulposus by depositing fibrocartilage lamellas and fibers in a centripetal direction.

Animals↗

Operative treatment of the patient with neck pain.

Most patients with axial neck pain and cervical radiculopathy can be managed conservatively. Surgical intervention for radiculopathy is considered only when conservative management has failed unless the neurologic deficits are very significant. In cases of myelopathy, surgery may be considered earlier, but if the myelopathy is mild, conservative treatment and close observation are still appropriate. For patients with axial neck pain, surgery is generally not considered except for rare cases caused by single- or two-level degenerative disk disease with severe and unrelenting pain. There are many surgical options for the patients with the degenerative cervical spine, but the indications are different. Surgical intervention involves a complete understanding of the disease process both from physical examination and from radiographic studies. If surgery is undertaken without appropriate clinical correlation, poor results often occur. Although the operative planning is the responsibility of the surgeon. the referring physician should also have some awareness of the basic principles behind the different surgeries.

Cervical Vertebrae↗

Posterior decompressive procedures for the cervical spine.

Cervical degenerative disease encompasses a complex array of pathologies. Before considering surgical intervention, the surgeon should have a complete understanding of the indications for surgery and should have conducted a thorough physical examination and evaluation of radiologic studies. In general, unless myelopathy is present, surgery should be the treatment of last resort, used only after conservative measures have failed. The indications for posterior cervical decompression include both radiculopathy and myelopathy. However, these conditions alone are not sufficient to indicate that a posterior procedure is appropriate. Other factors, such as bilaterality of symptoms, presence or absence of cervical lordosis, number of levels involved, and presence of axial neck pain, should also be considered when deciding whether an anterior procedure or posterior decompression is more appropriate.

Cervical Vertebrae↗

Microsurgery for degenerative conditions of the cervical spine.

Although the operating microscope has been used for spine surgery for more than 20 years, its use is still not widely accepted by orthopaedic spine surgeons. Nevertheless, surgeons who have used the operating microscope are well aware of its many advantages in performing spine surgery. Most notably, the superior visualization it provides allows for faster, safer, and more extensive decompressions. The reluctance of many surgeons to use the operating microscope often has to do with trepidation regarding new technology. The use of the operating microscope when performing anterior and posterior cervical spine surgery makes these procedures easier to carry out and decreases the risk of complications during decompression of the spinal cord.

Cervical Vertebrae↗

Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion.

STUDY DESIGN: A biomechanical study was performed using cadaveric cervical spine specimens. OBJECTIVE: To determine the effect of cervical spine fusion on adjacent-level intradiscal pressure. SUMMARY OF BACKGROUND DATA: Clinical studies have reported that patients with spinal fusion are at greater risk of pathology and early disc degeneration at adjacent levels. It is hypothesized that eliminating motion at one level leads to hypermobility and increased forces at adjacent levels, thus increasing the rate of disc degeneration. METHODS: Six cadaveric cervical spine specimens were tested. Specimens were stabilized at T1 and loaded at C3 to 20 degrees of flexion and 15 degrees of extension. Intradiscal pressures and segmental motion at C4-C5 and C6-C7 were recorded first on intact specimens, and then after anterior cervical plating at C5-C6. Changes in intradiscal pressure and segmental motion were calculated and statistically analyzed using a paired Student t test. RESULTS: Intradiscal pressures were significantly increased during flexion at both adjacent levels. The pressure increased by 73.2% at C4-C5 (P = 0.002), and by 45.3% at C6-C7 (P = 0.006). Intradiscal pressures increased at both adjacent levels during extension, but not significantly. During flexion, segmental motion increased at both adjacent levels, with greater increases at C4-C5. During extension, segmental motion increased at both adjacent levels, with greater increases at C6-C7. CONCLUSIONS: Clinical studies have reported increased rates of disc degeneration at levels adjacent to fusion. It is believed that eliminating motion through fusion shifts the load to the adjacent levels, causing earlier disc degeneration. This study has shown that significant increases in intradiscal pressure and segmental motion occur at levels adjacent to fusion during normal range of motion. These results may partially explain the mechanism of early disc degeneration at levels adjacent to cervical spine fusion.

Biomechanical Phenomena↗

Changes in mRNA and protein levels of proteoglycans of the anulus fibrosus and nucleus pulposus during intervertebral disc degeneration.

STUDY DESIGN: This study correlates the mRNA and protein levels of large and small proteoglycans with the morphologic grade of degeneration. OBJECTIVES: To investigate changes in mRNA and protein levels of aggrecan, versican, biglycan, decorin and fibromodulin in the anulus fibrosus and the nucleus pulposus at different stages of tissue degeneration. SUMMARY OF BACKGROUND DATA: Proteoglycans are found in both the anulus fibrosus and nucleus pulposus and contribute to the hydration of the tissue (aggrecan) and the regulation of matrix assembly (small proteoglycans). Changes in their abundance may influence the biochemical and biomechanical properties of the disc and may have an effect on disc function. METHODS: Thirty-four human lumbar intervertebral discs were graded using Thompson's morphologic scale. The mRNA and protein content of aggrecan, versican, biglycan, decorin and fibromodulin was measured in extracts of anulus fibrosus and nucleus pulposus tissues dissected from these specimens. Protein levels were analyzed by Western blotting, and mRNA levels were semiquantified by reverse transcription polymerase chain reaction. RESULTS: In the anulus fibrosus, the mRNA and protein content of all proteoglycans was significantly elevated at early stages of degeneration then declined in severely degenerated tissues. In contrast, matrix components in the nucleus pulposus showed a continuous decrease in content with increasing grade of degeneration. CONCLUSIONS: Cells of the anulus fibrosus and nucleus pulposus react to tissue degeneration differently. Decreased mRNA expression by nucleus pulposus cells and declining protein content of the matrix make the nucleus more vulnerable to degeneration than the anulus. The cells in the anulus fibrosus respond to early degeneration by upregulating biosynthetic processes. However, in heavily degenerated tissues, the decline in the synthesis of aggrecan and the increase in the concentrations of small proteoglycans may be responsible for the failure of the repair processes.

Aggrecans↗

Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty.

STUDY DESIGN: Destructive biomechanical tests using fresh cadaveric thoracolumbar vertebral bodies. OBJECTIVES: To evaluate the compression strength of human vertebral bodies injected with a new calcium phosphate (CaP) cement with improved infiltration properties for augmentation of the vertebral bodies before compression fracture and also for vertebroplasty in comparison with polymethylmethacrylate (PMMA) injection. SUMMARY OF BACKGROUND DATA: Vertebroplasty is the percutaneous injection of PMMA cement into the vertebral body. While PMMA has high mechanical strength, it cures fast and thus allows only a short handling time. Other potential problems of using PMMA injection may include damage to surrounding tissues by a high polymerization temperature or by the unreacted toxic monomer, and the lack of long-term biocompatibility. Bone mineral cements, such as calcium carbonate and CaP cements, have longer working time and low thermal effect. They are also biodegradable while having a good mechanical strength. However, the viscosity of injectable mineral cements is high, and the infiltration of these cements into vertebral body has been questioned. Recently, the infiltration properties of a CaP cement have been significantly improved, which is ideal for the transpedicular injection to the vertebral bodies for vertebroplasty or augmentation of osteoporotic vertebral body strength. METHODS: The bone mineral densities of 30 vertebral bodies (T2-L1) were measured using dual-energy x-ray absorptiometry. Ten control specimens were compressed at a loading rate of 15 mm/min to 50% of their original height. The other specimens had 6 mL of PMMA (n = 10) or the new CaP (n = 10) cement injected through the bilateral pedicle approach before being loaded in compression. Additionally, after the control specimens had been compressed, they were injected with either CaP (n = 5) or PMMA (n = 5) cement using the same technique, to simulate vertebroplasty. Loading experiments were repeated with the displacement control of 50% vertebral height. Load to failure was compared among groups and analyzed using analysis of variance. RESULTS: Mean bone mineral densities of all five groups were similar and ranged from 0.56 to 0.89 g/cm2. The size of the vertebral body and the amount of cement injected were similar in all groups. Load to failure values for PMMA, the new CaP, and vertebroplasty PMMA were significantly greater than that of control. Load to failure of the vertebroplasty CaP group was higher than control but not statistically significant. The mean stiffness of the vertebroplasty CaP group was significantly smaller than control, PMMA, and the new CaP groups. The mean height gains after injection of the new CaP and PMMA cements for vertebroplasty were minimal (3.56% and 2.01%, respectively). CONCLUSION: Results of this study demonstrated that the new CaP cement can be injected and infiltrates easily into the vertebral body. It was also found that injection of the new CaP cement can improve the strength of a fractured vertebral body to at least the level of its intact strength. Thus, the new CaP cement may be a good alternative to PMMA cement for vertebroplasty, although further in vivo animal and clinical studies should be done. Furthermore, the new CaP may be more effective in augmenting the strength of osteoporotic vertebral bodies for preventing compression fractures considering our biomechanical testing data and the known potential for biodegradability of the new CaP cement.

Absorptiometry, Photon↗

Osteogenic protein-1 enhances matrix replenishment by intervertebral disc cells previously exposed to interleukin-1.

STUDY DESIGN: A study of the mechanisms involved in matrix repair by intervertebral disc cells cultured in alginate gel was performed. OBJECTIVES: To determine the effects of osteogenic protein-1 on the extracellular matrix of intervertebral disc cells previously exposed to interleukin-1, which is an in vitro model for degraded extracellular matrix. SUMMARY OF BACKGROUND DATA: Disc degeneration is accompanied by a decrease in the content of negatively charged proteoglycans in the matrix. No previous attempt has been made to repair the degraded matrix of the disc. METHODS: Nucleus pulposus and anulus fibrosus cells were isolated from the lumbar discs of New Zealand white rabbits and were separately encapsulated in alginate beads. The alginate beads were cultured with or without osteogenic protein-1 after previous exposure to interleukin-1alpha in the presence of 10% fetal bovine serum. The total contents of proteoglycan, collagen, and DNA in the alginate beads were measured. The rate of proteoglycan synthesis by the encapsulated cells was also determined. RESULTS: Treatment with interleukin-1alpha resulted in a significant decrease in proteoglycan and collagen contents in the matrix formed by both the nucleus pulposus and anulus fibrosus. However, subsequent treatment with osteogenic protein-1 led in both cases to rapid recovery of proteoglycans and collagens, whose contents returned to the levels seen in cells not previously exposed to interleukin-1alpha. By the end of the culture period (day 21), those values reached levels higher than those found in beads containing cells never exposed to interleukin-1alpha. Further, the rate of proteoglycan synthesis by both cell types in beads treated with osteogenic protein-1 after previous exposure to interleukin-1alpha was significantly higher than in beads whose cells were not treated with osteogenic protein-1 after previous exposure to interleukin-1alpha. CONCLUSION: Disc cells that have been previously exposed to interleukin-1alpha have lost none of their potential to upregulate proteoglycan synthesis in response to stimulation with osteogenic protein-1. On stimulation with osteogenic protein-1, these disc cells not only replenished the matrix with proteoglycans that had been lost during interleukin-1alpha treatment but proceeded to reform a matrix that was richer in these resilient molecules than that formed by disc cells never exposed to interleukin-1alpha.

Animals↗

Comparison of clinical and radiographic outcome in instrumented anterior cervical discectomy and fusion with or without direct uncovertebral joint decompression.

BACKGROUND CONTEXT: Anterior cervical discectomy and fusion (ACDF) is an established procedure for the operative treatment of cervical disc disease in patients with radiculopathy resulting from impingement from uncovertebral joint osteophytes. Studies demonstrate that direct decompression of the lesion provides good result. However, known complications include vertebral artery injury, dural tears, nerve root injury, loss of biomechanical stability and increased operative time. Other studies suggest that disc space distraction may play an important role by indirectly decompressing neural elements. Therefore, if equivalent functional outcomes can be achieved without sacrificing the uncovertebral joint, then potential morbidity and mortality could be decreased. PURPOSE: To assess and compare clinical and radiographic outcomes of patients with neck pain and cervical radiculopathy who underwent instrumented ACDF with or without direct uncovertebral joint decompression. STUDY DESIGN/SETTING: Retrospective clinical chart and radiographic review to assess clinical outcome and graft fusion in 109 patients who underwent one- or two-level ACDF with rigid anterior plate fixation. PATIENT SAMPLE: Radiographs and clinical charts for 109 patients (mean, 46 years; range, 27 to 83) who underwent ACDF with rigid anterior plate fixation were retrospectively reviewed at a single institution. Patients with radiculopathy resulting from herniated disc, spondylosis or a combination of both refractory to conservative treatment underwent surgery using a standard Smith-Robinson left-sided approach. Seventy-one patients who received direct uncovertebral joint decompression (Group 1) were compared with 38 patients without direct decompression but indirect decompression by disc space distraction (Group 2). In Group 1, 37 one-level and 34 two-level ACDFs were performed. In Group 2, 11 and 27 were one-level and two-level ACDFs, respectively. Smoking and work-related injuries involved 26.7% and 38.0% of Group 1 and 28.9% and 28.9% of Group 2, respectively. Autologous iliac crest grafts were used in 51 patients, whereas 58 patients received allograft. OUTCOME MEASURES: Independent blinded analyses of plain lateral neutral, flexion and extension radiographs were conducted to assess fusion, evaluate graft and plate and screw integrity (mean, 12 months). Clinical outcomes were reported as excellent, good, fair or poor (mean, 23 months) based on Odom's criteria. METHODS: Postoperative clinical outcome and radiographic studies of graft and instrument integrity were assessed in 71 patients undergoing ACDF with uncovertebral joint decompression and 38 patients without uncovertebral joint decompression, but with indirect decompression through disc space distraction. RESULTS: Fusion occurred in 95.8% of Group 1 and 100% of Group 2. In Group 1, 26.8% of the patients reported excellent results, 57.7% reported good results, 12.7% reported fair results and 2.8% reported poor results. In Group 2, 23.7% of the patients reported excellent results, 60.5% reported good results and 15.8% reported fair results. All nonunions reported good outcomes. Postoperative respiratory distress developed in one patient and dysphagia developed in another both from Group 1. No other complications were noted. The presence or absence of direct uncovertebral joint decompression and clinical outcome was not statistically significant (p>.05). The use of graft-type, operative level, presence of smoking and work-related injury in relation to clinical outcome was not found to be significant (p>.05). CONCLUSION: Good to excellent results were obtained in 84.5% and 84.2% of patients for Groups 1 and 2, respectively. Indirect foraminal decompression through distraction remains somewhat controversial during ACDF. However, sacrificing the uncovertebral joint can increase operative time and potentially increase complication rates. This study demonstrates that ACDF with or without direct uncovertebral joint decompression can provide good clinical results for neck pain with cervical radiculopathy. Therefore, routine direct uncovertebral joint decompression should not be undertaken during ACDF.

Cervical Vertebrae↗