Search PubMed⌕ Search

Biomedical subjects

Hong-Yuan Chen

Publications and source records attributed to Hong-Yuan Chen.

At least 37 records · Page 2Linked to original sources

Interfacing myoglobin to graphite electrode with an electrodeposited nanoporous ZnO film.

A biocompatible, nanoporous ZnO film was prepared on graphite electrode by the simple electrodeposition method. Based on the film's strong adsorption ability and friendly microenvironment, it can be used as a good matrix to immobilize myoglobin (Mb) through simple adsorption. Moreover, the entrapped Mb realized direct electron transfer with the electrode and displayed an elegant catalytic activity toward the reduction of hydrogen peroxide, nitrite, and trichloroacetic acid, by which the mediator-free biosensors could be fabricated. Atomic force microscopy, UV-Vis spectra, electrochemical impedance spectroscopy, and cyclic voltammetry, etc. were used to characterize the nanoporous ZnO film and Mb-modified ZnO film. Compared to other methods, electrodeposition of porous material supplied a more simple and convenient approach to prepare biocompatible materials for biosensors.

Adsorption↗

Electroosmotic flow in poly(dimethylsiloxane) microchannels.

This paper reports on the study of electroosmotic flow (EOF) in poly(dimethylsiloxane) (PDMS) microchannels on the basis of indirect amperometric detection method. Gradual increase of EOF rate in freshly prepared PDMS microchannels was observed with the running buffer of phosphate buffer solution (PBS). With the same concentration (10 mM) of PBS containing different cations and the same pH value (7.0) and, the time of the stable EOF in PDMS microchannels under the applied separation voltage of 1000 V was 49.8 s (Li+ -PBS), 57.1 s (Na+ -PBS), 91 s (K+ -PBS), respectively. Meanwhile, the different adsorption of cations (Li+, Na+ and K+) on hydrophobic PDMS wall was observed through their separation in PDMS microchannels. Such experimental results demonstrated that the EOF in PDMS microchannels came from the cations and anions adsorbed on PDMS wall. This study would not only help us understand the surface state of PDMS, but also provide a useful guidance for establishing the effective surface modification methods in PDMS microchip CE.

Dimethylpolysiloxanes↗

One-dimensional BiPO4 nanorods and two-dimensional BiOCl lamellae: fast low-temperature sonochemical synthesis,characterization, and growth mechanism.

Regular BiPO4 nanorods, for the first time, and BiOCl lamellae have been successfully synthesized via a facile sonochemical method in a surfactant/ligand-free system under ambient air. The as-prepared products are characterized by XRD, TEM, SAED, FE-SEM, HRTEM, and Raman spectroscopy. The effects of pH and ultrasound irradiation on the phase and morphology of the products are studied and the sonochemical formation mechanisms of 1D and 2D structures are discussed. TEM data from samples made after different reaction times suggest an ultrasound-induced nucleation and an oriented-attachment growth mechanism.

Journal Article↗

Simple method for the separation and detection of native amino acids and the identification of electroactive and non-electroactive analytes.

Detection of native amino acids was accomplished using a capillary electrophoresis (CE)-amperometric detection system, in which a single carbon fiber cylinder (CFC) working electrode instead of a carbon fiber disc (CFD) electrode was mounted in the end part of a poly(dimethylsiloxane) (PDMS)/glass hybrid microchannel. Similar to that using CFD working electrode, here, the electrochemical reduction reaction at the working electrode is also coupled from the separation high voltage system, the coupling degree is related to the in-channel length of the CFC. This property simplifies the fabrication procedure of the working electrode and also provides a convenient and sensitive means for the determination of non-electroactive ions by amperometry. The present detection mode is successfully used to electrochemically detect non-electroactive arginine (Arg), threonine (Thr), glutamic acid (Glu) and electroactive cysteine (Cys). Furthermore, by simply changing the detection potential, we can easily distinguish peak mobilities of electroactive amino acids from that of non-electroactive amino acids.

Amino Acids↗

Fabricating gold nanoparticle-oxide nanotube composite materials by a self-assembly method.

Composition of nanostructured metal particles on oxide tubes (TiO2 and ZrO2) were fabricated and characterized. The composite materials were examined by transmission electron microscopy, scanning electron microscopy, FT-IR absorption, and UV-visible absorption spectra. The results of characterization showed that the composites indeed contained both oxide tubes and gold nanoparticles and that the gold nanoparticles were intimately associated with the nanotubes.

Journal Article↗

Multilayer membranes via layer-by-layer deposition of organic polymer protected Prussian blue nanoparticles and glucose oxidase for glucose biosensing.

Polyelectrolyte multilayers (PEMs) are now widely used for bioanalytical applications. In this work, a bilayer of poly(diallydimethylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS) is consecutively adsorbed on 3-mercapto-1-propanesulfonic acid modified Au electrode surfaces, forming stable, ultrathin multilayer films. Subsequently, Prussian blue nanoparticles protected by PDDA (denoted as P-PB) and negatively charged glucose oxidase (GOx) are consecutively adsorbed onto the PSS-terminated bilayer. The growth of each of the P-PB/GOx bilayers is followed quantitatively using UV-visible absorption spectroscopy and the electrochemical method. The P-PB nanoparticles can catalyze the electroreduction of hydrogen peroxide formed from enzymatic reaction at lower potential and inhibit the responses of interferents, such as ascorbic acid (AA) and uric acid (UA). Performance of the multilayer films can be tailored by controlling the number of bilayers. Under optimal conditions, a linear range of 0.10 to 11.0 mM and a detection limit of 10 microM were achieved. The glucose biosensor has good stability and reproducibility.

Biosensing Techniques↗

Fabrication of poly(dimethylsiloxane) microfluidic system based on masters directly printed with an office laser printer.

Applications of poly(dimethylsiloxane) (PDMS)-based microfluidic systems are more popular nowadays. Previous fabrication methods of the masters for PDMS microchannels require complicated steps and/or special device. In this paper, we demonstrated that the toner printed on the transparency film with the office laser printer (1200 dpi) can be used as the positive relief of the masters. The transparency film was printed in two steps in order to obtain the same printing quality for the crossed lines. With the laser-printed master, the depth of the fabricated PDMS microchannels was ca. 10 microm and the smallest width was ca. 60 microm. Surface characteristics of the PDMS/PDMS microchannels were performed with SEM. Their electrokinetic properties were investigated by the aids of the measurement of electroosmotic flow (EOF) and the Ohm's curve. Using the PDMS/PDMS microchip CE systems, electroactive biological molecules and non-electroactive inorganic ions were well separated, respectively. This simple approach could make it easy to carry out the studies of PDMS microfluidic systems in more general labs without special devices.

Dimethylpolysiloxanes↗

Separation of caffeine and theophylline in poly(dimethylsiloxane) microchannel electrophoresis with electrochemical detection.

A method for the rapid separation and sensitive determination of caffeine and theophylline was presented in poly(dimethylsiloxane) (PDMS) microchannel electrophoresis integrated with electrochemical detection. By using methanol as an additive, the peak shape and resolution were essentially improved. The analytes were well separated within only 40s in the running buffer of 5.0mM borate solution (pH 9.2) containing 10% (v/v) methanol. The linear ranges were from 6microM to 0.6mM and the detection limits were 4microM for caffeine and theophylline, respectively. The proposed method has been successfully applied to determine caffeine and theophylline in rat serum and urine.

Animals↗

Direct electrochemistry and electrocatalysis of heme proteins immobilized on gold nanoparticles stabilized by chitosan.

Three heme proteins, myoglobin, hemoglobin, and cytochrome c, have been adsorbed onto chitosan-stabilized gold nanoparticles (Chit-Aus) modified Au electrode via a molecule bridge like cysteine. UV-vis spectra indicated that the proteins on Chit-Aus films retained near-native secondary structures. The fabricated procedures and electrochemical behaviors of proteins on such an interface were characterized with electrochemical impedance spectra and cyclic voltammetric techniques. It was demonstrated that Chit-Aus film could not only offer a friendly environment to immobilize protein molecules but also enhance the electron transfer ability between protein molecules and underlying electrode. The effects of scan rate and pH on the electrochemical behaviors of each heme protein are discussed in detail. The resultant electrode displayed an excellent electrocatalytic response to the reduction of H(2)O(2), long-term stability, and good reproducibility.

Animals↗

Electrochemically deposited chitosan hydrogel for horseradish peroxidase immobilization through gold nanoparticles self-assembly.

A new strategy for immobilization of horseradish peroxidase (HRP) has been presented by self-assembling gold nanoparticles on chitosan hydrogel modified Au electrode. From a mildly acidic chitosan solution, a chitosan film is electrochemically deposited on Au electrode surface via a negative voltage bias. This process is accompanied by the hydrogen evolution reaction, and the released hydrogen gas made the deposited chitosan film with porous structure, which facilitates the assembly of gold nanoparticles and HRP. The resulting substrates were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). The immobilized HRP displayed an excellent catalytic property to the reduction of H2O2 in the presence of methylene blue mediator. The resulting biosensor (HRP-modified electrode) showed a wide dynamic range of 8.0 microM-15 mM H2O2, and the linear ranges were 8.0 microM-0.12 mM and 0.50-12 mM, with a detection limit of 2.4 microM estimated at a signal-to-noise ratio of 3. Moreover, the biosensor remained about 85% of its original sensitivity after four weeks' storage.

Animals↗

Extended-range glucose biosensor via layer-by-layer assembly incorporating gold nanoparticles.

We report on a glucose oxidase (GOx)/polyelectrolyte (PE)/gold nanoparticle (AuNP) multilayer films that can be utilized as efficient glucose biosensors by layer-by-layer self-assembly method. Electrochemical impedance spectroscopy (EIS) and UV-visible spectroscopy were adopted to monitor the regular growth of the multilayer films. The role of gold nanoparticles integrated in the multilayer films not only increase the amount and activity of GOx, but also significantly improve the electron-transfer characteristics of the films. The performance of the multilayer films for sensing glucose could be tailored by controlling the gold nanoparticles loading in the film and the number of layers. A biosensor constructed by four poly(dimethyldiallylammonium chloride) (PDDA)/AuNP/PDDA/GOx multilayer films exhibited a wide linear calibration range from 0 to 60.0 mM with the detection limit of 3.0 microM for the detection of glucose. The dynamic range can be extended up to 120 mM. The biosensor has good stability and reproducibility.

Absorption↗

A novel glucose biosensor based on the nanoscaled cobalt phthalocyanine-glucose oxidase biocomposite.

We report on the utilization of a novel nanoscaled cobalt phthalocyanine (NanoCoPc)-glucose oxidase (GOD) biocomposite colloid to create a highly responsive glucose biosensor. The biocomposite colloid is constructed under enzyme-friendly conditions by adsorbing GOD molecules on CoPc nanoparticles via electrostatic interactions. The glucose biosensor can be easily achieved by casting the biocomposite colloid on a pyrolytic graphite electrode (PGE) without any auxiliary matter. It has been found that GOD can be firmly immobilized on PGE surface and maintain its bioactivity after conjugating with NanoCoPc. NanoCoPc displays intrinsic electrocatalytic ability to the oxidation of the product of enzymatic reaction H2O2 and shows a higher catalytic activity than that of bulk CoPc. Under optimal conditions, the biosensor shows a wide linear response to glucose in the range of 0.02-18 mM, with a fast response (5s), high sensitivity (7.71 microA cm(-2) mM(-1)), as well as good thermostability and long-term life. The detection limit was 5 microM at 3 sigma. The general interferences coexisted in blood except ascorbic acid and L-cysteine do not affect glucose determination, and further coating Nafion film on the surface of the biosensor can effectively eliminate the interference from ascorbic acid and L-cysteine. The biosensor with Nafion film has been used for the determination of glucose in serum with an acceptable accuracy.

Biosensing Techniques↗

Analytical aspects of fet-based biosensors.

Field-effect transistor (FET)-based biosensors (BioFETs) have undergone great progress especially in the last decade, since they were first realized in 1980. Recently, BioFETs have become one of the most important branches of biosensors. This paper briefly reviewed the operating principles of BioFETs and summarized the improvement and application of BioFETs, finally, the future prospects of BioFETs were discussed with 126 references.

Biosensing Techniques↗

Reagentless electrochemical biosensor based on the multi-wall carbon nanotubes and nanogold particles composite film.

A novel method was used to prepare the nano-composite by assembling nanogold (NG) particles on the multiwall carbon nanotubes (MWNTs) surface. The nano-composite could be immobilized on a glassy carbon (GC) electrode to get a novel modified electrode. The electrode can easily immobilize the horseradish peroxidase (HRP) molecules to construct a reagentless biosensor. The NG particles in the composite film have a good biological compatibility. And due to the existence of quinone groups on the MWNTs surface, the MWNTs can promote the electron transfer between enzymes and electrode surface. The biosensor shows a good stability and responds to H2O2 in the range from 2.0 microM to 3.5 mM with a detection limit of 1.0 microM.

Biosensing Techniques↗

Tris(2,2'-bipyridyl)ruthenium(II)-zirconia-Nafion composite films applied as solid-state electrochemiluminescence detector for capillary electrophoresis.

The major goal of this work was to develop a new solid-state electrochemiluminescence (ECL) detector suitable for capillary electrophoresis (CE). The detector was fabricated by coating a sol-gel derived zirconia (ZrO(2))-Nafion composite film on a graphite electrode, then the zirconia-Nafion modified electrode was immersed in tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3) (2+)) solution to immobilize this active chemiluminescence reagent. The voltammetric and ECL behaviors of the detector were investigated and optimized in tripropylamine solution. The ratio of 53% for zirconia in the zirconia-Nafion composite provided the highest luminescence intensity of immobilized Ru(bpy)(3) (2+). The ECL can maintain its stability very well in the phosphate solution in the period of 5-90 h when the solid-state ECL detector was immersed in the solution all the time. The optimum distance of capillary outlet to the solid-state ECL detector has been found to be ca. 50-80 microm for a 75 microm capillary. The effects of ionic strength and pH of ECL solution on peak height were investigated. The CE with solid-state ECL detector system was successfully used to detect tripropylamine, lidocaine, and proline. The detection limits (S/N = 3) were 5 x 10(-9) mol.L(-1) for tripropylamine, 1 x 10(-8) mol.L(-1) for lidocaine and 5 x 10(-6) mol.L(-1) for proline, and the linear ranges were from 1.0 x 10(-8) to 1.0 x 10(-5) mol.L(-1) for tripropylamine, 5.0 x 10(-7) mol.L(-1) to 1.0 x 10(-5) mol.L(-1) for lidocaine and 1.0 x 10(-5) to 1.0 x 10(-3) mol.L(-1) for proline, respectively.

Electrophoresis, Capillary↗

In-channel indirect amperometric detection of nonelectroactive anions for electrophoresis on a poly(dimethylsiloxane) microchip.

In the present paper, we describe a microfluidics-based sensing system for nonelectroactive anions under negative separation electric field by mounting a single carbon fiber disk working electrode (WE) in the end part of a poly(dimethylsiloxane) microchannel. In contrast to work in a positive separation electric field described in our previous paper (Anal. Chem. 2004, 76, 6902-6907), here the electrochemical reduction reaction at the WE is not coupled with the separation high-voltage (HV) system, whereas the electrochemical oxidation reaction at the WE is coupled with the separation HV system. The electroactive indicator is the carbon fiber WE itself but not dissolved oxygen. This provides a convenient and sensitive means for the determination of nonelectroactive anions by amperometry. The influences of separation voltage, detection potential, and the distance between the WE and the separation channel outlet on the response of the detector have been investigated. The present detection mode is successfully used to electrochemically detect F-, Cl-, SO4(2-), CH3COO-, H2PO4-. Based on the preliminary results, a detection limit of 2 microM and a dynamic range up to three orders of magnitude for Cl- could be achieved.

Anions↗