High-throughput determination of mono- and di(2-ethylhexyl)phthalate migration from PVC tubing to drugs using liquid chromatography-tandem mass spectrometry.

The risk assessment of di(2-ethylhexyl) phthalate (DEHP) that migrated from polyvinyl chloride (PVC) medical devices is an important issue for hospitalized patients. Many studies have been conducted to determine the level of DEHP migration. A recent report has indicated that DEHP in blood bags was hydrolyzed by esterase to mono(2-ethylhexyl) phthalate (MEHP). Therefore, a method for the simultaneous determination of DEHP and MEHP was developed. The migration of DEHP and MEHP from PVC tubing to drugs was examined. Although we detected MEHP in the drugs, we found no enzymatic activity involved in the migration process. Some reports have indicated that hydrolysis may have occurred during sterilization by autoclaving. However, we did not perform any heat treatment. It is speculated that the MEHP migrated directly from the PVC tubing. The simultaneous determination of DEHP and MEHP is required for risk assessment, as MEHP may be even more toxic than the parent compound.

Chromatography, Liquid↗

Dual derivatization-stir bar sorptive extraction--thermal desorption--gas chromatography-mass spectrometry for determination of 17beta-estradiol in water sample.

A novel method for the trace analysis of 17beta-estradiol (E2) in river water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ acylation (first derivatization) and thermal desorption (TD) with quartz wool assisted (QWA) in tube silylation (second derivatization), followed by gas chromatography-mass spectrometry (GC-MS), and is called the "dual derivatization method." The optimum conditions for SBSE with in situ acylation, such as the volume of acetic acid anhydride and the extraction time, were investigated. In addition, the optimum conditions for TD with QWA in tube silylation, such as the volume of N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and the TD temperature and hold time, were investigated as well. The detection limit (S/N = 3) and the quantitation limit (S/N>10) of E2 in the river water sample were 0.5 and 2 pg ml(-1) (ppt), respectively, by the dual derivatization method. In addition, the detection limit was 0.1 pg ml(-1) by using dual derivatization method with multi-shot mode. The calibration curve for E2 was linear in the range of 0.002-10 ng ml(-1) with correlation coefficients >0.999. The average recoveries of E2 (n = 6) at the concentrations of 0.05 and 1.0 ng ml(-1) from the river water sample were 93.1 (RSD: 1.4%) and 98.4% (RSD: 0.8%), respectively, with correction using the added surrogate standard, 17beta-estradiol-(13)C(4). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of E2 in water samples.

Acylation↗

Development of a simple method for predicting the levels of di(2-ethylhexyl) phthalate migrated from PVC medical devices into pharmaceutical solutions.

This study deals with the development of a simple method for predicting the elution levels of di-2-ethylhexyl phthalate (DEHP) from medical devices made of polyvinyl chloride (PVC) by using the physicochemical properties of pharmaceutical injections as a marker. GC-MS analysis showed that the release of DEHP from medical grade PVC product was concentration-dependently increased by extraction with two kinds of lipophilic injections (Sandimmun and Prograf) and three kinds of surfactants (HCO-60, Tween 80, and SDS). The solubility of lipophilic pigments such as Sudan III, methyl yellow, and 1,4-diamino-anthraquinone against these solutions were also increased in a concentration-dependent manner, in which methyl yellow showed the highest response regarding the increase of optical density (O.D.). Further, electrical conductivity and static contact angle to the PVC sheet of the solutions were also increased or decreased in the same manner. As a result of the comparative study, significant correlation was found between DEHP release levels and these three physicochemical properties, particularly methyl yellow solubility, of the solutions tested. To evaluate the relationship in detail, DEHP release levels from PVC tubing and methyl yellow solubility of 53 injections used in gynecologic and obstetric fields were determined. None of the hydrophilic medicines showed any significant release of DEHP, and all showed low solubility of methyl yellow. On the other hand, the lipophilic medicines releasing a large amount of DEHP showed high solubility of methyl yellow (greater than O.D. 0.8). These results indicate that a significant proportional relationship exists between DEHP release potency and methyl yellow solubility of pharmaceutical solutions, and the risk of DEHP exposure to the patients administered pharmaceuticals through transfusion set could be easily predicted by the solubility test without complicated elution tests of DEHP using GC-MS or LC-MS.

Diethylhexyl Phthalate↗

Stir bar sorptive extraction with in situ de-conjugation and thermal desorption gas chromatography-mass spectrometry for measurement of 4-nonylphenol glucuronide in human urine sample.

4-Nonylphenol glucuronide (NP-G) in human urine samples was analyzed using stir bar sorptive extraction (SBSE) with in situ de-conjugation by beta-glucuronidase and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). Distilled water (1 ml), 1.0 M ammonium acetate solution (100 microl) and beta-glucuronidase (10,000 units ml(-1), 10 microl) were added to human urine sample (1 ml), and extraction was commenced for 90 min at 37 degrees C while stirring at 250 rpm with a stir bar coated with a 500-microm-thick polydimethylsiloxane (PDMS) layer. Then, the stir bar was subjected to TD-GC-MS in the selected ion monitoring (SIM) mode. The calibration curve was made by SBSE method using 4-nonylphenol (NP) as the standard solution. The method showed good linearity and the correlation coefficients were 0.999 over the concentration range of 5-500 nM. Moreover, to optimize the conditions for SBSE with in situ de-conjugation and the recovery test, NP-G was synthesized by a biochemical technique in our laboratory. The limits of detection (S/N = 3) and quantitation (S/N > 10) for NP were 0.2 ng ml(-1) (1.0 nM) and 1.1 ng ml(-1) (5.0 nM), respectively. The average recoveries in the human urine samples (n = 6) spiked with NP-G at levels of 20 and 100 nM were 104.1 (R.S.D. 7.1%) and 100.6% (R.S.D. 9.2%), respectively, with correction using the added internal standard, 4-(1-methyl) octylphenol-d(5). The method enabled the precise determination of the standard and was applicable to the detection of trace amounts of NP-G in human urine samples.

Acetates↗

Systematic analysis and overall toxicity evaluation of dioxins and hexachlorobenzene in human milk.

A systematic method for analyzing dioxins (PCDDs, PCDFs and dioxin-like PCBs), hexachlorobenzene (HCB), heptachlor epoxide and beta-hexachlorocyclohexane (HCH) in human milk was developed to determine the residual amount of HCB in human milk and to evaluate the overall toxicity of both dioxins and HCB in human milk. The fractionation behavior of HCB on chromatography with silica gel, alumina, and activated carbon/silica gel, and the concentrated sulfuric acid decomposition method, which is widely used as a dioxin cleanup method, were studied in order to make the preprocessing operation for HCB measurement compatible with that for conventional dioxin measurement. HCB was found to be eluted in the 2% dichloromethane (DCM)/hexane 60 ml fraction from an alumina column. Heptachlor epoxide and a part of beta-HCH were eluted in the 10% DCM/hexane 50 ml fraction from a silica gel column, while the remaining beta-HCH was eluted in the 25% DCM/hexane 60 ml fraction from an activated carbon/silica gel column. Moreover, HCB showed significant correlation with dioxin congeners having high toxicity equivalence factors (TEFs). The results suggest that the exposure route to HCB and its accumulation behavior in the human body are similar to those of the dioxins.

Chemistry Techniques, Analytical↗

Stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography--mass spectrometry for measurement of phenolic xenoestrogens in human urine samples.

A high-sensitivity analytical method that uses stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) for the simultaneous measurement of trace amounts of phenolic xenoestrogens (PXs), such as 2,4-dichlorophenol (DCP), 4-tert-butylphenol (BP), 4-tert-octylphenol (OP), 4-nonylphenol technical isomers (NP), pentachlorophenol (PCP) and bisphenol A (BPA), in human urine samples was developed. The urine sample (1 ml) was de-conjugated by adding beta-glucuronidase and sulfatase. Then, protein precipitation was performed by the addition of acetonitrile. After centrifugation, the supernatant was diluted with purified water and subjected to SBSE with in situ derivatization and TD-GC-MS. The detection limits of DCP, BP, OP, NP, PCP and BPA in the urine samples were 20, 10, 10, 50, 20 and 20 pg ml-1 (ppt), respectively. The calibration curves for PXs were linear and had correlation coefficients higher than 0.99. The average recoveries of those analytes in the urine samples were higher than 95% (RSD: <10%, n=6) with correction using the added surrogate standards. This simple, accurate, sensitive and selective method can be used in the determination of PXs in human urine samples.

Adult↗

Stir bar sorptive extraction and trace analysis of alkylphenols in water samples by thermal desorption with in tube silylation and gas chromatography-mass spectrometry.

A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples.

Gas Chromatography-Mass Spectrometry↗

Evaluation and analysis of exposure levels of di(2-ethylhexyl) phthalate from blood bags.

BACKGROUND: The US FDA and The Ministry of Health, Labor and Welfare of Japan have indicated that the risk assessment of di(2-ethylhexyl) phthalate (DEHP) released from polyvinyl chloride (PVC) medical devices requires immediate attention. In particular, the analysis of the exposure to DEHP from blood bags is very important for medical treatment. However, human exposure to DEHP via blood transfusion remains poorly understood. We evaluated DEHP and mono(2-ethylhexyl) phthalate (MEHP) levels, migration patterns, and metabolism in blood products for the detailed assessment of exposure to DEHP. METHODS: A method that is based on column-switching liquid chromatography-electrospray mass spectrometry (LC-MS) coupled with on-line extraction was used for the direct analysis of DEHP and MEHP in the blood products. From the Japanese Red Cross Society, 78 blood products (red blood cell concentrate: n=18, irradiated red blood cell concentrate: n=18, whole blood: n=18, blood platelet: n=18, and frozen plasma: n=6) were sampled in January 2003 for use in this study. RESULTS: The detection levels of DEHP and MEHP ranged from 1.8 to 83.2 microg/ml and from 0.1 to 9.7 microg/ml, respectively. The levels of MEHP and DEHP in the blood products were increased with increasing storage time. In addition, whole blood products in PVC bags had the highest DEHP levels compared to the other blood products. Our results indicate that the maximum level of human exposure to DEHP released from blood bags is 0.7 mg/kg weight/time. CONCLUSION: This first quantitative evidence may be useful for the risk assessment of DEHP released from blood bags.

Blood Platelets↗

[Tricresyl phosphate residue in garland chrysanthemum and its origin].

Unknown peaks were detected in the chromatogram of garland chrysanthemum extract in analysis of organophosphorus pesticide residues. The unknown peaks were identified as isomers of tricresyl phosphate (TCP) by GC/MS. TCP is used as a plasticizer in polyvinyl chloride, and there is no report of its detection in foods. Therefore, we investigated the origin of TCP detected in garland chrysanthemum. We found no effect of contact with packaging film or polyvinyl chloride sheet used in greenhouses. However, TCP was detected at 0.03 microg/g (average) in 16 of 20 samples of garland chrysanthemum that had been in contact with polyvinyl chloride tubing used for warming greenhouses. These results indicate that TCP migrated to the garland chrysanthemum from the tubing used to keep greenhouses warm.

Agriculture↗

Development of liquid chromatography-electrospray mass spectrometry for the determination of patulin in apple juice: investigation of its contamination levels in Japan.

Patulin is a mycotoxin produced by mainly Penicillium species, for example, P. expansum, and Aspergillus species. There are several reports of patulin contamination in apple juice. Last year, the Ministry of Health, Labour and Welfare of Japan set the maximum allowable level of patulin in apple juice at 50 ppb and decided that the measurement of patulin levels in apple juice products should be conducted. To this end, a simple, accurate, and selective analytical method for the detection of patulin at levels lower than 5 ppb, the detection limit, is desired. This paper reports the development of an analytical method that employs solid-phase extraction-liquid chromatography-mass spectrometry (SPE-LC-MS). When MS measurements were conducted with the selected ion monitoring (SIM) mode, the pseudomolecular ions at m/z 153 and 156 were used to monitor patulin and (13)C(3)-labeled patulin, respectively. The detection limit (S/N = 3) and the quantification limit (S/N = 10) of patulin at injection levels into LC-MS were 12.5 and 25 pg, respectively. However, when the actual sample was applied for the analysis based on the developed method including the sample preparation, the detection limit (S/N = 3) and quantification limit (S/N = 10) were 2.5 and 5 pg in sample, respectively. The calibration curve obtained for concentrations ranging from 5 to 500 ppb showed good linearity with a coefficient of determination (r (2)) of 0.999. In addition, the recovery was >95% when an internal standard was used. The method was applied to the analysis of 76 apple juice samples from Japan, and as a result, patulin levels ranging from <1.0 to 45 ppb (detection frequency = 15/76) were detected. In this study, it was found that patulin was a greater contaminant in concentration/reduction than in "not from concentrate" apple juice.

Beverages↗

Determination of perfluorooctane sulfonate, perfluorooctanoate and perfluorooctane sulfonylamide in human plasma by column-switching liquid chromatography-electrospray mass spectrometry coupled with solid-phase extraction.

We report a method for determining fluorinated organic compounds such as perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA) and perfluorooctanesulfonylamide (PFOSA) in human blood samples by column-switching liquid chromatography-electrospray mass spectrometry. The sample preparation prior to solid phase extraction (Waters Oasis HLB extraction column) involved simply mixing plasma sample with internal standard followed by centrifugation and extraction. The compounds were separated by reversed-phase chromatography with a C(8) column, and detected by mass spectrometry using selected ion monitoring in the negative mode. The average recoveries of PFOS, PFOA and PFOSA ranged from 82.2 to 98.7% (R.S.D.: from 2.0 to 5.2%, n = 6). The limits of quantitation of PFOS, PFOA and PFOSA at signal to noise (S/N = 10) were 0.5, 0.5 and 1.0 ng ml(-1). The method enables the precise determination of standards and can be applied to the detection of PFOS, PFOA and PFOSA in human plasma samples for monitoring human exposure.

Acetates↗

Stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry in the multi-shot mode for determination of estrogens in river water samples.

A novel method for the trace analysis of natural and synthetics estrogens, such as estrone (E1), 17beta-estradiol (E2) and 17alpha-ethynylestradiol (EE), in river water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ derivatization followed by thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The derivatization conditions with acetic acid anhydride and the SBSE conditions such as sample volume and extraction time were investigated. In addition, the single and multi-shot modes in TD were investigated. The detection limits of E1, E2 and EE in river water sample were 0.2, 0.5 and 1 pg ml(-1) (ppt), respectively, in the multi-shot mode using five stir bars. The calibration curves for E1, E2 and EE were linear and had correlation coefficients >0.99. The average recoveries of E1, E2 and EE from all sample volumes were higher than 90% (R.S.D. < 10%) with correction using an added surrogate standard such as estrone-13C4, 17beta-estradiol-13C4 or 17alpha-ethynylestradiol-13C4. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of estrogens in water samples.

Algorithms↗

Determination of 4-tert.-octylphenol and 4-nonylphenol in laboratory animal feed sample by stir bar sorptive extraction followed by liquid desorption and column-switching liquid chromatography-mass spectrometry with solid-phase extraction.

A novel analytical method has been developed for the determination of 4-tert.-octylphenol (OP) and 4-nonylphenol (NP) in laboratory animal feed samples, which involves stir bar sorptive extraction (SBSE) followed by liquid desorption (LD) and column-switching liquid chromatography-mass spectrometry (CS-LC-MS) with solid-phase extraction (SPE). The method required correction by stable isotopically labeled surrogate standards, deuterium 4-tert.-octylphenol (OP-d) and [2H5] 4-(1-methyl)octylphenol (m-OP-d5). A feed sample was homogenized with methanol by ultrasonication. After centrifugation, the supernatant was subjected to extraction for 120 min at room temperature (25 degrees C) using a stir bar coated with polydimethylsiloxane. After the extraction, the analyte was desorbed from the stir bar by LD using acetonitrile. Then, the liquid sample was analyzed by CS-LC-MS with SPE. The average recoveries from laboratory feed samples spiked with OP and NP at 20 ng g(-1) were 99.5 and 103.8%, respectively, with correction using the added surrogate standards. The limits of quantification were 1 ng g(-1) for OP and 5 ng g(-1) for NP in feed sample. The measurement of OP and NP in commercial laboratory animal feed samples resulted in the detection of sub ng g(-1) NP

Animal Feed↗

Trace analysis of phenolic xenoestrogens in water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry.

A method for the simultaneous measurement of trace amounts of phenolic xenoestrogens, such as 2,4-dichlorophenol (2,4-DCP), 4-tert-butyl-phenol (BP), 4-tert-octylphenol (OP), 4-nonylphenol (NP), pentachlorophenol (PCP) and bisphenol A (BPA), in water samples was developed using stir bar sorptive extraction (SBSE) with in situ derivatization followed by thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) analysis. The conditions for derivatization with acetic acid anhydride were investigated. A polydimethylsiloxane (PDMS)-coated stir bar and derivatization reagents were added to 10 ml of water sample and stirring was commenced for 10-180 min at room temperature (25 degrees C) in a headspace vial. Then, the extract was analyzed by TD-GC-MS. The optimum time for SBSE with in situ derivatization was 90 min. The detection limits of 2,4-DCP, BP, OP, NP, PCP and BPA were 2, 1, 0.5, 5, 2 and 2 pg ml(-1), respectively. The method showed good linearity over the concentration ranges of 10, 5, 2, 20, 10 and 10-1000 pg ml(-1) for 2,4-DCP, BP, OP, NP, PCP and BPA, respectively, and the correlation coefficients were higher than 0.99. The average recoveries of those compounds in river water samples were equal to or higher than 93.9% (R.S.D. <7.2%) with correction using the added surrogate standards. This simple, accurate, sensitive and selective method can be used in the determination of trace amounts of phenolic xenoestrogens in river water samples.

Estrogens↗

Determination of bisphenol A in river water and body fluid samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry.

A new method, based on stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described for the determination of trace amounts of bisphenol A (BPA) in river water, urine, plasma, and saliva samples. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as sample volumes and extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of BPA in river water, urine, plasma, and saliva samples are 1-5, 20, 100, and 20pgml(-1) (ppt), respectively. Calibration for BPA was shown to be linear with a correlation coefficient of >0.99. The average recoveries of BPA in all samples are higher than 95% (R.S.D. < 10%) with correction using an added surrogate standard, 13C12-bisphenol A. This simple, accurate, sensitive, and selective analytical method may be applicable to the determination of trace amounts of BPA in liquid samples.

Benzhydryl Compounds↗

Simultaneous determination of hydrogen cyanide and volatile aliphatic nitriles by headspace gas chromatography, and its application to an in vivo study of the metabolism of acrylonitrile in the rat.

A method for the simultaneous determination of hydrogen cyanide (HCN) and aliphatic nitriles using manual headspace (HS) gas chromatography (GC) with a capillary porous polymer column GS-Q and a nitrogen-phosphorus detector is described. With a HS incubation at 50 degrees C for 30 min and a GC temperature at 180 degrees C, HCN and volatile nitriles [acetonitrile, acrylonitrile (VCN), propionitrile, isobutyronitrile] were well separated and could be detected within 7 min with a detection limit of 0.7-2.4 ng/ml in blood samples. The HS-GC method was used in an in vivo study of VCN metabolism. VCN was administered orally (at nearly one-half its LD(50)) to rats, and heart blood and urine were sampled. Blood concentrations of HCN and VCN were measured by HS-GC, and plasma and urinary thiocyanate concentrations were measured by the König colorimetric method. Blood levels of HCN and VCN peaked 1.5 h after VCN administration, at which time the cyanide level (about 0.7 microg/ml) is close to the fatal level. HCN levels were observed to be at almost background levels at 10 h, although 50 ng/ml VCN was still detectable. The plasma thiocyanate level increased, reaching a peak (about 30 microg/ml) at 5 h. The cumulative urinary thiocyanate amount gradually increased, and at 10 h more than 1 mg thiocyanate was excreted into the urine. It is therefore possible to clarify the cause of cyanide poisoning using HS-GC analysis, when someone has taken volatile nitriles.

Acetonitriles↗

Stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry for the measurement of 4-nonylphenol and 4-tert-octylphenol in human biological samples.

Alkylphenols, 4-nonylphenol (NP) and 4-tert-octylphenol (OP), in human urine and plasma samples were analyzed using stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The method involved correction by stable isotopically labeled surrogate standards, 4-(1-methyl)octylphenol-d5 (m-OP-d5) and deuterium 4-tert-octylphenol (OP-d). A biological sample was extracted for 60 min at room temperature (25 degrees C) using a stir bar coated with a 500 microm thick polydimethylsiloxane (PDMS) layer. Then, the stir bar was analyzed by TD-GC-MS in the selected ion monitoring (SIM) mode without any derivatization step. The average recoveries in human urine and plasma samples spiked with NP and OP at levels of 0.5 and 10 ng ml-1 were between 95.8 and 99.8% with correction using the added surrogate standards. The limits of quantitation were 0.2 ng ml-1 for NP and 0.02 ng ml-1 for OP. We measured the background levels of NP and OP in five human urine and three human plasma samples from healthy volunteers. NP and OP were not detected in all human urine samples (N.D. < 0.2 ng ml-1 for NP, and N.D. < 0.02 ng ml-1 for OP). However, 0.2-0.3 ng ml-1 for NP and 0.1-0.2 ng ml-1 for OP in human plasma samples were observed by this method.

Gas Chromatography-Mass Spectrometry↗

Development of a accelerated solvent extraction and gel permeation chromatography analytical method for measuring persistent organohalogen compounds in adipose and organ tissue analysis.

A new analytical method has been developed for the quantification of 59 different persistent organohalogen compounds, such as polybrominated diphenyl ethers (PBDEs), polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs), PCB metabolites, organochlorine pesticides (OCPs) in biological organ tissues. The optimum extraction and cleanup procedures were examined using accelerated solvent extraction (ASE), automated gel permeation chromatography (GPC) on Biobeads S-X3 and automated solid phase extraction (SPE) on silica-gel. The target compounds were divided into two fractions, non-polar compounds and more polar compounds, which in the latter fraction was subsequently methylated using diazomethane. Detection can be achieved by GC/MS in negative chemical ionization (NCI) mode. The average recoveries of the compounds spiked in swine liver, heart, kidney, and cattle adipose tissues were considered satisfactory, and it was confirmed that the method could be used in routine analysis.