Search PubMed⌕ Search

Biomedical subjects

Hiroyuki Kabasawa

Publications and source records attributed to Hiroyuki Kabasawa.

9 recordsLinked to original sources

Measurement of fractional anisotropy using diffusion tensor MRI in supratentorial astrocytic tumors.

In vivo, water diffusion displays directionality due to presence of complex microstructural barriers in tissue. The extent of directionality of water diffusion can be expressed as a fractional anisotropy (FA) value, using diffusion tensor MR imaging (DTI). The aim of this study was to determine whether FA values indicate microstructures in astrocytic tumors. We performed DTI in 31 patients with astrocytic tumor, and measured the FA values of tumor and normal brain regions prior to CT-guided stereotactic biopsy. After biopsy, FA values were compared to assess the cellularity and vascularity of tumor tissue. Although mean FA values trended to differ among histological types, all mean tumor FA values were lower than those of normal brain regions. Positive correlation was observed between FA values and both cellularity (r = 0.65, p < 0.05) and vascularity (r = 0.45, p < 0.05). We had hypothesized that the FA value of an astrocytic tumor would be determined by a balance between factors increasing the directionality of water diffusion, such as high cellularity and/or vascularity, and factors decreasing the directionality of water diffusion, such as fiber destruction. However, our results suggest that the FA values of glioblastoma, anaplastic astrocytoma, diffuse astrocytoma and pilocytic astrocytoma are largely affected by cellularity and/or vascularity, whereas that of gliomatosis cerebri are largely affected by the preservation of nerve fibers. Measurement of FA value using DTI will allow prediction of histological characteristics such as cellularity, vascularity and/or fiber structure in astrocytic tumors.

Adult↗

[Simple visualization of the corticospinal pathway using tractography: one-ROI and two-ROI methods].

Diffusion tensor imaging (DTI), a magnetic resonance (MR) technique to analyze diffusion anisotropy of the brain, is able to demonstrate subtle white matter anatomy. Tractography is expected to be a unique, non-invasive tool to provide more pertinent insights into brain structure and orientation not accessible by conventional MRI. In this report, preliminary experiences of visualization of the corticospinal tract using tractography are described. DTI of the brain was performed in 5 normal volunteers using single-shot echo-planar imaging, then tractography was generated by our original software. We determined that the two-region-of-interest (ROI) method is superior to the one-ROI method.

Adult↗

Optimal inversion time for acquiring flow-sensitive alternating inversion recovery images to quantify regional cerebral blood flow.

The purpose of this study was to correlate regional cerebral blood flow (rCBF) measured by I-123-IMP and flow-sensitive alternating inversion recovery (FAIR) studies with different inversion time (TI) values to find out the optimum TI that gives comparable rCBF and images on FAIR study. Nine patients with symptoms and signs of internal carotid or major cerebral arterial stenosis were enrolled in this study. Both I-123-IMP single photon emission computed tomography (SPECT) and FAIR images were acquired in all patients. Single-slice FAIR images (with different TI values) were acquired using a 1.5-T MRI unit. The rCBF was calculated from all I-123-IMP and FAIR images. Receiver operating characteristics (ROC) analysis was performed to detect hypoperfused segments on FAIR images. The rCBF calculated from FAIR and I-123-IMP studies were compared and correlated with each other. The ROC analysis showed no significant differences among the readers or TI values, but a trend of higher sensitivity, specificity, and accuracy was observed with TI of 1400 ms. The rCBF values of FAIR and I-123-IMP studies significantly correlated with each other. The FAIR images with TI value of 1400 ms gave more comparable CBF. A TI value of 1400 ms might be optimum for 1.5-T MR strength to get high quality FAIR images and comparable CBF.

Aged↗

Diffusion-weighted echoplanar MR imaging of the salivary glands.

OBJECTIVE: We determined the apparent diffusion coefficients of normal and dysfunctional salivary glands. SUBJECTS AND METHODS: A diffusion-weighted single-shot spin-echo type of echoplanar MR imaging was performed on the parotid or submandibular glands, or both, in 36 healthy subjects, 20 patients with Sjögren's syndrome, and six patients with sialoadenitis. The apparent diffusion coefficient of the salivary gland was calculated using two b factors (b = 500 and 1,000 sec/mm(2)). RESULTS: The apparent diffusion coefficient was lower in the parotid glands (0.28 x 10(-3) mm(2)/sec) than that of the submandibular glands (0.37 x 10(-3) mm(2)/sec). The apparent diffusion coefficient was increased in sialoadenitis, whereas it decreased with abscess formation. The apparent diffusion coefficients of the parotid glands in patients with Sjögren's syndrome correlated with the salivary flow rates but not with the sialographic gradings of the glands. We also found a correlation of the decreases in apparent diffusion coefficients with the severity of gland damage as assessed on T1-weighted MR images. CONCLUSION: Diffusion-weighted echoplanar MR imaging may reveal diseased states of the salivary glands.

Adult↗

Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: comparison with [iodine 123]-iodoamphetamin single photon emission CT.

BACKGROUND AND PURPOSE: Flow-sensitive alternating inversion recovery (FAIR) MR imaging is a technique for depicting cerebral perfusion without contrast enhancement. Our purpose was to determine whether quantification at FAIR imaging can be used to assess regional cerebral blood flow (rCBF) in a manner similar to [iodine 123]-iodoamphetamin ((123)I-IMP) single photon emission CT (SPECT). METHODS: Nine patients with internal carotid or major cerebral arterial stenosis underwent (123)I-IMP SPECT and FAIR imaging (single section, different TIs, 1.5 T) at rest and after acetazolamide (Diamox) stress. FAIR and (123)I-IMP rCBF values were compared and correlated. Receiver operating characteristic analysis was conducted to detect hypoperfused segments on FAIR images. RESULTS: rCBF values of normally perfused segments were 41.53 and 51.91 mL/100 g/min for pre- and post-acetazolamide (123)I-IMP studies, respectively. Corresponding values for pre- and post-acetazolamide FAIR images, respectively, were 46.64 and 59.60 mL/100 g/min with a TI of 1200 milliseconds and 53.23 and 68.17 mL/100 g/min with a TI of 1400 milliseconds. (123)I-IMP and FAIR results were significantly correlated, with both pre- and post-acetazolamide images. Sensitivity (86%) in detecting hypoperfused segments was significantly higher with post-acetazolamide images (TI, 1400 milliseconds), and specificity (82-85%) and accuracy (80-82%) were higher with all pre- and post-acetazolamide images (all TIs). CONCLUSIONS: The significant correlation, high specificity and accuracy in detecting hypoperfused segments, similar increases in flow on both post-acetazolamide images, and absence of the need for contrast enhancement suggest that FAIR imaging, like nuclear medicine study, is complementary to routine MR imaging in the assessment of cerebral perfusion.

Acetazolamide↗

[Evaluation of PROPELLER MR imaging: preliminary experiences].

Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) MR imaging (MRI) has a unique ability to correct motion artifacts and is expected to be useful in diffusion-weighted MRI. This article describes preliminary experiences with PROPELLER MRI. PROPELLER uses a radial scan variation of the fast spin-echo sequence and it shows much less spatial deterioration than the echo-planar imaging sequence. To determine the optimal parameters of this technique, we calculated the signal intensities of phantoms and brains in various settings. PROPELLER MR examinations were also performed in 66 patients for clinical use. PROPELLER MRI appears to be a promising and useful technique.

Artifacts↗

Diffusion-weighted echo planar imaging of ovarian tumors: is it useful to measure apparent diffusion coefficients?

PURPOSE: Our goal was to test the hypothesis, as previously reported in other studies, that apparent diffusion coefficients (ADCs) provide specific information to diagnose ovarian tumors, especially to discriminate between benign and malignant lesions. METHOD: T1-and T2-weighted spin echo imaging and diffusion-weighted echo planar imaging were performed in 31 women with 61 cystic components of ovarian tumors. RESULTS: The lesions that showed typical watery intensity, hypointensity in T1-weighted imaging, and hyperintensity in T2-weighted imaging had similar ADCs, ranging from 1.54 to 1.84 x 10(-3) mm2 /s. The lesions that showed signal intensity different from typical watery intensity in conventional MRI tended to have low ADCs. In endometrial cysts, the mean ADC of the subgroup that showed typical watery intensity was higher than that of other subgroups. CONCLUSION: With conventional MRI, a tendency of ADCs could be predicted. ADCs may not provide additional information, especially to discriminate benign from malignant lesions.

Adult↗

Two-dimensional magnetic resonance digital subtraction angiography using array spatial sensitivity encoding techniques in the assessment of intracranial hemodynamics.

OBJECTIVE: Array spatial sensitivity encoding techniques (ASSET) were employed to improve the temporal resolution of two-dimensional (2D) thick-slice contrast-enhanced magnetic resonance digital subtraction angiography (MRDSA). METHODS: 2D MRDSA using ASSET was performed in 28 patients via fast spoiled gradient-echo sequence (TR/TE 5.4/1.5 ms; FA 60; FOV 24x24 cm; matrix size 256x256; slicethickness 50-70 mm), followed by a bolus injection of gadolinium chelate and subsequent saline flush, for 40 seconds on a sagittal plane. Images were evaluated for visualization of normal intracranial vessels and brain lesions utilizing a three-point scale; additionally, in 10 of the 28 patients, results were compared with those of conventional 2D MRDSA. RESULTS: 2D MRDSA using ASSET, which improved temporal resolution from 1.45 to 0.77 seconds, displayed image quality comparable to that of conventional 2D MRDSA. Moreover, this technique afforded superior detectability with respect to early venous filling in patients with arteriovenous malformations (AVMs). CONCLUSION: ASSET improves the temporal resolution of 2D MRDSA without compromising spatial resolution.

Brain Neoplasms↗