Search PubMed⌕ Search

Biomedical subjects

Hiroshi Kozuka

Publications and source records attributed to Hiroshi Kozuka.

3 recordsLinked to original sources

Evaluation of aroma compounds contributing to muskmelon flavor in Porapak Q extracts by aroma extract dilution analysis.

The flavor of the Miyabi variety of Japanese muskmelon was extracted according to the Porapak Q column method (PQM) and evaluated by using aroma extract dilution analysis (AEDA) method. The overall odor of the PQM extracts was perceived as having a natural muskmelon-like odor, suggesting that the PQM was able to extract volatile compounds in muskmelon fruit without degradation of original flavor. Forty-six odorant compounds [Kovats index (KI), 961 < or = KI < or = 2605] were found by GC-sniffing in PQM extracts, confirming the effectiveness of PQM in trapping a wide range of volatile compounds in muskmelon flavor. The 46 odorants could be divided into three groups on the basis of their odor attributes: fruity note (KI < 1300); green, grassy, or cucumber-like note (1300 < KI < 2020); and sweet note (KI > 2020). When the original extracts were diluted in AEDA analysis, seven odorants could still be detected by GC-sniffing at a flavor diluation (FD) factor of 128 or above: one had a fruity note (compound 3); four had a cucumber-like, green, or grassy note (compounds 12, 17, 21, and 23); and two had a sweet note (caramel-like or yakitori-like) (compounds 32 and 34).

Chromatography, Gas↗

Application of the porapak q column extraction method for tomato flavor volatile analysis.

The Porapak Q column method (PQM) was compared to the method of simultaneous distillation extraction (SDE) under reduced pressure for extraction of the volatile compounds produced by tomato cv. Momotaro. The PQM was found to be effective at trapping and isolating many low and high boiling point volatile compounds and at producing the very desirable natural ripe tomato flavor of extracts. The SDE method was less effective in isolating the higher boiling point volatile compounds and caused deterioration of volatile compounds due to the heating process that takes place during extraction, resulting in an unpleasant boiled green tomato flavor of extracts. The advantages of using the PQM are its simplicity and its high efficiency in isolating many volatile compounds from nonvolatile materials at room temperature. A total of 367 volatile compounds were isolated by the PQM. Of these, hexanal, (Z)-3-hexenal, (E)-2-hexenal, 2- and 3-methylbutanol, and 2-phenylethanol were relatively more abundant than other compounds and (Z)-3-hexenal showed the highest relative amount.

Chromatography, Gas↗