Search PubMed⌕ Search

Biomedical subjects

Hirokuni Arai

Publications and source records attributed to Hirokuni Arai.

18 recordsLinked to original sources

Cytosolic phospholipase A2 inhibition attenuates ischemia-reperfusion injury in an isolated rat lung model.

BACKGROUND: Arachidonic acid metabolites and platelet-activating factor (PAF) are potentially involved in ischemia-reperfusion (IR) lung injury. A key enzyme regulating their metabolism is cytosolic phospholipase A2 (cPLA2). Arachidonyl trifluoromethyl ketone (AACOCF3) is reported to be a potent cPLA2 inhibitor. In the present study, we hypothesized that pharmacological inhibition of cPLA2 might ameliorate IR lung injury. METHODS: To test the hypothesis, we examined the effects of AACOCF3 in an isolated rat lung model. Three groups were defined (n=6, each): in the vehicle group, lungs were perfused for 2 hours without an ischemic period. In the ischemic groups, 20 mg/kg of AACOCF3 (AACOCF3 group) or saline (control group) was i.v. administered 15 min before lung harvest. Lungs were flushed with LPD solution, cold-stored 18 hours, and reperfused for 2 hours. RESULTS: IR increased cPLA2 activity mainly via alveolar macrophages, sPLA2 activity, thromboxane and leukotriene formation, and the expression of PAF receptor, whereas AACOCF3 treatment significantly reduced all of these. Compared to the vehicle group, the wet-to-dry ratio, proteins in BAL, and MPO activity increased significantly by twofold, fourfold, and threefold, respectively. Furthermore, the PO2 dropped from 615.7+/-31.2 to 452.1+/-30.9 mmHg at the end of reperfusion (P<0.001). AACOCF3 treatment maintained the PO2 at a level similar to the vehicle group throughout reperfusion and reduced significantly the alveolar-capillary leakage, edema formation, and neutrophil extravasation. CONCLUSION: Pharmacological inhibition of the cPLA2 cascade decreases bioactive lipid formation and attenuates IR-induced lung injury.

Animals↗

Physiological comparison of off-pump and on-pump coronary artery bypass grafting in patients on chronic hemodialysis.

OBJECTIVES: Despite the long-term benefit, the operative results of conventional coronary artery bypass grafting for chronic hemodialysis patients remain unsatisfactory. The efficacy of off-pump coronary artery bypass grafting for hemodialysis patients is yet to be determined. The purpose of this study was to investigate the postoperative physiology of off-pump coronary artery bypass grafting for hemodialysis patients. METHODS: Twenty-five hemodialysis cases who underwent isolated coronary artery bypass grafting were reviewed. Fifteen of these patients underwent off-pump coronary artery bypass grafting (off-group) and 10 underwent on-pump coronary artery bypass grafting (on-group). Comparisons were made in cardiac function (cardiac index and stroke volume index), respiratory function (AaDO2), hemodialysis management (blood urea nitrogen, creatinine, right atrial pressure, pulmonary wedge pressure), and bleeding tendency (postoperative blood loss and blood transfusion). RESULTS: There was no operative mortality, but 3 major postoperative complications occurred (2 sternal wound infections in the off-group and 1 pneumonia in the on-group). There was no difference in cardiac index or stroke volume index. AaDO2 was significantly lower in the off-group. Plasma concentrations of blood urea nitrogen and creatinine were similar between groups. Right atrial pressure was lower and pulmonary wedge pressure tended to be lower in the off-group. Postoperative bleeding and blood transfusion were similar between groups. CONCLUSION: Our study confirmed that off-pump coronary artery bypass grafting is feasible for hemodialysis patients. Physiologic data showed that off-pump coronary artery bypass grafting might be effective in preserving postoperative lung oxygenation.

Aged↗

On-pump beating-heart mitral valve plasty without aortic cross-clamping.

Patients with ischemic cardiomyopathy often have mitral regurgitation, which should be corrected for better long-term survival. Mitral valve surgery is usually performed during cardiopulmonary bypass under the arrested heart condition. The ascending aorta is cross-clamped and the heart is arrested using a cardioplegic solution. However, because ischemic cardiomyopathy patients often have a severely atherosclerotic ascending aorta and low cardiac function, aortic cross-clamping and cardiac arrest increase the risk of postoperative thromboemboli and low cardiac output syndrome. Under the on-pump beating-heart condition, we performed mitral valve plasty concomitant with coronary artery bypass grafting, tricuspid annuloplasty, left ventricular aneurysmectomy, and the maze procedure without aortic cross-clamping for a patient with ischemic dilated cardiomyopathy and bradycardial atrial fibrillation. The patient had no postoperative complications and re covered rapidly. Thus, to prevent serious postoperative complications, on-pump beating-heart mitral valve surgery without aortic cross-clamping may be a suitable surgical option for patients with ischemic cardiomyopathy.

Aged↗

Oral cibenzoline reduces postoperative atrial fibrillation in coronary artery bypass grafting.

OBJECTIVE: The objective of the present study was to investigate the effectiveness of postoperative oral administration of cibenzoline for the prevention of atrial fibrillation (AF) in coronary artery bypass grafting (CABG). METHODS: A total of 39 patients who underwent isolated CABG from September 2000 to February 2001 and who took oral cibenzoline (300 mg per day for 10 days beginning immediately after surgery) were compared to 59 patients who underwent surgery in our department 8 months prior to the study and who did not take cibenzoline for incidence of postoperative AF. Exclusion criteria encompassed age (>80 years), low ejection fraction (<30%), high serum creatinine level (>2.0 mg/dL), and history of supraventricular arrhythmia with or without treatment by anti-arrhythmic drugs. RESULTS: Postoperative AF occurred in 2 patients in the cibenzoline group (2/35, 5.7%) and 20 patients in the control group (20/59, 33.9%). There were significant differences in the incidence of postoperative AF (p = 0.002). Multivariate analysis revealed that the administration of cibenzoline reduced the incidence of AF significantly, and that a large number of bypass grafts significantly contributed to postoperative AF in CABG. The number of bypass grafts was significantly larger in the cibenzoline group, indicating that cibenzoline administration significantly suppresses the incidence of AF after CABG in high-risk patients. CONCLUSIONS: Postoperative administration of oral cibenzoline for 10 days is one effective method for the prevention of AF after CABG.

Administration, Oral↗

Safe coronary artery occlusion with a new tourniquet in off-pump bypass grafting.

Coronary artery occlusion during off-pump coronary artery bypass grafting may lead to mechanical trauma of the arterial wall. My colleagues and I describe a safe coronary artery occlusion technique in off-pump bypass grafting that uses a new spring-equipped tourniquet, which enables precise adjustment of the least force necessary to occlude the coronary flow. This prevents snare-induced vessel wall damage.

Coronary Artery Bypass, Off-Pump↗

Effects of the postoperative administration of diltiazem on renal function after coronary artery bypass grafting.

BACKGROUND: Radial artery grafts are used for coronary artery bypass grafting (CABG), and postoperative antispasm therapy with diltiazem is performed widely. Some investigators have warned that diltiazem administration after cardiac surgery is harmful to renal function. We designed a retrospective study to investigate the renal and hemodynamic effects of the postoperative administration of diltiazem in patients undergoing CABG. METHODS: Subjects were 90 consecutive CABG patients. All were treated with diltiazem during surgery (a 0.1 mg/kg bolus injection followed by continuous infusion at 2 microg x kg(-1) x min(-1)). In the 50 patients (diltiazem group) with a radial artery graft, intravenous diltiazem administration was continued until the oral intake of diltiazem (90 mg/d) was begun to avoid graft spasms. In the remaining 40 patients without a radial artery graft, diltiazem was not continued postoperatively (control group). Postoperative renal function, assessed by serum creatinine level and creatinine clearance, and hemodynamic variables (heart rate, arterial pressure, pulmonary wedge pressure, cardiac index, left ventricular stroke work index) was compared between the two groups. RESULTS: Renal function: Serum creatinine concentrations on postoperative days 1 through 7 were lower, and the endogenous creatinine clearance in the early postoperative period was higher in diltiazem group than in control group, although the differences were not significant. Hemodynamics: Heart rate was lower in diltiazem group than in the control group, but blood pressure, pulmonary wedge pressure, cardiac index, left ventricular stroke work index, and urinary output were similar between the groups. CONCLUSIONS: Our results confirmed that intravenous diltiazem treatment in patients undergoing CABG is not harmful to renal function.

Coronary Artery Bypass↗

Aprotinin attenuated ischemia-reperfusion injury in an isolated rat lung model after 18-hours preservation.

OBJECTIVE: Ischemia-reperfusion injury is a major factor in the early phase of lung transplantation. We hypothesized that aprotinin, a nonspecific serine protease inhibitor, attenuates ischemia-reperfusion lung injury by inhibiting the inflammatory response and suppressing NADPH oxidase. METHODS: We used an isolated rat lung model to test the above. A Control group was immediately perfused with fresh heparinized allogeneic blood after lung harvest without an ischemic period. Study lungs were flushed with low-potassium dextran (LPD) solution and stored for 18h at 4 degrees C then divided into two groups: the LPD group was flushed with LPD solution only, and the LPD+A group was flushed with LPD solution +200KIU/ml aprotinin. Lungs in all three groups were then reperfused with fresh heparinized allogeneic blood for 120min at 37 degrees C. RESULTS: Throughout reperfusion, PO(2) levels in the LPD+A group were similar to those in the Control group; although in the LPD group, PO(2) levels were significantly lower (P<0.05). Tissue MDA levels were significantly higher in the LPD group than the Control and LPD+A groups (P<0.05). IL-8 levels were significantly higher in the LPD group than the Control group (P<0.05), while in the LPD+A group they were similar to those in the Control group. Histological evaluation showed interstitial edema accompanied by neutrophil extravasation in the LPD group, whereas this effect was modest in the LPD+A group. An additional study of ischemia-reperfusion in an alveolar macrophage culture showed that the activitvation of NADPH oxidase, and translocation of p47(phox) from the cytosol to the membrane were suppressed in aprotinin group. CONCLUSIONS: Aprotinin attenuates ischemia-reperfusion lung injury by inhibiting the early inflammatory response, neutrophil extravasation and the production of oxygen free radicals through inhibition of the activation of the NADPH oxidase. The inhibition of p47(phox) translocation in alveolar macrophage seemed involved in this mechanism of aprotinin.

Animals↗

Disposable magnetically levitated centrifugal blood pump: design and in vitro performance.

A magnetically levitated (MagLev) centrifugal blood pump (CBP) with a disposable pump head has been designed to realize a safe, easy-to-handle, reliable, and low-cost extracorporeal blood pump system. It consisted of a radial magnetic-coupled driver with a magnetic bearing having a two-degree freedom control and a disposable pump head unit with a priming volume of 24 mL. The easy on-off disposable pump head unit was made into a three-piece system consisting of the top and bottom housings, and the impeller-rotor assembly. The size and weight of the disposable pump unit were 75 mm x 45 mm and 100 g, respectively. Because the structure of the pump head unit is easily attachable and removable, the gap between the electromagnets of the stator and the target material in the rotor increased to 1.8 mm in comparison to the original integrated bearing system of 1.0 mm. The pump performance, power requirements, and controllability of the magnetic bearing revealed that from 1400 to 2400 rpm, the pump performance remained fairly unchanged. The amplitudes of the X- and Y-axis rotor oscillation increased to +/- 24 microm. The axial displacement of the rotor, 0.4 mm, toward the top housing was also observed at the pump rpm between 1400 and 2400. The axial and rotational stiffness of the bearing were 15.9 N/mm and 4.4 Nm/rad, respectively. The MagLev power was within 0.7 Watts. This study demonstrated the feasibility of a disposable, magnetically suspended CBP as the safe, reliable, easy-to-handle, low-cost extracorporeal circulation support device.

Centrifugation↗

Hand circulation after radial artery harvest for coronary artery bypass grafting.

Despite wide spread use of the radial artery (RA) graft for coronary artery bypass grafting, the change of hand circulation after RA harvest has not been fully clarified. Severe hand ischemia such as resting pain or gangrene is a rare complication and has been reported in 4 patients. These cases resulted from occlusive artery disease in forearm, which should be carefully explored before RA harvest. Incidence of mild hand ischemia such as hand claudication or fatigue is unknown, but our study suggested that around 10% of the patients developed mild hand ischemia after RA harvest. The blood flow to the forearm territory was decreased by 20% after RA harvest despite the compensatory dilatation of ulnar artery. The presence of low perfusion in the affected hand has been pointed out in some studies. We reported the decreased tissue oxygenation of the affected hand during hand grip exercise. The Allen test is the most popular preoperative screening method, but is associated with considerable numbers of false-positive and false-negative results. Full length scanning of ulnar artery by ultrasonography seems to have a lower false-positive rate. But further clinical experience is necessary to establish a more reliable screening method.

Coronary Artery Bypass↗

Endoscopic radial artery harvesting: our initial experience and results of the first 25 patients.

BACKGROUND: The radial artery has become an increasingly popular arterial conduit for coronary artery bypass grafting (CABG). However, the traditional open harvesting technique requires a long incision, and is therefore associated with some wound complications and cosmetic problems. Here, we describe our experience of endoscopic radial artery harvesting (ERAH) through a small incision in 25 patients who underwent CABG. MATERIALS AND METHODS: Between February 2, 2004 and January 7, 2005, a total of 25 patients (4 females; mean age: 64+/-10 years) underwent ERAH using the VasoView System (Guidant Corporation, Indianapolis, IN) at our institution. All patients underwent a preoperative Allen test to assess the competence of the palmer arch. Twenty-four radial arteries were harvested from the nondominant arm and one from the dominant arm. The mean clinical follow-up was 8+/-2.9 months. RESULTS: All radial arteries were harvested through a 2-cm incision at the wrist, successfully removed with ERAH and successfully used as CABG conduits. The mean harvest time was 59+/-11 min, and the mean harvested length was 17+/-1.7 cm. No adjunctive procedures were required during vessel harvesting, and no conversions to the open technique were necessary. Harvesting complications included 2 cases of postoperative hematoma and 7 cases of superficial radial nerve paresthesia. Five postoperative angiographies were performed and all radial arteries were patent. Overall, 24/25 (96%) patients were satisfied with the procedure. CONCLUSION: The ERAH technique was performed as safely as the traditional open technique and the harvested radial arteries were acceptable as CABG conduits. In particular, patient satisfaction with the procedure regarding the cosmetic results was excellent.

Coronary Artery Bypass↗

Perfusion flow assessment of coronary shunt during off-pump coronary artery bypass grafting.

BACKGROUND: Coronary shunts are widely used to prevent myocardial ischemia during off-pump coronary artery bypass graft (OPCAB) procedures. Although clinical effectiveness has been reported, actual perfusion flow has not been well assessed. The purpose of this study was to evaluate actual shunt flow and its pattern during passive coronary perfusion in clinical OPCAB. METHODS: In 15 OPCAB cases, the coronary perfusion flow of the external shunt (1.7 or 2.0 mm) during anastomosis and the free flow of the shunt were measured with an in-line electromagnetic or ultrasonic flow probe. The perfused coronary blood vessel was either the left anterior descending coronary artery or the right coronary artery. The inflow vessel of the external shunt was either the femoral artery (FA) or the ascending aorta (AA). RESULTS: Free flow values of a 1.7-mm FA shunt, 1.7-mm AA shunt, and 2.0-mm FA shunt were 34+/- 7, 39 +/- 3, and 44 +/- 7 mL/min. Perfusion flows were 13 +/- 4, 14 +/- 3, and 22 +/- 4 mL/min, respectively. Perfusion flow was significantly lower than free flow and correlated well with coronary resistance. Although inflow site did not influence net perfusion flow, diastolic/systolic flow fraction ratio was significantly greater when the shunt was perfused from the FA. CONCLUSIONS: External shunt from FA would provide limited but effective perfusion flow with a physiological pattern, which is passively regulated by coronary resistance.

Aged↗

Double-patch technique for postinfarction ventricular septal perforation.

A modified infarct-exclusion technique for postinfarction ventricular septal perforation is presented. The perforation is closed directly by a small patch next to the conventional patch, and biological glue is applied between the patches to induce stable polymerization. The patch stuck to the infarcted septum, and no residual shunt was observed in any patient because the wide adhesion prevents excessive pressure on the suture line. Seven of 9 patients in whom this method was used had good results. This technique appears suited for repair of ventricular septal perforations, especially those with extensive fresh infarction.

Cardiac Surgical Procedures↗

Biventricular pacing with coronary bypass and Dor's ventriculoplasty.

We applied biventricular pacing to a patient with severe ischemic dilated cardiomyopathy (left ventricular [LV] ejection fraction 19%, LV end-diastolic volume 360 mL, and complete left bundle branch block). An epicardial LV lead was surgically implanted concomitant with on-pump beating coronary artery bypass grafting and Dor's endoventricular circular patch plasty. Biventricular pacing immediately achieved the resynchronization of the LV contraction, and improved cardiac function as well as reducing mitral regurgitation. Biventricular pacing combined with cardiac surgery for patients with cardiomyopathy and complete left bundle branch block may produce beneficial effects on LV function.

Aged↗

Temporary and permanent biventricular pacing via left ventricular epicardial leads implanted during primary cardiac surgery.

OBJECTIVES: Biventricular pacing (BVP) is a new strategy for treating patients with severe congestive heart failure (CHF) and intraventricular conduction delay, but its full potential and technicalities of BVP require further evaluation. We evaluated BVP benefits in 4 patients in whom we implanted a left ventricular lead during primary cardiac surgery. METHODS: Four CHF patients treated surgically between October 2000 and August 2001 underwent, at primary surgery, the implantation of leads in the right atrium, right ventricle, and left ventricle (LV) for postsurgical BVP. All patients had severe LV dysfunction and dilatation with intraventricular conduction delay. Surgeries involved CABG alone (n = 1), CABG + Dor's operation (n = 2), and tricuspid valve replacement + Maze procedure (n = 1). BVP was begun immediately after surgery in all 4 patients. Hemodynamic variables with BVP were compared to those without BVP for each patient, and the utility and technical aspects of implantation were evaluated. RESULTS: BVP increased mean systemic blood pressure by 11% and mean LV stroke work index by 19% in the acute postsurgery period, and reduced mitral regurgitation. Two of the patients were implanted with a generator for permanent BVP, one at 1 month and the other at 6 months after surgery. The threshold of the LV epicardial lead of these 2 patients was below 2 V during follow-up, and BVP was successful. CONCLUSIONS: Temporary BVP during the short-term after cardiac surgery improved cardiac function and decreased mitral regurgitation in all 4 of our patients. Epicardial lead implantation may thus be a useful option during surgical treatment of patients with CHF and intraventricular conduction delay if long-term permanent BVP is indicated.

Aged↗

Biventricular pacing in a patient with severe congestive heart failure.

We report a case of dilated cardiomyopathy with severe congestive heart failure (ejection fraction: 19%) and complete left bundle branch block (QRS duration: 240 ms) 13 years after aortic valve replacement. Permanent biventricular pacing was implanted by inserting a left ventricular lead thorough a small left thoracotomy following intravenous insertion of right atrial and ventricular endocardial leads. Biventricular pacing increased hemodynamic parameters such as blood pressure, cardiac output and decreased mitral regurgitation. Symptoms and exercise tolerance improved dramatically. Left ventricular epicardial lead insertion via a small thoracotomy is thus useful in selected patients.

Aortic Valve↗

Lipopolysaccharide pretreatment attenuates myocardial infarct size: A possible mechanism involving heat shock protein 70-inhibitory kappaBalpha complex and attenuation of nuclear factor kappaB.

OBJECTIVE: Lipopolysaccharide pretreatment is known to reduce myocardial infarct size, but the mechanism has not been elucidated. We hypothesized that heat shock protein 70, induced by lipopolysaccharide pretreatment, formed complexes with inhibitory kappaBalpha, thereby inhibiting degradation and attenuating activation of nuclear factor kappaB and cellular injury in rat myocardium. METHODS: Fifteen Sprague-Dawley rats were given saline solution (control group) or lipopolysaccharide. After 48 hours, 5 hearts in each group were excised without ischemia for examination of heat shock protein 70 and inhibitory kappaBalpha levels and detection of heat shock protein 70-inhibitory kappaBalpha complexes. Myocardium from the remaining 10 rats in each group was exposed to 30 minutes of ischemia and 30 minutes of reperfusion (n = 5) to evaluate nuclear factor kappaB activity or to 24 hours of reperfusion (n = 5) to evaluate infarct size. RESULTS: Infarct size was reduced in the lipopolysaccharide group (P <.05). Nuclear factor kappaB was activated in the control ischemia group and attenuated in the lipopolysaccharide group (P <.05). Heat shock protein 70 levels were increased in the lipopolysaccharide group (P <.05), but inhibitory kappaBalpha levels were similar in both groups. Heat shock protein 70-inhibitory kappaBalpha complexes were detected only in the lipopolysaccharide group. Colocalization of the 2 proteins was observed in the lipopolysaccharide group. CONCLUSIONS: Heat shock protein 70, induced by lipopolysaccharide pretreatment, forms complexes with inhibitory kappaBalpha and attenuates activation of nuclear factor kappaB and myocardial infarct size. Our results suggest that attenuation of nuclear factor kappaB through a mechanism forming heat shock protein 70-inhibitory kappaBalpha complexes might protect the myocardium from ischemia-reperfusion injury.

Animals↗

One piece ultracompact totally implantable electromechanical total artificial heart for permanent use.

An ultracompact, one piece, totally implantable electromechanical total artificial heart (TAH) has been developed as a permanent replacement for failing hearts. It consists of left and right pusher plate blood pumps (stroke volume 55 ml) made of titanium alloy (Ti-6Al-7Nb) sandwiching a miniaturized electromechanical actuator between them. The diameter of the TAH is 90 mm, with a thickness of 70 mm, yielding an overall volume of 400 ml. It weighs 450 g. Although it is miniaturized, it provided a maximum pump output of 8 L/min against a left afterload of 100 mm Hg. It required approximately 12 watts to provide a pump output of 6.5 L/min with maximum efficiency of 13.5%. To balance left and right flow, the right stroke length was made 10% shorter than the left, and an auxiliary compliance chamber was used to compensate for additional flow differences between them. Motor commutation pulses and a Hall effect pusher plate sensor signal were used in the controller to implement the left master alternate variable rate mode. The calf fitting study revealed excellent anatomic compatibility, and the first successful survivor was obtained in December 2001. Studies of system endurance and biocompatibility are required to ensure long-term reliability. This TAH is promising for permanent replacement of the failing heart as well as for bridge to heart transplantation for the smaller size group of end-stage cardiac patients.

Animals↗