Search PubMed⌕ Search

Biomedical subjects

Hilmar Kuehl

Publications and source records attributed to Hilmar Kuehl.

23 records · Page 2Linked to original sources

Interventional MR angiography with a floating table.

A floating table was integrated into a setup for performance of interventional magnetic resonance (MR) angiography procedures with actively visualized catheters and biplanar real-time image fusion. The setup was evaluated by performing catheterizations in eight pigs. The floating table enabled the authors to follow actively visualized instruments in the pigs' vasculature during MR imaging-guided interventional angiography procedures while performing real-time biplanar MR imaging. Interventional MR angiography with a floating table enables the field of view to be moved along with the instrument tip to the region of interest and thus enhances the usability and flexibility of the interventional MR imaging setup.

Animals↗

Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion.

An integrated system for performing interventional magnetic resonance angiography (MRA) with actively visualized instruments and real-time image fusion was implemented on a 1.5 T scanner. True fast imaging with steady precession (TrueFISP) imaging provided high acquisition speed paired with high signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the simultaneous visualization of active instruments and arterial morphology. The system enabled simultaneous image reconstruction and image postprocessing of multiple receiver channels, with subsequent image fusion display in real time. Optional interleaved image acquisition in two planes provided additional important information for biplanar instrument guidance. Various vascular interventions, including selective catheterization and subsequent selective MRA of the abdominal aorta, renal arteries, superior mesenteric artery (SMA), hepatic artery, and aortic arch, were performed on 10 pigs under MR guidance. In terms of instrument contrast, image acquisition, reconstruction, and fusion speed, the setup represents a powerful platform for performing interventional MRA procedures.

Animals↗

Inductively coupled stent antennas in MRI.

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis.

Animals↗

Value of CT volume imaging for optimal placement of radiofrequency ablation probes in liver lesions.

PURPOSE: To determine the value of multiplanar and volume-rendered modes of analysis versus axial imaging for the optimal placement of probes in spiral image computed tomography (CT)-guided radiofrequency (RF) ablation of liver lesions. MATERIALS AND METHODS: Thirty-two malignant hepatic lesions in 21 patients with hepatocellular carcinoma (n = 10) or metastases (n = 11) were treated with percutaneous RF ablation. After axial CT-guided placement (biopsy mode) of the probe in the tumor, a contrast-enhanced spiral image set was obtained and data were viewed in contiguous axial sections and the multiplanar and volume-rendered modes. The position of the probe was characterized as "central," "marginal," or "outside," corresponding with its position in the lesion. Outside positioning was corrected before ablation was performed and, in cases of "marginal" positioning, the probe was redirected after initial ablative therapy in the same session. RESULTS: Multiplanar and volume-rendered analysis reclassified the needle position before 14 of 32 RF ablation procedures (44%; P =.0034, McNemar test). In 10 cases, probe positions considered "central" on biopsy-mode images were found to be "marginal" with multiplanar/volume-rendered analysis. In three cases, probe positions considered "marginal" on biopsy-mode images were found to be "outside" with multiplanar/volume-rendered analysis. In one lesion, multiplanar/volume-rendered analysis upgraded the probe position from "marginal" to "central." Comparison of multiplanar and volume-rendered analysis revealed no difference in probe positioning. The time requirements to obtain additional data were 159 seconds +/- 49 for multiplanar analysis and 434 seconds +/- 78 for volume-rendered analysis. CONCLUSION: A contrast-enhanced spiral CT image data set with multiplanar reformations to verify an optimal probe location after axial CT-guided needle placement should be obtained before RF ablation of liver lesions.

Aged↗

Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience.

A technique for performing whole-body magnetic resonance (MR) angiography with multi-station three-dimensional MR angiography by using a self-developed rolling table platform that integrates the surface coil was evaluated in three volunteers and 10 patients. Use of the surface coil resulted in high signal-to-noise and contrast-to-noise ratios, which translated into sensitivity and specificity of 95.3% and 95.2%, respectively, for detection of significant stenoses (luminal narrowing, >50%) in lower extremity peripheral vascular disease.

Adult↗