Search PubMed⌕ Search

Biomedical subjects

Hidenobu Nakajo

Publications and source records attributed to Hidenobu Nakajo.

13 recordsLinked to original sources

Clinical applications of ECG-gated myocardial perfusion SPECT.

Erectrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) can be used to assess myocardial perfusion and left ventricular function simultaneously. Various clinical applications of gated SPECT and their usefulness have been reported. The functional variables that can be determined with gated SPECT have been limited to systolic indices. Therefore, we evaluated left ventricular diastolic function with gated SPECT using data obtained from various frames per cardiac cycle and found that date generated from 32-frames are suitable for clinical use. Serial assessment of left ventricular function was also performed during bicycle exercise and dobutamine stress by means of gated SPECT using short-time data collection. These techniques, therefore, have the potential to provide useful information for evaluating myocardial conditions, such as hibernation and residual ischemia in infarct areas. Recently, we have developed a new technique for three-dimensional registration of CT coronary angiography (CTCA) and ECG-gated myocardial perfusion SPECT. This technique of registration may assist the integration of information from gated SPECT and CTCA and may have clinical application for the diagnosis of ischemic heart disease. These various applications would contribute to the development of nuclear cardiology.

Coronary Angiography↗

Two cases of subacute combined degeneration: magnetic resonance findings.

We report two cases of subacute combined degeneration. Both patients had undergone total gastrectomy. The chief complaints were numbness in both upper extremities in case 1 and numbness in both the upper and lower extremities and gait disturbance in case 2. The pain, temperature, and vibration senses of both patients were decreased. Laboratory examinations showed macrocytic anemia and a decreased serum vitamin B12 level in both cases. In both cases T2-weighted magnetic resonance images showed an area of hyperintensity in the dorsal columns of the cervical spinal cord. The patients were treated with vitamin B12. The abnormal signals had disappeared on follow-up magnetic resonance examination 1 year later in case 1 and 3 months later in case 2. These patients showed neurological improvement, but the numbness in the upper extremities persisted even after the area of abnormal signal intensity had disappeared in case 1.

Aged↗

Dual-isotope myocardial SPECT in patients with redefined myocardial infarction.

BACKGROUND: According to the redefinition of myocardial infarction (MI) by the ESC/ACC Committee, patients with unstable angina (UA) without significant elevation of creatine kinase (CK) but with elevation of troponin T should be diagnosed as MI. METHODS: One hundred and forty-six consecutive patients formerly diagnosed as UA, with peak CK levels 0.10 ng/ml). Dual SPECT findings were analyzed qualitatively and quantitatively in blinded manner. RESULTS: Forty-seven patients (32%) were redefined as MI and 99 patients (68%) were redefined as UA. On admission, there were small but statistically significant elevations in laboratory parameters such as white blood cell count, C-reactive protein, CK and CK-MB in the redefined MI group compared with the redefined UA group. The proportion of patients with perfusion and metabolic abnormalities was significantly higher in the redefined MI group (Tl defect 36% vs. 4%, odds ratio: 13.5, p<0.001; BMIPP defect 64% vs. 23%, odds ratio: 5.8, p<0.001). Semi-quantitative evaluation revealed that the total Tl and BMIPP scores were significantly higher in the redefined MI patients (p<0.001). CONCLUSIONS: In the redefined MI patients, perfusion and metabolic abnormalities occurred frequently and more extensively. However, Tl/BMIPP dual SPECT had limited ability to detect minor myocardial infarcts classified as redefined MI. A more sensitive stratification combined with troponin T directed assignment should be established to incorporate the ongoing minor infarcts which could not be assessed by serial dual-scintigraphic evaluations.

Aged↗

Three-dimensional registration of myocardial perfusion SPECT and CT coronary angiography.

OBJECTIVE: In this study, we describe a new technique for three-dimensional registration of CT coronary angiography (CTCA) and gated myocardial perfusion SPECT. METHODS: Twelve patients with known or suspected CAD who underwent CTCA and gated SPECT were enrolled retrospectively. Coronary arteries and their branches were traced using CTCA data manually and reconstructed in three-dimensions. Gated SPECT data were registered and mapped to a left ventricle binary model extracted from CTCA data using manual, rigid and nonrigid registration methods. RESULTS: Three-dimensional reconstruction and volume visualization of both modalities were successfully achieved for all patients. All 3 registration methods gave better quality based on visual inspection, and nonrigid registration gave significantly better results than the other registration methods (p < 0.05). The cost function for three-dimensional registration using nonrigid registration (235.3 +/- 13.9) was significantly better than those of manual and rigid registration (218.5 +/- 15.3 and 223.7 +/- 17.0, respectively). Inter-observer reproducibility error was within acceptable limits for all methods, and there were no significant difference among the methods. CONCLUSION: This technique of image registration may assist the integration of information from gated SPECT and CTCA, and may have clinical application for the diagnosis of ischemic heart disease.

Aged↗

Assessment of contractile response to dobutamine stress by means of ECG-gated myocardial SPECT: comparison with myocardial perfusion and fatty acid metabolism.

UNLABELLED: The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. CONCLUSIONS: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.

Coronary Vessels↗

A case of dermoid cyst of the ovary with malignant transformation complicated with small intestinal fistula formation.

A 54-year-old woman complained of abdominal pain and watery diarrhea that had begun two days before admission. Physical examination revealed abdominal distention and tenderness throughout the abdomen, but there was no muscle guarding or rebound tenderness. The leukocyte count was 27.0 x 10(3)/microl, and CRP was 28.5 mg/dl. A plain film of the abdomen revealed the shadow of a huge gas-containing mass with an air-fluid level and a dilated small intestine with air-fluid level. CT showed a huge gas-containing cystic mass with fatty component and solid structure. Omental thickening was also noted. Emergency surgery was performed, and an enlarged left ovary that was adherent to the small intestine was removed. Microscopic examination revealed a squamous cell carcinoma in the dermoid cyst wall. The carcinoma had directly invaded the small intestine and a fistula between the cyst and the intestine was noted. Thickened omentum showed granulomatous inflammation in the fatty tissue, but no metastases were detected. The histopathological diagnosis was dermoid cyst with malignant transformation and invasion of the small intestine. Chemotherapy was performed, but the patient died of progression of peritoneal metastases 10 months after the operation.

Carcinoma, Squamous Cell↗

Three-dimensional display in staging hemodynamic brain ischemia for JET study: objective evaluation using SEE analysis and 3D-SSP display.

The Japanese EC-IC bypass trial (JET study) was established to evaluate the validity of MCA-STA anastomosis in intracranial arterial occlusive disease aiming at stroke prevention. This study must use an objective method to reliably estimate hemodynamic brain ischemia. We devised a method of objectively classifying the severity of hemodynamic ischemia using quantitatively analytical and display software, stereotactic extraction estimation for stereotactic brain coordinates and three-dimensional stereotactic surface projections (3D-SSP). We analyzed data from 16 patients registered in the JET study. Our method offers quantitative information and 3-dimensional displays of the CBF at rest and after Diamox challenge, vascular reserve and the severity of the hemodynamic brain ischemia. We compared the maximal projection counts with ROI data from tomographic images in the anterior commissure-posterior commissure plane. The maximal counts data correlated closely with the ROI data of rest and with Diamox SPECT images (both p < 0.0001). The slopes of the linear regression line were 1.15 and 1.12, respectively. The results of this study indicated that our method could simply and objectively evaluate the severity of impaired brain circulation. This procedure should support the evaluation of hemodynamic ischemia in the JET study although validation is required by several institutions using more study subjects.

Aged↗

Development of quantitative analysis method for stereotactic brain image: assessment of reduced accumulation in extent and severity using anatomical segmentation.

Through visual assessment by three-dimensional (3D) brain image analysis methods using stereotactic brain coordinates system, such as three-dimensional stereotactic surface projections and statistical parametric mapping, it is difficult to quantitatively assess anatomical information and the range of extent of an abnormal region. In this study, we devised a method to quantitatively assess local abnormal findings by segmenting a brain map according to anatomical structure. Through quantitative local abnormality assessment using this method, we studied the characteristics of distribution of reduced blood flow in cases with dementia of the Alzheimer type (DAT). Using twenty-five cases with DAT (mean age, 68.9 years old), all of whom were diagnosed as probable Alzheimer's disease based on NINCDS-ADRDA, we collected I-123 iodoamphetamine SPECT data. A 3D brain map using the 3D-SSP program was compared with the data of 20 cases in the control group, who age-matched the subject cases. To study local abnormalities on the 3D images, we divided the whole brain into 24 segments based on anatomical classification. We assessed the extent of an abnormal region in each segment (rate of the coordinates with a Z-value that exceeds the threshold value, in all coordinates within a segment), and severity (average Z-value of the coordinates with a Z-value that exceeds the threshold value). This method clarified orientation and expansion of reduced accumulation, through classifying stereotactic brain coordinates according to the anatomical structure. This method was considered useful for quantitatively grasping distribution abnormalities in the brain and changes in abnormality distribution.

Aged↗

Assessment of left ventricular function using solid-state gamma camera equipped with a highly-sensitive collimator.

PURPOSE: The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS: ERNV was performed from the best septal position (left anterior oblique view) in 20 patients with cardiac disease using a single detector anger-type gamma camera equipped with a low-energy, high-resolution collimator. Immediately thereafter, we performed a second ERNV using the solid-state gamma camera equipped with a highly sensitive collimator. Acquisition periods were 10 and 3 min, respectively. RESULTS: Significantly more counts were collected from over the left ventricle with the solid-state gamma camera over 3 min than those with the anger-type gamma camera over 10 min (817.1 +/- 387.8 k counts vs. 668.2 +/- 327.4 k counts, p < 0.01). The left ventricular ejection fraction obtained from ERNV data using the solid-state gamma camera correlated closely with those acquired by the anger-type gamma camera (r = 0.94, p < 0.0001, SEE = 5.93%). CONCLUSION: The results showed that the solid-state gamma camera could assess left ventricular function with excellent data collection efficiency and high reliability.

Equipment Failure Analysis↗

Serial assessment of left ventricular performance at rest and during bicycle exercise by ECG-gated myocardial perfusion SPECT.

UNLABELLED: The present study evaluates left ventricular performance during exercise by ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS: The study population consisted of 10 healthy volunteers (Group N) and 9 patients with ischemic heart disease (Group I). Seven patients in Group I had a history of prior myocardial infarction. Rest ECG-gated SPECT was performed 40 min after an injection of Tc-99m-tetrofosmin (555-740 MBq). After resting data acquisition, Group N underwent up to two 5-min stages of exercise (75 and 125 watts) on a detachable bicycle ergometer. The Group I patients all underwent symptom-limited, maximal testing on the ergometer. ECG-gated SPECT data were acquired from both groups for 3 min at rest and during the last 3 min of each exercise stage. RESULTS: Significant increases occurred in LVEF from rest to peak stress in both groups (from 55.4 +/- 5.8 to 66.6 +/- 4.1% in group N, p < 0.0001; from 49.0 +/- 12.8 to 56.7 +/- 13.8% in Group I, p < 0.001). The LVESV values significantly decreased to peak stress in Group N (from 49.9 +/- 13.1 to 37.8 +/- 10.0 ml, p < 0.0001), whereas LVEDV did not change (from 110.6 +/- 18.9 to 112.0 +/- 19.0 ml). In contrast, the LVESV values at rest and under peak stress were similar in Group I (from 52.6 +/- 23.9 to 51.7 +/- 31.4 ml) and LVEDV in Group I at peak exercise tended to increase (from 102.8 +/- 36.7 to 111.3 +/- 39.0 ml). The changes in LVESV from rest to peak stress were significantly different between Groups N and I (-12.1 +/- 6.3 vs. -0.9 +/- 11.6 ml, p < 0.02). CONCLUSION: ECG-gated SPECT with short-time data collection can assess left ventricular function during exercise and may offer useful information for evaluating patients with ischemic heart disease.

Adult↗

Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure: comparison with normal control.

BACKGROUND: In contrast to 201TlCl, 99mTc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of 99mTc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. METHODS AND RESULTS: After administration of 99mTc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec(-1)), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6+/-5.2%) were significantly higher than those in the NC group (31.2+/-5.5%, p < 0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r = -0.61, p < 0.001), PFR (r = -0.47, p < 0.01), LVEDV (r = 0.45, p < 0.01) and LVESV (r = 0.48, p < 0.01). CONCLUSION: The myocardial washout rate of 99Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure.

Adult↗

[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].

UNLABELLED: Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS: Thirty-five patients with cardiac disease were enrolled. Following intravenous bolus injection of 740 MBq of 99mTc human serum albumin-DTPA, first-pass radionuclide angiography (FP) and 25-gated interval planar multi-gated blood pool scintigraphy (PMUGA) were performed for the measurement of right ventricular ejection fraction (RVEF; %) and left ventricular ejection fraction (LVEF; %), respectively. Subsequently TMUGA data set was acquired with a dual-head gamma camera (16 gated intervals). Then, alternative LVEF and RVEF were measured using TMUGA with QBS. Regional left ventricular wall motion for both PMUGA and TMUGA were assessed with a 4-point scoring system respectively. RESULTS: Automatic biventricular border detection using QBS was feasible in 27 of 35 patients (70.7%). Measurements of TMUGA LVEF and RVEF were well reproducible, with interobserver correlation coefficient of 0.98 and 0.97, respectively. TMUGA LVEF showed excellent correlation with PMUGA LVEF (r = 0.98, SEE = 3.92%). The agreement of LV wall motion score between TMUGA and PMUGA was 88.1% (214 of 243 segments), with a kappa value of 0.82. On the other hand, RVEF determined by QBS had a 12.4% average overestimate compared to the same value obtained by FP. Moreover 95% confidential interval of TMUGA RVEF (-28.8 to +4.0%) was wider than that of TMUGA LVEF (-10.7 to +10.7%). CONCLUSION: TMUGA with QBS analysis provided accurate and reproducible data for global and regional left ventricular function. However, the results of RVEF with TMUGA were not satisfying as a replacement for those with FP and modifying the algorithm were needed to improve accuracy of quantification.

Adult↗

[Cardiac pool scintigraphy using the solid-state Digirad 2020tc Imager--comparison with the conventional anger-type gamma camera using moving cardiac phantom].

UNLABELLED: Movable gamma camera, 2020tc Imager, was light miniaturized using Si photodiode as a semiconductor sensor instead of photomultiplier tubes. To validate performance of this new camera in cardiac pool scintigraphy, multigated equilibrium radionuclide ventriculography using the moving cardiac phantom was performed with 2020tc Imager and a conventional Agner-type gamma camera (PRISM 3000). METHOD: Both measured cardiac functional values were compared with the set-up ones for the phantom. Five-, 7.5-, and 10-minute-multigated data were acquired using both cameras under constant contractile condition. Constant 5-minute-multigated data acquisitions using 2020tc Imager were also carried out with varied contractile conditions. RESULTS: Measured ejection fraction (EF) derived from 2020tc Imager and an Anger-type camera were 68.5 +/- 0.6 and 70.3 +/- 1.4%, respectively. Both of these values were absolutely close to the set-up EF value of 70%. Both of end-diastolic volume and EF showed excellent correlation between set-up and measured values with the correlation coefficient of 0.97 and 0.99, respectively. CONCLUSION: This new movable camera could provide comparative cardiac functional values with an Anger-type camera and it can be useful to evaluate acute cardiac function in a coronary care unit.

Gamma Cameras↗