Search PubMed⌕ Search

Biomedical subjects

Hideki Yoshikawa

Publications and source records attributed to Hideki Yoshikawa.

At least 91 records · Page 5Linked to original sources

The role of bone morphogenetic proteins in endochondral bone formation.

Bone morphogenetic proteins (BMPs) were originally identified as proteins capable of inducing endochondral bone formation when implanted at extraskeletal sites. BMPs have diverse biological activities during early embryogenesis and various aspects of organogenesis. BMPs bind to BMP receptors on the cell surface, and these signals are transduced intracellularly by Smad proteins. BMP signal pathways can be inhibited by both extra- and intracellular mechanisms. As for skeletal development, genetic studies suggest that BMPs are skeletal mesoderm inducers. Recent studies of tissue-specific activation and inactivation of BMP signals have revealed that BMP signals control proliferation and differentiation of chondrocytes, differentiation of osteoblasts and bone quality. These findings may contribute not only to understanding of bone biology and pathology, but also to improvement of the clinical efficacy of BMPs.

Animals↗

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.

The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

Arthroplasty, Replacement, Knee↗

Gait analysis system for assessment of dynamic loading axis of the knee.

The purpose of this study was (1) to demonstrate a computer-assisted gait analysis system that can visualize the locus of the dynamic loading axis on the proximal tibia joint surface, and (2) to assess the accuracy of this system in a patient with bilateral knee osteoarthritis (OA). This system uses force plate data, CT skeletal structure data and motion capture data obtained from an infrared position sensor. The relative positions between bones and markers were used to calculate skeletal model movement based on movement of the markers. The locus of the dynamic loading axis on the knee joint was defined as the point on the proximal tibia joint surface that intersected with the loading axis of the lower limb, which passed through the centre of the femoral head and the centroid of multiple points surrounded by the distal tibia joint surface contour. To assess the accuracy of this system, open MRI was used to evaluate positions of skin markers against bones in six healthy volunteers. The locus in a patient was affected by differences between the varus knee with medial compartment OA on the non-operative side and the knee treated with high tibial osteotomy (HTO) on the opposite side. At knee flexion angles of 0 degrees, 15 degrees and 30 degrees, the mean value of measurement error for point locations on the locus was within 5.6% of joint width in the lateral direction (JWLD) on the proximal tibia joint. This system can provide clinically useful information for evaluation of the dynamic loading axis on the knee joint surface.

Aged↗

Change in the locus of dynamic loading axis on the knee joint after high tibial osteotomy.

The purpose of this study was to visualise the locus of the dynamic loading axis on the knee joint, and to evaluate changes in this locus during gait after high tibial osteotomy (HTO) in three patients who underwent HTO for medial compartment osteoarthritis (OA) of a varus knee. The bone structure of the lower limb and the relative position of skin markers were acquired from CT images. Motion capture data was acquired using spherical skin markers. Skeletal model movement during gait was calculated based on the movement of the markers. The locus of the dynamic loading axis on the knee joint was defined as the point on the proximal tibia joint surface that intersected with the loading axis of the lower limb, which passed through the centre of the femoral head and the centroid of multiple points surrounded by the distal tibia joint surface contour. This system was able to visualise the locus of the dynamic loading axis on the knee joint and not only lateral but also anterior-posterior direction movement. After HTO, the locus shifted from a medial and posterior area of the medial joint edge of the knee to a central area of the knee joint surface. This indicates that HTO shifted the dynamic loading axis. Lateral movement of the dynamic loading axis in the early stance phase of gait was reduced within a year after HTO.

Aged↗

Patterns of bone defect in scaphoid nonunion: a 3-dimensional and quantitative analysis.

PURPOSE: To clarify patterns and size of bone defect in scaphoid nonunion in order to facilitate accurate correction of scaphoid deformity. METHODS: Three-dimensional computed tomography was used to examine 24 patients with scaphoid nonunion. Configuration and size of bone defect were quantified and computed on the basis of fracture location. Cases were categorized as distal or proximal based on location of the fracture line relative to the dorsal apex of the scaphoid ridge. RESULTS: Distal scaphoid fractures displayed wedge-shaped bone defects with the base facing volarly. Proximal scaphoid fractures exhibited flat, crescent-shaped defects that presented only around the fracture site. The size of bone defects was significantly greater for distal fractures than for proximal fractures. CONCLUSIONS: Whether the fracture line passes distal or proximal to the dorsal apex of the scaphoid ridge is a crucial factor in the generation of bone defect. A large wedge-shaped bone graft from the volar side is necessary for distal nonunion whereas a small cancellous bone graft from the dorsal side may be preferable for proximal nonunion.

Adolescent↗

Patterns of carpal deformity in scaphoid nonunion: a 3-dimensional and quantitative analysis.

PURPOSE: To clarify quantitatively the 3-dimensional deformity of the carpus in scaphoid nonunion on the basis of fracture location. METHODS: Three-dimensional computed tomography was used to examine 20 patients with scaphoid nonunion. Displacements of the distal and proximal fragments of the scaphoid, lunate, triquetrum, and capitate were visualized and quantified using a 3-dimensional image-matching technology. Cases were categorized as distal fracture (16 cases) or proximal fracture (4 cases) based on the location of the fracture line relative to the dorsal apex of the scaphoid ridge where the dorsal scapholunate interosseous ligament is attached. RESULTS: The displayed distal scaphoid fractures showed that the proximal fragment of the scaphoid, lunate, and triquetrum rotated into extension and supination. The distal fragment of the scaphoid and capitate translated dorsally without notable rotation. The deformity in proximal fractures was less remarkable than that in distal fractures. Most distal scaphoid nonunions had dorsal intercalated segment instability deformity patterns, whereas a dorsal intercalated segment instability occurred in only 1 case of a proximal fracture. CONCLUSIONS: Whether the fracture line passes distal or proximal to the dorsal apex of the scaphoid determines the subsequent carpal deformity. Dorsal translation of the distal fragment might be one of the factors in the development of degenerative change at the radial styloid.

Adolescent↗

A new biotechnology for articular cartilage repair: subchondral implantation of a composite of interconnected porous hydroxyapatite, synthetic polymer (PLA-PEG), and bone morphogenetic protein-2 (rhBMP-2).

OBJECTIVE: Articular cartilage repair remains a major obstacle in tissue engineering. We recently developed a novel tool for articular cartilage repair, consisting of a triple composite of an interconnected porous hydroxyapatite (IP-CHA), recombinant human bone morphogenetic protein-2 (rhBMP-2), and a synthetic biodegradable polymer [poly-d,l-lactic acid/polyethylene glycol (PLA-PEG)] as a carrier for rhBMP-2. In the present study, we evaluated the capacity of the triple composite to induce the regeneration of articular cartilage. METHODS: Full-thickness cartilage defects were created in the trochlear groove of 52 New Zealand White rabbits. Sixteen defects were filled with the bone morphogenetic protein (BMP)/PLA-PEG/IP-CHA composite (group I), 12 with PLA-PEG/IP-CHA (group II), 12 with IP-CHA alone (group III), and 12 were left empty (group IV). The animals were killed 1, 3, and 6 weeks after surgery, and the gross appearance of the defect sites was assessed. The harvested tissues were examined radiographically and histologically. RESULTS: One week after implantation with the BMP/PLA-PEG/IP-CHA composite (group I), vigorous repair had occurred in the subchondral defect. It contained an agglomeration of mesenchymal cells which had migrated from the surrounding bone marrow either directly, or indirectly via the interconnecting pores of the IP-CHA scaffold. At 6 weeks, these defects were completely repaired. The regenerated cartilage manifested a hyaline-like appearance, with a mature matrix and a columnar organization of chondrocytes. CONCLUSIONS: The triple composite of rhBMP-2, PLA-PEG, and IP-CHA promotes the repair of full-thickness articular cartilage defects within as short a period as 3 weeks in the rabbit model. Hence, this novel cell-free implant biotechnology could mark a new development in the field of articular cartilage repair.

Animals↗

Application of three-dimensional magnetic resonance image registration for monitoring hip joint diseases.

The purpose of this study was to estimate the accuracy of a method in which three-dimensional (3D) magnetic resonance (MR) volume registration is used for monitoring hip joint disease. Data were analyzed using a normalized cross-correlation (NCC) algorithm involving a user-selected 3D box including the proximal femur. Most of the femoral head was not included in the 3D box because it can become deformed during the course of disease. The accuracy of registration around the femoral head was evaluated using five phantoms and clinical MR data of 17 patients with hip joint disease. In the phantom experiment, registration accuracy was evaluated using four fiducial markers attached to the femoral head. In the experiment using clinical data, registration accuracy was evaluated using a landmark in the femoral head. The registration accuracy in the phantom and clinical experiment was 0.43+/-0.18 mm (S.D.) and 1.12+/-0.46 mm (S.D.), respectively. The former is a value less than half the minimum dimension of a voxel (1.25 x 1.25 x 1.0 mm). Although the latter is slightly larger than the minimum dimension of a voxel, actual errors would be smaller because of the uncertainty in landmark localization. In conclusion, the present method based on an NCC algorithm can be used to accurately register serial MR images of the femoral heads with an error on the order of a voxel. We believe that this method is sufficiently accurate for monitoring hip joint diseases.

Algorithms↗

In vivo three-dimensional wrist motion analysis using magnetic resonance imaging and volume-based registration.

This study represents a new attempt to non-invasively analyze three-dimensional motions of the wrist in vivo. A volume-based registration method using magnetic resonance imaging (MRI) was developed to avoid radiation exposure. The primary aim was to evaluate the accuracy of volume-based registration and compare it with surface-based registration. The secondary aim was to evaluate contributions of the scaphoid and lunate to global wrist motion during flexion-extension motion (FEM), radio-ulnar deviation (RUD) and radial-extension/ulnoflexion, "dart-throwing" motion (DTM) in the right wrists of 12 healthy volunteers. Volume-based registration displayed a mean rotation error of 1.29 degrees +/-1.03 degrees and a mean translation error of 0.21+/-0.25 mm and was significantly more accurate than surface-based registration in rotation. Different patterns of contribution of the scaphoid and lunate were identified for FEM, RUD, and DTM. The scaphoid contributes predominantly in the radiocarpal joint during FEM, in the midcarpal joint during RUD and almost equally between these joints during DTM. The lunate contributes almost equally in both joints during FEM and predominantly in the midcarpal joint during RUD and DTM.

Biomechanical Phenomena↗

Acute arm paresis with cervical spondylosis: three case reports.

BACKGROUND: The mild type of anterior spinal artery syndrome (ASAS) is characterized by motor loss with an absent or insignificant sensory deficit due to a disturbance in the blood supply to the anterior horn of the spinal cord. The clinical symptoms of cervical spondylotic amyotrophy (CSA) are motor loss or atrophy with an absent or insignificant sensory deficit or a long tract sign; however, the pathophysiology has not been clarified. METHODS: Three patients who suffered from palsy of the deltoid and biceps brachii are presented. Magnetic resonance imaging confirmed the intrinsic cord disease as the cause of the paresis. We measured the central motor conduction time (CMCT) and the latencies of the tendon reflex (T waves) of the biceps and triceps and those of the F waves of the abductor pollicis brevis and abductor digiti minimi before, 2 weeks after, and 3 months after starting intravenous injections of prostaglandin E(1) (PGE(1)). RESULTS: In these 3 cases, restoration of muscle strength began after starting injection of PGE(1). The electrophysiologic diagnosis revealed a disturbance of the motor conduction, in the CMCT and the latencies of the T waves, in the paretic muscle, which is more severe than that in other muscles. The radiological diagnosis suggested damage in the spinal cord. Improvements in the disturbance of the motor conduction and those of symptoms were parallel. CONCLUSION: From symptomatologic or radiological viewpoints, it is difficult to differentiate CSA from ASAS with cervical spondylosis. This suggests that there have been patients with ASAS whom we have diagnosed as CSA, and we may add administration of PGE(1) to the treatment for the patients with CSA. The present 3 patients showed improvement of muscle strength after starting injections of PGE(1). Although this improvement was measured by an electrophysiologic method, the mechanisms of PGE(1) require further study.

Acute Disease↗

Quantification of SSX mRNA expression in human bone and soft tissue tumors using nucleic acid sequence-based amplification.

The SSX family proteins have been considered new members of the cancer/testis antigens because of the restricted expression in testis among normal tissues and the activation in a wide range of cancers. Thus, they would be potential molecular targets for immunotherapeutic strategies. We have developed a competitive nucleic acid sequence-based amplification (NASBA) assay to analyze SSX mRNA expression in 211 bone and soft tissue tumors. The copy numbers of SSX mRNA per mug of total RNA in tumor tissues were widely distributed, ranging logarithmically from 0.6 to 6.6. We found that malignant tumors showed significantly higher expression of SSX mRNA than benign tumors (P < 0.0001). Further, SSX mRNA expression in stage III tumors was significantly higher than that in stage I or II tumors (P < 0.005). This NASBA assay was also more sensitive compared to immunohistochemistry using newly affinity-purified polyclonal antibody against SSX. Collectively, these results suggest that the SSX quantitative NASBA assay could provide useful information to select eligible patients for SSX-specific cancer vaccines.

Adolescent↗

Alendronate inhibits bone resorption at the bone-screw interface.

In the current study, we investigated whether the systemic administration of alendronate, a third-generation bisphosphonate, suppressed the loosening of screws at the bone-screw interface. We systemically administered alendronate to rats fitted with external fixators. External fixators with two half pins were applied to the right femurs of rats, and alendronate was administrated once a week during a 5-week postoperative period. Radiographic, histologic, and immunohistochemical findings subsequently were analyzed. Treatment with alendronate reduced the width of the fibrous loosening membrane and the number of osteoclasts at the bone-screw interface. These findings indicate that systemic treatment with alendronate exerts an inhibitory effect on local bone resorption at the bone-screw interface.

Acid Phosphatase↗

Does three-dimensional computer simulation improve results of scaphoid nonunion surgery?

The purpose of this study was to clarify the effectiveness of the three-dimensional computer simulations in scaphoid nonunion surgery. Seven consecutive clinical patients with scaphoid nonunion at the middle third comprised the study group. Surface models of the scaphoid were constructed on the computer using computed tomography data of the bilateral wrists in neutral position. The distal and proximal fragments of the nonunion model were matched to the mirror image of the contralateral scaphoid model. The rotation of the distal fragment relative to the proximal fragment was calculated, and reduction of the displaced fragment of the scaphoid nonunion was simulated. Similarly, the estimated bone defect and the appropriate site and direction of the screw insertion were simulated. Full-sized hard models of the bone, including a model with simulated reduction and screw insertion, then were made using stereolithography based on the computer data. In the actual surgery, reduction, bone grafting, and screw insertion were achieved using the hard models as guides. All the patients obtained solid bone fusion and substantial clinical improvement with normalized scapholunate and radiolunate angles after surgery. Three-dimensional computer simulations were found as useful for accurate correction of scaphoid nonunions and proper screw placement, which consequently leads to good clinical results.

Adolescent↗

Prognostic relevance of clinical symptoms in patients with spinal metastases.

UNLABELLED: Medical and surgical advances allow surgical treatment of many patients with spinal metastases. Although emerging surgical techniques facilitate stabilization of the collapsed spine, surgical candidates should be carefully selected. However, the lack of confirmed criteria to determine survival of these patients makes selection for surgery difficult. Clinical symptoms have been considered possible factors associated with prognosis, but their relevance has not been confirmed because of inadequate power for proper statistical analysis. We retrospectively reviewed 165 patients who had surgery for spinal metastases from various cancers. Clinical symptoms including pain, paresis, and walking status were recorded. Multivariate analysis indicated that the histologic type of the primary tumor was the strongest prognostic factor, followed by preoperative paresis and pain. Myeloma, thyroid cancer, renal cell cancer, breast cancer, and prostate cancer had better prognoses than other kinds of cancer. Patients without paresis before surgery had a better prognosis than patients with paresis, and patients with no pain before surgery had a better prognosis than those with pain. Preoperative walking status was not an independent prognostic factor. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series--no, or historical control group). See the Guidelines for Authors for a complete description of levels of evidence.

Evidence-Based Medicine↗

Fat-suppressed 3D spoiled gradient-echo MRI and MDCT arthrography of articular cartilage in patients with hip dysplasia.

OBJECTIVE: Our objective was to assess the diagnostic ability of MDCT arthrography for acetabular and femoral cartilage lesions in patients with hip dysplasia. MATERIALS AND METHODS: A disorder of the articular cartilage was evaluated in 20 hips of 18 patients with acetabular dysplasia who did not have osteoarthritis or who had early stage osteoarthritis before undergoing pelvic osteotomy surgery. The findings on fat-suppressed 3D fast spoiled gradient-echo MRI and MDCT arthrography of the hip were evaluated by two independent observers, and sensitivity, specificity, and accuracy were determined using arthroscopic findings as the standard of reference. Kappa values were calculated to quantify the level of interobserver agreement. RESULTS: The sensitivity and specificity for the detection of any cartilage disorder (grade 1 or higher) were (observer 1/observer 2) 49%/67% and 89%/76%, respectively, on MRI, and 67%/67% and 89%/82%, respectively, on CT arthrography. The sensitivity and specificity for the detection of cartilage lesions with substance loss (grade 2 or higher) were (observer 1/observer 2) 47%/53% and 92%/87%, respectively, on MRI, and 70%/79% and 93%/94%, respectively, on CT arthrography. CT arthrography provided significantly higher sensitivity in the detection of grade 2 or higher lesions than MRI for both observers. Interobserver agreement in the detection of grade 2 or higher cartilage lesions was moderate (kappa = 0.53) on MRI and substantial (kappa = 0.78) on CT. CONCLUSION: MDCT arthrography is a sensitive and reproducible method for assessing articular cartilage lesions with substance loss in patients with hip dysplasia.

Adolescent↗

En bloc laminoplasty without dissection of paraspinal muscles.

OBJECT: Although conducting cervical laminoplasty in patients with multisegmental cord compression provides good neurological results, it is not without shortcomings, including C-5 palsy, axial neck pain, and undesirable radiologically detectable changes. Postoperative kyphosis and segmental instability can cause neurological problems and are believed mainly to result from neck muscle disruption. The authors developed a new laminoplasty technique, with the aim of preserving optimal muscle function. METHODS: The present technique is a modification of unilateral open-door laminoplasty. By using an ultrasonic osteotome in small gaps of muscle bellies, a gutter is made without disrupting muscles, spinous processes, or their connections on the hinged side. Ceramic spacers are then positioned between elevated laminae and lateral masses at C-3, C-5, and C-7 on the opened side, which is exposed in a conventional manner. This new procedure was used to treat 37 consecutive patients with compression myelopathy. Postoperative computerized tomography (CT) scanning revealed a significant difference in a cross-sectional area of muscles between the hinged and opened side. The mean follow-up period was 40.2 months (range 24-54 months). Changes in alignment were observed in only one patient, and vertebral slippage developed in two. Performed at regular intervals, CT scanning demonstrated that the elevated laminae remained in situ throughout the study period. CONCLUSIONS: In using the present unilateral open-door laminoplasty technique, deep extensor muscles are left intact along with their junctions to spinous processes on the hinged side. Radiologically documented changes were minimal because the preserved muscles functioned normally immediately after the operation.

Adult↗

The effect of simulated microgravity by three-dimensional clinostat on bone tissue engineering.

Evidence suggests that mechanical stress, including gravity, is associated with osteoblast differentiation and function. To examine effects of microgravity on bone tissue engineering, we used a three-dimensional (3D) clinostat manufactured by Mitsubishi Heavy Industries (Kobe, Japan). A 3D clinostat is a device that generates multidirectional G force. By controlled rotation on two axes, it cancels the cumulative gravity vector at the center of the device. We cultured rat marrow mesenchymal cells (MMCs) in the pores of interconnected porous calcium hydroxyapatite (IP-CHA) for 2 weeks in the presence of dexamethasone using the 3D clinostat (clinostat group). MMCs cultured using the 3D clinostat exhibited a 40% decrease in alkaline phosphatase activity (a marker of osteoblastic differentiation), compared with control static cultures (control group). SEM analysis revealed that although there was no difference between the two groups in number or distribution of cells in the pores, the clinostat group exhibited less extensive extracellular matrix formation than the control group. Cultured IP-CHA/MMC composites were then implanted into subcutaneous sites of syngeneic rats and harvested 8 weeks after implantation. All implants showed bone formation inside the pores, as indicated by decalcified histological sections and microfocus computed tomography. However, the volume of newly formed bone was significantly lower for the clinostat group than for the control group, especially in the superficial pores close to the implant surface. These results indicate that new bone formation in culture was inhibited by use of the 3D clinostat, and that this inhibition was mainly due to suppression of osteoblastic differentiation of MMCs.

Animals↗