[Development of method to estimate delay time for arterial imput function with [15O]CO2-PET study using sinogram data and attenuation map].

The difference in tracer arrival times between the external radiation detector and the brain following administration of radioactivity (delay time) must be estimated correctly in order to quantitatively measure regional cerebral blood flow (rCBF) with positron emission tomography and [15O]H2O by autoradiographic method. Instead of intervenous injection of [15O]H2O, bolus inhalation of [15O]CO2 gas is sometimes used to simplify the measurement of rCBF. In the case of [15O]CO2, radioactive gas in mask and nasal cavity contributes large artifact on the sinogram data and it is difficult to estimate delay time from the sinogram data. In this paper, we proposed a new method to estimate the delay time using the sinogram data and the attenuation map (attenuation weighted sinogram method). In the present method, the attenuation map was used to eliminate the effect of the gas outside the brain region from the sinogram data. For the validation of the present method, PET data with [15O]CO2 (n = 10) were analyzed. Three methods, namely the image method, the sinogram method and the attenuation weighted sinogram method were used to estimate the delay time. The estimated delay times and calculated rCBF images by three methods were compared. Due to the radioactivity outside of the brain, the sinogram method significantly overestimated the delay time and thus underestimated the rCBF value compared with the image base method. On the other hand, there were good agreements between the delay times estimated by the attenuation weighted sinogram method and the image method. The present method can eliminate the effect of the radioactivity outside of the brain on the sinogram data and estimate the delay time accurately and fast enough for clinical use.

Autoradiography↗

(18)F-FDG accumulation in atherosclerotic plaques: immunohistochemical and PET imaging study.

UNLABELLED: The rupture of atherosclerotic plaques and the subsequent formation of thrombi are the main factors responsible for myocardial and cerebral infarctions. Thus, the detection of vulnerable plaques in atherosclerotic lesions is a desirable goal, and attempts to image these plaques with (18)F-FDG have been made. In the present study, the relationship between the accumulation of (18)F-FDG and the biologic characteristics of atherosclerotic lesions was investigated. Furthermore, PET imaging of vulnerable plaques was performed with an animal model of atherosclerosis, Watanabe heritable hyperlipidemic (WHHL) rabbits. METHODS: WHHL (n = 11) and control (n = 3) rabbits were injected intravenously with (18)F-FDG, and the thoracic and abdominal aortas were removed 4 h after injection. The accumulated radioactivity was measured, and the number of macrophages and the intimal area were investigated by examination of stained sections. PET and CT images were also acquired at 210 min after injection of the radiotracer. RESULTS: (18)F-FDG accumulated to a significantly higher level in the aortas of the WHHL rabbits (mean +/- SD differential uptake ratio [DUR], 1.47 +/- 0.90) than in those of the control rabbits (DUR, 0.44 +/- 0.15); DUR was calculated as (tissue activity/tissue weight)/(injected radiotracer activity/animal body weight), with activities given in becquerels and weights given in kilograms. (18)F-FDG uptake and the number of macrophages were strongly correlated in the atherosclerotic lesions of the WHHL rabbits (R = 0.81). In the PET analysis, intense (18)F-FDG radioactivity was detected in the aortas of the WHHL rabbits, whereas little radioactivity was seen in the control rabbits. CONCLUSION: The results suggest that macrophages are responsible for the accumulation of (18)F-FDG in atherosclerotic lesions. Because vulnerable plaques are rich in macrophages, (18)F-FDG imaging should be useful for the selective detection of such plaques.

Animals↗

Magnetic resonance spectra of hyperpolarized (129)xe in human blood and living rat chest.

We constructed a gas polarization system to test the feasibility of using hyperpolarized (129)Xe gas as an NMR (nuclear magnetic resonance) probe to explore brain function. Both in vitro and in vivo experiments were performed with a 4.7 T NMR spectrometer. Xenon spectra from human blood confirmed the existence of two peaks corresponding to red blood cells and plasma. In rat studies, three peaks at around 200 ppm were observed. Our results are consistent with previously reported data.

Animals↗

Left atrial versus left ventricular input function for quantification of the myocardial blood flow with nitrogen-13 ammonia and positron emission tomography.

Flow quantitation with nitrogen-13 ammonia ((13)NH(3)) and positron emission tomography (PET) is dependent on an accurate blood time-activity curve. This is conveniently derived from the PET images by drawing a region of interest in the left ventricular cavity. The blood time-activity curve obtained in this way, however, may contain spillover from the myocardial wall. The purpose of this study was to analyse the effect of wall to blood pool spillover. Additionally, we analysed the application of a left atrial input function. Using computer simulations, we investigated the effect of spillover from the myocardial wall to the left ventricular input function and the effect of time delay on the left ventricular input function. An oxygen-15 carbon monoxide PET study of seven normal volunteers was used to investigate possible recovery issues regarding the left atrial input function. Finally, (13)NH(3) studies of 31 normal volunteers during rest and dipyridamole stimulation were analysed using either a left atrial or a left ventricular input function. The simulation studies showed that myocardial wall to blood pool spillover causes a considerable underestimation of the regional blood flow values in hyperaemic flow studies. Neither time delay nor recovery issues prevent flow quantitation with a left atrial input function. The (13)NH(3) studies revealed no significant difference between the resting blood flow values, whereas the hyperaemic blood flow values were underestimated by 8% (P<0.01) on average (up to 40% individually) when using a left ventricular input function compared with a left atrial input function. Spillover of activity from the left ventricular wall to the blood time-activity curve is of importance in hyperaemic flow studies using (13)NH(3). Application of a left atrial input function is a possible solution to these issues.

Ammonia↗

Quantification of nicotinic acetylcholine receptors in human brain using [123I]5-I-A-85380 SPET.

The purpose of this study was to assess the utility of a new single-photon emission tomography ligand, [123I]5-iodo-3-[2(S)-2-azetidinylmethoxy]pyridine (5-I-A-85380), to measure regional nAChR binding in human brain. Six healthy nonsmoker subjects (two men and four women, age 33 +/- 15 years) participated in both a bolus (dose: 317 +/- 42 MBq) and a bolus plus constant infusion (dose of bolus: 98 +/- 32 MBq, B/I=6.7 +/- 2.6 h, total dose: 331 +/- 55 MBq) study. The study duration was 5-8 h and 14 h in the former and the latter, respectively. Nonlinear least-squares compartmental analysis was applied to bolus studies to calculate total (VT') and specific (VS') distribution volumes. A two-tissue compartment model was applied to identify VS'. VT' was also calculated in B/I studies. In bolus studies, VT' was well identified by both one- and two-tissue compartment models, with a coefficient of variation of less than 5% in most regions. The two-compartment model gave VT' values of 51, 22, 27, 32, 20, 19, 20, and 17 ml cm(-3) in thalamus, cerebellum, putamen, pons, and frontal, parietal, temporal, and occipital cortices, respectively. The two-compartment model did not identify VS' well. B/I studies provided poor accuracy of VT' measurement, possibly due to deviations from equilibrium conditions. These results demonstrate the feasibility of quantifying high-affinity type nAChRs using [123I]5-I-A-85380 in humans and support the use of VT' measured by bolus studies.

Adult↗

Accelerated median root prior reconstruction for pinhole single-photon emission tomography (SPET).

Pinhole collimation can be used to improve spatial resolution in SPET. However, the resolution improvement is achieved at the cost of reduced sensitivity, which leads to projection images with poor statistics. Images reconstructed from these projections using the maximum likelihood expectation maximization (ML-EM) algorithms, which have been used to reduce the artefacts generated by the filtered backprojection (FBP) based reconstruction, suffer from noise/bias trade-off: noise contaminates the images at high iteration numbers, whereas early abortion of the algorithm produces images that are excessively smooth and biased towards the initial estimate of the algorithm. To limit the noise accumulation we propose the use of the pinhole median root prior (PH-MRP) reconstruction algorithm. MRP is a Bayesian reconstruction method that has already been used in PET imaging and shown to possess good noise reduction and edge preservation properties. In this study the PH-MRP algorithm was accelerated with the ordered subsets (OS) procedure and compared to the FBP, OS-EM and conventional Bayesian reconstruction methods in terms of noise reduction, quantitative accuracy, edge preservation and visual quality. The results showed that the accelerated PH-MRP algorithm was very robust. It provided visually pleasing images with lower noise level than the FBP or OS-EM and with smaller bias and sharper edges than the conventional Bayesian methods.

Algorithms↗

Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I] p-iodoamphetamine.

We evaluated an autoradiographic (ARG) method to calculate regional cerebral blood flow (rCBF) sequentially before and after an acetazolamide (ACZ) challenge in a single session of single-photon emission tomography (SPET) with two injections of N-isopropyl-[(123)I] p-iodoamphetamine (IMP). The method uses a table look-up method with a fixed distribution volume (Vd) and a standard input function of IMP. To calculate rCBF after an ACZ challenge, two look-up tables (a dual-table) are used to reflect the effect of radioactivity in the brain from the first dose of IMP. We performed simulation studies to evaluate errors attributable to (a) a change in rCBF induced by an ACZ challenge during the scan and (b) a fixed Vd value that might be different from an individual one, along with the effect of (c) scan length. Thirty-three patients were studied by dynamic SPET with two injections of IMP and frequent arterial blood sampling, and the data were analysed using the dual-table ARG method. Twenty-four of the 33 patients received an injection of ACZ 10 min before the second dose of IMP. We generated a standard input function by averaging individual input functions. The optimal method to calibrate a standard input function was determined so that the SD of differences between rCBF calculated by using a calibrated standard input function (F(SIF)) and that calculated by using an individual input function (F(IIF)) was minimised. Reliability of the method was evaluated by comparing F(SIF) with gold standard rCBF (F(REF)) obtained by two-compartment model analysis of dynamic SPET data and an individual input function with a non-linear least squares fitting method. Errors caused by (a) were less than 4% for a first rCBF ranging between 20 and 60 ml 100 g(-1) min(-1) and an rCBF change of between -25% and 50%. Errors caused by (b) were relatively large compared with those caused by (a), and were affected by (c) with an increasing error in a longer scan. In the patient study with a proposed scan protocol of 25 min for the first and 15 min for the second measurement, the error attributable to the standard input function was smaller when calibrated with a continuously drawn arterial blood sample (random error of 3.8% for continuous 10-min arterial blood sampling after the second dose of IMP) than with a single arterial blood sample (random error of 9.0% at 5 min after the second dose of IMP). Systematic and random errors of F(SIF) compared with F(REF) were 0.0% and 6.3%, respectively. The dual-table ARG method can be reliably used to quantify rCBF before and after an ACZ challenge with a 40-min scan protocol and continuous arterial blood sampling for several minutes.

Acetazolamide↗

Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation.

In quantitative pinhole SPECT, photon penetration through the collimator edges (penetration), and photon scattering by the object (object scatter) and collimator (collimator scatter) have not been investigated rigorously. Monte Carlo simulation was used to evaluate these three physical processes for different tungsten knife-edge pinhole collimators using uniform, hotspot and donut phantoms filled with 201Tl, 99mTc, 123I and 131I solutions. For the hotspot phantom, the penetration levels with respect to total counts for a 1 mm pinhole aperture were 78%, 28% and 23% for 131I, 123I and 99mTc, respectively. For a 2 mm aperture, these values were 65% for 131I, 16% for 123I and 12% for 99mTc. For all pinholes, 201Tl penetration was less than 4%. The evaluated scatter (from object and collimator) with a hotspot phantom for the 1 mm pinhole was 24%, 16%, 18% and 13% for 201Tl, 99mTc, 123I and 131I, respectively. Summation of the object and collimator scatter for the uniform phantom was approximately 20% higher than that for the hotspot phantom. Significant counts due to penetration and object and collimator scatter in the reconstructed image were observed inside the core of the donut phantom. The collimator scatter can be neglected for all isotopes used in this study except for 131I. Object scatter correction for all radionuclides used in this study is necessary and correction for the penetration contribution is necessary for all radionuclides but 201Tl.

Absorption↗

Dependency of energy and spatial distributions of photons on edge of object in brain SPECT.

OBJECTIVES: Accurate mu maps are important for quantitative image reconstruction in SPECT. The Compton scatter energy window (CSW) technique has been proposed to define the outline of objects. In this technique, a lower energy window image is acquired in addition to the main photo-peak energy window. The image of the lower energy window is used to estimate the edge of the scanned object to produce a constant attenuation map. The aim of this study was to investigate the dependency of CSW on the spatial and energy distribution of radioisotope to predict the edges of objects. METHODS: Two particular cases of brain study were considered, namely uniform distribution and non-uniform distribution using Monte Carlo simulation and experiments with uniform cylindrical phantom and hotspot phantom. The phantoms were filled with water and a radioactive solution of 99mTc. For each phantom, 20%, 30%, 40% and 50% thresholds of the mean profile were applied to estimate Ewt, the energy window for minimum difference between the estimated and true edge of objects. RESULTS: The Ewt's were 100-120 keV with a 40% threshold and 92-114 keV with a 30% threshold for uniform and hotspot phantoms, respectively. CONCLUSIONS: Edge of the objects with CSW technique varies with energy window and thresholds. Careful setting of the energy window is required to use the CSW technique.

Algorithms↗

Activation of the anterior cingulate gyrus by 'Green Odor': a positron emission tomography study in the monkey.

The equivalent mixture of cis-3-hexenol and trans-2-hexenal (hexenol/hexenal), 'green odor', is known to have a healing effect on the psychological damage caused by stress. Behavioral studies in humans and monkeys have revealed that hexenol/hexenal prevents the prolongation of reaction time caused by fatigue. In the present study, we investigated which brain regions are activated by the odor of hexenol/hexenal using positron emission tomography with alert monkeys. Regional cerebral blood flow (rCBF) in the prepyriform area (the primary olfactory cortex) was commonly increased by the passive application of odor: acetic acid, isoamylacetate or hexenol/hexenal. We observed rCBF increases in the orbitofrontal cortex (the secondary olfactory cortex) by these olfactory stimuli in two of three monkeys, and found no predominance of laterality of the activated hemisphere. Furthermore, rCBF increase in the cerebellum was observed in two of three monkeys, and the odor of acetic acid increased rCBF in the substantia innominata in all monkeys. In addition to these olfactory related regions, the anterior cingulate gyrus was activated by the odor of hexenol/hexenal. These findings suggest that the increase of rCBF in the anterior cingulate gyrus by the odor of hexenol/hexenal may contribute the healing effects of this mixture observed in the monkey.

Aldehydes↗

Development of injectable O-15 oxygen and estimation of rat OEF.

Cerebral metabolic rate for oxygen (CMRO(2)) and cerebral oxygen extraction fraction (OEF) are some of the most fundamental parameters to characterize the pathophysiologic status of cerebral tissue. Although O-15-labeled gases inhalation method is performed in clinical studies, application of the inhalation method on small animals requires too many intensive procedures. On this basis, the development of a new method to measure CMRO(2) and OEF in small animals is of interest. This study was aimed at developing a method to assess CMRO(2) and OEF using intravenously injectable oxygen (injectable 15O-O(2)) for small animals such as rats. Injectable 15O-O(2), 72 MBq/mL of radioactivity, was obtained after 15O-O(2) gas circulation into the artificial lung. OEF after injection of injectable 15O-O(2) was calculated using the same equation as that applied to the bolus inhalation of 15O-O(2) gas method. Values of 44 +/- 4.5 mL. min-1. 100 g-1 of CBF and 0.54 +/- 0.11 of OEF were obtained (n = 13). This OEF value was well accordance with OEF evaluated by arterial-venous difference of oxygen concentration (0.57 +/- 0.13). This method is useful to study the CMRO(2) and OEF in small animals using an animal positron emission tomography system. It may accelerate the basic research of several cerebral perfusion diseases.

Animals↗

A theoretical model of oxygen delivery and metabolism for physiologic interpretation of quantitative cerebral blood flow and metabolic rate of oxygen.

The coupling of cerebral blood flow (CBF) and metabolic rate of oxygen (CMRO2) during physiologic and pathophysiologic conditions remains the subject of debate. In the present study, we have developed a theoretical model for oxygen delivery and metabolism, which describes the diffusion of oxygen at the capillary-tissue interface and the nonlinear nature of hemoglobin (Hb) affinity to oxygen, allowing a variation in simple-capillary oxygen diffusibility, termed "effective oxygen diffusibility (EOD)." The model was used to simulate the relationship between CBF and CMRO2, as well as oxygen extraction fraction (OEF), when various pathophysiologic conditions were assumed involving functional activation, ischemia, hypoxia, anemia, or hypo- and hyper-capnic CBF variations. The simulations revealed that, to maintain CMRO2 constant, a variation in CBF and Hb required active change in EOD. In contrast, unless the EOD change took place, the brain allowed small but significant nonlinear change in CMRO2 directly dependent upon oxygen delivery. Application of the present model to quantitative neuroimaging of CBF and CMRO2 enables us to evaluate the biologic response at capillary level other than Hb- and flow-dependent properties of oxygen transport and may give us another insight regarding the physiologic control of oxygen delivery in the human brain.

Biological Transport↗

Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities.

UNLABELLED: Correction of scatter and attenuation is essential for quantitative SPECT. In this work, we evaluated the accuracy gained from a method of transmission-dependent convolution subtraction (TDCS) in the quantitation of activity that is highly concentrated in the striatum (STR). METHODS: SPECT data were acquired from an (123)I-containing phantom with a constant activity in the STR but differing background (BKG) activities, so as to simulate various STR/BKG ratios (19.7:1, 9.7:1, 4.8:1, 1.9:1, and 1:1). In a study of healthy humans (n = 6), a transmission scan followed by an emission scan was performed 24 h after injection of (123)I-2beta-carbomethoxy-3beta-(4-iodophenyl)-tropane ((123)I-beta-CIT). All SPECT data was reconstructed with ordered-subset expectation maximization. TDCS was applied for scatter correction. Values of activity in the STR and occipital lobe (for BKG) were used to calculate binding potential V(3)" (= [STR - BKG]/BKG). The effect of SPECT collimator dependency on scatter correction was also evaluated for 6 collimators from 3 different SPECT cameras in the phantom experiment. RESULTS: Scatter correction in the phantom experiment increased the measured values of STR activity (36.2%), resulting in a substantial increase in V(3)" (66.1%). Scatter and attenuation corrections with recovery correction showed an overall bias of -7.3% for the STR, -4.0% for BKG activity, and -7.8% for V(3)". TDCS corrections of phantom activities were relatively uniform for the 6 different collimators, with variabilities of <5.5% for the STR and <3.0% for BKG activities. TDCS correction of human (123)I-beta-CIT images was of a similar, although slightly larger, magnitude than for the phantom data, with increased V(3)" values of 9.4 +/- 2.3 and 4.9 +/- 0.6, with and without scatter correction, respectively. CONCLUSION: The TDSC method significantly improved the accuracy of SPECT images with a nonuniform distribution of activity highly concentrated in central regions. The value of V(3)" was significantly increased in phantom and human data, with most of the improvement derived from an increase in STR activity. This scatter correction method was approximately equally useful with data from the 6 different collimators and is recommended for more accurate quantitation of nonuniformly distributed brain activities.

Adult↗

The effect of nitroglycerin on myocardial blood flow in various segments characterized by rest-redistribution thallium SPECT.

UNLABELLED: The use of nitrates is reported to be effective in viability detection in scintigraphic perfusion imaging. The purpose of the study was to evaluate the effect of nitroglycerin (NTG) on myocardial blood flow (MBF) and coronary vascular resistance (CVR) in various segments characterized by rest-redistribution (201)Tl SPECT. METHODS: Twenty-three patients with coronary artery disease underwent rest-redistribution (201)Tl SPECT and (15)O-labeled water PET at rest and after NTG spray (0.3 mg). In addition, 11 healthy volunteers were also studied using PET. RESULTS: NTG did not change global MBF in the volunteers or in the patients. In segments with normal (201)Tl uptake and in those with a severe irreversible (201)Tl defect, NTG significantly reduced MBF without changing CVR. NTG reduced CVR in segments with a reversible (201)Tl defect (141 +/- 50 to 114 +/- 29 mm Hg/[mL/min/g], P = 0.004) and in those with a mild-to-moderate irreversible (201)Tl defect (165 +/- 64 to 149 +/- 60 mm Hg/[mL/min/g], P = 0.003), while maintaining MBF. CONCLUSION: NTG preferentially reduces CVR in the viable myocardium with ischemia. After NTG, tracer uptake in the ischemic myocardium will be relatively increased compared with that in the nonviable and nonischemic myocardium, leading to improvements in viability detection.

Aged↗

Regional changes in human cerebral blood flow during dipyridamole stress: neural activation in the thalamus and prefrontal cortex.

Intravenous dipyridamole increases the concentration of circulating adenosine and produces coronary vasodilation. However, it decreases global cerebral blood flow (CBF) due to hyperventilation side effect of adenosine. In the present study, changes in regional CBF during dipyridamole stress were identified in detail. In 11 healthy men (51-71 years of age), CBF was measured by positron emission tomography with oxygen-15-labeled water at rest (baseline) and during dipyridamole stress. All images were normalized to global CBF and transformed to standard brain anatomy. A t map between baseline and dipyridamole stress conditions was then created on a pixel-by-pixel basis. CBF was globally decreased during dipyridamole stress. However, a significant relative increase in CBF was observed bilaterally in the thalamus and prefrontal cortex, indicating neural activation in these regions. Adenosine plays an important role in the production of anginal pain by stimulation of A(1) adenosine receptors. Neural activation in the thalamus and prefrontal cortex during angina pectoris has been reported. Although no subject felt chest pain during dipyridamole stress, neural activation in the thalamus and prefrontal cortex indicates that stimulation of A(1) adenosine receptors during dipyridamole stress may produce input from the heart to the thalamus through the vagal fiber.

Blood Pressure↗

Evaluation of a commercial PET tomograph-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labeled compounds.

The purpose of this study was to develop a reliable and practical strategy that generates quantitative CBF and OEF maps accurately from PET data sets obtained with 15O-tracers. Sequential sinogram data sets were acquired after the administration of 15O-tracers, and combined single-frame images were obtained. The delay time between sampled input function and the brain was estimated from the H2(15)O study with the whole brain and the arterial time-activity curves (TACs). The whole-brain TACs were obtained from the reconstructed images (image-base method) and the sinogram data (sinogram-base method). Six methods were also evaluated for the dead-time and decay correction procedures in the process of generating a single-frame image from the dynamic sinogram. The estimated delay values were similar with both the sinogram-based and image-based methods. A lumped correction factor to a previously added single-frame sinogram caused an underestimation of CBF, OEF and CMRO2 by 16% at maximum, as compared with the correction procedure for a short sinogram. This suggested the need for a dynamic acquisition of a sinogram with a short interval. The proposed strategy provided an accurate quantification of CBF and OEF by PET with 15O-tracers.