Search PubMedSearch

Biomedical subjects

Helen C Miranda

Publications and source records attributed to Helen C Miranda.

2 recordsLinked to original sources

Convergent activation of the integrated stress response and ER-mitochondria uncoupling in VAPB-associated ALS.

Vesicle-associated membrane protein-associated protein-B (VAPB) is an endoplasmic reticulum (ER) membrane-bound protein. The P56S mutation in VAPB causes a dominant, familial form of amyotrophic lateral sclerosis (ALS). However, the mechanism by which this mutation leads to motor neuron (MN) degeneration remains unclear. Utilizing inducible pluripotent stem cell (iPSC)-derived MNs expressing either wild-type (WT) or P56S VAPB, we demonstrate that the mutant protein reduces neuronal firing and disrupts ER-mitochondria-associated membranes (ER MAMs), with a time-dependent decline in mitochondrial membrane potential (MMP), hallmarks of MN pathology. These findings were validated in patient-derived iPSC-MNs. Additionally, VAPB P56S MNs show increased susceptibility to ER stress, elevated expression of the Integrated Stress Response (ISR) regulator ATF4 under stress, and reduced global protein synthesis. Notably, pharmacological ISR inhibition using ISRIB rescued ALS-associated phenotypes in both VAPB P56S and patient-derived iPSC-MNs. We present the first evidence that the VAPB P56S mutation activates ISR signaling via mitochondrial dysfunction in human MNs. These findings support ISR modulation as a strategy for ALS intervention and highlight the need for patient stratification in clinical trials.

Amyotrophic Lateral Sclerosis

Multiplexed microfluidic chip for cell co-culture.

Paracrine signaling is challenging to study in vitro, as conventional culture tools dilute soluble factors and offer little to no spatiotemporal control over signaling. Microfluidic chips offer potential to address both of these issues. However, few solutions offer both control over onset and duration of cell-cell communication, and high throughput. We have developed a microfluidic chip designed to culture cells in adjacent chambers, separated by valves to selectively allow or prevent exchange of paracrine signals. The chip features 16 fluidic inputs and 128 individually-addressable chambers arranged in 32 sets of 4 chambers. Media can be continuously perfused or delivered by diffusion, which we model under different culture conditions to ensure normal cell viability. Immunocytochemistry assays can be performed in the chip, which we modeled and fine-tuned to reduce total assay time to 1 h. Finally, we validate the use of the chip for co-culture studies by showing that HEK293Ta cells respond to signals secreted by RAW 264.7 immune cells in adjacent chambers, only when the valve between the chambers is opened.

Microfluidics