Search PubMed⌕ Search

Biomedical subjects

Heinrich Wieneke

Publications and source records attributed to Heinrich Wieneke.

28 records · Page 2Linked to original sources

Determinants of coronary blood flow in humans: quantification by intracoronary Doppler and ultrasound.

The direct determinants of coronary flow are lumen area and blood flow velocity; however, the precise mechanisms that control these factors are not fully understood. The aim of the present study was to assess by which mechanisms lumen area and coronary flow velocity interact with hemodynamic and morphometric factors, thereby influencing coronary flow. Intracoronary Doppler and ultrasound measurements were performed in 28 patients without coronary lumen irregularities. Flow velocity and lumen cross-sectional area were measured in the proximal segments of all three coronary arteries. Global lumen cross-sectional area and global flow were obtained by adding up the values of all three coronary arteries. Left ventricular mass was assessed by echocardiography. Stress-mass-heart rate and pressure-rate products reflecting myocardial oxygen demand were calculated. Global coronary flow increased during adenosine-induced hyperemia from 197 +/- 72 to 637 +/- 204 ml/min (P < 0.001). Global coronary flow closely correlated with the stress-mass-heart rate product (r = 0.62; P < 0.001). Looking at the two constituents of flow separately, global coronary cross-sectional area was closely related to left ventricular muscle mass (r = 0.61; P < 0.001), whereas mean coronary flow velocity at rest showed a strong linear relation with the pressure-rate product (r = 0.64; P < 0.001). There was no interaction between cross-sectional area and blood flow velocity in any of the coronary vessels. Coronary lumen size and flow velocity, the two determinants of coronary flow, are principally determined by different physiological factors. Long-term flow adaptation is achieved by an increase in coronary lumen size, whereas short-term myocardial oxygen requirements are met by changes in resting flow velocity.

Blood Flow Velocity↗

Relationship between cardiovascular risk as predicted by established risk scores versus plaque progression as measured by serial intravascular ultrasound in left main coronary arteries.

BACKGROUND: Intravascular ultrasound (IVUS) is increasingly used as an end point in studies aimed at reducing progression or inducing regression of coronary artery disease. However, data linking serial changes by IVUS with clinical outcomes are scarce. METHODS AND RESULTS: In the absence of a validated risk score for secondary prevention, we compared 3 established risk scores for primary prevention--PROCAM, SCORE, and Framingham--with plaque progression and lumen reduction as assessed with serial IVUS (follow-up, 18+/-9 months) in atherosclerotic left main coronary arteries of 56 patients with established atherosclerosis. For all 3 algorithms, patients at highest estimated risk of events showed greater plaque progression than patients at lowest risk (P<0.05 to <0.01). There were positive linear relationships between the risk of clinical events and plaque progression (r=0.41 to 0.60; P<0.002 to <0.0001). This translated into a greater decrease in lumen dimensions with increasing risk (P<0.05, PROCAM and SCORE). Risk prediction using the PROCAM algorithm showed the strongest relation with serial IVUS. During follow-up, 18 patients suffered from adverse cardiovascular events; these patients had an annual plaque progression that was significantly greater than other patients (25.2+/-19.4% versus 5.9+/-15.6%, P<0.001). CONCLUSIONS: There was a positive linear relationship between the estimated risk of clinical events derived from all 3 established risk-score algorithms and the extent of plaque progression measured by serial IVUS. This translated into stenosis progression (reduction in lumen dimensions) with increasing clinical risk.

Aged↗

Spectrum of remodeling behavior observed with serial long-term (>/=12 months) follow-up intravascular ultrasound studies in left main coronary arteries.

Most intravascular ultrasound (IVUS) studies of arterial remodeling in native coronary arteries reported a remodeling index obtained at a single time point. We analyzed serial IVUS examinations, including the vessel cross-sectional area changes (remodeling behavior), of 60 hemodynamically nonstenotic left main lesions (baseline vs 18.4 +/- 9.4 months follow-up). Lumen reduction resulted from vessel reduction (sometimes despite plaque + media decrease), plaque + media increase (with or without vessel increase), or both. The percent annual changes in lumen area correlated strongly with changes in vessel (r = 0.84), but not with changes in plaque + media area. Plaques were classified as group A lesions, reflecting positive remodeling behavior (vessel changes >0), or group B lesions, reflecting negative (or intermediate) remodeling behavior (vessel changes <==0). Both groups did not differ significantly in demographics, laboratory data, and medications. Group A lesions (n = 40) more often showed plaque + media increase than group B lesions (32 of 40 [80%] vs 9 of 20 [45%]; p = 0.02). Group A lesions had, on average, mild annual lumen increase despite mild plaque + media increase, i.e, overcompensation of remodeling for plaque + media increase (vessel increase greater than plaque + media area increase, 19 of 40 [47%]). Conversely, group B lesions (n = 20) showed a significant lumen area reduction (-2.8 +/- 2.6 mm(2)/year) as a result of a decrease in vessel area only. Thus, serial long-term reduction of lumen size may result from vessel shrinkage (sometimes despite plaque decrease), plaque increase (with or without vessel increase), or both; overall, only the remodeling behavior has a significant relation to lumen changes. More than 30% of lesions show a negative remodeling behavior, which shows no relation to patient characteristics or initial plaque burden.

Aged↗

Impact of gender on femoral access complications secondary to application of a collagen-based vascular closure device.

BACKGROUND: Vascular complications at the femoral access site continue to be a significant problem after cardiac catheterization procedures. It was the aim of the present study to assess the impact of gender on the incidence of severe femoral access complications following the application of a collagen-based vascular closure device after transfemoral catheterization procedures. METHODS: A total of 1,294 consecutive patients (977 male, 317 female) underwent closure of femoral access sites with 8F collagen-based vascular closure devices (Angioseal) immediately after diagnostic or interventional coronary catheterization procedures, independently of the coagulation status. All patients were closely monitored for the occurrence of complications during the following 24 hours. RESULTS: Between male and female patients, there was no difference in the technical performance of the device with successful deployment being achieved in 96.7% and 95.9%, respectively (p=0.60). Severe access complications were found to be significantly higher in female versus male patients (1.6% vs. 0.2%; Odds ratio 7.7, 95% confidence interval 1.5-40.1; p=0.015), although similar accomplishment of an immediate hemostasis was seen in 92.8% and 92.4% of male and female patients (p=0.98). CONCLUSION: Women show a significantly increased risk of developing severe femoral access complications secondary to the application of a collagen-based vascular closure device, although the overall incidence of these complications is relatively low. We speculate that the increased risk in women may be related to smaller arterial dimensions, which could be evaluated by femoral angiography prior to deployment of a closure device.

Adult↗

Preintervention arterial remodeling affects vessel stretch and plaque extrusion during coronary stent deployment as demonstrated by three-dimensional intravascular ultrasound.

The mechanisms of lumen enlargement during stent implantation may be significantly affected by arterial remodeling. To assess effects of lesion remodeling, we performed 3-dimensional intravascular ultrasound (IVUS) analyses in 55 coronary lesions before and after deployment of balloon-expandable stents. Standard quantitative analysis was performed, and arterial remodeling was assessed by the remodeling index (target site divided by mean of proximal and distal reference segment vessel areas), which classified lesions into group A (remodeling index < or =1, negative or intermediate remodeling, n = 40) or group B (remodeling index >1, positive remodeling, n = 15) lesions. Characteristics of the 55 patients and the interventional procedures were similar in the 2 groups. IVUS demonstrated that stenting resulted in increased lumen and vessel dimensions and in a reduced plaque size (p < or =0.001 each) in both group A and group B lesions. The extent of lumen increase inside the stents was almost identical, but resulted from different mechanisms: (1) vessel stretch was greater in group A (p <0.002 at minimum lumen site); (2) plaque compression (or embolization) tended to be greater in group B (p = 0.05, along entire stented segment); (3) plaque redistribution within the stent was observed in both groups (p <0.005 both); and (4) significant (p <0.01) plaque extrusion into the distal reference segment was found in group B only. Thus, the remodeling pattern of coronary lesions has a significant impact on the mechanisms of lumen enlargement during stent deployment. Lesions with positive remodeling show more plaque extrusion into the distal reference and less stent-induced vessel stretch than those with negative remodeling.

Aged↗

Impact of moderate lesion calcium on mechanisms of coronary stenting as assessed with three-dimensional intravascular ultrasound in vivo.

Axial plaque redistribution is an important mechanism of lumen enlargement after stenting of noncalcified lesions. To assess effects of lesion calcification on mechanisms of coronary stenting, we analyzed 55 lesions with noncircumferential calcification with 3-dimensional intravascular ultrasound (IVUS) (standard qualitative and quantitative analyses) before and after implantation of balloon-expandable stents. Thirty-two plaques (58%) showed arcs of calcium <120 degrees of vessel circumference (group A), whereas 23 lesions (42%) contained arcs of calcium > or =120 degrees of vessel circumference (group B). In the entire cohort of 55 lesions, as well as groups A and B, which were studied separately, both single-slice IVUS analysis (performed at minimum lumen site before intervention) and mean stented segment IVUS analysis showed an increase in lumen and vessel area and a decrease in plaque area (p <0.001). The magnitude of lumen and vessel increase and of plaque decrease was similar in both groups. Group A lesions showed significant plaque extrusion into the distal reference segment that was not observed in group B (increase in plaque area of 1.3 +/- 1.9 vs 0.1 +/- 2.0 mm(2), p <0.04). Stenting did not alter plaque area of the proximal reference segment in either group. In addition, there was an increase in vessel area of the distal reference of both groups, indicating that stent-induced vessel expansion observed within the lesion also affected the distal reference. Thus, longitudinal plaque redistribution and vessel expansion contribute to increased lumen dimensions during stenting of lesions with varying amounts of calcium; however, marked plaque extrusion was found only in lesions with a calcium arc of <120 degrees.

Aged↗

Synergistic effects of a novel nanoporous stent coating and tacrolimus on intima proliferation in rabbits.

To overcome the problem of in-stent restenosis, the concept of local delivery of antiproliferative or immunosuppressive drugs has been introduced into interventional cardiology. Local drug delivery can be achieved by drug-eluting stents coated with polymer surfaces used for controlled drug release. However, several polymer coatings have shown an induction of inflammatory response and increased neointima formation. In the present study, the effect of a new inorganic ceramic nanoporous aluminum oxide (Al(2)O(3)) coating on neointima proliferation and its suitability as a carrier for the immunosuppressive drug tacrolimus have been investigated. 316 L stainless steel coronary stents were coated with a 500 nm thin nanoporous aluminum oxide layer. This ceramic nanolayer was used as a carrier for tacrolimus. Bare stents (n = 6), ceramic coated stents (n = 6), and ceramic coated stents loaded with 60 (n = 7) and 120 mug (n = 6) tacrolimus were implanted in the common carotid artery of New Zealand rabbits. The ceramic coating caused no significant reduction of neointimal thickness after 28 days. Loading the ceramic stents with tacrolimus led to a significant reduction of neointima thickness by 52% for 60 mug (P = 0.047) and 56% for 120 mug (P = 0.036) as compared to the bare stents. The ceramic coating alone as well as in combination with tacrolimus led to a reduced infiltration of lymphocytes and macrophages in the intima in response to stent implantation. Ceramic coating of coronary stents with a nanoporous layer of aluminum oxide in combination with tacrolimus resulted in a significant reduction in neointima formation and inflammatory response. The synergistic effects of the ceramic coating and tacrolimus suggest that this new approach may have a high potential to translate into clinical benefit.

Animals↗

Therapeutic potential of active stent coating.

Various clinical studies have shown the superiority of stent implantation as compared to conventional balloon angioplasty for the treatment of significant coronary stenosis. However, restenosis remains a major drawback of this interventional technique. Against the background of this serious problem, the concept of stent coating has been developed. In general, coatings can be classified into two types: passive coatings, which only serve as a barrier between the stainless steel, and the tissue and active coatings, which directly interfere with the process of intima proliferation. At this moment, primarily immunosuppressive and cytostatic substances are used as active coatings. Large randomised studies have shown that this novel concept can be successfully implemented into clinical practice. Beside these promising results, studies also revealed potential risks of this new approach. Not only the dosage of the drug but also an optimised kinetic of drug release seem to be essential in preventing restenosis. As with most drugs, the inhibition of neointima proliferation is not restricted to vascular smooth muscle cells but also affects the process of re-endothelialisation, thus we may face a new pitfall of late-stent thrombosis. Although this technique may harbour potential risks, the introduction of stent coating has the potential to dramatically reduce the incidence of restenosis and an exciting chapter in the field of cardiology has been opened.

Angioplasty↗

Stent coating: a new approach in interventional cardiology.

BACKGROUND: Since its introduction in clinical cardiology, several studies have shown the superiority of coronary stent implantation as compared to conventional angioplasty. However, restenosis still remains a major drawback of this new technique. Basic research in animal models could identify stent-related factors like stent-material and stent-design as major determinants of intima proliferation. Since materials with good biocompatibility often have unsuitable mechanical properties and vice versa, the concept of stent coating has been developed to allow the combination of favorable characteristics from different materials. PASSIVE COATING: In general, passive coatings, which only serve as a barrier between the stainless steel and the tissue, and active coatings, which directly interfere with the process of intima proliferation have been identified. Currently there are several passive coatings commercially available with good results in animal models and preliminary reports from clinical studies. ACTIVE COATING: As any surface induces some kind of tissue reaction promoting restenosis, an active stent coating with antiproliferative drugs has been proposed. However, while animal studies revealed convincing results, preliminary clinical studies not only showed active stent coating effective in preventing restenosis, but also demonstrated the potential risks of this new approach. Although this technique may harbor some specific risks, with the introduction of stent coating a new chapter of interventional cardiology has been flipped open.

Angioplasty, Balloon, Coronary↗