Search PubMed⌕ Search

Biomedical subjects

Heber MacMahon

Publications and source records attributed to Heber MacMahon.

At least 19 recordsLinked to original sources

Computer-aided diagnosis for the detection and classification of lung cancers on chest radiographs ROC analysis of radiologists' performance.

RATIONALE AND OBJECTIVES: The aim of the study is to investigate the effect of a computer-aided diagnostic (CAD) scheme on radiologist performance in the detection of lung cancers on chest radiographs. MATERIALS AND METHODS: We combined two independent CAD schemes for the detection and classification of lung nodules into one new CAD scheme by use of a database of 150 chest images, including 108 cases with solitary pulmonary nodules and 42 cases without nodules. For the observer study, we selected 48 chest images, including 24 lung cancers, 12 benign nodules, and 12 cases without nodules, from the database to investigate radiologist performance in the detection of lung cancers. Nine radiologists participated in a receiver operating characteristic (ROC) study in which cases were interpreted first without and then with computer output, which indicated locations of possible lung nodules, together with a five-color scale illustrating the computer-estimated likelihood of malignancy of the detected nodules. RESULTS: Performance of the CAD scheme indicated that sensitivity in detecting lung nodules was 80.6%, with 1.2 false-positive results per image, and sensitivity and specificity for classification of nodules by use of the same database for training and testing the CAD scheme were 87.7% and 66.7%, respectively. Average area under the ROC curve value for detection of lung cancers improved significantly (P = .008) from without (0.724) to with CAD (0.778). CONCLUSION: This type of CAD scheme, which includes two functions, namely detection and classification, can improve radiologist accuracy in the diagnosis of lung cancer.

Clinical Competence↗

Improving radiologists' recommendations with computer-aided diagnosis for management of small nodules detected by CT.

RATIONALE AND OBJECTIVES: To evaluate how computer-aided diagnosis (CAD) can improve radiologists' recommendations for management of possible early lung cancers on CT. MATERIALS AND METHODS: Twenty-eight lung cancers and 28 benign lesions were employed. Each group of 28 lesions was classified into subgroups of two sizes (9 between 6 and 10 mm and 19 between 11 and 20 mm) and three patterns (8 with pure ground glass opacity [GGO], 12 with mixed GGO and 8 solid lesions). Sixteen radiologists participated in the observer study, first without and then with CAD. Radiologists' recommendations, including (1) follow-up in 12 months, (2) in 6 months, (3) in 3 months, or (4) biopsy, were compared at three levels of their malignancy probability ratings (low: 1%-33%; medium: 34%-66%; high: 67%-99%) for 896 observations (56 lesions by the 16 radiologists) in the two size subgroups and three patterns. RESULTS: The number of recommendations changed by radiologists by use of CAD was 163 (18%) among all 896 observations. Among these changed recommendations, the fraction showing a beneficial effect from CAD was 68% (111/163), and the fraction showing a beneficial effect regarding biopsy recommendations was 69% (48/70). With CAD, the radiologists' performance regarding biopsy recommendations was significantly improved for 43 lung cancers (31 changed to biopsy versus 12 changed away from biopsy; P = .003) and was also improved for 27 benign lesions (10 changed to biopsy versus 17 changed away from biopsy; P = .18). Most of the cancers with improved recommendations were solid lesions or mixed GGO and relatively large. CONCLUSION: CAD has the potential to improve the appropriateness of radiologists' recommendations for small malignant and benign lesions on CT scans.

Aged↗

Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN).

When lung nodules overlap with ribs or clavicles in chest radiographs, it can be difficult for radiologists as well as computer-aided diagnostic (CAD) schemes to detect these nodules. In this paper, we developed an image-processing technique for suppressing the contrast of ribs and clavicles in chest radiographs by means of a multiresolution massive training artificial neural network (MTANN). An MTANN is a highly nonlinear filter that can be trained by use of input chest radiographs and the corresponding "teaching" images. We employed "bone" images obtained by use of a dual-energy subtraction technique as the teaching images. For effective suppression of ribs having various spatial frequencies, we developed a multiresolution MTANN consisting of multiresolution decomposition/composition techniques and three MTANNs for three different-resolution images. After training with input chest radiographs and the corresponding dual-energy bone images, the multiresolution MTANN was able to provide "bone-image-like" images which were similar to the teaching bone images. By subtracting the bone-image-like images from the corresponding chest radiographs, we were able to produce "soft-tissue-image-like" images where ribs and clavicles were substantially suppressed. We used a validation test database consisting of 118 chest radiographs with pulmonary nodules and an independent test database consisting of 136 digitized screen-film chest radiographs with 136 solitary pulmonary nodules collected from 14 medical institutions in this study. When our technique was applied to nontraining chest radiographs, ribs and clavicles in the chest radiographs were suppressed substantially, while the visibility of nodules and lung vessels was maintained. Thus, our image-processing technique for rib suppression by means of a multiresolution MTANN would be potentially useful for radiologists as well as for CAD schemes in detection of lung nodules on chest radiographs.

Algorithms↗

Temporal subtraction of dual-energy chest radiographs.

Temporal subtraction and dual-energy imaging are two enhanced radiography techniques that are receiving increased attention in chest radiography. Temporal subtraction is an image processing technique that facilitates the visualization of pathologic change across serial chest radiographic images acquired from the same patient; dual-energy imaging exploits the differential relative attenuation of x-ray photons exhibited by soft-tissue and bony structures at different x-ray energies to generate a pair of images that accentuate those structures. Although temporal subtraction images provide a powerful mechanism for enhancing visualization of subtle change, misregistration artifacts in these images can mimic or obscure abnormalities. The purpose of this study was to evaluate whether dual-energy imaging could improve the quality of temporal subtraction images. Temporal subtraction images were generated from 100 pairs of temporally sequential standard radiographic chest images and from the corresponding 100 pairs of dual-energy, soft-tissue radiographic images. The registration accuracy demonstrated in the resulting temporal subtraction images was evaluated subjectively by two radiologists. The registration accuracy of the soft-tissue-based temporal subtraction images was rated superior to that of the conventional temporal subtraction images. Registration accuracy also was evaluated objectively through an automated method, which achieved an area-under-the-ROC-curve value of 0.92 in the distinction between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. By combining dual-energy soft-tissue images with temporal subtraction, misregistration artifacts can be reduced and superior image quality can be obtained.

Automation↗

Temporal subtraction in chest radiography: automated assessment of registration accuracy.

Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a "temporal subtraction image." Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from "5-excellent" to "1-poor;" ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a "lung mask" region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A(z) value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A(z) value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest radiography.

Algorithms↗

Variability in mesothelioma tumor response classification.

OBJECTIVE: The objective of our study was to evaluate observer variability in the measurement of temporal change in mesothelioma tumor thickness and in the resulting tumor response classification from CT scans. In addition, the performance of a semiautomated measurement method was evaluated. MATERIALS AND METHODS: Four observers individually used an interface that displayed two serial CT scans from the same patient to measure mesothelioma tumor thickness on the follow-up CT scans of 22 patients based on baseline scan measurements. During one session, observers acquired measurements on the follow-up scans based on written reports of baseline scan measurements; in another session, baseline scan measurements were superimposed on the baseline scan for direct visual comparison. Follow-up scan measurements also were obtained from a semiautomated method. Measurement variability and tumor response classification concordance were evaluated for manual measurements acquired in both modes and for semiautomated measurements. RESULTS: Although only a small increase in tumor response classification concordance rate was obtained with the visual approach (84.8%) relative to the more standard written-report approach (82.6%), the actual measurements acquired by observers were statistically significantly different between the two approaches (p = 0.03). Both the semiautomated measurements and the resulting tumor response classifications were consistent with manual measurements. CONCLUSION: The presentation of baseline scan tumor measurements affects measurements acquired on follow-up scans and could influence tumor response classification. The potential utility of semiautomated tumor thickness measurements was shown in the context of measuring tumor response.

Adult↗

False-positive reduction in computer-aided diagnostic scheme for detecting nodules in chest radiographs by means of massive training artificial neural network.

RATIONALE AND OBJECTIVE: We developed a technique that uses a multiple massive-training artificial neural network (multi-MTANN) to reduce the number of false-positive results in a computer-aided diagnostic (CAD) scheme for detecting nodules in chest radiographs. MATERIALS AND METHODS: Our database consisted of 91 solitary pulmonary nodules, including 64 malignant nodules and 27 benign nodules, in 91 chest radiographs. With our current CAD scheme based on a difference-image technique and linear discriminant analysis, we achieved a sensitivity of 82.4%, with 4.5 false positives per image. We developed the multi-MTANN for further reduction of the false positive rate. An MTANN is a highly nonlinear filter that can be trained with input images and corresponding teaching images. To reduce the effects of background levels in chest radiographs, we applied a background-trend-correction technique, followed by contrast normalization, to the input images for the MTANN. For enhancement of nodules, the teaching image was designed to contain the distribution for a "likelihood of being a nodule." Six MTANNs in the multi-MTANN were trained by using typical nodules and six different types of non-nodules (false positives). RESULTS: Use of the trained multi-MTANN eliminated 68.3% of false-positive findings with a reduction of one true-positive result. The false-positive rate of our original CAD scheme was improved from 4.5 to 1.4 false positives per image, at an overall sensitivity of 81.3%. CONCLUSION: Use of a multi-MTANN substantially reduced the false-positive rate of our CAD scheme for lung nodule detection on chest radiographs, while maintaining a level of sensitivity.

False Positive Reactions↗

Evaluation of semiautomated measurements of mesothelioma tumor thickness on CT scans.

RATIONALE AND OBJECTIVES: To evaluate the clinical acceptability of semiautomated methods for the measurement of mesothelioma tumor thickness in computed tomography (CT) scans. MATERIALS AND METHODS: A computer interface was developed to allow the acquisition of semiautomated mesothelioma tumor thickness measurements, which require the manual selection of a point along the outer margin of the tumor in a CT section. After application of an automated lung segmentation method, the computer automatically identifies a corresponding point along the inner margin of the tumor (as represented by the lung boundary), constructs a line segment between the manually selected outer tumor margin point and the computer-determined inner tumor margin point, and computes tumor thickness as the length of this line segment. Three radiologists and oncologists independently reviewed line segments representing the semiautomated measurements generated by three different algorithms at 134 measurement sites in the CT scans of 22 mesothelioma patients. The observers either accepted a measurement line segment or modified it through the interface. Differences between the initial semiautomated measurements and the measurements as modified by the observers were analyzed. RESULTS: The frequency with which observers accepted the semiautomated measurements without modification was as high as 86%. Of all measurements across all observers and methods (1,206 measurements), 89% were changed by 2 mm or less. CONCLUSION: We have developed semiautomated methods to measure mesothelioma tumor thickness. The potential of these methods has been demonstrated through an observer study. We expect these methods to become important tools for the efficient quantification of tumor extent.

Adult↗

Computer-aided diagnosis in thoracic CT.

Computer-aided diagnosis (CAD) provides a computerized diagnostic result as a "second opinion" to assist radiologists in the diagnosis of various diseases by use of medical images. CAD has become a practical clinical approach in diagnostic radiology, although, at present, primarily in the area of detection of breast cancer in mammograms. Currently, a large research effort has been devoted to the detection and classification of various lung diseases in thoracic computed tomography (CT) images. We describe in this article the current status of the development of CAD schemes in thoracic CT, including nodule detection, distinction between benign and malignant nodules, and detection, characterization, and differential diagnosis of diffuse lung disease. Observer performance studies indicate that these CAD schemes would be useful in clinical practice by providing radiologists with computer output as a "second opinion."

Humans↗

Computer-aided detection of peripheral lung cancers missed at CT: ROC analyses without and with localization.

PURPOSE: To retrospectively evaluate whether a difference-image computer-aided detection (CAD) scheme can help radiologists detect peripheral lung cancers missed at low-dose computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed patient and observer consent were obtained. Seventeen patients (eight men and nine women; mean age, 60 years) with a missed peripheral lung cancer and 10 control subjects (five men and five women; mean age, 63 years) without cancer at low-dose CT were included in an observer study. Fourteen radiologists were divided into two groups on the basis of different image display formats: Six radiologists (group 1) reviewed CT scans with a multiformat display, and eight radiologists (group 2) reviewed images with a "stacked" cine-mode display. The radiologists, first without and then with the CAD scheme, indicated their confidence level regarding the presence (or absence) of cancer and the most likely position of a lesion on each CT scan. Receiver operating characteristic (ROC) curves were calculated without and with localization to evaluate the observers' performance. RESULTS: With the CAD scheme, the average area under the ROC curve improved from 0.763 to 0.854 for all radiologists (P = .002), from 0.757 to 0.862 for group 1 (P = .04), and from 0.768 to 0.848 for group 2 (P = .01). The average sensitivity in the detection of 17 cancers improved from 52% (124 of 238 observations) to 68% (163 of 238 observations) for all radiologists (P < .001), from 49% (50 of 102 observations) to 71% (72 of 102 observations) for group 1 (P = .02), and from 54% (74 of 136 observations) to 67% (91 of 136 observations) for group 2 (P = .006). The localization ROC curve also improved. CONCLUSION: Lung cancers missed at low-dose CT were very difficult to detect, even in an observer study. The use of CAD, however, can improve radiologists' performance in the detection of these subtle cancers.

Aged↗

Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society.

Lung nodules are detected very commonly on computed tomographic (CT) scans of the chest, and the ability to detect very small nodules improves with each new generation of CT scanner. In reported studies, up to 51% of smokers aged 50 years or older have pulmonary nodules on CT scans. However, the existing guidelines for follow-up and management of noncalcified nodules detected on nonscreening CT scans were developed before widespread use of multi-detector row CT and still indicate that every indeterminate nodule should be followed with serial CT for a minimum of 2 years. This policy, which requires large numbers of studies to be performed at considerable expense and with substantial radiation exposure for the affected population, has not proved to be beneficial or cost-effective. During the past 5 years, new information regarding prevalence, biologic characteristics, and growth rates of small lung cancers has become available; thus, the authors believe that the time-honored requirement to follow every small indeterminate nodule with serial CT should be revised. In this statement, which has been approved by the Fleischner Society, the pertinent data are reviewed, the authors' conclusions are summarized, and new guidelines are proposed for follow-up and management of small pulmonary nodules detected on CT scans.

Diagnosis, Differential↗

Artificial neural networks (ANNs) for differential diagnosis of interstitial lung disease: results of a simulation test with actual clinical cases.

RATIONALE AND OBJECTIVES: To evaluate the performance of an artificial neural network (ANN) scheme with use of consecutive clinical cases and its effect on radiologists with an observer test. MATERIALS AND METHODS: Artificial neural networks were designed to distinguish among 11 interstitial lung diseases on the basis of 26 inputs (16 radiologic findings, 10 clinical parameters). Chest radiographs of 96 consecutive cases with interstitial lung disease were used. Five radiologists independently rated their radiologic findings on the 96 chest radiographs. Based on their ratings of radiologic findings and clinical parameters obtained from the hospital information system, the output values indicating the likelihood of each of the 11 interstitial lung diseases were determined. Subsequently, 30 cases were selected from these 96 cases for an observer test. Five radiologists marked their confidence levels for diagnosis of 11 possible diseases in each case without and with ANN output. The performance of ANNs and radiologists was evaluated by receiver operating characteristic analysis based on their outputs and on confidence levels, respectively. RESULTS; The average Az value (area under the receiver operating characteristic curve) indicating ANN performance for the 96 consecutive cases was 0.85 +/- 0.03. The average Az values indicating radiologists' performance without and with ANN outputs were 0.81 +/- 0.11 and 0.87 +/- 0.06, respectively. The diagnostic accuracy was improved significantly when radiologists read chest radiographs with ANN outputs (P < .05). CONCLUSION: Artificial neural networks for differential diagnosis of interstitial lung disease may be useful in clinical situations, and radiologists may be able to utilize the ANN output to their advantage in the differential diagnosis of interstitial lung disease on chest radiographs.

Adult↗

Measurement of mesothelioma on thoracic CT scans: a comparison of manual and computer-assisted techniques.

Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r > or = 0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r > or = 0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers.

Adult↗

Lung image database consortium: developing a resource for the medical imaging research community.

To stimulate the advancement of computer-aided diagnostic (CAD) research for lung nodules in thoracic computed tomography (CT), the National Cancer Institute launched a cooperative effort known as the Lung Image Database Consortium (LIDC). The LIDC is composed of five academic institutions from across the United States that are working together to develop an image database that will serve as an international research resource for the development, training, and evaluation of CAD methods in the detection of lung nodules on CT scans. Prior to the collection of CT images and associated patient data, the LIDC has been engaged in a consensus process to identify, address, and resolve a host of challenging technical and clinical issues to provide a solid foundation for a scientifically robust database. These issues include the establishment of (a) a governing mission statement, (b) criteria to determine whether a CT scan is eligible for inclusion in the database, (c) an appropriate definition of the term qualifying nodule, (d) an appropriate definition of "truth" requirements, (e) a process model through which the database will be populated, and (f) a statistical framework to guide the application of assessment methods by users of the database. Through a consensus process in which careful planning and proper consideration of fundamental issues have been emphasized, the LIDC database is expected to provide a powerful resource for the medical imaging research community. This article is intended to share with the community the breadth and depth of these key issues.

Biomedical Research↗

Low-dose computed tomography screening for lung cancer in a general population: characteristics of cancer in non-smokers versus smokers.

RATIONALE AND OBJECTIVES: To report the detection rate for lung cancers in computed tomography (CT) screening in Japanese adults, and to analyze differences in the appearance of the cancers in non-smokers versus smokers. MATERIALS AND METHODS: Subjects consisted of 7,847 Japanese adults who received low-dose CT screening at least once in a 3-year period. The detection rate of lung cancers and the correlation of imaging, clinical, and pathologic findings of cancers in non-smokers versus smokers were examined. RESULTS: The detection rate for lung cancer was 1.1% for both non-smokers (45 of 4,251) and smokers (39 of 3,596). The prevalence of well-differentiated adenocarcinomas was greater in non-smokers (88%; 22 of 25) than in smokers (29%; 4 of 14) (P < .001). The prevalence and incidence of pathologic stage IA disease were greater in non-smokers than in smokers (92%; [22 of 24] vs 58% [7 of 12], and 100% [19 of 19] vs 70% [14 of 20]) (both P < .05). The mean size of the tumors in the non-smokers (12.4 mm) was smaller than that in smokers (18.2 mm) (P < .001). The percentage of cancers categorized as pure or mixed ground-glass opacity (86%; 38 of 44) on CT was greater in non-smokers than in smokers (46%; 16 of 35) (P < .001). CONCLUSION: Most of the lung cancers in non-smokers were slow-growing adenocarcinomas appearing as faint ground-glass opacities on CT, whereas rapidly growing cancers appearing as solid nodules were more commonly seen in smokers.

Adenocarcinoma↗

Computer-aided diagnosis to distinguish benign from malignant solitary pulmonary nodules on radiographs: ROC analysis of radiologists' performance--initial experience.

PURPOSE: To evaluate radiologists' performance for determining a distinction between benign and malignant pulmonary nodules on chest radiographs without and with use of a computer-aided diagnosis scheme. MATERIALS AND METHODS: Fifty-three chest radiographs that depicted 31 primary lung cancers and 22 benign nodules were used. The likelihood measure of malignancy for each nodule was determined by using an automated computerized scheme. Sixteen radiologists (nine attending radiologists and seven radiology residents) participated in an observer study in which cases were interpreted first without and then with use of the scheme. The radiologists' performance was evaluated with receiver operating characteristic analysis. RESULTS: The mean area under the best-fit binormal receiver operating characteristic curve plotted in the unit square (Az) values of radiologists who interpreted images without and with the scheme were 0.743 and 0.817, respectively. The performance of radiologists was improved significantly when the scheme was used (P =.002). However, the performance (Az = 0.889) of the computer alone exceeded these results by a substantial margin. The average change in radiologists' confidence level for interpretation without and with the scheme was highly correlated (r = 0.845) with the likelihood measure of malignancy, which was presented as computer output. CONCLUSION: This scheme for computer-aided diagnosis has the potential to improve the accuracy of radiologists' performance in the classification of benign and malignant solitary pulmonary nodules.

Diagnosis, Computer-Assisted↗

Use of an artificial neural network to determine the diagnostic value of specific clinical and radiologic parameters in the diagnosis of interstitial lung disease on chest radiographs.

RATIONALE AND OBJECTIVES: The authors investigated the diagnostic value of each of multiple clinical parameters and radiologic findings in differentiating between various interstitial lung diseases by using an artificial neural network (ANN). MATERIALS AND METHODS: The ANN was designed to differentiate between 11 interstitial lung diseases. The authors employed 10 clinical parameters and 16 radiologic findings that were divided into three groups (location, general appearance, specific findings). The performance of the ANN was evaluated with receiver operating characteristic analysis with amodified round-robin (leave-one-out) method and 370 cases (150 actual cases, 110 published cases, and 110 hypothetical cases). The Az values of ANNs were evaluated with various combinations of 10 clinical parameters and 16 radiologic findings. RESULTS: The Az value obtained with the complete set of clinical parameters and radiologic findings was 0.947. The Az value obtained with the 10 clinical parameters alone was 0.900, which was greater than 0.843 obtained with the 16 radiologic findings alone. There were statistically significant differences among Az values for some diseases when certain clinical parameters were removed from the input. Omission of specific findings among the three groups of radiologic findings decreased the Az value significantly. CONCLUSION: These results appear to confirm that clinical parameters can be equally as or more important than radiologic findings in the diagnosis of interstitial lung diseases. Among radiologic findings, certain specific findings can be more important than the location or general appearance of abnormal findings.

Humans↗