Prostate boundary segmentation from ultrasound images using 2D active shape models: optimisation and extension to 3D.

Boundary outlining, or segmentation, of the prostate is an important task in diagnosis and treatment planning for prostate cancer. This paper describes an algorithm based on two-dimensional (2D) active shape models (ASM) for semi-automatic segmentation of the prostate boundary from ultrasound images. Optimisation of the 2D ASM for prostatic ultrasound was done first by examining ASM construction and image search parameters. Extension of the algorithm to three-dimensional (3D) segmentation was then done using rotational-based slicing. Evaluation of the 3D segmentation algorithm used distance- and volume-based error metrics to compare algorithm generated boundary outlines to gold standard (manually generated) boundary outlines. Minimum description length landmark placement for ASM construction, and specific values for constraints and image search were found to be optimal. Evaluation of the algorithm versus gold standard boundaries found an average mean absolute distance of 1.09+/-0.49 mm, an average percent absolute volume difference of 3.28+/-3.16%, and a 5x speed increase versus manual segmentation.

Algorithms↗

A geometrically nonlinear finite-element model of the cat eardrum.

Current finite-element (FE) models of the eardrum are limited to low pressures because of the assumption of linearity. Our objective is to investigate the effects of geometric nonlinearity in FE models of the cat eardrum with an approximately immobile malleus for pressures up to +/-2.2 kPa, which are within the range of pressures used in clinical tympanometry. Displacements computed with nonlinear models increased less than in proportion to applied pressure, similar to what is seen in measured data. In both simulations and experiments, there is a shift inferiorly in the location of maximum displacement in response to increasingly negative middle-ear pressures. Displacement patterns computed for small pressures and for large positive pressures differed from measured patterns in the position of the maximum pars-tensa displacement. Increasing the thickness of the postero-superior pars tensa in the models shifted the location of the computed maximum toward the measured location. The largest computed pars-tensa strains were mostly less than 2%, implying that a linearized material model is a reasonable approximation. Geometric nonlinearity must be considered when simulating eardrum response to high pressures because purely linear models cannot take into account the effects of changing geometry. At higher pressures, material nonlinearity may become more important.

Acoustic Stimulation↗

Carotid distensibility, baroreflex sensitivity, and orthostatic stress.

In this study, we tested the hypothesis that carotid arteries undergo rapid changes in distensibility on moving from the supine to head-up tilt (HUT) postures and, subsequently, that this change in carotid distensibility (cDa) might be associated with concurrent reductions in cardiovagal baroreflex sensitivity (BRS). Thus the effect of posture on carotid vascular mechanics and cardiovagal BRS with consideration for altered central hemodynamics (i.e., stroke volume; Doppler ultrasound) was examined. Carotid pulse pressure (cPP; Millar transducer) and contralateral B-mode ultrasound images were assessed at the carotid artery during supine and 60 degrees HUT postures. From these measures, cDa was calculated at 5-mmHg pressure increments experienced during the cardiac cycle (n = 6). cPP (n = 9) was not different in the two postures. A smaller stroke volume being ejected into a smaller carotid artery in HUT explained the maintenance of cPP in HUT. Also, compared with supine, cDa was reset to a lower level in HUT (main effect of posture; P < 0.05). Cardiovagal BRS (sequence method) was diminished in HUT vs. supine (P < 0.05). A positive correlation was observed between the tilt-induced changes in maximal cDa (in early systole) and cardiovagal BRS (r2 = 0.75; P < 0.05), but there was little predictive relationship between changes in cPP, systolic vessel dimensions, or average cDa and the corresponding change in BRS. The present results indicate that HUT elicits rapid changes in carotid artery mechanics and further suggest that reductions in the maximal cDa measured in early systole contribute to reduced cardiovagal BRS with HUT.

Adult↗

Template-based finite-element mesh generation from medical images.

The finite-element (FE) method is commonly used in biomedical engineering to simulate the behaviour of biological structures because of its ability to model complex shapes in a subject-specific manner. However, generating FE meshes from medical images remains a bottleneck. We present a template-based technique for semi-automatically generating FE meshes which is applicable to prospective studies of individual patients in which FE meshes must be generated from scans of the same structure taken at different points in time to study the effects of disease progression/regression. In this "template-based" meshing approach, the baseline FE (tetrahedral) volume mesh is first manually aligned with the follow-up images. The triangulated surface of the mesh is then automatically deformed to fit the imaged organ boundary. The deformed surface nodes are then smoothed using a Laplacian smoothing algorithm to correct triangle (surface nodes) distortion and thus preserve triangle quality. Finally, the internal mesh nodes are smoothed to correct distorted tetrahedral elements and thus preserve tetrahedral element quality. This template-based approach is shown to be as accurate and precise as the previous technique used by our group, while preserving element quality and volume.

Algorithms↗

Software for interactive segmentation of the carotid artery from 3D black blood magnetic resonance images.

A semiautomatic algorithm for segmenting organ surfaces from 3D medical images is presented in this work. The algorithm is based on a deformable model, and allows the user to initialize the model by combining and molding primitive shapes such as cylinders and spheres to form an initial approximate model of the organ surface. The initial model is automatically deformed to better fit organ boundaries. The algorithm was applied to segment the carotid bifurcation from 3D black blood magnetic resonance (MR) images of 5 subjects. The algorithm-segmented surfaces were compared to surfaces segmented manually by an experienced user. On average, approximately 3 min were required to segment an image using the algorithm, whereas 1h was required for manual segmentation. The average distance between corresponding points on the manually and algorithm-segmented surfaces was 0.37 mm, whereas the average maximum distance was 2.03 mm. Moreover, algorithm-segmented surfaces exhibited less intra-operator variability than those segmented manually.

Algorithms↗

Response of the cat eardrum to static pressures: mobile versus immobile malleus.

A phase-shift shadow moiré interferometer was used to measure the shape of the cat eardrum with a normal mobile malleus and with an immobile malleus as it was cyclically loaded with static middle-ear pressures up to +/-2.2 kPa. The shape was monitored throughout the loading and unloading phases, and three complete cycles were observed. The mobile-manubrium measurements were made in five ears. In three ears, the malleus was then immobilized with a drop of glue placed on the head of the malleus. Eardrum displacements were calculated by subtracting shape images pixel by pixel. The measurements are presented in the form of gray-level full-field shape and displacement images, of displacement profiles, and of pressure-displacement curves for selected points. Displacement patterns with a mobile malleus show that pars-tensa displacements are larger than manubrial displacements, with the maximum pars-tensa displacement occurring in the posterior region in all cats except one. Displacements vary from cycle to cycle and display hysteresis. For both the mobile-malleus and immobile-malleus cases, the eardrum response is nonlinear. The response is asymmetric, with lateral displacements being larger than medial displacements. With a mobile malleus, manubrial displacements exhibit more pronounced asymmetry than do pars-tensa displacements.

Algorithms↗

A new method for assessing arteriolar diameter and hemodynamic resistance using image analysis of vessel lumen.

To characterize the nonuniform diameter response in a blood vessel after a given stimulus (e.g., arteriolar conducted response), frequent serial diameter measurements along the vessel length are required. We used an advanced image analysis algorithm (the "discrete dynamic contour") to develop a quick, reliable method for serial luminal diameter measurements along the arteriole visualized by intravital video microscopy. With the use of digitized images of the arteriole and computer graphics, the method required an operator to mark the image of the two inner edges of the arteriole at several places along the arteriolar length. The algorithm then "filled in" these marks to generate two continuous contours that "hugged" these edges. A computer routine used these contours to determine luminal diameters every 20 microm. Based on these diameters and on Poiseuille's law, the routine also estimated the hemodynamic resistance of the blood vessel. To demonstrate the usefulness of the method, we examined the character of spatial decay of KCl-induced conducted constriction along approximately 500-microm-long arteriolar segments and the KCl-induced increase in hemodynamic resistance computed for these segments. The decay was only modestly fitted by a simple exponential, and the computed increase in resistance (i.e., 5- to 70-fold) was only modestly predicted by resistance increase based on our mathematical model involving measurements at two arteriolar sites (Tyml K, Wang X, Lidington D, and Oullette Y. Am J Physiol Heart Circ Physiol 281: H1397-H1406, 2001). We conclude that our method provides quick, reliable serial diameter measurements. Because the change in hemodynamic resistance could serve as a sensitive index of conducted response, use of this index in studies of conducted response may lead to new mechanistic insights on the response.

Animals↗

Testing and optimization of a semiautomatic prostate boundary segmentation algorithm using virtual operators.

Image analysis tasks such as size measurement and landmark-based registration require the user to select control points in an image. The output of such algorithms depends on the choice of control points. Since the choice of points varies from one user to the next, the requirement for user input introduces variability into the output of the algorithm. In order to test and/or optimize such algorithms, it is necessary to assess the multiplicity of outputs generated by the algorithm in response to a large set of inputs; however, the input of data requires substantial time and effort from multiple users. In this paper we describe a method to automate the testing and optimization of algorithms using "virtual operators," which consist of a set of spatial distributions describing how actual users select control points in an image. In order to construct the virtual operator, multiple users must repeatedly select control points in the image on which testing is to be performed. Once virtual operators are generated, control points for initializing the algorithm can be generated from them using a random number generator. Although an initial investment of time is required from the users in order to construct the virtual operator, testing and optimization of the algorithm can be done without further user interaction. We illustrate the construction and use of virtual operators by testing and optimizing our prostate boundary segmentation algorithm. The algorithm requires the user to select four control points on the prostate as input.

Algorithms↗

Prostate boundary segmentation from 3D ultrasound images.

Segmenting, or outlining the prostate boundary is an important task in the management of patients with prostate cancer. In this paper, an algorithm is described for semiautomatic segmentation of the prostate from 3D ultrasound images. The algorithm uses model-based initialization and mesh refinement using an efficient deformable model. Initialization requires the user to select only six points from which the outline of the prostate is estimated using shape information. The estimated outline is then automatically deformed to better fit the prostate boundary. An editing tool allows the user to edit the boundary in problematic regions and then deform the model again to improve the final results. The algorithm requires less than 1 min on a Pentium III 400 MHz PC. The accuracy of the algorithm was assessed by comparing the algorithm results, obtained from both local and global analysis, to the manual segmentations on six prostates. The local difference was mapped on the surface of the algorithm boundary to produce a visual representation. Global error analysis showed that the average difference between manual and algorithm boundaries was -0.20 +/- 0.28 mm, the average absolute difference was 1.19 +/- 0.14 mm, the average maximum difference was 7.01 +/- 1.04 mm, and the average volume difference was 7.16% +/- 3.45%. Variability in manual and algorithm segmentation was also assessed: Visual representations of local variability were generated by mapping variability on the segmentation mesh. The mean variability in manual segmentation was 0.98 mm and in algorithm segmentation was 0.63 mm and the differences of about 51.5% of the points comprising the average algorithm boundary are insignificant (P < or = 0.01) to the manual average boundary.

Algorithms↗

Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI.

A thorough understanding of the relationship between local hemodynamics and plaque progression has been hindered by an inability to prospectively monitor these factors in vivo in humans. In this study a novel approach for noninvasively reconstructing artery wall thickness and local hemodynamics at the human carotid bifurcation is presented. Three-dimensional (3D) models of the lumen and wall boundaries, from which wall thickness can be measured, were reconstructed from black-blood magnetic resonance imaging (MRI). Along with time-varying inlet/outlet flow rates measured via phase contrast (PC) MRI, the lumen boundary was used as input for computational fluid dynamic (CFD) simulation of the subject-specific flow patterns and wall shear stresses (WSSs). Results from a 59-year-old subject with early, asymptomatic carotid artery disease show good agreement between simulated and measured velocities, and demonstrate a correspondence between wall thickening and low and oscillating shear at the carotid bulb. High shear at the distal internal carotid artery (ICA) was also colocalized with higher WSS; however, a quantitative general relationship between WSS and wall thickness was not found. Similar results were obtained from a 23-year-old normal subject. These findings represent the first direct comparison of hemodynamic variables and wall thickness at the carotid bifurcation of human subjects. The noninvasive nature of this image-based modeling approach makes it ideal for carrying out future prospective studies of hemodynamics and plaque development or progression in otherwise healthy subjects.

Adult↗