Endoscopic, rapid near-infrared optical tomography.

This is believed to be the first demonstration of near-infrared (NIR) optical tomography employed at the endoscope scale and at a rapid sampling speed that allows translation to in vivo use. A spread-spectral-encoding technique based on a broadband light source and linear-to-circular fiber bundling was used to provide endoscopic probing of many source-detector fibers for tomography as well as parallel sampling of all source-detector pairs for rapid imaging. Endoscopic NIR tomography at an 8 Hz frame rate was achieved in phantoms and tissue specimens with a 12 mm probe housing eight sources and eight detectors. This novel approach provides the key feasibility studies to allow this blood-based contrast imaging technology to be attempted in detection of cancer in internal organs via endoscopic interrogation.

Computer Systems↗

Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomography.

Magnetic resonance (MR)-guided near-infrared spectral tomography was developed and used to image adipose and fibroglandular breast tissue of 11 normal female subjects, recruited under an institutional review board-approved protocol. Images of hemoglobin, oxygen saturation, water fraction, and subcellular scattering were reconstructed and show that fibroglandular fractions of both blood and water are higher than in adipose tissue. Variation in adipose and fibroglandular tissue composition between individuals was not significantly different across the scattered and dense breast categories. Combined MR and near-infrared tomography provides fundamental molecular information about these tissue types with resolution governed by MR T1 images.

Adipose Tissue↗

Spectrally resolved bioluminescence optical tomography.

Spectrally resolved bioluminescence optical tomography is an approach to recover images of luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminescence tomography is highlighted. Reconstructed images of bioluminescence are presented by using as input both simulated and real multiwavelength data from a tissue-simulating phantom. The location of the internal bioluminescence is obtained with 1 mm accuracy. Further, the amplitude of the reconstructed source is proportional to the actual bioluminescence intensity.

Imaging, Three-Dimensional↗

In vivo hemoglobin and water concentrations, oxygen saturation, and scattering estimates from near-infrared breast tomography using spectral reconstruction.

RATIONALE AND OBJECTIVES: Near-infrared (NIR) imaging has its niche in quantifying and characterizing functional changes in tissue relating to vascularity and metabolic status. Here, NIR tomography was applied to study mammographically normal breast tissue in vivo by evaluating relationships between functional parameters so obtained to clinical representers in an effort to understand factors influencing tissue compositional changes. MATERIALS AND METHODS: A new spectral reconstruction method that is considered to provide the most accurate estimates of hemoglobin level, oxygen saturation, water fraction, scattering power, and amplitude was used to assess healthy breast tissue imaged in vivo by means of NIR tomography. The approach directly recovers functional parameters with inherent inclusion of spectral behavior enforced through the incorporation of a priori model assumptions. Sixty subjects were imaged by using a frequency-domain instrument followed by spectral image reconstruction and statistical analysis for significant correlations. RESULTS: The new analysis shows statistically significant inverse correlations between body mass index and breast total hemoglobin and water fractions. Water fraction also correlated inversely with age and separated certain categories of breast density. Average scatter power was indicative of breast radiographic density composition, whereas scatter amplitude varied inversely with breast diameter. Total hemoglobin correlated with water fraction, whereas water correlated with scatter power. CONCLUSION: The changes observed here are attributable to volume fraction alterations and provide some of the most comprehensive data on breast composition variations with demographic factors.

Adult↗

Finite element implementation of Maxwell's equations for image reconstruction in electrical impedance tomography.

Traditionally, image reconstruction in electrical impedance tomography (EIT) has been based on Laplace's equation. However, at high frequencies the coupling between electric and magnetic fields requires solution of the full Maxwell equations. In this paper, a formulation is presented in terms of the Maxwell equations expressed in scalar and vector potentials. The approach leads to boundary conditions that naturally align with the quantities measured by EIT instrumentation. A two-dimensional implementation for image reconstruction from EIT data is realized. The effect of frequency on the field distribution is illustrated using the high-frequency model and is compared with Laplace solutions. Numerical simulations and experimental results are also presented to illustrate image reconstruction over a range of frequencies using the new implementation. The results show that scalar/vector potential reconstruction produces images which are essentially indistinguishable from a Laplace algorithm for frequencies below 1 MHz but superior at frequencies reaching 10 MHz.

Algorithms↗

Spectral derivative based image reconstruction provides inherent insensitivity to coupling and geometric errors.

A reconstruction algorithm for multiwavelength diffuse optical tomography is presented, where instead of using data at each wavelength separately or even simultaneously, the difference in data for multiple wavelength pairs is used to reconstruct absolute concentration maps of chromophores. The results indicate a dramatic improvement in image reconstruction and the elimination of image artifacts, which are often associated with unknown measurement errors such as coupling coefficients and external boundary variations, because these errors are often less dependent on wavelength, and are effectively removed from the data set of the first derivative of intensity with respect to wavelength.

Algorithms↗

Video-rate near-infrared optical tomography using spectrally encoded parallel light delivery.

A novel parallel source implementation approach to near-infrared tomography is demonstrated through spectral encoding of the light delivery. This new technique allows many sources to be input into the tissue at the same time, and a high-resolution spectrometer is used to spatially spread out the signals from each spectrally encoded source. The parallel sampling of all sources at all detection locations renders rapid imaging. Acquisition of complete tomographic data sets at a video rate of 35 frames/s is achieved for imaging of a 6.35 mm diameter inclusion with an absorption coefficient of 0.01 mm(-1) and a reduced scattering coefficient of 1.5 mm(-1) that is moving along a circular path inside a 1% Intralipid solution.

Computer Systems↗

Spectral priors improve near-infrared diffuse tomography more than spatial priors.

We compare the benefits of spatial and spectral priors in near-infrared diffuse tomography image reconstruction. Although previous studies that incorporated anatomical spatial priors have shown improvement in algorithm convergence and resolution, our results indicate that functional parameter quantification by this approach can be suboptimal. The incorporation of a priori spectral information significantly improves the accuracy observed in recovered images. Specifically, phantom results show that the maximum total hemoglobin concentration ([Hb(T)]) in a region of heterogeneity reached 91% of the true value compared to 63% using spatial priors. The combination of both priors produced results accurate to 98% of the true [Hb(T)]. When both spatial and spectral priors were applied in a healthy volunteer, glandular tissue showed a higher [Hb(T)], water fraction, and scattering power compared to adipose tissue.

Algorithms↗

Magnetic-resonance-imaging-coupled broadband near-infrared tomography system for small animal brain studies.

A novel magnetic-resonance-coupled broadband near-infrared (NIR) tomography system for small animal brain studies is described. Several features of the image formation approach are new in NIR tomography and represent major advances in the path to recovering high-resolution hemoglobin and oxygen saturation images of tissue. The NIR data were broadband and continuous wave and were used along with a second-derivative-based estimation of the path length from water absorption. The path length estimation from water was then used along with the attenuation spectrum to recover absorption and reduced scattering coefficient images at multiple wavelengths and then to recover images of total hemoglobin and oxygen saturation. Going beyond these basics of NIR tomography, software has been developed to allow inclusion of structures derived from MR imaging (MRI) for the external and internal tissue boundaries, thereby improving the accuracy and spatial resolution of the properties in each tissue type. The system has been validated in both tissue-simulating phantoms, with 10% accuracy observed, and in a rat cranium imaging experiment. The latter experiment used variation in inspired oxygen (FiO2) to vary the observed hemoglobin and oxygen saturation images. Quantitative agreement was observed between the changes in deoxyhemoglobin values derived from NIR and the changes predicted with blood-oxygen-level-dependent (BOLD) MRI. This system represents the initial stage in what will likely be a larger role for NIR tomography, coupled to MRI, and illustrates that the technological challenges of using continuous-wave broadband data and inclusion of a priori structural information can be met with careful phantom studies.

Algorithms↗

Spectrally constrained chromophore and scattering near-infrared tomography provides quantitative and robust reconstruction.

A multispectral direct chromophore and scattering reconstruction technique has been implemented for near-infrared frequency-domain tomography in recovering images of total hemoglobin, oxygen saturation, water, and scatter parameters. The method applies the spectral constraint of the chromophores and scattering spectra directly in the reconstruction algorithm, thereby reducing the parameter space of the inversion process. This new method was validated by use of simulated and experimental data, and results show better robustness and stability in the presence of higher levels of noise. The method suppresses artifacts, especially those significant in water and scatter power images, and reduces cross talk between chromophore and scatter parameters. Variation in scattering was followed by this spectral approach successfully in experimental data from 90-mm-diameter cylindrical phantoms, and results show linear variation in scatter amplitude and reduced scattering coefficient (micro(s)'), with total hemoglobin, oxygen saturation, and water remaining constant and quantitatively accurate. Similar experiments were carried out for varying oxygen saturation and total hemoglobin. Accurate quantification was obtained with a mean error of 7.7% for oxygen saturation and 6.2% for total hemoglobin, with minimal cross talk between different parameters.

Algorithms↗

Effects of refractive index on near-infrared tomography of the breast.

Near infrared (NIR) optical tomography is an imaging technique in which internal images of optical properties are reconstructed with the boundary measurements of light propagation through the medium. Recent advances in instrumentation and theory have led to the use of this method for the detection and characterization of tumors within the female breast tissue. Most image reconstruction approaches have used the diffusion approximation and have assumed that the refractive index of the breast is constant, with a bulk value of approximately 1.4. We have applied a previously reported modified diffusion approximation, in which the refractive index for different tissues can be modeled. The model was used to generate NIR data from a realistic breast geometry containing a localized anomaly. Using this simulated data, we have reconstructed optical images, both with and without correct knowledge of the refractive-index distribution to show that the modified diffusion approximation can accurately recover the anomaly given a priori knowledge of refractive index. But using a reconstruction algorithm without the use of correct a priori information regarding the refractive-index distribution is shown as recovering the anomaly but with a degraded quality, depending on the degree of refractive index mismatch. The results suggest that provided the refractive index of breast tissue is approximately 1.3-1.4, their exclusion will have minimal effect on the reconstructed images.

Algorithms↗

Excitation patterns in three-dimensional electrical impedance tomography.

Electrical impedance tomography (EIT) is a non-invasive technique that aims to reconstruct images of internal electrical properties of a domain, based on electrical measurements on the periphery. Improvements in instrumentation and numerical modeling have led to three-dimensional (3D) imaging. The availability of 3D modeling and imaging raises the question of identifying the best possible excitation patterns that will yield to data, which can be used to produce the best image reconstruction of internal properties. In this work, we describe our 3D finite element model of EIT. Through singular value decomposition as well as examples of reconstructed images, we show that for a homogenous female breast model with four layers of electrodes, a driving pattern where each excitation plane is a sinusoidal pattern out-of-phase with its neighboring plane produces better qualitative images. However, in terms of quantitative imaging an excitation pattern where all electrode layers are in phase produces better results.

Algorithms↗

Near-infrared characterization of breast tumors in vivo using spectrally-constrained reconstruction.

Multi-wavelength Near-Infrared (NIR) Tomography was utilized in this study to non-invasively quantify physiological parameters of breast tumors using direct spectral reconstruction. Frequency domain NIR measurements were incorporated with a new spectrally constrained direct chromophore and scattering image reconstruction algorithm, which was validated in simulations and experimental phantoms. Images of total hemoglobin, oxygen saturation, water, and scatter parameters were obtained with higher accuracy than previously reported. Using this spectral approach, in vivo NIR images are presented and interpreted through a series of case studies (n=6 subjects) having differing abnormalities. The corresponding mammograms and ultrasound images are also evaluated. Three of six cases were malignant (infiltrating ductal carcinomas) and showed higher hemoglobin (34-86% increase), a reduction in oxygen saturation, an increase in water content as well as scatter changes relative to surrounding normal tissue. Three of six cases were benign, two of which were diagnosed with fibrocystic disease and showed a dominant contrast in water, consistent with fluid filled cysts. Scatter amplitude was the main source of contrast in the volunteer with the benign condition fibrosis, which typically contains denser collagen tissue. The changes monitored correspond to physiological changes associated with angiogenesis, hypoxia and cell proliferation anticipated in cancers. These changes represent potential diagnostic indicators, which can be assessed to characterize breast tumors.

Adult↗

Absorption and scattering imaging of tissue with steady-state second-differential spectral-analysis tomography.

A novel approach to reconstructing both the absorption and the scattering properties of a turbid medium simultaneously from steady-state broadband spectral measurements is presented that utilizes second-differential fitting to the water spectrum to estimate the optical path length in tissue. Theoretical and experimental evidence is provided to demonstrate the robust accuracy of the spectroscopy approach and reconstructed absorption images. The steady-state broadband CCD system has the potential to provide accurate chromophore imaging without the technological complexity of time- or frequency-domain systems.

Absorption↗

Breast deformation modelling for image reconstruction in near infrared optical tomography.

Near infrared tomography (NIR) is a novel imaging technique that can be used to reconstruct tissue optical properties from measurements of light propagation through tissue. More specifically NIR measurements over a range of wavelengths can be used to obtain internal images of physiologic parameters and these images can be used to detect and characterize breast tumour. To obtain good NIR measurements, it is essential to have good contact between the optical fibres and the breast which in-turn results in the deformation of the breast due to the soft plasticity of the tissue. In this work, a tissue deformation model of the female breast is presented that will account for the altered shape of the breast during clinical NIR measurements. Using a deformed model of a breast, simulated NIR data were generated and used to reconstruct images of tissue absorption and reduced scatter using several assumptions about the imaging domain. Using either a circular or irregular 2D geometry for image reconstruction produces good localization of the absorbing anomaly, but it leads to degradation of the image quality. By modifying the assumptions about the imaging domain to a 3D conical model, with the correct diameter at the plane of NIR measurement, significantly improves the quality of reconstructed images and helps reduce image artefacts. Finally, assuming a non-deformed breast shape for image reconstruction is shown to lead to poor quality images since the geometry of the breast is greatly altered, whereas using the correct deformed geometry produces the best images.

Algorithms↗

Automated region detection based on the contrast-to-noise ratio in near-infrared tomography.

The contrast-to-noise ratio (CNR) was used to determine the detectability of objects within reconstructed images from diffuse near-infrared tomography. It was concluded that there was a maximal value of CNR near the location of an object within the image and that the size of the true region could be estimated from the CNR. Experimental and simulation studies led to the conclusion that objects can be automatically detected with CNR analysis and that our current system has a spatial resolution limit near 4 mm and a contrast resolution limit near 1.4. A new linear convolution method of CNR calculation was developed for automated region of interest (ROI) detection.

Artifacts↗

Interpreting hemoglobin and water concentration, oxygen saturation, and scattering measured in vivo by near-infrared breast tomography.

Near-infrared spectroscopic tomography was used to measure the properties of 24 mammographically normal breasts to quantify whole-breast absorption and scattering spectra and to evaluate which tissue composition characteristics can be determined from these spectra. The absorption spectrum of breast tissue allows quantification of (i) total hemoglobin concentration, (ii) hemoglobin oxygen saturation, and (iii) water concentration, whereas the scattering spectrum provides information about the size and number density of cellular components and structural matrix elements. These property data were tested for correlation to demographic information, including subject age, body mass index, breast size, and radiographic density. Total hemoglobin concentration correlated inversely to body mass index, likely because lower body mass indicates proportionately less fat and more glandular tissue, and glandular tissue contains greater vascularity, hence, more total hemoglobin. Optical scattering was correlated to breast diameter, subject age, and radiographic density. In the radiographic density, fatty breasts had low scattering power and extremely dense breasts had higher values. This observation is consistent with low attenuation of conventional x-rays with fat and higher attenuation in glandular tissues. Optically, fatty tissues have large scatterers leading to a low scattering power, whereas glandular or fibrous tissues have more cellular and collagen-based structures that lead to high scattering power. The study presents correlative data supporting the hypothesis that optical measurements of absorption and scattering can provide physiologically relevant information about breast tissue composition. These breast constituents vary significantly between individuals and can be altered because of changes in breast physiology or pathological state.

Adult↗

The effects of internal refractive index variation in near-infrared optical tomography: a finite element modelling approach.

Near-infrared (NIR) tomography is a technique used to measure light propagation through tissue and generate images of internal optical property distributions from boundary measurements. Most popular applications have concentrated on female breast imaging, neonatal and adult head imaging, as well as muscle and small animal studies. In most instances a highly scattering medium with a homogeneous refractive index is assumed throughout the imaging domain. Using these assumptions, it is possible to simplify the model to the diffusion approximation. However, biological tissue contains regions of varying optical absorption and scatter, as well as varying refractive index. In this work, we introduce an internal boundary constraint in the finite element method approach to modelling light propagation through tissue that accounts for regions of different refractive indices. We have compared the results to data from a Monte Carlo simulation and show that for a simple two-layered slab model of varying refractive index, the phase of the measured reflectance data is significantly altered by the variation in internal refractive index, whereas the amplitude data are affected only slightly.

Computer Simulation↗