Search PubMed⌕ Search

Biomedical subjects

H Tobin

Publications and source records attributed to H Tobin.

14 recordsLinked to original sources

A major, transformation-sensitive PKC-binding protein is also a PKC substrate involved in cytoskeletal remodeling.

Protein kinase C (PKC) plays a major role in regulating cell growth, transformation, and gene expression; however, identifying phosphorylation events that mediate these responses has been difficult. We expression-cloned a group of PKC-binding proteins and identified a high molecular weight, heat-soluble protein as the major PKC-binding protein in REF52 fibroblasts (Chapline, C., Mousseau, B., Ramsay, K., Duddy, S., Li, Y., Kiley, S. C., and Jaken, S. (1996) J. Biol. Chem. 271, 6417-6422). In this study, we demonstrate that this PKC-binding protein, clone 72, is also a PKC substrate in vitro and in vivo. Using a combination of phosphopeptide mapping, Edman degradation, and electrospray mass spectrometry, serine residues 283, 300, 507, and 515 were identified as the major in vitro PKC phosphorylation sites in clone 72. Phosphorylation state-selective antibodies were raised against phosphopeptides encompassing each of the four phosphorylation sites. These antibodies were used to determine that phorbol esters stimulate phosphorylation of serines 283, 300, 507, and 515 in cultured cells, indicating that clone 72 is directly phosphorylated by PKC in living cells. Phosphorylated clone 72 preferentially accumulates in membrane protrusions and ruffles, indicating that PKC activation and clone 72 phosphorylation are involved in membrane-cytoskeleton remodeling. These data lend further evidence to the model that PKCs directly interact with, phosphorylate, and modify the functions of a group of substrate proteins, STICKs (substrates that interact with C-kinase).

Amino Acid Sequence↗

Review of 10-year results of PCA hip arthroplasty.

OBJECTIVE: To assess the long-term results of the PCA uncemented total hip replacement. DESIGN: A prospective nonrandomized clinical trial. Follow-up ranged from 8 to 11 years (mean 10.3 years). SETTING: A university hospital. PATIENTS: One hundred consecutive PCA arthroplasties were performed on 89 patients. All operations were supervised by a single surgeon. The patients' status was reviewed between September and November 1996 by an independent observer. Seventy-three total hip replacements were available for review. INTERVENTION: PCA uncemented acetabular and femoral replacement through a lateral surgical approach. MAIN OUTCOME MEASURES: The need for revision, which was classified as failure, and definite 3-zone acetabular radiolucency, which was considered radiologic evidence of loosening. RESULTS: The time to failure of the acetabulum averaged 8 years. Femoral failure occurred in 3 patients an average of 4 years postoperatively. The overall failure rate for the acetabulum was 13% and for the femur 7%. CONCLUSIONS: The acetabular failure rate is unacceptably high. Patients who have had hip replacement with the PCA prosthesis should be followed over the long term.

Adult↗

Self-control across species (Columba livia, Homo sapiens, and Rattus norvegicus).

Data from six previous studies of self-control behavior were compared against predictions made by the matching law and by molar maximization. The studies involved pigeons (Columba livia), rats (Rattus norvegicus), and 3-year-old, 5-year-old, and adult humans (Homo sapiens) who had received food as the reinforcer, and adult humans who had received points exchangeable for money as the reinforcer. Neither theory proved to be an accurate or better predictor for all groups. In contrast to the predictions of these theories, self-control was shown to vary according to species, human age group, and reinforcer quality. When the reinforcer was food, the self-control of different species was found to be negatively correlated with metabolic rate; that is, larger species showed greater self-control. These results suggest that allometric scaling may prove useful in describing and predicting species differences in self-control.

Animals↗

The effect of variable delays on self-control.

Five pigeons served as subjects in an experiment that examined the effects of variable as opposed to fixed delays on preference in a self-control paradigm (choice between larger, more delayed and smaller, less delayed reinforcers). Nonindependent concurrent variable-interval schedules were used to measure choice. When delays to the larger, more delayed reinforcers were variable as opposed to fixed, the subjects showed an increased preference for that alternative (the self-control alternative). A series of regressions revealed that the hyperbolic decay model and incentive theory provided poor fits to the data, but a modified version of the generalized matching law provided an adequate fit. Together, consistent with a general prediction made by discounting models, the data supported the conclusion that variable delays can increase self-control. However, specific discounting models were not able to explain the present data well.

Journal Article↗

Cocaine decreases self-control in rats: a preliminary report.

Cocaine abuse is often associated with behavior that takes into account short-term, but not long-term consequences. However, there has been no empirical research concerning the effects of cocaine on self-control (choice of a larger, more delayed reinforcer over a smaller, less delayed reinforcer). In the present research, when food-deprived rats repeatedly chose between a larger, more delayed food reinforcer and a smaller, less delayed food reinforcer, chronic intraperitoneal injections of 15 mg/kg cocaine (but not 10 mg/kg fluoxetine) decreased the rats' choices of the larger, more delayed reinforcer. Cocaine can decrease rats' self-control.

Animals↗

Increasing the efficacy of gastric operations for the control of morbid obesity.

Based upon observations with double application of the TA90 surgical stapler in a stapled-in-continuity gastroplasty, we recommend a double application of gastric partitioning in the treatment of morbid obesity. The staple application should be closer than 0.5 cm or at least 2.0 cm apart to prevent necrosis of the intervening stomach. Division of the stomach between two staple applications with oversewing of the cut edges would preclude either staple line disruption or the danger of necrosis in the stomach intervening between stapler applications.

Animals↗