Search PubMed⌕ Search

Biomedical subjects

H Suh

Publications and source records attributed to H Suh.

101 records · Page 6Linked to original sources

Effect of citreoviridin and isocitreoviridin on beef heart mitochondrial ATPase.

Citreoviridin is a toxic metabolite from fungus that has been shown to be an inhibitor of mitochondrial F1-ATPases. Studies of citreoviridin, however, have been compromised by the light-dependent isomerization that it undergoes. The isomerization is a potential source of extensive variability in the studies, if citreoviridin and isocitreoviridin have different kinetic effects and binding properties. Both citreoviridin and isocitreoviridin recently have been purified and have been shown to be stable in the dark. Using the purified isomers, the effects of both citreoviridin and isocitreoviridin on soluble and membrane-bound beef heart mitochondrial F1-ATPase activity were investigated. It was found that citreoviridin was an uncompetitive inhibitor of ATP hydrolysis, and a non-competitive inhibitor of ITP hydrolysis catalyzed by soluble F1-ATPase. Isocitreoviridin had no effect on the hydrolysis of either of the triphosphates catalyzed by soluble F1-ATPase. The inhibition constant, Ki for citreoviridin was determined as 4.5 microM for ATP hydrolysis. The inhibition constants Kii and Kis for ITP hydrolysis were determined as 4.3 and 1.03 microM, respectively. Citreoviridin was an uncompetitive inhibitor of ATP hydrolysis and a noncompetitive inhibitor of ATP synthesis catalyzed by membrane-bound F1-ATPase. The inhibition constant, Ki, for ATP hydrolysis was around 4 microM. For ATP synthesis the inhibition constants were determined as 0.12 and 0.16 microM for Kis and Kii, respectively, when ADP concentration was kept saturating. Isocitreoviridin had no effect on either activity of the membrane-bound enzyme.

Adenosine Triphosphate↗

T cell receptor DJ but not VDJ rearrangement within a recombination substrate introduced into a pre-B cell line.

To elucidate mechanisms that regulate ordered and tissue-specific assembly of Ig and TCR variable region gene segments, we have introduced a recombination substrate comprised of germline TCR beta V, D, and J gene segments into an Abelson murine leukemia virus-transformed pre-B cell line that actively rearranges endogenous Ig H chain variable region gene segments but does not rearrange endogenous light chain or TCR variable region gene segments. We find that these cells efficiently join D beta segments to J beta segments within the mini-locus, but that they do not make any detectable site-specific rearrangements of the introduced V beta segment even though it is closely linked in the same construct to the D beta. These findings suggest that factors necessary for V beta to (D beta)J beta joining may be absent in these pre-B cells and also imply that the order in which TCR V beta, D beta, and J beta segments are rearranged can be influenced by factors other than the 12/23 recombination rule. Furthermore, in agreement with the an accessibility model of VDJ recombinase control, the D beta region of the construct was found to be relatively more sensitive to DNAase I digestion in isolated nuclei when compared to the unrearranged V beta region.

Abelson murine leukemia virus↗

Content and organization of the human Ig VH locus: definition of three new VH families and linkage to the Ig CH locus.

We present a detailed analysis of the content and organization of the human immunoglobulin VH locus. Human VH genes representing five distinct families were isolated, including novel members belonging to two out of three of the known VH gene families (VH1 and VH3) as well as members of three new families (VH4, VH5, and VH6). We report the nucleotide sequence of 21 novel human VH genes, many of which belong to the three new VH gene families. In addition, we provide a preliminary analysis of the organization of these gene segments over the full extent of the locus. We find that the five multi-segment families (VH1-5) have members interspersed over nearly the full 1500-2000 kb of the VH locus, and estimate that the entire heavy chain locus covers 2500 kb or less. Finally, we provide the first report of the physical linkage of the variable and constant loci of a human Ig gene family by demonstrating that the most proximal known human VH segments lie within 100 kb of the constant region locus.

Animals↗

Bacterial adhesion on PEG modified polyurethane surfaces.

Polyurethane surface was modified with poly(ethylene glycol) (mol. wt. 1000, PEG1k) carrying terminal hydroxyl, amino and sulfonate groups, poly(ethylene glucol) (mol. wt. 3350, PEG3.4k) and PEG3.4k-Heparin, respectively. These surfaces were investigated for bacterial adhesion using S. epidermidis and E. coli in tryptic soya broth (TSB), brain heart infusion (BHI), and human plasma. All PEG modified surfaces reduced bacterial adhesion significantly and the adhesion level differs depending on surfaces as well as media. In the case of PEG1k surfaces, no reduction of S. epidermidis adhesion was demonstrated in TSB media, regardless of terminal functional groups of PEG1k. However, adhesion in plasma was reduced to the different degree, depending on terminal groups of PEG1k (least adhesion on sulfonated PEG surface). Relatively longer PEG surface (PEG3.4k) and PEG3.4k-heparin surface minimized bacterial adhesion in both media. In the case of E. coli adhesion, significant reduction in adherent bacteria was observed on all PEG1k, PEG3.4k, and PEG-heparin surfaces in both media compared to controls. In contrast, no reduction in bacterial adhesion was demonstrated on poly(propylene glycol) (PPG1k) grafted PU surface as compared to control PU. These results suggest that surface modification with PEG1k-SO3, PEG3.4k and PEG3.4k-heparin seems to be effective for prevention of bacterial adhesion and subsequent infection.

Animals↗

Recombination between immunoglobulin variable region gene segments is enhanced by transcription.

Immunoglobulin (Ig) variable (V) region genes are assembled in precursor B (pre-B) lymphocytes from multiple germline segments. The heavy-chain V-region gene is composed of variable (VH), diversity (D) and joining (JH) segments; kappa (K) and lambda (lambda) light-chain V-region genes have analogous VL and JL segments. Assembly of Ig V-gene segments, as well as those of the highly related T-cell receptor, is regulated at several levels and shows both stage and tissue specificity; for example Ig heavy-chain V-gene assembly precedes that of Ig light chains during B-cell differentiation. Joining of all classes of V-gene segments involves conserved recognition sequences that are probably targets for a common recombinase. Evidence has been presented suggesting that rearrangement of specific classes of segments is regulated by modulation of their accessibility to the recombinase. To elucidate mechanisms which control V-region gene assembly, we have investigated the effect of flanking gene expression on the frequency at which introduced V-gene segments are assembled in pre-B cell lines. Our findings suggest that transcription may play a direct role in the regulation of immunoglobulin V-gene assembly.

Animals↗

Design and characterization of an intracavitary ultrasound hyperthermia applicator for recurrent or residual lesions in the vaginal cuff.

For evaluating the feasibility of treating recurrent lesions in the vaginal cuff by hyperthermia, a 2-element ultrasound applicator was designed, constructed and characterized. A half-cylindrical transducer (d=1 cm, length=1 cm) was used to construct the 2-element ultrasound applicator. Each element of this applicator was operated at 1.5 MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in the phantom. The element sizes used in this study were selected to be comparable to a high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of elements 1 and 2 were linear over this 1-40 W range and efficiencies were 32.2 +/- 3.4% and 46.2 +/- 0.8%, respectively. The temperature measurements in the phantom showed that a 6 degrees C temperature rise was achieved 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution and temperature rise in the phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermia to the vaginal cuff in the clinic.

Brachytherapy↗

Anti-infection treatment of a transcutaneous device by a collagen-rifampicine composite.

The polyurethane surface of a transcutaneous energy transmitter, which is implanted into a subcutaneous pouch for a total artificial heart, was coated with a Type I atelocollagen and rifampicine composite to prevent the infection that frequently occurs in the interfacial space between the tissue and the device. The specimen obtained after 7 weeks from a transcutaneous energy transmitter placed in a dorsal subcutaneous pouch of a dog revealed noninfected but well-attached dermal tissue without specific epithelial down-growth around the transcutaneous energy transmitter surface at the pouch-orifice area. The transcutaneous energy transmitter implanted in the pouch adhered well to the subcutaneous tissues. The collagen matrix seemed to have provided a favorable environment for the regenerating dermal tissue to obstruct the interfacial space. The coated collagen-antibiotic composite was degraded.

Animals↗

Biodegradable ceramic-collagen composite implanted in rabbit tibiae.

To develop an artificial bone substitute that would be gradually degraded and replaced by the regenerating natural bone, a carbonate apatite type I atelocollagen (82/12 in v/v%) composite was designed. The carbonate apatite synthesized at 58 degrees C demonstrated a crystallinity similar to that of natural bone. Type I atelocollagen was purified from human umbilical cords. Carbonate apatite-atelocollagen composite rods (diameter 6 mm x height 10 mm) were irradiated by ultraviolet ray (wave length 254 nm) for 4 hr to increase the collagen fibrillar cross links. Rabbit tibiae were dissected to prepare an artificial total bone defect (length 10 mm). The composites and porous hydroxyapatite rods, sintered at 1200 degrees C, were implanted into the defects and the tibiae were fixed by external osseofixators. The implanted composites were gradually degraded in the lesions, and the regenerated bone totally replaced the defects within 6 weeks, while the hydroxyapatite rod implanted lesions were not replaced by bone. No specific histologic abnormalities appeared in either the hydroxyapatite or composite rod implanted lesions.

Animals↗

Accuracy or bias in nurses' ratings of patient compliance: a comparison of treatment modality.

OBJECTIVE: The study examined the accuracy of nurses' assessments of patient compliance and identified factors influencing these assessments, including possible biases. DESIGN: Nurses' assessments of compliance, lab serum levels of dietary compliance, and interdialytic weight gain (IWG) were collected and compared to each other. End-stage renal disease (ESRD) patients on peritoneal dialysis (PD) and hemodialysis (HD) were compared on these measures and their compliance. SETTING: The study was conducted at the tertiary care university hospital at Stony Brook. PATIENTS: Data were collected for 62 ESRD patients (38 male, 24 female; mean age 54 years). The sample consisted of 26 HD and 36 PD patients. INTERVENTIONS: Nurses rated patients' compliance with fluid restrictions (HD patients only) and overall dietary compliance, as well as individual indicators of compliance including protein, potassium, and phosphorus compliance on a 7-point rating scale. Interdialytic weight gain, dietary (serum BUN and K levels), and medication compliance were recorded from charts for a 3-month period for each patient. MAIN OUTCOME MEASURES: The main outcome measures were the correlations between nurses' ratings of compliance and medical compliance data and the regression coefficients, which indicate the relative importance of each of the factors that nurses use to make their compliance ratings. RESULTS: Nurses' ratings for patients in both treatment modalities were highly correlated with the medical data for measures of fluid (r = 0.66, p < 0.001), potassium (r = 0.36, p < 0.01), and phosphorus (r = 0.36, p < 0.01). A regression analysis indicates that potassium (beta = 0.48, p < 0.001), phosphorus (beta = 0.19, p < 0.05), and protein (beta = 0.31, p < 0.01) all significantly contributed to nurses' assessments of patients' overall compliance. However, nurses' ratings of education levels for patients in both treatment modalities were not associated with phosphorus (r = 0.07, p < 0.61), protein (r = 0.18, p < 0.23), or potassium (r = 0.03, p < 0.85) measures. Finally, regressions revealed that nurses used personal knowledge of the patients when rating noncompliant patients (beta = 0.49, p < 0.05) but not when rating compliant patients (beta = 0.05, p < 0.75). CONCLUSIONS: Nurses rely heavily on medical records to rate patients' compliance and to make accurate assessments. Nurses also use several individual indicators (lab values and IWG) to rate overall dietary compliance, suggesting a thorough assessment. While assessments are not biased by personal factors such as nurses' perceptions of patients' education levels, nurses do rely on personal knowledge when rating noncompliant patients.

Adult↗