Search PubMed⌕ Search

Biomedical subjects

H Spanjers

Publications and source records attributed to H Spanjers.

10 recordsLinked to original sources

Calorimetric investigation of anaerobic digestion: Biomass adaptation and temperature effect.

A high-resolution bench-scale calorimeter (Bio-RC1), specially suited for microbiological studies, has been used to investigate the response of an anaerobic granular sludge to repetitive glucose additions at various temperatures. Through the analysis of heat-evolution profiles resulting from substrate degradation, significant biological events have been identified: the feeble net heat uptake related to aceticlastic methanogenesis has been evaluated, and the detrimental effect of a nutrient deficiency, which led up to 75% decrease in heat production rate, has been detected. After several glucose pulses under non-limiting nutrient conditions, a reliable and reproducible reference thermal response, which is an important condition for the application of calorimetric measurements to detect inhibitory effects, was finally obtained. Afterward, glucose additions were repeated at various temperatures, and 57% biomass activity reduction, with respect to the reference value at 35 degrees C, was observed when temperature was fixed at 20 degrees C. Additionally, a preliminary toxicity test was also performed by exposing the biomass to increasing formaldehyde concentrations.

Acetates↗

Literature review on textile wastewater characterisation.

In the textile industry, many different processes are used and almost all of them generate wastewater. The effluents resulting from these processes differ greatly in composition, due to differences in processes, used fabrics and machinery. Textile wastewater is usually treated as a mixed stream. For water and chemicals reuse purposes however, it is preferable to keep process streams apart and treat them separately. Characterisation of textile industry effluents is of great importance for the separate treatment of process streams. This literature review provides an overview of what is known about the wastewater of the separate processes, and the methods used for characterisation of these streams.

Humans↗

Mesophilic and thermophilic activated sludge post-treatment of paper mill process water.

Increasing system closure in paper mills and higher process water temperatures make the applicability of thermophilic treatment systems increasingly important. The use of activated sludge as a suitable thermophilic post-treatment system for anaerobically pre-treated paper process water from a paper mill using recycled wastepaper was studied. Two lab-scale plug flow activated sludge reactors were run in parallel for 6 months; a thermophilic reactor at 55 degrees C and a reference reactor at 30 degrees C. Both reactors were operated simultaneously at 20, 15 and 10 days SRT. The effects of temperature and SRT on sludge settleability and chemical oxygen demand (COD) removal efficiencies of different fractions were studied. Total COD removal percentages over the whole experimental period were 58+/-5% at 30 degrees C and 48 +/- 10% at 55 degrees C. The effect of the SRT on the total COD removal was negligible. Differences in total COD removal between both systems were due to a lesser removal of soluble and colloidal COD at 55 degrees C compared to the reference system. At 30 degrees C, colloidal COD removal percentages were 65+/-25%, 75+/-17% and 86+/-22% at 20, 15 and 10 days SRT, respectively. At 55 degrees C, these percentages were 48+/-34%, 40+/-28% and 70+/-25%, respectively. The effluent concentrations of colloidal COD in both systems were related to the influent concentration of colloidal material. The thermophilic sludge was not able to retain influent colloidal material as well as the mesophilic sludge causing a higher thermophilic effluent turbidity. Sludge settling properties were excellent in both reactor systems. These were neither temperature nor SRT dependent but were rather caused by extensive calcium precipitation in the aeration tanks creating a very dense sludge. For application in the board industry, a thermophilic in line treatment system seems feasible. The higher effluent turbidity is most likely offset by the energy gains of treatment under thermophilic conditions.

Bioreactors↗

Evaluation of control strategies using an oxidation ditch benchmark.

This paper presents validation and implementation results of a benchmark developed for a specific full-scale oxidation ditch wastewater treatment plant. A benchmark is a standard simulation procedure that can be used as a tool in evaluating various control strategies proposed for wastewater treatment plants. It is based on model and performance criteria development. Testing of this benchmark, by comparing benchmark predictions to real measurements of the electrical energy consumptions and amounts of disposed sludge for a specific oxidation ditch WWTP, has shown that it can (reasonably) be used for evaluating the performance of this WWTP. Subsequently, the validated benchmark was then used in evaluating some basic and advanced control strategies. Some of the interesting results obtained are the following: (i) influent flow splitting ratio, between the first and the fourth aerated compartments of the ditch, has no significant effect on the TN concentrations in the effluent, and (ii) for evaluation of long-term control strategies, future benchmarks need to be able to assess settlers' performance.

Benchmarking↗

Respirometry-based on-line model parameter estimation at a full-scale WWTP.

This paper describes part of a project to develop a systematic approach to knowledge extraction from on-line respirometric measurements in support of wastewater treatment plant control and operation. The paper deals with the following issues: (1) test of the implementation of an automatic set-up consisting of a continuous laboratory respirometer integrated in a mobile trailer with sampling and dosing equipment, and data-acquisition and communication system; (2) assessment of activated sludge/sewage characteristics from sludge respirograms by model parameter estimation; (3) comparison of the parameter estimates with regular plant data and information obtained from supplementary wastewater respirograms. The paper describes the equipment and some of its measuring results from a period of one week at a large-scale wastewater treatment plant. The measurements were evaluated in terms of the common activated sludge modelling practice. The automatic set-up allowed reliable measurements during at least one week. The data were used to calibrate two different version of the model, and independent parameter estimates were obtained.

Bioreactors↗

Status and future trends of ICA in wastewater treatment--a European perspective.

The status of instrumentation, control and automation (ICA) within the European wastewater community is reviewed and some major incentives and bottlenecks are defined. Future trends of ICA are also discussed. The information is based on a COST 624 workshop and a non-exhaustive survey with regard to ICA carried out in 13 European countries during March 2001. The level of instrumentation (type of sensors, usage frequency, etc.) and how these instruments are used for on-line control purposes are presented for each individual country (Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Netherlands, Romania, Slovenia, Spain, Sweden and Switzerland). The most common types of applied real-time control in wastewater treatment plants are given. One conclusion of the paper is that sensors no longer represent the main bottleneck for on-line control, rather the lack of plant flexibility is more troublesome. Moreover, the current transitional phase of the wastewater industry in Europe represents a unique opportunity to apply ICA on a large scale. The driving forces are simply too strong to ignore.

Automation↗

Respirometry techniques and activated sludge models.

This paper aims to explain results of respirometry experiments using Activated Sludge Model No. 1. In cases of insufficient fit of ASM No. 1, further modifications to the model were carried out and the so-called "Enzymatic model" was developed. The best-fit method was used to determine the effect of the proposed modifications. Increased agreement was found between simulated data and respirometry results, particularly for repeated respirometric tests with acetate as the sole substrate. Additionally, the influence of different biomass pre-conditioning methods was examined. Results from repeated respirometric tests suggest that presence of residual products in an activated sludge sample before respiration testing may decrease the sample's activity and significantly affect results from respirometric tests. An innovative approach to recover original activity is suggested by washing activated sludge samples with tap water or "mineral medium". As allylthiourea (ATU) was used in most experiments to suppress endogenous nitrification, its influence on kinetic parameters was reviewed. Respirometric tests confirmed that ATU addition has a significant effect on activity and respiration rate of activated sludge samples and could affect results of respirometric analyses.

Biomass↗

Parameter estimation procedure for complex non-linear systems: calibration of ASM No. 1 for N-removal in a full-scale oxidation ditch.

When applied to large simulation models, the process of parameter estimation is also called calibration. Calibration of complex non-linear systems, such as activated sludge plants, is often not an easy task. On the one hand, manual calibration of such complex systems is usually time-consuming, and its results are often not reproducible. On the other hand, conventional automatic calibration methods are not always straightforward and often hampered by local minima problems. In this paper a new straightforward and automatic procedure, which is based on the response surface method (RSM) for selecting the best identifiable parameters, is proposed. In RSM, the process response (output) is related to the levels of the input variables in terms of a first- or second-order regression model. Usually, RSM is used to relate measured process output quantities to process conditions. However, in this paper RSM is used for selecting the dominant parameters, by evaluating parameters sensitivity in a predefined region. Good results obtained in calibration of ASM No. 1 for N-removal in a full-scale oxidation ditch proved that the proposed procedure is successful and reliable.

Automation↗

Endogenous model state and parameter estimation from an extensive batch experiment.

In this paper an extensive batch experiment of endogenous process behavior in an aerobic biodegradation process is presented. From these experimental data, comprising measurements of MLVSS (mixed liquor volatile suspended solids) and respiration rate, in a first step the states and unknown parameters in a four-compartmental model are reconstructed analytically. Subsequently, for a selected set of states and parameters, using the results of the previous step, a recursive state estimation procedure, in particular an Extended Kalman filter-based observer, is applied to deal with the noise properties of the data appropriately. From this it appears that the initially proposed model structure, and especially the hydrolysis term, has to be modified.

Aerobiosis↗

Analysis of endogenous process behavior in activated sludge.

In this article, an autonomous four-compartment model that describes the endogenous respiration in an aerobic biodegradation process is proposed and analyzed theoretically. First, the multi-time scale of the system's behavior, to be taken into account in subsequent analyses, is emphasized. Then, an identifiability and observability study, given measurements of MLVSS (mixed liquor volatile suspended solids) and respiration rate, is performed for use under practical circumstances, such as in state and parameter estimation. It appears that the process is observable, but not fully identifiable. Hence, for the identification of some of the model parameters, additional measurements or experiments, also indicated here, have to be performed. Furthermore, it is shown that, under quasi-steady state conditions which, in general, appear shortly after initialization of an endogenous respiration experiment, the model can be reduced significantly. Finally, results of parameter estimation from available data are presented and discussed.

Aerobiosis↗