Atrial signal variations and pacemaker malsensing during exercise: a study in the time and frequency domain.

To give some explanation for atrial malsensing in dual chamber pacing that occurs only during exercise, atrial electrograms from 33 patients were telemetrically recorded and analyzed in both the time and frequency domains. During exercise, an overall decrease from 6.4 +/- 1.9 to 5.6 +/- 1.9 mV (-11%) in the atrial signal amplitude was noted. Despite considerable variability among patients, marked changes occurred in 15 patients whose signals diminished by 11 to 49%. Slew rates showed a similar decrease from 1.35 +/- 0.45 to 1.18 +/- 0.45 V/s (-10.8%), with individual changes of as much as -51%. Signal attenuation in the time domain correlated well with frequency data, exhibiting a highly significant reduction of signal energy between 25 and 105 Hz. However, spectral distribution changed from rest to exercise, with a relative increase of signal energy in the range between 5 and 25 Hz and a decrease at higher frequencies. Individual changes differed widely when low (15 to 65 Hz) and high (65 to 115 Hz) frequencies were compared, but in a group of 11 patients signal attenuation in the high frequency band was more pronounced (-45%) than in the low frequency band (-23%). The clinical impact of the change in frequency distribution during ergometry was visualized by computer simulation of two different (low and high bandpass) filters. Although in individual patients, both characteristics may be favorable with respect to atrial sensing, it was observed in 11 patients that high pass filtering attenuates signal amplitudes by 10 to 24% in excess of the variation without filtering.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Atrial sensing performance of AV universal pacemakers during exercise.

To investigate the atrial sensing function of dual chamber pacemakers during exercise, we studied 57 patients aged 12 to 81 years (m = 65). They were paced for sinoatrial disorders (n = 15), second or third degree AV block (n = 37), or binodal disease (n = 11). The examination was performed 3-24 months (m = 11) after pacemaker implantation. Individual sensing thresholds were determined at rest in the supine position, and proper detection of atrial signals at the programmed sensitivity level was verified during a period of 5-9 minutes (m = 5.8). Without a change in the program of the unit, symptom-limited bicycle ergometry was performed at a maximum load of 25-200 Watts (m = 95) and 6-channel chest wall electrocardiograms were continuously recorded throughout the test, including recovery. During exercise, 25/57 patients (44%) exhibited poor atrial sensing of the pulse generator; after termination of exercise in 16 of the 25 patients, proper atrial sensing resumed within 1 to 7 minutes of recovery. In the remaining nine cases, ergometry was continued after lowering the sensitivity threshold to half the initial setting or, depending on the pacemaker model, by a value of 0.4 mV. This resulted in normal function of the pulse generator in all patients but one, who needed a sensitivity adjustment of another 0.4 mV. In a subgroup of 25 patients, telemetric atrial electrogram recordings were monitored during ergometry, 19 of which could be evaluated quantitatively. Besides random atrial signal variations, presumably due to ectopic beats or runs, a systematic decrease of the peak-to-peak amplitude by 0.1 to 1.6 mV (3-30%) was observed in 16/19 patients during exercise. Mean signal reduction amounted to 11.8% and was statistically significant at the 0.1% level. It is concluded from these findings that, besides testing of atrial sensing at rest, the follow-up of dual chamber pacemakers should include an exercise test.

Adolescent↗

High-dose systemic streptokinase and acylated streptokinase-plasminogen complex (BRL 26921) in acute myocardial infarction: alterations of the fibrinolytic system and clearance of fibrinolytic activity.

We report the results of two consecutive studies using intravenous bolus injections of streptokinase (SK) or acylated plasminogen-SK complex (BRL 26921) in patients with acute myocardial infarction (AMI). In the first study, 20 patients received either 750,000 units (U) SK (group IA, n = 10) or 1,500,000 U SK (group IB, n = 10) within 5-10 min intravenously. In the second study 10 consecutive patients received 750,000 U SK within 15 min (group IIA) intravenously. The following 10 consecutive patients received 30 mg BRL 26921 within 2 min (group IIB). Early reperfusion was found in 16 patients in the first study (8 in each group) and in 18 patients in the second study (9 in each group). The decrease of fibrinolytic activity was biphasic with a half-disappearance time of 112.5 min for BRL 26921 and 31 (IA) and 18 (IB) min for SK. alpha 2-Antiplasmin depletion and a decrease of fibrinogen was observed with no differences after bolus injections of SK and of BRL 26921.

Aged↗

Measurement of factor VIII procoagulant antigen in normal subjects and in hemophilia A patients by an immunoradiometric assay and by an enzyme-linked immunosorbent assay.

Factor VIII coagulant antigen (FVIII:Ag) and FVIII coagulant activity (FVIII:C) were measured in 102 healthy individuals, in 5 hemophilia A carriers and in 21 hemophilia A patients before and after infusion of heat-treated high-purity FVIII concentrates. Factor VIII:Ag was determined by a solid-phase micro enzyme-linked immunosorbent assay (ELISA) using monoclonal antibodies and by a conventional solid-phase immunoradiometric assay (IRMA). Factor VIII:C was assessed using a one-stage assay. The micro ELISA was decidedly more precise than the IRMA. There was a close correlation between the results obtained by the three assays in the plasma of healthy subjects and in hemophilia A carriers. After transfusion of FVIII concentrates to hemophilia A patients, the FVIII:Ag recoveries were significantly lower than the FVIII:C recoveries and the biological half-life of FVIII:Ag was significantly shorter than for FVIII:C. The calculated half-life of FVIII:C was longer than in any previous study.

Adolescent↗

Factor VIII: C (FVIII: C) recovery and half-life after infusion of steam-treated high purity factor VIII concentrate in severe hemophilia A--comparison of one-stage assay, two-stage assay and a chromogenic substrate assay.

Factor VIII:C recovery and half-life was measured in 16 hemophilia A patients under comprehensively standardized conditions. Each patient received the same lot of a steam-treated high purity FVIII concentrate at a dose of 19-33 U/kg body weight. A comparison was made between the one-stage assay, the two-stage assay and a chromogenic substrate test for FVIII:C determination using a FXa-sensitive chromogenic substrate. Factor VIII:C potency of the administered FVIII concentrate was measured using calibration curves derived from a concentrate standard and FVIII:C plasma levels were read from calibration curves derived from a plasma standard. The chromogenic assay showed a good reproducibility at FVIII:C levels between 0.015 and 0.50 U/ml. The FVIII:C recoveries calculated from the results of the one-stage assay, the two-stage assay and the chromogenic substrate test were 109 +/- 20, 92 +/- 14 and 81 +/- 11% (mean +/- SD), respectively. The elimination half-lives of FVIII:C were calculated by non-linear least square analysis using a modified computerized Gauss-Newton algorithm. The half-lives calculated from the FVIII:C plasma levels measured by the one-stage assay, the two-stage assay and the chromogenic test were 23.8 +/- 6.4, 22.2 +/- 5.7 and 17.1 +/- 4.8 h (mean +/- SD), respectively. No previous study has reported such long half-life values. Our findings indicate that measurements of recoveries and half-lives by the chromogenic FVIII:C assay and by computerized non-linear least square analysis allow the possibility of individualized FVIII replacement therapy.

Adolescent↗

[Bolus injection of anisoylated plasminogen-streptokinase activator complex (BRL 26921) as an alternative concept of systemic lysis in acute myocardial infarct].

The thrombolytic properties of anisoylated plasminogen streptokinase activator complex (BRL 26921) and clinical results of the treatment were studied in 10 consecutive patients with acute myocardial infarction. Exclusion criteria were general contraindications against thrombolytic therapy and a time interval of more than 4 h between the onset of symptoms and admission to the hospital. All patients received a 250-mg bolus of prednisolone prior to intravenous injection of 30 mg BRL 26921 within 2 min. A continuous infusion of heparin at a dose of 1,000 USPU/h was started 2 h after the injection. Blood pressure was monitored via an arterial line. Arrhythmias and changes in the ST segments were documented by conventional ECG recording and computer-based ECG monitoring. Coronary arteriography and left ventriculography were carried out within 72 h. Besides routine laboratory tests, serial CK and CK-MB activity measurements were carried out. We determined the following hemostaseological parameters before and 15 min, 30 min, 1 h, 4 h, and 12 h after application of BRL 26921: prothrombin time, activated partial thrombosplastin time, thrombin time, thrombin coagulase time, fibrinogen, streptokinaseplasminogen activator activity, plasminogen and alpha-2-antiplasmin. Our results (reperfusion in all patients angiographically and in 7 to 8 of 10 patients from noninvasive criteria) show that BRL 26921 is a highly effective thrombolytic agent in patients with myocardial infarction, when compared with high-dose systemic fibrinolysis. Applied in dosages required for early reperfusion, it does not appear to be selectively thrombolytic and is not free of hypotensive effects in man. The decrease of fibrinolytic activity is biphasic with a half-disappearance time of 112 min.

Adult↗

[Thrombolytic therapy with ultra-high doses of streptokinase].

Two pilot studies were carried out in patients suffering from acute myocardial infarction. They received high doses of streptokinase and acylated streptokinase-plasminogen activator complex intravenously as a bolus injection. Furthermore, the possibility of using streptokinase bolus therapy was examined in patients with acute vascular occlusion. Due to the limited number and the heterogenicity of cases the results obtained in patients with acute myocardial infarction are to evaluate with some reservation. In patients with acute vascular occlusion streptokinase bolus therapy at high doses proved to be a promising alternative to the conventional therapy.

Coronary Angiography↗

Whipple's disease with aortic regurgitation requiring aortic valve replacement.

Cardiac involvement in Whipple's disease is well established. However, clinical consequences beside antibiotic therapy have rarely been reported. Our observation of a middle-aged man with increasing dyspnea, fatigue, chest pain, and dizziness leading to admission to a cardiology department demonstrates that cardiac symptoms may represent the main symptoms in patients with Whipple's disease. The diagnosis was not made prior to upper endoscopy, performed because of diarrhea, and revealed Whipple's agent now classified as Tropheryma whippelii, which is a PAS-positive rod-shaped bacterium in the macrophages of the intestinal lamina propria. The aortic valve was replaced after the intestinal symptoms were resolved by antibiotic treatment reducing the number of infectious agents in the duodenal mucosa. Histological analysis of the aortic valve demonstrated the presence of PAS-positive rod shaped material as the most likely cause of aortic insufficiency. Five months after valve replacement, the patient had completely recovered from intestinal and cardiac symptoms. Still under antibiotic treatment 16 months later, no more PAS-positive macrophages were detectable in the intestinal mucosa.

Aortic Valve↗

Influence of neutrophil separation on the expression of adhesion molecules.

In many assays of polymorphonuclear neutrophil (PMN) function the first step is separation of PMN from whole blood. In the present investigation it was examined if PMN separation leads to an altered expression of neutrophil surface membrane adhesion molecules. Samples have been taken from 20 healthy volunteers (10 male, 10 female; 39.7 +/- 11.8 years of age). PMN activation was measured cytometrically using the following antibodies against PMN surface membrane receptors: L-selectin (CD 62 L), beta-2-integrin Mac-1 (CD 11b) and Intercellular Adhesion Molecule 1 (CD54). PMN activation was determined in whole blood and after separation of PMN using density gradients. After PMN separation all three adhesion molecules appeared increased but the effect was only statistically significant for CD 54 (Wilcoxon test). Data (mean fluorescence intensity in arbitrary units) were: CD 62 L: 62 +/- 37 in whole blood, 82 +/- 28 after separation; p = 0.0674, CD 11b: 94 +/- 55 in whole blood, 111 +/- 47 after separation; p = 0.1454, CD 54; 13 +/- 12 in whole blood, 81 +/- 35 after separation; p < 0.0001. With the present data available it can be assumed that separation of PMN from whole blood can influence the results of flow cytometric assays.

Adult↗