Coefficient of variation: a powerful Doppler ultrasonographic parameter for detection of renal artery stenosis.

The aim of our study was to objectively compare the effectiveness of various Doppler parameters in the diagnosis of renal artery stenosis. In three sheep, variable degrees of renal artery stenosis were induced and renal segmental arteries were investigated using pulsed Doppler sonography. In each animal the standard deviation of the instantaneous peak velocity within one cardiac cycle normalized by the mean peak velocity (coefficient of variation) had significantly higher normalized regression coefficients (k* = -0.215, average of three animals) when compared to resistive index (k* = -0.090) and acceleration index (k* = -0.069). In each individual animal, coefficient of variation detected lower pressure gradients (6.3 mm Hg, average value) than did resistive index (13.4 mm Hg) or acceleration index (17.3 mm Hg). The coefficient of variation may detect the presence of pressure gradients in renal artery stenosis more accurately than acceleration index or resistive index.

Animals↗

[Circulatory support by an electrically stimulated muscle flap. Experimental experiences].

Functional electrical stimulation of the latissimus dorsi muscle flap for circulatory assistance extends the traditional concept of using this flap for reconstructive procedures into the field of cardiac surgery. It requires a transformed muscle which is able to contract for long periods of time without fatigue. Two main groups of experiments have been carried out in sheep. In six sheep the latissimus dorsi muscle (MLD) was transformed into a fatigue-resistant muscle by the means of multichannel stimulation of the supplying motor nerve. After that, stimulation of MLD at a frequency of 70 contractions per minute could be performed continuously without significant muscle fatigue. The loss of maximal force caused by the conditioning procedure was about one third of the initial force. In a second series of acute experiments the MLD was used for cardiomyoplasty. The muscle was divided into two parts which were wrapped around the heart in two different forms. The resting tension of the muscle was preserved. EKG-synchronous stimulation resulted in an increase in left ventricular pressure between 12 and 53%. The increase in arterial pressure was between 10,6 and 58%.

Animals↗

Pharmacologically induced heart failure for the evaluation of circulatory assistance.

For the evaluation of the hemodynamic interaction between the natural heart and an assist device, a reversible pharmacological model based on the channel blocker Verapamil under hyperkalemia, was developed for deterioration of left ventricular function. Four calves weighing 70-90 kg underwent standard implantation for left atrioaortal assist (BioMedicus, BP-80), pump anesthesia (oxygen/isoflurane [1%]; 8 mg/kg of BW/h ketamine), and of ventricular demand pacing at 120 bpm. Left atrial pressure (LAP), ventricular pressure (LVP), aortic pressure (AoP), pulmonary arterial (Qpulm) pressures, and graft flow (Qgraft) were monitored. The hemodynamic effects of anesthetic overdose (2% Isoflurane) were compared with those of Verapamil (Isoptin: 0.2 mg/kg BW/h 5 mmol/kg of BW/h of KCl) medication. Both regimens caused a decreased in AoP to < or = 50%. For Isoflurane, a slight reduction in cardiac output (CO) of 10% at a nearly constant LAP and a strong decrease of the peripheral resistance (Rperi) of 35% could be seen where Isoptin caused a significant reduction in CO of 40% at an increased LAP (+25%) and changes in Rperi of < 10%. Because the vascular tonus remains nearly constant, the hemodynamic effects are controllable and reversible (antagonized with calcium chloride); thus we conclude that Verapamil administration under hyperkalemia conditions is a proper model for mimicking congestive heart failure with low systemic side effects.

Anesthetics, Inhalation↗

Hemodynamic effects of prolonged abdominal insufflation for laparoscopic procedures.

Abdominal insufflation for laparoscopic procedures leads to numerous hemodynamic effects. We focused on blood flow distribution and arterial and venous pressure changes during CO2 insufflation at an intra-abdominal pressure of 12 mm Hg. Three segments of the vascular system were investigated (intrathoracic, cranial extrathoracic, caudal extrathoracic) in supine animals at insufflation, during a 90-minute period of pneumoperitoneum, and at desufflation. Except for instrumentation of the animals, no further surgery was performed. At insufflation (+5 minutes), cardiac output increased from 2.7 +/- 0.5 to 3.3 +/- 1.1 L/min while heart rate decreased from 138 +/- 26 to 128 +/- 17 beats per minute. Increases in jugular venous (from 6 +/- 1 to 11 +/- 4 mm Hg) and atrial (right, from 7 +/- 1 to 12 +/- 3; left, from 12 +/- 4 to 17 +/- 5 mm Hg) pressures occurred uniformly during inspiration. The great variance in atrial pressures during ventilation was not associated with changes in stroke volume, as the effective transmural filling pressures remained nearly constant. The increase in femoral venous pressure occurring during both inspiration and expiration (from 10 +/- 2 to 18 +/- 4 mm Hg) exceeded the increase in right atrial and jugular venous pressures during inspiration. Parallel increases were noted in arterial pressures (carotid, from 119 +/- 15 to 129 +/- 9; femoral, from 122 +/- 16 to 133 +/- 10 mm Hg), left ventricular pressure (from 133 +/- 17 to 143 +/- 10 mm Hg), and carotid and femoral flow (carotid, from 174 +/- 71 to 195 +/- 70; femoral, from 66 +/- 25 to 73 +/- 40 (NS) mL/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts.

OBJECTIVE: Compliance and formation of distal anastomotic intimal hyperplasia (DAIH) were investigated in externally stiffened venous grafts of varying calibers. METHODS: 36 femoropopliteal reconstructions were performed in 18 sheep. The autologous venous grafts were inserted into tubes made of Dacron mesh to achieve compliance-mismatch and lumen adaptation. Compliance was measured by echotracked ultrasonography and profiles of DAIH were generated from histologic sections harvested after 8.3 months. MAIN RESULTS: The external mesh tube significantly lowered the local compliance of graft and host artery. DAIH appeared extensively in those groups where mesh tube constricted venous grafts met untreated host arteries (p = 0.002). No differences in compliance and DAIH formation were observed when grafts with large and adapted diameters were compared. CONCLUSIONS: For prevention of DAIH the distal venous graft diameter is not important, while the local compliance of an autologous vein is a predictive factor for DAIH formation and thus long-term patency.

Anastomosis, Surgical↗

An implantable seal-less centrifugal pump with integrated double-disk motor.

Thrombus formation and sealing problems at the shaft as well as the compact and efficient design of the driving unit have been major difficulties in the construction of a long-term implantable centrifugal pump. To eliminate the problems of the seal, motor size, and efficiency, two major steps were taken by modifying the Vienna implantable centrifugal pump. First, a special driving unit was developed, in which the permanent magnets of the motor themselves are used for coupling the force into the rotor. Second, the rotor shaft in the pumping chamber was eliminated by adopting a concept recently presented by Ohara. The rotor is supported by 3 pins, which run on a carbon disk, whose concave shape leads to stabilization. The device has the following specifications: size: 65 mm (diameter) by 35 mm (height), 101 cm3; priming volume 30 cm3, 240 g; and a 6-pole brushless double disk DC motor. The required input power of the described prototype is 15 W at 150 mm Hg, 5 L/min (overall eta = 11%), and has an in vitro index of hemolysis (IH) of 0.0046 g/100 L. The test for in vitro thrombus growth exhibited far less thrombus formation in the new design than in designs with axles. In conclusion, the design of a special driving unit and the elimination of the axle led to the construction of a small pump with very low blood traumatization.

Biomechanical Phenomena↗

A clinical monitoring system for centrifugal blood pumps.

In clinical application of rotary blood pumps, flow obstruction as a result of suction of the inflow cannula, kinking of tubing, or thrombus formation occurs quite frequently. Early detection of such problems is essential to avoid hemolysis, tissue degradation, or release of thrombi to the patient. A program was developed for automatic observation of pump performance, tubing resistance, and suction effects, which requires only the measurement of already available parameters (i.e., pump speed, pump flow, aortic pressure). The software is based on Visual-C and provides a user surface formatted in Windows. Pump flow, its time derivate, and the relationship between the pulsatile component and the mean graft flow are observed to detect suction in the left atrium. Furthermore, the generated pressure head is predicted from pump speed, graft flow, and the resistance of tubing/cannula and compared with the actually measured aortic pressure. An alarm sounds if a given limit between prediction and measurement is exceeded. In a mock circulation, suction events were detected in more than 95% with a mean deviation of actual aortic pressure from its predicted value of less than 5%. For in vivo application, even incomplete suction could be detected reliably in more than 90% of events. This system improves and standardizes monitoring of pump performance; it should therefore lead to greater safety during application of such devices.

Algorithms↗

An artificial neural network-based noninvasive detector for suction and left atrium pressure in the control of rotary blood pumps: an in vitro study.

Rotary blood pumps are used in clinical applications to assist circulation via pumping blood from the left atrium to the aorta. Negative inflow pressures at high flow rates can cause suction of the cannula in the left atrium with deleterious effects on the atrial wall, the blood, and the lung. Therefore, stable and reliable detection of suction and the prediction of the left atrium pressure (LAP) would be of major interest for the control of these pumps. This work reports about an in vitro study of such a detector based on artificial neural networks (ANN). In the first project phase, an ANN was used to estimate the LAP based on pump speed, pump flow, and aortic pressure, obtained from a mock circulation. The inputs for the ANN were 11 characteristic values computed from these three parameters. In the second phase, another ANN was trained to classify various system states, such as suction, danger of suction (a state close to actual suction), and no suction. The first ANN was able to estimate the LAP with an accuracy of +/- 1.8 mm Hg. The discrimination of suction versus the other two states could be performed with a sensitivity and specificity of about 95% while the more interesting task of distinguishing danger of suction from no suction reached a sensitivity and specificity of about 65% (leaving 25% of each class unclassified and 10% of each class incorrectly classified).(ABSTRACT TRUNCATED AT 250 WORDS)

Atrial Function↗

Intrarenal Doppler ultrasonography: which vessel should be investigated?

The aim of our study was to determine whether the site of intrarenal Doppler measurement influences diagnosis of renal artery stenosis. In an experimental test, three sheep with variable degrees of renal artery stenosis were investigated. In each animal, the resistive index from renal segmental arteries correlated better with mean pressure gradient (r = 0.85, 0.71, 0.85) and had lower standard deviation (s = 0.02 to 0.05) than resistive index from interlobar arteries (r = 0.48, 0.54, 0.61) (s = 0.03 to 0.11). In two animals the difference was significant (correlation: P < or = 0.01, P = 0.13, P < or = 0.05; standard deviation: P < or = 0.01, P < or = 0.34, P < or = 0.05). For detecting renal artery stenosis, vessels within the renal sinus should be used for Doppler sampling.

Animals↗

The Vienna implantable centrifugal blood pump.

Because of the inherent disadvantages of membrane pumps, rotary pumps have been increasingly investigated in recent years. As a result of improving biocompatibility, extended assistance with implantable devices is of special interest. Questions arise concerning shear stress, blood traumatization, design of seals, and specific control conditions. In their development of an implantable impeller pump, the Vienna group studied the minimization of hemolysis and thrombus formation by means of numerical simulation, visualization, and in vitro blood evaluation. The latter was revealed to be the most powerful tool for pump evaluation. With optimization of geometry, a hemolysis of in vitro: IH = 0.008; MIH = 0.58; and in vivo: 2.1 to 3 mg% plasma-free hemoglobin could be obtained. For proper control and physiological adaptation, a controller based on a nonlinear and a fuzzy strategy was developed. Furthermore, a method for evaluation of the contractility of the assisted heart during nonpulsatile support was tested by computer simulation. This paper summarizes the evaluation methods used and provide an overview of the results of pump and controller design.

Animals↗

Experimental in situ conditioning of the latissimus dorsi muscle for circulatory assist by multichannel stimulation.

This study was undertaken to survey the changes in force and fatigue of the latissimus dorsi muscle during transformation into a fatigue-resistant muscle by indirect or nervous multichannel stimulation. In sheep, a silicone chamber connected to a pressure-transducing system was implanted under the left latissimus dorsi muscle. Muscle conditioning was performed by multichannel (carousel) stimulation of the thoracodorsal nerve. The program was started with active periods of 10 min/h producing 10 tetanic contractions/min. It was increased until 70 contractions/min could be performed during 24 h. The changes of muscle force and fatigue were monitored by the silicone balloon system. After a mean period of 22 weeks, fatigue resistance was reached. The fatigue-resistant muscle was able to produce a pressure of about 100 mm Hg in the balloon. After finishing the conditioning procedure, muscle forces and the fatigue resistance of the conditioned muscle were evaluated. The conditioned muscle showed only a minimal decrease of force during 20 min. Under a preload of 20 N, it exhibited a maximum tetanic tension of 95 N.

Animals↗

The Microspheres based Detoxification System (MDS). A new extracorporeal blood purification technology based on recirculated microspherical adsorbent particles.

Plasma sorption processes have so far been performed with filters and appropriate adsorption columns. In this paper, we introduce a newly developed plasma sorption system, which is based on the high adsorption capacity of microspheres in a recirculation system. The technology has been applied successfully in vitro to eliminate endotoxins, low density lipoproteins (LDL) and barbiturates from human plasma.

Animals↗

Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: a manifestation of pressure recovery.

OBJECTIVES: This study investigated the effect of stenosis geometry on the Doppler-catheter gradient relation. BACKGROUND: Although gradient estimation by Doppler ultrasound has been shown to be accurate in various clinical and in vitro settings, there have also been reports of substantial discrepancies between Doppler and catheter gradients. These conflicting results may be due to differences in geometry and hemodynamic characteristics of flow obstructions. METHODS: Stenoses of various geometry were simultaneously studied with continuous wave Doppler and catheter technique in a well controlled pulsatile flow model. RESULTS: Doppler and catheter gradients correlated very well regardless of stenosis geometry and site of distal catheter measurement (r = 0.98 to 0.99, SEE = 1.8 to 5.3 mm Hg). When the catheter was pulled back through the stenosis, the highest gradients were found in or close to the stenosis. When these catheter gradients were compared with Doppler gradients, the agreement between the two techniques was excellent regardless of stenosis geometry (slope 0.97; mean difference 0.6 +/- 2.0 mm Hg). However, when distal pressures were measured 10 cm downstream from the stenotic segment, the slope of the regression line, and therefore the agreement between Doppler and catheter gradients, differed for the different stenosis types (slopes from 0.98 to 1.69). In stenoses with abrupt narrowing and abrupt expansion, agreement was acceptable. Doppler gradients were only slightly greater than catheter gradients (mean difference 4.5 +/- 5.2 mm Hg). In stenoses with a gradually tapering inlet and outlet, the Doppler-catheter gradient relation was dependent on the outflow angle. Good agreement was found for an angle of 60 degrees (mean difference 0.6 +/- 1.8 mm Hg). In stenoses with a 40 degrees outflow angle, Doppler gradients exceeded the catheter gradients by 13% on average; for stenoses with a 20 degrees outflow angle, Doppler gradients exceeded catheter gradients by 46 +/- 11.4%, with differences as great as 65 mm Hg. These results were identical for stenoses gradually tapering outward to the distal tubing diameter and those with abrupt expansion after 2 cm of gradual expansion. The results were also not affected by changing the inflow angle from 20 degrees to 60 degrees. However, an abrupt narrowing instead of a tapering inlet significantly altered the Doppler-catheter gradient relation (p < 0.001); Doppler gradients exceeded the catheter gradients by 34 +/- 10% for this stenosis type. CONCLUSIONS: Doppler gradients accurately reflect the highest gradients across flow obstructions that occur in the vena contracta. However, these gradients may be significantly greater than catheter gradients that are measured farther downstream, as is usually the case in clinical catheterization studies. These discrepancies are due to pressure recovery. The magnitude of pressure recovery is highly dependent on the stenosis geometry, which therefore significantly affects the Doppler-catheter gradient relation. It is the outflow geometry that predominantly influences this relation, but the shape of the inlet may affect the results as well. Although pressure recovery occurs even in stenoses with abrupt narrowing and abrupt expansion, the phenomenon is most likely to become clinically relevant in stenoses with a gradually tapering inlet and outlet with an outflow angle < or = 20 degrees.

Blood Pressure↗

In vitro hematological testing of rotary blood pumps: remarks on standardization and data interpretation.

Pump test procedures using blood will have to meet several standards not only to obtain reliable results in vitro but also to allow comparison of results of different investigators. This article reviews some of the issues that should be considered in pump testing, especially referring to the discussions held at the International Workshops on Rotary Blood Pumps in 1988 and 1991. The test loop itself should meet some requirements such as constant physiological temperature, standardized circulating volume, control of pressure and flow, and exact definition of the blood-contacting surface. Specifications have to be made concerning the test fluid blood, including sampling technique, anticoagulation, blood gases, pH, and glucose level. Only fresh blood should be used. Heparin is recommended for anticoagulation because it will be used also in vivo. Different procedures for cleaning and rinsing of plastic materials for reuse are mentioned. Bacterial overgrowth, which can lead to extreme oxygen consumption and acidosis, may be avoided through addition of antibiotics (e.g., gentamicin). To be able to compare data of the different working groups, a new modified index of hemolysis (MIH) has been defined.

Animals↗

Mechanical blood traumatization by tubing and throttles in in vitro pump tests: experimental results and implications for hemolysis theory.

Blood has become essential as a test fluid to evaluate hemolysis and biocompatibility of blood pumps in vitro. The blood is usually pumped from a blood bag into a circuit against elevated pressure. A throttle or a length of tubing is used to produce the pressure head. Blood damage caused by the shear stress in these pressure-reducing devices should be minimal. It is not known whether the high but short-lasting shear stress in a throttle is more or less damaging to the blood than the low but long-lasting stress in tubing. In this study, throttles (width 11 mm, minimal height 0.9 mm, length 30 mm; shear stress = 136 N/m2 lasting for 3.23 ms); and tubing (inner diameter 9.5 mm, length 4.5 m, shear stress = 4.5 N/m2 lasting for 3.5 s) were compared at a flow of 5 L/min and a pressure drop of 150 mm Hg. Experiments (n = 10) with bovine blood were performed in two parallel setups using Bio-Medicus pumps BP80. Free hemoglobin in plasma (fHb) and thromboxane B2 (TXB2) were measured. After 6 h, the fHb increase was 31.9 +/- 19.1 mg% for the throttle setup and 32.3 +/- 16.2 for the tubing setup. The TXB2 release was 296 +/- 70 and 305 +/- 54 pg/0.1 ml respectively after 4 h. In summary, no significant differences between the two setups for either fHb or TXB2 could be detected. So the use of a throttle, which requires far less priming volume and a smaller blood-contacting surface while also offering a wider range of adjustment, seems preferable.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

In vitro investigation of thrombogenesis in rotary blood pumps.

Thrombus formation at sealing and stagnation areas remains a major problem in the development of rotary blood pumps. Until now, the complex phenomena could only be studied in vivo. In this study, an in vitro mock circulation previously used for hemolysis studies was adapted for thrombosis evaluation. Blood was collected in the slaughterhouse with strict avoidance of air contact and was heparinized (1.5 U heparin/ml blood; activated coagulation time [ACT]: initially, 140-180 s; after collection, 400-600 s). During the test, the ACT decreased gradually. The tests were stopped after 90 to 180 min at an ACT of 1.5 times the initial value. Thrombus formation was observed at the same locations as observed in left-heart assist devices (sealing area, connecting bolts, and stagnant water areas at connectors). The thrombi were similar in shape, color, and histology to those found after 2 to 4 days in vivo. This test provides a valuable tool for evaluating thrombus formation in prototypes and screening tests of different rotary pump designs.

Animals↗