Search PubMed⌕ Search

Biomedical subjects

H Schieffer

Publications and source records attributed to H Schieffer.

At least 55 records · Page 3Linked to original sources

[Biatrial stimulation in therapy of paroxysmal atrial tachycardia: a case report].

A biatrial pacemaker was inserted in a 68-year-old female with paroxysmal atrial fibrillation and atrial flutter refractory to antiarrhythmic drugs based on a sick-sinus-syndrome and concomitant interatrial conduction delay. One electrode positioned in the right atrium and another electrode located in the coronary sinus were connected to a dual-chamber pacemaker. The electrode in the right atrium was connected to the atrial channel, the electrode in the coronary sinus to the ventricular channel. The pacemaker was programmed in DDD-mode with an AV-delay of 30 ms. Under a chronic antiarrhythmic medication with 160 mg sotalol per day there was no evidence for recurrent episodes of atrial tachyarrhythmias in the patient's history, 24-h-Holter-ECG, nor in the memory of the pacemaker during a follow-up of 8 months.

Aged↗

Facilitating influence of procainamide on conversion of atrial flutter by rapid atrial pacing.

In a prospective, double-blind, randomized, placebocontrolled study we investigated the facilitating influence of intravenous procainamide on conversion of atrial flutter by rapid atrial pacing. Fifty consecutive patients with spontaneous sustained atrial flutter were 1:1 randomized into two homogenous groups: group A received 10 mg.kg-1 procainamide intravenously, group B placebo. After infusion there was a significant (P < 0.01) lengthening of the flutter cycle with respect to baseline in group A, exceeding the flutter cycle length of the control group (P < 0.05). The overall success rate of rapid atrial pacing in restoring sinus rhythm was significantly higher after pre-treatment with procainamide compared to placebo (100% vs 76%; P < 0.05): 20 patients of group A reverted immediately after pacing to sinus rhythm, the remaining five after a brief episode of atrial fibrillation. In the placebo group, 16 patients showed a prompt conversion to sinus rhythm and three after transient atrial fibrillation. In the remaining six patients, due to sustained pacing-induced atrial fibrillation, direct current cardioversion was necessary. After administration of procainamide a less aggressive stimulation protocol with significantly (P < 0.01) longer paced cycles to interrupt atrial flutter was achievable. In conclusion, intravenous procainamide augments the efficacy of atrial pacing to convert atrial flutter to sinus rhythm.

Adult↗

Chronic ventricular pacing using an output amplitude of 1.0 volt.

Thirty-seven patients (21 male, 16 female, mean age 71 years) received identical DDD pacemakers. They also received the same bipolar ventricular passive fixation electrode, which has a microporous tip of platinum-iridium, a surface area of 5.8 mm2, and steroid elution. Eighteen months after implantation the ventricular charge threshold [microC] was measured telemetrically at 0.5, 1.0, and 2.0 V, respectively. For the 1.0 and 2.0 V amplitudes the pulse duration was increased until the charge per pulse [microC] was twice the threshold value, thus giving a 100% safety margin in terms of charge ("safety charge"). Patients who had ventricular capture at 0.5 V were permanently programmed to 1.0 V (30/37 patients), while those who did not capture at 0.5 V were set to 2.0 V (7/37 patients). In both cases, the pulse duration was programmed according to the rationale of "safety charge." During a routine follow-up period of 6 months, no complications were observed and none of the patients suffered from symptoms indicating loss of ventricular capture. Twenty-four-hour Holter recordings, obtained from all patients at the end of the follow-up with the output parameters unchanged, revealed constant ventricular capture. In patients with chronic stable pacing thresholds and steroid-eluting low threshold leads who have capture at 0.5 V, chronic ventricular pacing at an output amplitude of 1.0 V is feasible, and it seems to be safe if the pacing threshold is measured as charge delivered per pulse and a 100% safety margin in terms of charge is programmed. Reducing the output amplitude to well below the battery voltage may increase pacemaker longevity.

Aged↗

Low energy transvenous cardioversion of short duration atrial tachyarrhythmias in humans using a single lead system.

The purpose of this study was to investigate the efficacy and safety of atrial cardioversion using an endocardial single lead system presently used for ventricular defibrillation. The study population consisted of 26 recipients of an ICD in combination with a conventional endocardial single lead system with the proximal spring electrode as anode in the SVC and the distal as cathode in the apex of the RV. Atrial tachyarrhythmias were induced by right atrial burst pacing. If the arrhythmia sustained > 1 minute, biphasic shocks synchronized with the R wave were delivered using the implanted device, beginning with an energy of 4 J. If 4 J failed to terminate the arrhythmia, energy was increased stepwise, if the first shock was successful, a step-down testing was performed after reinduction of atrial tachyarrhythmias. The mean atrial defibrillation threshold was 2.3 +/- 1.2 J (range, 0.5-5 J). A total of 154 shocks were delivered and no adverse effects were observed. The mean defibrillation threshold for atrial flutter was somewhat lower than that for AF (1.8 +/- 1 J vs 2.7 +/- 1.4 J, P = 0.08). There was no correlation between the atrial defibrillation threshold and a history of previously occurring atrial tachyarrhythmias, the kind of the underlying heart disease, a prescription of antiarrhythmic drugs, the dimension of the LA, the LVEF, or the ventricular DFT. Internal atrial cardioversion of short duration atrial tachyarrhythmias using a transvenous single lead system designed for ventricular defibrillation is feasible and safe at low energies, and may have important clinical applications.

Adult↗

Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?

The purpose of this study was to determine the termination and acceleration rates for 1 to 6 attempts of antitachycardia pacing [ATP] delivered by ICD in order to terminate spontaneously occurring VTs. Twenty-four ICD recipients with active ATP programs, including a maximum of six ATP sequences and spontaneously occurring VTs during follow-up, were investigated. During a mean follow-up of 42 +/- 15 months (range, 17-63 months) 413 spontaneous VT episodes (17 +/- 14; range, 1-49 per patient) resulting in appropriate ATP delivery by the ICD occurred. ATP successfully terminated 328 episodes (80%) with a mean number of 1.6 +/- 1.1 pacing sequences. Eighty episodes (19%) were accelerated by ATP and 5 (1%) were unresponsive to ATP. The ATP success decreased until the third ATP sequence (59%-->31%-->24%), but increased again in the fourth to sixth attempt (46%-->46%-->29%). The acceleration rate increased from sequence one to sequence three (8%-->13%-->28%), but decreased significantly in further ATP attempts (19%-->0%-->0%). The mean time delays until redetection or termination after 4, 5, and 6 attempts of ATP were 22 +/- 5 seconds, 37 +/- 2 seconds, and 41 +/- 9 seconds, respectively. Nine patients (37%) used > or = 3 ATP attempts during follow-up and all of them had a therapeutic benefit from it. Five out of 13 VTs (38%) treated with > or = 4 attempts could ultimately be terminated by ATP. The results of this study demonstrate that the first ATP sequence is the most effective and that > 4 ATP attempts may be useful in a minority of patients. There seems to be a low risk of VT acceleration by the fourth to sixth ATP sequence. Because of the associated time delay, a high number of ATP attempts should only be programmed in patients with hemodynamically well-tolerated stable VTs.

Acceleration↗

Optimizing the AV delay in DDD pacemaker patients with high degree AV block: mitral valve Doppler versus impedance cardiography.

In DDD-pacemaker patients with high degree AV block, Doppler echocardiography of transmitral blood flow can be used to find the individually optimal AV delay (AVO) for left heart AV synchronization. This study tried to validate a Doppler method (ECHO) recently proposed to optimize left ventricular filling by comparing it to stroke volume data derived from impedance cardiography (ICG). It should be further elucidated if optimizing the AV delay (AVD) by means of this method is superior to fixed AVD settings and which differential AVD (pace-sense-offset) should be programmed for atrially triggered (ATP) and AV sequential (AVP) pacing, respectively. AVO as measured in 53 patients showed a linear correlation between ECHO and ICG for both ATP (r = 0.66, P < 0.00001) and AVP (r = 0.53; P < 0.005). The mean deviation in AVO between ECHO and ICG was +/- 26 ms (ATP) and +/- 30 ms (AVP), respectively, with a tendency to longer AVDs with the Doppler method. ECHO limitations could mainly be attributed to: (1) restrictions of AVD programming options (which may be compensated for by slight modification of the proposal); and (2) to pathophysiological mechanisms that alter mitral valve dynamics. Optimization of the AVD by Doppler produced a stroke volume that was significantly higher (19%) than with a fixed AVD (150 ms in ATP; 200 ms in AVP). There was a wide scatter in pace-sense-offsets between-7 and 134 ms, which was reflected by both methods. It is concluded that AVO determinations by ECHO are valid provided that methodological pitfalls and limitations caused by the disease are recognized. Tailoring AVD with respect to diastolic filling improves systolic function and is superior to nominal AVD settings. Fixed differential AVDs as offered by some manufacturers are far from being physiological. Thus modern pulse generators should offer free programmability over a wide range of AV delays.

Atrioventricular Node↗

Atrial defibrillation: can modifications in current implantable cardioverter-defibrillators achieve this?

Atrial fibrillation (AF), the most common arrhythmia resulting in hospital admission, is a major health problem. The limited efficacy of antiarrhythmic drugs to control this rhythm disorder and their potential proarrhythmic risk led to the development of new techniques to ameliorate the treatment of AF. Transvenous atrial defibrillation using endocardial electrodes has been shown to be effective at low energy levels. An implantable atrial defibrillator could be a potentially valuable treatment option for patients with paroxysmal AF that is medically refractory. Research is currently under way to investigate several critical issues concerning this new therapeutic concept: long-term efficacy, safety, patient's tolerance, and an acceptable cost/benefit ratio. It is well known that AF often complicates the use of the implantable cardioverter-defibrillator (ICD) for ventricular tachyarrhythmias. Therefore, it would seem desirable to implement the capability for atrial defibrillation into current ICD systems. It has been shown that atrial defibrillation, using endocardial lead configurations specifically designed for ventricular defibrillation, is feasible at energies well within the capabilities of current ICD technology. Further research is needed to evaluate if some enhancement of the lead configuration in combination with possible advanced technology could reduce the atrial defibrillation threshold to a well tolerated level as a prerequisite for automated atrial defibrillation, in ICD recipients with concomitant paroxysmal AF.

Animals↗

[The prevalence of sleep-related breathing disorders in patients with implanted cardioverter-defibrillators. The effect on the incidence and circadian distribution of malignant ventricular tachyarrhythmias].

OBJECTIVE: To determine the prevalence of sleep-related breathing disorders (SRBD) on patients who, because of malignant ventricular tachyarrhythmias associated with cardiac disease, have an implanted cardioverter-defibrillator (ICD). It was also investigated whether the frequency and circadian distribution of spontaneous ventricular tachycardia and (or) fibrillation (VTF) can be influenced by SRBD. PATIENTS AND METHODS: 29 consecutive ICD patients (28 men, one woman; mean age 64 +/- 8 years) were investigated by multifunction recordings. 22 patients had coronary heart disease, and seven dilated cardiomyopathy. For each patient the number of VIF episodes per month were recorded, as well as the percentage distribution of the episodes during the day per hour and after grouping into four time periods. RESULTS: SRBDs were recorded in 13 of the 29 patients (45%) (apnoea-hypopnea index [AHI] > 10). The other 16 patients had normal findings (AHI < or = 10). Mean frequency of the registered VTF attacks was similar in both groups (0.41/month with AHI < or = 10 vs 0.44/month with AHI > 10; difference not statistically significant). Averaged percentage distribution pattern showed a maximum frequency in both groups between 6 o'clock and 12 o'clock a.m. There was no significant increase of VTF during the night (10 o'clock p.m.-6 o'clock a.m.) in the group with SRBD (19% with AHI > 10 vs 18.2% with ATF < or = 10; difference not significant). CONCLUSION: There was a high prevalence of SRBD in the patients with ICD and underlying cardiac disease. No influence of SRBD on frequency and circadian distribution of VTF was demonstrated in patients with ICD during long-term observation.

Aged↗

Progress in the prostaglandin E1-therapy of the intermittent claudication by means of bolus injections of LIPO-prostaglandin E1 (LIPO-PGE1).

OBJECTIVE: We compared the efficacy of a bolus injection (5 min) of LIPO-PGE1 (Prostaglandin E1 in lipid emulsion) with conventional PGE1-cyclodextrin (PGE1-cyclodextrin) infusions (2 h) in patients with intermittent claudication. The quantitative blood-flow in the common femoral artery was measured using a computerized ultrasound Doppler system (MAVIS). We also monitored the transcutaneous oxygen pressure, the skin temperature on the foot, and the reactive change in blood pressure and pulse as well as side effects. RESULTS: Dose finding of LIPO-PGE1: After bolus injection of 30, 50, and 80 micrograms LIPO-PGE1 a significant dose-dependent increase of the blood flow in the leg (+96.9%, 80 micrograms) with a peak 3 h after injection was seen. After LIPO-PGE1 we observed an enhanced microcirculation (significant rise in the transcutaneous oxygen pressure and the skin temperature on the foot). We noted longer lasting pharmacodynamic properties with LIPO-PGE1 (50 micrograms) compared to PGE1-cyclodextrin (60 micrograms). Comparison to PGE1-cyclodextrin: In a cross-over, placebo-controlled study, 20 patients with intermittent claudication received 4 weeks therapy with a bolus of 50 micrograms LIPO-PGE1 or a 2 h infusion of 60 micrograms PGE1-cyclodextrin per day. A significant increase in the blood flow was measured at the end of 4 weeks therapy compared to the initial values before treatment. This rise correlates significantly with the increase in the patient's maximal walking distance (+112%, LIPO-PGE1). Compared to conventional PGE1-cyclodextrin infusions given over 2 h, a clearly prolonged increase in perfusion of the affected limb after LIPO-PGE1 was demonstrated. No serious adverse effects were observed.

Aged↗

Determinants of the natural course of ventricular late potentials after thrombolytic therapy for acute myocardial infarction.

The intraindividual changes of ventricular late potentials and their possible determinants were examined prospectively in 88 consecutive patients (male: 75; mean age: 58 +/- 9 years) after thrombolytic therapy for acute myocardial infarction. Late potential analysis was performed 4 weeks and 12 months after acute myocardial infarction. At the same time, a left heart catheterization was performed to assess the extent of coronary heart disease and left ventricular ejection fraction. The incidence of late potential 4 weeks after acute myocardial infarction was 15% (13/88 patients). Eighteen percent (16/88) of the patients revealed changing results of late potential analysis: 9 patients lost late potential (late potential pos./neg.) 1 year after acute myocardial infarction and 7 patients presented new formation of late potential (late potential neg./pos.). Preserved late potentials were found in four patients (late potential pos./pos.). Late potential analysis remained negative in 68 patients (late potential neg./neg.). There was no influence of age, gender, site of infarction, clinical course, and medical treatment on the natural course of late potential. Changing results of late potential analysis seemed to be correlated with the evolution of left ventricular ejection fraction and the dynamics of coronary heart disease. In the group late potential pos./pos., comparable values for left ventricular ejection fraction were measured at both examinations, whereas late potential neg./neg. had a significant increase in ejection fraction. In the group late potential pos./neg., a significant improvement in left ventricular function was also measured. In contrast, the late potential neg./pos. group tended to have lower left ventricular ejection fractions 1 year after infarction. In the late potential neg./pos. and late potential pos./pos. groups, the extent of coronary artery disease returned to conditions comparable to baseline despite an initial reduction after coronary revascularization performed 4 weeks after infarction. Late potential neg./neg. and late potential pos./neg. revealed a stable benefit gained from coronary revascularization with a persistent reduction in the number of diseased vessels. Dynamic changes in the results of the signal-averaged ECG 1 year after thrombolytic therapy for acute myocardial infarction were observed in 18% of the patients. These changes seem to be correlated with the evolution of left ventricular function and the dynamics of coronary artery disease.

Action Potentials↗

Influence of a non-ionic radiography contrast medium on the microcirculation.

UNLABELLED: PURPOSE, MATERIAL AND METHODS: Microcirculatory disturbances may be responsible for some of the adverse effects induced by contrast media. The influence of iopromide 370 (Ultravist) on cutaneous microcirculation was therefore investigated in 15 patients in a prospective study. Twenty ml of iopromide and 20 ml 0.9% NaCl were injected as reference in the subclavian artery at the beginning of a diagnostic coronary angiography. Erythrocyte velocity was measured in ipsilateral nailfold capillaries at the beginning of, during, and after the injection continuously up to 6 min after injection. RESULTS: On average, 30 s after injection of contrast medium, erythrocyte velocity decreased significantly by 51.3% (p<0.0001) and remained reduced up to 120 s. This reaction was observed in 14 out of 15 patients. Three patients showed a temporary cessation of capillary blood flow. CONCLUSION: The adverse effects sometimes seen during coronary angiography can be explained if similar contrast medium induced microcirculatory disturbances in the myocardial vasculature.

Adult↗

[Diurnal distribution of spontaneous ventricular tachyarrhythmias in patients with implanted cardioverter defibrillator].

The purpose of this study was to analyze temporal patterns of spontaneous ventricular tachyarrhythmias in patients (p) with implantable cardioverter-defibrillator (ICD). By reading out the ICD-data logs 725 arrhythmic episodes (e) from 43 patients were investigated. After grouping the episodes into four defined time periods (period 1: midnight to 6 a.m., period 2: 6 a.m. to noon, period 3: noon to 6 p.m., period 4: 6 p.m. to midnight) according to the data stored by the device, the percentage of episodes per time period has been calculated for each patient who experienced at least 10 arrhythmic events (n = 22). A significant peak occurrence (mean 34%) could been demonstrated for the morning hours (period 2). Analyzing patients individually, 4 subgroups could be identified: group 1 with an episode peak in period 2 (9 p, 277 e, p < 0.01), group with an episode peak in period 3 (4 p, 83 e, p < 0.01), group 3 with a peak occurrence in period 4 (3 p, 110 e, p < 0.01) and group 4 with an equal episode distribution over all four time periods (6 p, 187 e). Comparing sustained and nonsustained tachyarrhythmias, the nonsustained episodes were found to be distributed much more equally, meanwhile the circadian variation for fast (HR > or = 240/min) and slower (HR < 240/min) arrhythmias was identical. Regarding episodes of patients on beta-blocker or class III-antiarrhythmic therapy the same circadian variation has been found. There was no significant difference between the subgroups of patients with an episode peak in period 2 and the other patients concerning age, sex, cardiac disease, left ventricular ejection fraction, clinical arrhythmia, beta-blocker or class III-antiarrhythmics, number of recorded episodes or follow-up time. Further studies are needed to determine a possible correlation between these findings and different circadian variations in individual psychovegetative activity.

Adult↗

[Flow rates of roentgen contrast media of different viscosity in 4.1 Charrière coronary catheters].

The studies presented here investigated the obtainable flows of different contrast media (Iopromide 370 mg iodine/ml, ZK 119 095 370 mg iodine/ml, ZK 139 129 370 mg iodine/ml, Iopamidol 370 mg iodine/ml, Iopromide 300 mg iodine/ml, ZK 119 095 300 mg iodine/ml, ZK 139 129 300 mg iodine/ml, Iopamidol 300 mg iodine/ml, aqua dest.) in 4.1 Charrière coronary catheters. The measurements of the flow achieved by a standardised power of 100 N show that the highest values are reached with the substance ZK 119 095 (both for 300 mg iodine/ml and 370 mg iodine/ml). On comparison of the catheter types there are no differences in the delivery rate. The x-ray contrast-media, however, are significantly different: the lowest iodine delivery rate is found for iopromide 370 with 384.5 mg iodine/s; the highest rate for the test substance ZK 119 095 with 648.9 mg iodine/s. Although contrast media with low viscosity contain considerably less iodine/ml it is possible to achieve an iodine density in coronary vessels by about 86% higher than that achieved by contrast media with 370 mg iodine/ml. Therefore, the possibility to choose a viscosity-adapted x-ray contrast-medium allows the use of very thin cardiac catheter systems without leading to a worsening of picture quality.

Cardiac Catheterization↗

[Initial clinical experiences with low energy internal cardioversion of chronic atrial fibrillation after unsuccessful external cardioversion].

Between January and September 1995, 54 consecutive patients (male: 34, age: 66 +/- 10 years) with symptomatic chronic atrial fibrillation (median duration: 4.5 months) were referred for external electrical cardioversion to our hospital. Mean left atrial diameter was 49 +/- 9 mm, heart disease was apparent in 81%. All patients were under antiarrhythmic drugs (class III: 85%). In 49 patients (91%) sinus rhythm was achieved. In five patients atrial fibrillation persisted after delivery of 360 Joules. These five patients were characterized by a significantly higher body weight in comparison to patients with successful external cardioversion. All five patients underwent low energy internal cardioversion the following day: biphasic R-wave synchronous shocks were delivered through catheters positioned in the right atrium and the coronary sinus using stepwise increased energy levels. Internal cardioversion was successful in all patients resistant to external cardioversion: stable sinus rhythm was established at a mean energy level of 13 +/- 6.7 Joules. No complications were observed. During the follow-up, each patient revealed a relapse of symptomatic atrial fibrillation within 2 weeks after internal cardioversion despite antiarrhythmic therapy, whereas only 16 patients (33%) lost sinus rhythm during the same period of time after external cardioversion (p < 0.01). During a mean follow-up of 283 +/- 72 days 21 patients (43%) preserved stable sinus rhythm after external cardioversion. Internal low energy cardioversion seems to be effective and safe in conversion of chronic atrial fibrillation resistant to external cardioversion. The clinical value of this invasive, time- and material-consuming therapy seems to be limited in this setting because of the high early relapse-rate in the investigated patient population. Further clinical studies in a larger cohort of patients are necessary.

Aged↗

Comparison of mortality from acute myocardial infarction in patients receiving anistreplase with those not receiving thrombolysis.

Within 1 year, 434 patients were admitted to 14 hospitals with suspected acute myocardial infarction (AMI) < or = 4 hours after the onset of symptoms. Group A consisted of 171 patients (39%) treated with thrombolysis, and group B consisted of 263 patients (61%) with contraindications. Patients in group A more likely had a "definite AMI" (92%; group A1) than patients in group B (67%; group B1). Group B1 had 277 contraindications (1.6/per patient) with increased risk for life-threatening bleeding being the most frequently recorded at admission. The in-hospital mortality in group A1 was 7% (11 of 158) and in group B1, 27% (47 of 177) (p < 0.0001). Age and type of therapy (thrombolysis or no thrombolysis) were identified as independent predictors of increased mortality (p < 0.0001 and < 0.05, respectively). Thus, although most patients with an AMI are excluded from thrombolytic therapy because of contraindications, our data suggest that their in-hospital mortality is unexpectedly high. Further evaluation of this group of patients is warranted to define the impact of contraindications as an independent factor of mortality.

Aged↗