Search PubMed⌕ Search

Biomedical subjects

H Sakahara

Publications and source records attributed to H Sakahara.

At least 19 recordsLinked to original sources

Ideographic characters call for extra processing to correspond with phonemes.

Cortical areas used in the copying of Japanese ideographic characters and syllabic characters were studied using functional magnetic resonance imaging in healthy volunteers. Complexity of characters was controlled to illustrate differences resulting from character to sound conversion differences between the ideographic and syllabic characters. Statistical comparisons indicated extensive activation in the fusiform gyrus, posterior portions around the intraparietal sulcus and in the conjunction area of BA 6, 9 and 44 (which is assumed to be Exner's area) during the copying of ideographic characters. These findings suggested that indirectness between ideographic characters and their pronunciation demands extra processing such as semantic mediation and intensive grapheme processing in comparison with syllabic characters.

Adult↗

Tumour enhancement with newly developed Mn-metalloporphyrin (HOP-9P) in magnetic resonance imaging of mice.

The purpose of the study is to evaluate the tumour enhancing characteristics and biodistribution of a newly developed metalloporphyrin derivative, HOP-9P (13, 17-bis (1-carboxypropionyl) carbamoylethyl-3, 8-bis (1-phenylpropyloxyethyl)-2,7,12,18-tetra- methyl-porphynato manganese (III)). Seven mice bearing SCC VII tumours were imaged using T1-weighted conventional spin echo magnetic resonance images before and 5 min, 2 h and 24 h after intravenous injection of 0.1 mmol/kg of HOP-9P. For the acquired images, signal intensities of the tumour, muscle and oil-phantom were measured. Then, tumor/oil and tumor/muscle signal intensity ratios were calculated. Nineteen mice were sacrificed before or after the administration of HOP-9P (at 5 min, 2 h and 24 h), and the biodistribution of manganese in the tumour, muscle, liver, blood and kidneys was measured using optical emission spectrometers and was expressed as micrograms of manganese per gram of tissue. The tumour/muscle signal intensity ratio at 24 h (3.18 +/- 0.34) was significantly higher than precontrast ratio (1.77 +/- 0.20) (P < 0.05). The biodistribution assessment of manganese demonstrated that HOP-9P gradually and consistently accumulated in the tumour to reach the highest concentration at 24 h (3.49 +/- 1.22 micro gMn/g). It is concluded that HOP-9P is a potential tumour-specific MR contrast agent.

Animals↗

T2-weighted MRI of the female pelvis: comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences.

In 49 patients who had pelvic abnormalities, breath-hold T2-weighted fast-recovery (FR)-fast spin-echo (FSE) (imaging time = 24 sec) and nonbreath-hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four-point scale) and quantitatively (using signal-to-noise ratios (SNRs) and contrast ratios (/SIs of the lesions-SIs of the myometrium/SIs of the myometrium)). Motion artifacts were reduced on breath-hold FR-FSE (3.8:3.2 = breath-hold FSE:nonbreath-hold FSE, P < 0.01) and image quality was comparable (3.8:3.7, NS). In all patients, pathology (leiomyoma [N = 26], adenomyosis [N = 10], endometrial carcinoma [N = 8], and ovarian cystic lesions [N = 21]) was recognized with comparable lesion conspicuity (3.8:3.7, NS) and better delineation of the structures (3.9:3.6, P < 0.05) on the FR-FSE images. There was no significant difference in contrast ratios, although SNRs (e.g., myometrium 18.3:25.8, P < 0.01) were better and the uterine zonal anatomy was recognized better on the nonbreath-hold FSE (3.4:3.7, P < 0.05). These differences did not affect the diagnosis. Breath-hold FR-FSE provides the benefits of motionless imaging and a short examination time, although lower SNRs were noted. J. Magn. Reson. Imaging 2001;13:930-937.

Adolescent↗

Fat-suppressed T2-weighted MRI of the liver: comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences.

The purpose of our study was to compare the value of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences in detecting hepatic lesions. Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the three sequences in 36 patients with 138 lesions and nine patients without lesions were prospectively analyzed. Quantitative and qualitative analyses, including receiver operating characteristic (ROC) analyses, were performed. The mean lesion-to-liver contrast-to-noise ratio (CNR) for hepatic lesions was highest with the respiratory-triggered fast spin-echo sequence. On the basis of receiver-operating characteristic analyses, tumor detection rates were higher with the breath-hold fast-recovery fast spin-echo sequence (Az = 0.94) than with the respiratory-triggered fast spin-echo sequence (AZ = 0.80, P < 0.0001) or the single-shot fast spin-echo sequence (Az = 0.77, P < 0.0001). The image quality with the breath-hold fast-recovery fast spin-echo sequence was acceptable in all patients. The breath-hold fast-recovery fast spin-echo sequence provided the highest tumor detection in a short imaging time, although the mean lesion-to-liver CNRs were inferior to those of the respiratory-triggered fast spin-echo and the breath-hold single-shot fast spin-echo sequences.

Adult↗

Functional assessment of pancreatic parenchyma after secretin administration using serial T2-weighted echo-planar magnetic resonance imaging.

Signal intensity (SI) changes of pancreatic parenchyma were evaluated after intravenous administration of secretin using T2-weighted single-shot spin-echo echo-planar imaging (EPI) to assess this method as a magnetic resonance (MR) test of pancreatic exocrine function. Nine volunteers were studied with serial single-shot EPI of the pancreas for 15 minutes after the injection of secretin or saline. The normal pattern of pancreatic SI change was demonstrated after intravenous injection of secretin, a single peak at 3-4 minutes in the head, body, and tail, followed by a gradual decrease in SI. Saline injection did not induce a significant SI change. There was no statistical difference in the peak contrast ratios (first mean, 1.21-1.25, vs. second mean, 1.18-1.22) and peak times (first mean, 3.2-3.7 minutes, vs. second mean, 3.1-3.6) in a repeat study. By evaluating the pattern of time-response curves obtained from serial T2-weighted EPI after secretin injection, pancreatic exocrine function may be directly assessed at the level of the head, body, and tail.

Adult↗

Dynamic gadolinium-enhanced MR imaging of pituitary adenomas: usefulness of sequential sagittal and coronal plane images.

Dynamic magnetic resonance (MR) imaging for pituitary adenomas is usually performed in a coronal direction; however, small lesions between slices, or lesions located at the anterior or posterior aspect of the pituitary gland might be overlooked on MR images in only the coronal direction. The purpose of our study was to evaluate whether consecutive dynamic MR images in the coronal and sagittal planes improve detection of pituitary adenomas. Eighteen patients with pituitary microadenomas and nine with healthy pituitary glands were included in this study. MR images were performed with 1.5 T superconductive units and commercially-available head coils. After a 5 ml gadolinium contrast injection, eight serial dynamic sagittal images were obtained. Within 3 or 6 min, this was followed by a 10-15 ml gadolinium injection and acquisition of eight serial dynamic coronal images. Dynamic MR images and conventional noncontrast- and contrast-enhanced sagittal and coronal T1-weighted images were evaluated independently in a blind fashion by two neuroradiologists regarding the depiction of pituitary microadenomas. The sensitivities of dynamic enhanced MR imaging in the detection of microadenomas were 61.1% in sagittal direction, 72.2% in coronal direction respectively, and were superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging (22.2-50%). The sensitivity of a combination of sagittal and coronal dynamic enhanced MR imaging for the detection of microadenomas was 88.9% and was superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging combining sagittal and coronal directions (61.1%, 61.1%) (P<0.05, P<0.05, respectively). The specificity and accuracy of dynamic enhanced MR imaging with combination of sagittal and coronal images was 88.9% respectively. Dynamic gadolinium-enhanced MR imaging, especially using both sagittal and coronal planes, was concluded to be useful for the detection of pituitary microadenomas.

Adenoma↗

Enhancement of the therapeutic outcome of radio-immunotherapy by combination with whole-body mild hyperthermia.

To enhance the effect of radio-immunotherapy for solid cancers, whole-body mild hyperthermia was added, and its effects on the pharmacokinetics of radiolabelled antibody, outcome of radio-immunotherapy, and radiosensitivity of the tumour were investigated. Nude mice bearing human colon cancer xenografts were heated to 40 degrees C for 3 or 6 h. After heating, mice received intravenous (i.v.) injections of [131I]-labelled anti-carcinoembryonic antigen (CEA) monoclonal antibody. Although 6-h heating did not alter the biodistribution of the radiolabelled antibody, and alone did not show any therapeutic effect on tumour growth, when combined with radio-immunotherapy, the therapeutic effect on tumour growth was significantly enhanced. Three-hour heating also significantly enhanced the effect of radio-immunotherapy. Colony formation assay showed that the radiosensitivity of the tumour was significantly enhanced after heating, which was achieved by a reduction of the hypoxic fraction of the tumour. In conclusion, the addition of whole-body mild hyperthermia significantly enhanced the therapeutic effect of radio-immunotherapy by increasing the radiosensitivity of the tumour.

Animals↗

Scintigraphic evaluation of small pulmonary right-to-left shunt and therapeutic effect in pulmonary arteriovenous malformation.

PURPOSE: Right-to-left shunts of pulmonary arteriovenous malformation (PAVM) can be detected and measured by pulmonary perfusion scans using Tc-99m MAA. In PAVM with a relatively small right-to-left shunt, however, measurement of the shunt ratio may not be reliable. This study re-evaluated pulmonary perfusion scans for a small right-to-left shunt of PAVM. METHODS: Tc-99m MAA lung scans were performed in five patients with proved PAVM before and after percutaneous transcatheter embolization. The right-to-left shunt ratio was calculated and extrapulmonary uptake was assessed on total-body images. RESULTS: Lung perfusion scans obtained before embolization revealed brain uptake in four patients, and the shunt ratio ranged from 4.4% to 22.9%. In two patients with a small single PAVM, the shunt ratio was less than 15% before treatment and did not change significantly after successful embolotherapy. The brain uptake, which had been clearly visible before therapy, disappeared after embolization. Renal uptake was seen on pre- and post-therapy scans. CONCLUSIONS: Changes in brain activity visible on Tc-99m MAA scans might be a more reliable sign than a decreased shunt ratio or a change in renal uptake when evaluating embolization therapy in patients with PAVM who have a small right-to-left shunt.

Adult↗

Changes in myometrial and junctional zone thickness and signal intensity: demonstration with kinematic T2-weighted MR imaging.

PURPOSE: To demonstrate uterine contractions by evaluating changes during time in the thickness of the myometrium and junctional zone and in signal intensity of the uterus with T2-weighted fast magnetic resonance (MR) images in a kinematic fashion. MATERIALS AND METHODS: Sagittal MR imaging was performed with T2-weighted fast spin-echo (FSE) and multiphase-multisection single-shot FSE (SSFSE) in 60 premenopausal patients during free breathing. SSFSE MR images were evaluated with cine display. The pattern of uterine contractions and changes in signal intensities of the uterine structures were evaluated. Thickness of both myometrium and junctional zone, and their signal intensities, were measured during 15 phases of SSFSE and FSE MR imaging. RESULTS: Slow-massive (mean, 55%), middle-cycle (mean, 80%), and fine (mean, 93%) contractions were observed. Shape of junctional zones dynamically changed during time, showing focal (mean, 58%) and diffuse (mean, 82%) thickening and wavelike motions (mean, 88%). Ratio of thickness of the myometrium to junctional zone with FSE MR imaging was not significantly different from the mean ratio during 15 phases of SSFSE MR imaging, although maximum percentage of change of the ratio during 15 phases was 42.5%-56.8%. The signal intensities of the myometrium (97%) and junctional zone (75%) changed during time. CONCLUSION: Kinematic T2-weighted SSFSE MR images demonstrate uterine contractions related to dynamic changes in thickness and signal intensities of the myometrium and junctional zone, and these findings might affect the diagnosis of uterine disease.

Adolescent↗

Assessment of gadolinium-enhanced time-resolved three-dimensional MR angiography for evaluating renal artery stenosis.

OBJECTIVE: The purpose of this study was to assess the image quality of gadolinium-enhanced time-resolved three-dimensional (3D) MR angiography and to evaluate its accuracy in revealing renal artery stenosis. SUBJECTS AND METHODS: Thirty-nine patients underwent MR angiography using an ultrafast 3D Fourier transform spoiled gradient-recalled acquisition in the steady state (TR/TE range, 2.6/0.7--0.8). Five seconds after administration of 15--20 mL gadodiamide hydrate, four or five consecutive data sets with imaging times of 7.0--7.6 sec were acquired during a single breath-hold. A timing examination was not performed. Image quality was assessed using quantitative analysis (signal-to-noise, contrast-to-noise, and venous-to-arterial enhancement ratios) and qualitative analysis (presence of venous overlap, presence of artifacts, and degree of renal arterial enhancement). MR angiography depiction of the renal artery stenosis was evaluated using conventional angiography as the standard of reference. RESULTS: On the best arterial phase, average aortic signal-to-noise ratio (+/-SD) was 74.5 +/- 24.4, aorta-to--inferior vena cava contrast-to-noise ratio was 70.8 +/- 23.4, and inferior vena cava--to-aorta venous-to-arterial enhancement ratio was 0.03 +/- 0.04. No venous overlap was seen in 38 of 39 patients. Substantial enhancement of renal arteries was seen in all patients without any noticeable artifacts. MR angiography correctly depicted the degree of stenosis in 44 of 47 normal arteries, 13 of 16 mildly stenotic arteries, five of five moderately stenotic arteries, three of four severely stenotic arteries, and one of one occluded artery. Sensitivity and specificity for revealing greater than 50% stenosis was 100%. CONCLUSION: Time-resolved 3D MR angiography can provide high-quality arteriograms. Its performance in revealing renal artery stenosis is comparable with that of conventional angiography.

Adult↗

Clinical value of positron emission tomography with FDG for recurrent ovarian cancer.

OBJECTIVE: Recurrence is often a major problem for patients who have undergone surgery for ovarian cancer. This prospective study was undertaken to evaluate the clinical contribution of positron emission tomography (PET) using (18)F-fluorodeoxyglucose (FDG) for recurrent ovarian cancer. SUBJECTS AND METHODS: Twenty-four women who had undergone surgery or chemoradiotherapy for histopathologically proven ovarian cancer were enrolled in this study. Ovarian cancer was thought to have recurred in 12 of these women because of evidence on conventional imaging modalities or tumor marker measurements (group A). Clinical findings for the remaining 12 women showed them to be disease-free (group B). PET findings for the women were compared with the final diagnoses obtained by histopathology or by clinical follow-up. The clinical contribution of PET was assessed by evaluating whether PET yielded information complementing the findings of conventional modalities and by examining its impact on treatment. RESULTS: PET gave valuable information for seven of 12 patients in group A in addition to the information obtained from findings on conventional imaging, and treatment was affected in five patients. On the other hand, in group B, additional information was obtained in only three of 12 patients, and treatment of only one patient was affected. Overall sensitivity, specificity, and accuracy of conventional imaging modalities were 72.7%, 75.0%, and 73.3%, respectively, and these rates improved to 92.3%, 100.0%, and 94.4%, respectively, by considering both conventional imaging modalities and PET findings. CONCLUSION: Our preliminary data suggest that whole-body PET with FDG can be a complementary modality for following up patients who have had ovarian cancer, especially patients believed to be at risk for recurrence.

Case-Control Studies↗

Evaluation of pelvic adhesions using multiphase and multislice MR imaging with kinematic display.

OBJECTIVE: The purpose of this study was to evaluate whether kinematic multiphase and multislice MR imaging could reveal pelvic adhesions. SUBJECTS AND METHODS: Before surgery, 52 women with gynecologic disorders underwent half-Fourier acquisition single-shot fast spin-echo imaging with multiphase and multislice acquisitions. Images were displayed in a cine mode, and the motion of each organ against adjacent organs was evaluated by two radiologists who were unaware of the patients' histories or of the findings of their clinical examinations or surgeries. Findings from MR imaging were classified into three types relative to the adjacent organs: type 1, sliding, defined as organs moving 1 cm or more; type 2, fine motion, defined as organs moving less than 1 cm; or type 3, no motion. Type 2 was further subdivided into two groups: type 2-A, independent fine movement, and type 2-B, synchronous fine movement. All MR imaging findings were verified by laparotomy or laparoscopy. Peristalsis at the rectum, colon, and small intestine were also evaluated. RESULTS: A total of 317 interfaces were evaluated. For findings of type 1 (n = 8 interfaces) and type 2-A (n = 245) on kinematic MR imaging, the negative predictive values for adhesions were 100% and 95.5%, respectively. Findings of type 2-B (n = 52) and type 3 (n = 12) with no adhesions were observed in 40.4% and 66.7%, respectively. When type 1 and type 2-A were regarded as negative findings of adhesions, and type 2-B and type 3 as positive, sensitivity, specificity, and accuracy were 72.5%, 87.4%, and 85.4%, respectively. Peristalsis was observed in 69.2% of patients at the rectum, 86.5% at the colon, and 100% at the small intestine. CONCLUSION: Multiphase and multislice MR imaging with kinematic display may provide new information about the presence of pelvic adhesions.

Adolescent↗

Delayed (18)F-fluoro-2-deoxy-D-glucose positron emission tomography scan for differentiation between malignant and benign lesions in the pancreas.

BACKGROUND: Positron emission tomography (PET) using (18)F-fluoro-2-deoxy-D-glucose (FDG) has been used for the evaluation of various tumors, but accumulation in inflammatory lesions makes it a controversial modality. The aim of this study was to investigate the usefulness of delayed scanning in differentiation between malignant and benign lesions in the pancreas. METHODS: Forty-seven patients with suspected pancreatic carcinoma were studied by FDG-PET. All patients received approximately 370 megabequerels of FDG after a transmission scan, and an emission scan was performed 1 hour and 2 hours later for all patients. A subset of 19 patients was also scanned at 3 hours postinjection. The standardized uptake value (SUV) was determined, and the retention index was calculated by dividing the increase in the SUV between 1 hour and 2 hours postinjection by the SUV at 1 hour postinjection. RESULTS: Of 27 malignant lesions, the SUVs of 22 lesions increased at 2 hours postinjection, whereas the FDG uptake in 17 of 20 benign lesions decreased. The SUVs at 3 hours postinjection were higher than those at 2 hours postinjection in 9 of 14 malignant lesions and in 2 of 5 benign lesions. Malignant lesions showed a higher retention index than benign lesions (mean +/- standard deviation: 12. 36 +/- 13.37 and -7.05 +/- 17.28, respectively; P < 0.0001). Applying an SUV of 2.5 at 1 hour postinjection with the cut-off value for the differentiation between malignant and benign lesions caused one false negative result and seven false positive results, with a diagnostic accuracy of 83.0% (39 of 47 patients). However, combining the retention index with the SUV obtained at 2 hours postinjection provided a higher diagnostic accuracy (91.5%; 43 or 47 patients) than the SUV alone. The false negative rate remained constant when the retention index was taken into account. Images at 3 hours postinjection usually were unhelpful in differentiating further between malignant lesions and benign lesions. CONCLUSIONS: The current data suggest that delayed FDG-PET scanning at 2 hours postinjection may contribute to differentiation between malignant and benign lesions in the pancreas.

Adult↗

The effects of listening comprehension of various genres of literature on response in the linguistic area: an fMRI study.

Using fMRI at a static magnetic field strength of 1.5T, we investigated how comprehension and humor of sentences would correlate to activation of the language areas in listening comprehension of a native language. Sentences with a high comprehension score augmented activation in the left inferior parietal lobule and posterior part of the left superior temporal gyrus, which may be related to semantic processing. Sentences with a high humor score induced activation in Broca's area, which may be associated with syntactic processing and auditory working memory. Furthermore, sentences with a high humor factor and/or a low comprehension score activated the middle frontal gyrus, which may be attributed to auditory working memory.

Adult↗

Gadolinium-enhanced MR angiography in the evaluation of congenital cardiovascular disease pre- and postoperative states in infants and children.

The purpose of this study was to evaluate the utility of dynamic contrast magnetic resonance (MR) angiography under sedation for assessing congenital cardiovascular disease in infants and small children before and after cardiac surgery. In 38 patients with cardiovascular abnormalities, thoracic vasculatures were evaluated in either the preoperative (group 1; 23 patients, median age 9 months old) or the postoperative (group 2; 15 patients median age 1. 3 years old) state using gadolinium-enhanced dynamic MR angiography. Acquired data were processed with a multiprojection volume reconstruction. Image quality (grades 1-5, undiagnostic to excellent), presence or absence of the extracardiac vasculature, its pathology (group 1), and the patency of the postsurgical shunt or reconstructed vasculature (group 2) were evaluated. All images were of diagnostic image quality (mean grade 4.4-3.2). Recognition of the thoracic vasculature was correctly made in all cases (38/38, 100%). In group 1, anomalies and pathologic changes were correctly identified in 22 of 23 cases (95.7%). In one patient with dextrocardia and the cardiac type of total anomalous pulmonary venous return, the abnormality was not recognized. In group 2, the patency of the shunt flow after Glenn (n = 6), modified Fontan (n = 4), Rastelli (n = 1), and Blalock-Taussig (n = 3) operations was well demonstrated in each case. The reconstructed pulmonary artery (n = 1), veins (n = 2), and aorta (n = 1) were correctly visualized. In one case, stenosis of the reconstructed left pulmonary vein was missed by MR angiography. In 14 of 15 cases in group 2 (93.3%), MR angiography correctly gave information on the operated areas. In conclusion, dynamic contrast MR angiography under sedation is useful for evaluation of the thoracic vasculature of infants and small children in the pre- and postoperative states. J. Magn. Reson. Imaging 2000;12:1034-1042.

Aortography↗

FDG-PET of autoimmune-related pancreatitis: preliminary results.

The purpose of this retrospective study was to elucidate the fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) findings in autoimmune-related pancreatitis (AIP), which is a reversible chronic pancreatitis with an autoimmune cause. The study group comprised six patients with clinically diagnosed AIP. After 370 MBq (10 mCi) of FDG had been injected intravenously, the abdomen and/or the whole body was scanned at 1 h post injection in all patients, and scanning was repeated at 2 h in four patients. PET findings were evaluated visually and/or semiquantitatively using the standardized uptake value (SUV). In four of the six patients, PET demonstrated intense uptake in the whole pancreas, which appeared swollen on computed tomography, and the accumulation increased with time in three patients. In one patient, intense focal uptake in the pancreatic head was observed, and the accumulation decreased over time. In the remaining patient, no abnormal accumulation in the pancreas was observed. Follow-up PET scanning after steroid therapy was performed in three patients, and intense FDG uptake was no longer observed. Our preliminary data show that AIP can cause intense FDG uptake in the pancreas. This fact, and the benign status of the condition, should be kept in mind when making a diagnosis with FDG-PET in patients with pancreatic disorders.

Cell Survival↗

Post-stimulus response in hemodynamics observed by functional magnetic resonance imaging--difference between the primary sensorimotor area and the supplementary motor area.

The blood oxygen level dependency (BOLD) contrast is a useful tool for functional neuroimaging based on the hemodynamic response to neuronal activation. We observed different hemodynamic responses in the BOLD signal between the primary sensorimotor area (SM1) and the supplementary motor area (SMA) in the sequential finger movement task. In the SMA, a stronger initial overshoot and a post-stimulus overshoot were observed. It was hypothesized from the time course analysis that the stronger initial overshoot reflected the activation of the SMA for motor control programming in the initial phase. Although the post-stimulus overshoot may be partially explained by cerebral blood flow (CBF) cerebral blood volume (CBV) uncoupling, its mechanism remained unknown. In the SM1, only the initial overshoot was observed and the level of BOLD signal was almost constant after the initial overshoot during the task period. These observations suggested that the BOLD signal is characterized by both CBF-CBV uncoupling and the neuronal activation characteristics in each region.

Adult↗

Dissociation of writing processes: functional magnetic resonance imaging during writing of Japanese ideographic characters.

Dissociation between copying letters and writing to dictation has been reported in the clinical neuropsychological literature. Functional magnetic resonance imaging (fMRI) was conducted in normal volunteers to detect the neurofunctional differences between 'copying Kanji', the Japanese ideographic characters, and 'writing Kanji corresponding to phonological information'. Four tasks were conducted: the copying-Kanji task, the writing-Kanji-corresponding-to-phonogram task, the Kanji-grapheme-puzzle task, and the control task. The right superior parietal lobule was extensively activated during the copying-Kanji task (a model of the copying letters process) and the Kanji-grapheme-puzzle task. These observations suggested that this area was involved in referring the visual stimuli closely related to the ongoing handwriting movements. On the other hand, Broca's area, which is crucial for language production, was extensively activated during the writing-Kanji-corresponding-to-phonogram task (a model of the writing-to-dictation process). The Kanji-grapheme-puzzle task activated the bilateral border portions between the inferior parietal lobule and the occipital lobe, the left premotor area, and the bilateral supplementary motor area (SMA). Since the Kanji-grapheme-puzzle task involved manipulospatial characteristics, these results suggested cooperation between visuospatial and motor executive functions, which may be extensively utilized in demanding visual language processing. The neurofunctional difference between 'copying Kanji' and 'writing Kanji corresponding to phonogram' was efficiently demonstrated by this fMRI experiment.

Adult↗