Search PubMed⌕ Search

Biomedical subjects

H S Thomsen

Publications and source records attributed to H S Thomsen.

At least 19 recordsLinked to original sources

Magnetic resonance investigation of bone marrow following priming and stem cell mobilization.

PURPOSE: To evaluate application of MRI and magnetic resonance spectroscopy (MRS) to monitor bone marrow cellularity during pretransplant priming with chemotherapy and hematopoietic growth factor (HGF) administration. MATERIALS AND METHODS: A total of 10 lymphoma and myeloma patients, in remission following induction therapy and considered eligible for high-dose therapy and autologous stem cell transplantation, were included in the study. MR investigation was scheduled four times: at study entry, and one, two, and four weeks following priming. Priming with cyclophosphamide and recombinant human granulocyte colony-stimulating factor (rhG-CSF) started the day after study entry. MR parameters studied in a region of interest were as follows: bone marrow intensity on short-time inversion-recovery (STIR) turbo spin-echo (TSE; thus STIRTSE) and on T1-weighted TSE (T1TSE) images, T2 value for fat component, T2 value for water component, water/fat ratio (W/F), T1 value for fat component, and T1 value for water component. RESULTS: The results did not support the hypothesis that hematopoietic expansion quantitated and monitored by MR correlates to the level of mobilized progenitor cells. CONCLUSION: The results indicate that release of stem cells is a more complex phenomenon than hematopoietic expansion and reduction of fat tissue in bone marrow.

Aged↗

Magnetic resonance imaging for accelerated assessment of drug effect and prediction of subsequent radiographic progression in rheumatoid arthritis: a study of patients receiving combined anakinra and methotrexate treatment.

OBJECTIVES: By MRI to assess the efficacy of addition of anakinra for controlling synovitis and stopping erosive progression in patients with clinically active RA despite receiving methotrexate, and to determine the predictive value of MRI for subsequent radiographic erosive progression. METHODS: 100 mg anakinra subcutaneously/day was added to the treatment of 17 patients with clinically active RA despite methotrexate. MRI of the non-dominant wrist and 2nd-5th MCP joints (OMERACT evaluation) was performed at weeks 0, 12, and 36, and radiography of both hands and wrists (modified Sharp evaluation) at weeks 0 and 36. RESULTS: MRI synovitis scores were not significantly changed. Radiography of both hands and wrists after 36 weeks showed erosive progression in 11 patients, and MRI after 12 weeks in 10 patients. Nine of 10 patients with MRI progression at 12 weeks had radiographic progression at 36 weeks. Baseline MRI synovitis and erosion scores, but no clinical/biochemical parameters, correlated significantly with subsequent erosive progression. CONCLUSION: Addition of anakinra did not significantly reduce MRI signs of synovitis, and most patients had progressive joint destruction. Baseline MRI findings predicted subsequent radiographic erosive progression. Unilateral wrist and MCP joint MRI after 12 weeks had a similar sensitivity for detection of erosive progression as bilateral hand and wrist radiography after 36 weeks.

Adult↗

Optimised, low cost, low field dedicated extremity MRI is highly specific and sensitive for synovitis and bone erosions in rheumatoid arthritis wrist and finger joints: comparison with conventional high field MRI and radiography.

OBJECTIVE: To evaluate a low field dedicated extremity MRI unit for detection of bone erosions, synovitis, and bone marrow oedema in wrist and metacarpophalangeal (MCP) joints, with a high field MRI unit as the standard reference. METHODS: In 37 patients with RA and 28 healthy controls MRI of the wrist and 2nd-5th MCP joints was performed on a low field MRI unit (0.2 T Esaote Artoscan) and a high field MRI unit (1.0 T Siemens Impact) on 2 subsequent days. MRI was performed and evaluated according to OMERACT recommendations. Additionally, conventional x ray, clinical, and biochemical examinations were performed. In an initial low field MRI "sequence selection phase", based on a subset of 10 patients and 10 controls, sequences for comparison with high field MRI were selected. RESULTS: With high field, spin echo MRI considered as the reference method, the sensitivity, specificity, and accuracy of low field 3D gradient echo MRI for erosions were 94%, 93%, 94%, while the corresponding values for x ray examination were 33%, 98%, and 83%. Sensitivity, specificity, and accuracy of low field MRI for synovitis were 90%, 96%, and 94%, and for bone marrow oedema 39%, 99%, and 95%. Intraclass correlation coefficients between low field and high field scores were 0.936 (p<0.005) for bone erosions and 0.923 (p<0.05) for synovitis. CONCLUSION: Low field MRI provides high accuracy for detection and grading of erosions and synovitis, with high field MRI as the standard reference. For bone marrow oedema, specificity is high, but sensitivity only moderate. Low cost, patient compliant, low field dedicated extremity MRI provides similar information on bone erosions and synovitis as expensive high field MRI units.

Adult↗

Effect of new manganese contrast agent on tissue intensities in human volunteers: comparison of 0.23, 0.6 and 1.5 T MRI, a part of a phase I trial.

To evaluate the effect of a new oral manganese contrast agent (CMC-001) on magnetic resonance imaging (MRI) intensities at different magnetic field strengths. Twelve healthy volunteers underwent abdominal MRI 1 week before and within 2.5-4.5 h after CMC-001 (MnCl(2) and absorption promoters dissolved in water) intake at three different MR scanners of 0.23, 0.6 and 1.5 T. Image contrast and intensity enhancement of liver and pancreas were analysed relatively to muscle and fat intensities. Manganese blood levels were followed for 24 h. Whole-blood manganese concentration levels stayed within the normal range. The liver intensities on T2w images decreased about 10% for the 1/2 contrast dose and about 20% for the full contrast dose independent of the field strength. The liver intensities on T1w images increased more than 30% for 1/2 contrast dose and over 40% for full contrast dose. The maximum T1 enhancement was achieved at the highest field. Pancreas intensities were not affected. Contrast between liver, muscle and fat intensities increased with magnetic field, as well as standard errors of the volunteer-averaged intensities. Oral intake of CMC-001 influences liver intensities and does not affect pancreas intensities at different magnetic field strengths.

Abdomen↗

Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines.

The Contrast Media Safety Committee of the European Society of Urogenital Radiology (ESUR) has looked at the effects of contrast media on the kidney including prevention of contrast medium induced nephropathy. This has resulted in four reports dealing with 1) contrast medium induced nephrotoxicity, 2) haemodialysis and contrast media, 3) use of gadolinium contrast media instead of iodinated contrast media and 4) contrast media injection in diabetic patients receiving metformin. The review presents an overview of these four reports and offers the current understanding of the interaction between contrast agents and the kidney.

Biomarkers↗

Contrast medium extravasation injury: guidelines for prevention and management.

Extravasation of contrast material is a well-recognized complication of contrast-enhanced imaging studies. The management of this complication is contentious; therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and issue guidelines. A comprehensive literature search was carried out. The resulting report was discussed at the 8th European Symposium on Urogenital Radiology in Genoa, Italy. Automated power injection may result in extravasation of large volumes and may or can lead to severe tissue damage. Infants, young children and unconscious and debilitated patients are particularly at risk of extravasation during contrast media injection. Fortunately, most extravasations result in minimal swelling or erythema, with no long-term sequelae; however, severe skin necrosis and ulceration may occur. Large volumes of high osmolar contrast media are known to induce significant tissue damage. Compartment syndrome may be seen associated with extravasation of large volumes. Conservative management is often adequate, but in serious cases the advice of a plastic surgeon is recommended. Based on the review simple guidelines for prophylaxis and management of contrast medium extravasation injuries are proposed.

Adult↗

Clinical decision making in the acutely injured knee based on repeat clinical examination and MRI.

To determine the correlation between Magnetic Resonance Imaging (MRI) and clinical examination of the knee after an acute injury, and to see to what extent MRI affected the planned treatment, we examined 90 consecutive patients in a prospective study, clinically and with an extremity Magnetic Resonance (MR) scanner. The number of meniscal lesions, bone bruises and osteochondral lesions found on MRI was significantly higher than the clinical examinations indicated. Despite this, the treatment was only changed in 6 cases. In no case did MRI prevent a planned arthroscopy. MRI may reveal many clinically silent changes in the knee, also after minor injuries. The significance of these MRI findings must await long-term follow-up.

Acute Disease↗

Inflammatory bowel disease evaluated by low-field magnetic resonance imaging. Comparison with endoscopy, 99mTc-HMPAO leucocyte scintigraphy, conventional radiography and surgery.

BACKGROUND: To evaluate the use of low-field magnetic resonance imaging (MRI) in active inflammatory bowel disease (IBD). METHODS: MRI was executed in a consecutive cohort of 28 patients with Crohn disease (CD) and in 17 with ulcerative colitis (UC) prior to glucocorticoid treatment (1 mg prednisolone orally/kg body weight/day). MRI was repeated after 2-3 weeks (22 CD, 12 UC), and again after treatment completion or prior to surgery (18 CD, 6 UC). Five bowel segments were evaluated separately. MRIs were blindly evaluated by two observers, and findings compared with 39 leucocyte scintigraphies, 38 endoscopies, 15 double-contrast barium enemas, 66 small-bowel radiographic examinations and surgery in 23 patients. RESULTS: In CD, blinded evaluation revealed a kappa (kappa) of 0.84 (95% confidence interval (CI) 0.78-0.91). In UC, kappa was 0.66 (95% CI 0.55-0.78). Agreements regarding disease extension between MRI and other modalities in CD were found in 345 bowel segments out of 391 (88.2%) at risk, and in UC in 209/235 (88.9%). Colonic disease activity gradings by radiography and endoscopy correlated significantly with T2-signal intensity (SI(T2)) and increments in T1-signal intensity (%SI(T1)) in both diseases. Significant correlations between MRI indices of disease activity and CDAI in CD (MRI-SI(T2): P <0.0001: MRI% SI(T1): P=0.0008) and the Powell-Tuck index in UC (MRI% SI(T1): P=0.008) were found. CONCLUSIONS: With low interobserver variation and high concordance of findings with other examinations. low-field MRI seems a valuable modality in active IBD. In addition, MRI expressions of disease activity correlate to clinical, radiographic and endoscopic disease activity.

Adult↗

MRI of the arthritic small joints: comparison of extremity MRI (0.2 T) vs high-field MRI (1.5 T).

The aim of this study was to compare the diagnostic capabilities of extremity MRI (E-MRI) with high-field MRI in arthritic small joints, and to evaluate the patients' acceptance and perceptions of the two MR systems. One hundred three patients (group 1 = 28 patients with RA < 3 years, group 2 = 25 patients with reactive and psoriatic arthritis and mixed connective tissue disease, group 3 = 25 patients with rheumatoid arthritis (RA) more than 3 years and group 4 = 25 patients with arthralgia) underwent dedicated E-MRI and high-field MRI of the wrist and finger joints. Coronal short tau inversion recovery and transversal 3D T1-weighted images before and after gadodiamide (Gd) were performed in both cases to outline the volume of the synovial membrane (Vsm) and to evaluate joints with enhancement, effusion, bone edema, and erosions. Investigators blinded to the clinical findings evaluated the images. Patients' compliance and acceptance of E-MRI and high-field MRI were evaluated. The median Vsm obtained on E-MRI did not differ significantly from that obtained on high-field MRI. Vsm = 1 ml (E-MRI) and 1.1 ml (high-field MRI) before Gd and Vsm = 0.1 ml (E-MRI) and 0 ml (high-field MRI) after Gd (Wilcoxon test, p > 0.05). The difference in agreement was 8% for joint enhancement, 2% for joint effusion, 3% for bone edema, and 4% for bone erosions. Of the patients, 64% preferred E-MRI due to more comfortable positioning and less claustrophobia and noise. Extremity MRI of the small arthritic joints is comparable to high-field MRI and more readily accepted than high-field MRI by this patient group.

Adult↗

Adverse reactions to iodinated contrast media.

Adverse reactions to iodinated contrast media (ICM) are more likely to develop in patients with asthma, a history of allergy or contrast reaction and in those who are debilitated or medically unstable. These reactions can be divided into renal and general, and the latter are subdivided into acute and delayed. Acute general reactions can be minor, intermediate or severe. Fatal reactions are rare. The introduction of low-osmolality agents has caused an overall reduction in the number of non-fatal contrast reactions. Prompt recognition and treatment of acute adverse side effects to ICM is invaluable and may prevent a reaction from becoming severe. Familiarity with cardiopulmonary resuscitation is essential for successful management of life-threatening reactions. Contrast-media-induced renal impairment can be reduced with the use of low-osmolality contrast media and extracellular volume expansion. The use of ICM in diabetic patients receiving metformin should be carried out with care to avoid metformin-induced lactic acidosis. However, this problem is mainly observed in patients with diabetic nephropathy.

Acidosis, Lactic↗

Prevention of generalized reactions to contrast media: a consensus report and guidelines.

The aim of this study was to document, using consensus methodology, current practice for prevention of generalized reactions to contrast media, to identify areas where there is disagreement or confusion and to draw up guidelines for reducing the risk of generalized contrast media reactions based on the survey and a review of the literature. A document with 165 questions was mailed to 202 members of the European Society of Urogenital Radiology. The questions covered risk factors and prophylactic measures for generalized contrast media reactions. Sixty-eight members (34%) responded. The majority indicated that a history of moderate and severe reaction(s) to contrast media and asthma are important risk factors. The survey also indicated that patients with risk factors should receive non-ionic contrast media. In patients at high risk of reaction, if the examination is deemed absolutely necessary, a resuscitation team should be available at the time of the procedure. The majority (91%) used corticosteroid prophylaxis given at least 11 h before contrast medium to patients at increased risk of reaction. The frequency of the dosage varied from one to three times. Fifty-five percent also use antihistamine Hl, mainly administered orally and once. Antihistamine H2 and ephedrine are rarely used. All essential drugs are available on the emergency resuscitation trolley. Patients with risk factors are observed up to 30 min by 48% and up to 60 min by 43% of the responders. Prophylactic measures are not taken before extravascular use of contrast media. Prophylactic drugs are given to patients with a history of moderate or severe generalized reaction to contrast media. In patients with asthma, opinion is divided with only half of the responders giving prophylactic drugs. Aspirin, beta-blockers, interleukin-2 and non-steroid anti-inflammatory drugs are not considered risk factors and therefore are not stopped before injection of contrast media. The survey showed some variability in rating of risk factors for generalized contrast medium reactions, and marked variability in the prophylactic measures used. There remain major areas of uncertainty, and there is insufficient data in the literature to guide practice. Some simple guidelines for prophylaxis of generalized contrast medium reactions are proposed.

Contrast Media↗

Magnetic resonance imaging of the wrist and finger joints in patients with inflammatory joint diseases.

OBJECTIVE: To study magnetic resonance imaging (MRI) features in the wrist and metacarpophalangeal (MCP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints in 4 patient groups: early rheumatoid arthritis (RA) (< 3 yrs); established RA (> 3 yrs); other arthritis; arthralgia. METHODS: MRI was obtained before and after contrast (gadodiamide) injection of the wrist and finger joints in 103 patients and 7 controls. The study included: (1) 28 patients with disease duration < 3 yrs who fulfilled the American College of Rheumatology (ACR) criteria for RA; (2) 25 patients with RA disease duration > 3 yrs who fulfilled the ACR criteria. (3) 25 patients with reactive arthritis, psoriatic arthritis, or mixed connective tissue disease; and (4) 25 patients with arthralgia. The following MRI variables were assessed: number of joints with enhancement after contrast injection, number of joints with joint fluid, and number of bones with edema in the wrist and fingers. The volume of the enhancing synovial membrane after contrast injection in the MCP, PIP, and DIP joints was manually outlined. MR images were scored independently under blinded conditions. RESULTS: Bone marrow edema was found in 68% of the patients with established RA, and the number of bones with edema was significantly higher in patients with established RA compared to patients with early RA, other arthritis, and arthralgia (Mann-Whitney p < 0.04). Bone edema was not found in patients with arthralgia. There was marked overlap within and between the patient groups. No differences in MRI features were found between patients with early RA and patients with other arthritis. The volumes of the synovial membrane in the MCP, PIP, and DIP joints were significantly higher in patients with arthritis compared to patients with arthralgia. CONCLUSION: Although there was marked overlap between the arthritis patient groups, MRI determined bone marrow edema and synovial membrane volumes provided additional information about disease activity and may be used as a marker of it. Bone marrow edema appeared with the highest percentage in patients with long duration of RA (> 3 yrs) and is probably secondary to changes in inflammatory activity.

Acute-Phase Proteins↗

Behavior of the graft within the bone tunnels following anterior cruciate ligament reconstruction, studied by cinematic magnetic resonance imaging.

The behavior of a ligament graft following cruciate ligament reconstruction is still an area of limited knowledge. Cinematic magnetic resonance imaging (MRI) offers the possibility of visualizing the graft, including the graft tunnels and fixation during knee motion. Twenty-three patients underwent cinematic MRI (0. 2 T; Artoscan) mean 23.4 months (range 14-39 months) after autologous anterior cruciate ligament reconstruction (eight bone-tendon-bone, seven semitendinosus-gracilis, and eight iliotibial band). The images were read without knowledge of the clinical condition or the type of surgery performed. Signal intensity and continuity of the anterior cruciate ligament reconstruction and movement of the graft in the tibial or femoral tunnel anteriorly and posteriorly were noted. In two of the 23 patients the graft (semitendinosus-gracilis) moved in the tibial canal. The initial 9-mm tunnel had expanded by 2 mm in the anteroposterior direction at the entrance to the joint space. Only these two had a slight knee laxity, with a side-to-side difference in anterior translation measured by the KT-2000 of 4 and 5 mm. No movement was observed in any of the femoral tunnels. Cinematic MRI thus makes it possible to study graft behavior within the bone tunnels.

Anterior Cruciate Ligament↗

Quantification of gadodiamide as Gd in serum, peritoneal dialysate and faeces by inductively coupled plasma atomic emission spectroscopy and comparative analysis by high-performance liquid chromatography.

An inductively coupled plasma atomic emission spectroscopy (ICP-AES) method for determination of gadodiamide as Gd in serum, peritoneal dialysate and faeces was developed. The within-day and between-day precision for determination of Gd in serum and peritoneal dialysate were 0.60-2.9 and 1.8-4.4%, respectively, and the accuracy was 98.0-99.3%. The quantification limits in serum and peritoneal dialysate were 6.5 and 1.6 microM Gd, respectively. The within-day and between-day precision determination of gadolinium in faeces were 1.0-5.3 and 2.2-7.9%, respectively, and the accuracy was 104-116%. The quantification limit was 11 nmol Gd/g dry weight. For the high-performance liquid chromatography (HPLC) method, the within-day precision in determination of gadodiamide in peritoneal dialysate was 1.2% and the accuracy was 103%. The quantification limit was 0.9 microM Gd. Comparative analysis of gadodiamide in serum and peritoneal dialysate from severely impaired renal patients by ICP-AES and HPLC revealed no metabolism of chelator or transmetallation of gadolinium, even in samples obtained as long as 7 days after dosing. Furthermore, the ICP-AES determination of Gd in faeces allows for the determination of faeces content of Gd corresponding to less than 0.1% of a clinical dosage of a Gd-based contrast medium.

Chromatography, High Pressure Liquid↗

Staging uterine cervical carcinoma with low-field MR imaging.

PURPOSE: To assess the validity of low-field MR in staging cervical cancer compared to clinical staging. MATERIAL AND METHODS: A total of 95 women entered the study over a 3-year period. MR examinations with a 0.1 T resistive magnet using a body coil and clinical staging according to the FIGO recommendations (1988) were performed within 2 weeks from clinical diagnosis. T1- and T2-weighted sequences were obtained in transversal and sagittal acquisitions, and an additional T1 before and after contrast (randomisation to 0.1 or 0.3 mmol/kg b.w. gadodiamide). Treatment decisions on surgery or radiation therapy were made solely on the clinical staging. RESULTS: Sixty-one patients were found to be eligible for surgery. In 5 women, the pathological results revealed a more advanced stage of the disease than assessed by clinical staging. MR correctly staged 4 of the 5 but otherwise tended to overstate the disease. Contrast enhancement significantly reduced this trend (p<0.05) regardless of the contrast medium dose used. Divided into two groups, an operable (less than stage 2b) and an inoperable group (more than stage 2a), the clinical staging correctly classified 57 patients (accuracy 92%) compared to 52 patients with MR using contrast enhancement (accuracy 84%). The specificity was no higher than 31%, whereas the reproducibility of the MR assessment was fairly good with kappa values around 0.65 for both intra- and inter-observer variations. CONCLUSION: In the present set-up, clinical assessment was superior to low-field MR in staging cervical cancer. When using contrast enhancement, the staging accuracies of low-field MR were comparable to the ones reported for techniques with higher tesla values, whereas the specificity and reproducibility errors were lower. The method, therefore, needs to be optimised.

Adenocarcinoma↗