Search PubMed⌕ Search

Biomedical subjects

H S Markus

Publications and source records attributed to H S Markus.

At least 37 records · Page 2Linked to original sources

Atrial natriuretic peptide gene G664A polymorphism and the risk of ischemic cerebrovascular disease.

The atrial natriuretic peptide (ANP) gene may underlie stroke susceptibility and sensitivity to cerebral ischemia in an animal model of stroke. The authors investigate its role in humans by genotyping a polymorphism (G664A) in 436 patients with ischemic cerebrovascular disease and 295 community control subjects. The frequency of this variant was similar in both groups and across the different stroke subtypes. The ANP gene G664A polymorphism is therefore unlikely to be an important risk factor for ischemic stroke in this population.

Aged↗

Evidence for cortical "disconnection" as a mechanism of age-related cognitive decline.

BACKGROUND: Normal aging is accompanied by a decline of cognitive abilities, and executive skills may be affected selectively, but the underlying mechanisms remain obscure and preventive strategies are lacking. It has been suggested that cortical "disconnection" due to the loss of white matter fibers may play an important role. But, to date, there has been no direct demonstration of structural disconnection in humans in vivo. METHODS: The authors used diffusion tensor MRI to look for evidence of ultrastructural changes in cerebral white matter in a group of 20 elderly volunteers with normal conventional MRI scans, and a group of 10 younger controls. The older group also underwent neuropsychological assessment. RESULTS: Diffusional anisotropy, a marker of white matter tract integrity, was reduced in the white matter of older subjects and fell linearly with increasing age in the older group. Mean diffusivity was higher in the older group and increased with age. These changes were maximal in anterior white matter. In the older group, anterior mean diffusivity correlated with executive function assessed by the Trail Making Test. CONCLUSIONS: These findings provide direct evidence that white matter tract disruption occurs in normal aging and would be consistent with the cortical disconnection hypothesis of age-related cognitive decline. Maximal changes in anterior white matter provide a plausible structural basis for selective loss of executive functions. In addition to providing new information about the biological basis of cognitive abilities, diffusion tensor MRI may be a sensitive tool for assessing interventions aimed at preventing cognitive decline.

Adult↗

L-arginine and S-nitrosoglutathione reduce embolization in humans.

BACKGROUND: L-Arginine reduces platelet aggregation and adhesion in ex vivo studies, but there is no evidence as yet that it has a therapeutic effect on clinical end points. Doppler ultrasound can detect cerebral emboli noninvasively. Such embolic signals are common after carotid endarterectomy, and their frequency predicts risk of stroke recurrence. We used this situation to determine the antiplatelet efficacy of L-arginine and S-nitrosoglutathione (GSNO), a physiological nitric oxide donor with possible platelet specificity. METHODS AND RESULTS: Patients undergoing carotid endarterectomy were randomized in a double-blind manner between L-arginine (n=14), GSNO (n=14), or placebo (n=14) administered intravenously for 90 minutes, starting 30 minutes after skin closure. All patients were pretreated with aspirin and given heparin during surgery. Transcranial Doppler recordings were made from the ipsilateral middle cerebral artery for 4 hours after surgery, beginning 30 minutes after skin closure, and also at 6 and 24 hours. There were highly significant reductions in the number of Doppler embolic signals in the L-arginine and GSNO groups; first 4 hours, median (range) number of embolic signals, placebo 44.7 (6 to 778), L-arginine 9.5 (0 to 225), and GSNO 0.8 (0 to 8), both P<0.001 versus control values. The reduction in the signals persisted at the 24-hour recording. CONCLUSIONS: Intravenous L-arginine and GSNO attenuate Doppler embolic signals in humans. Modulation of the NO system with these agents may have applications in the treatment of thromboembolic disease. This study demonstrates the potential application of ultrasonic embolic signal detection to examine the efficacy of new antiplatelet agents in relatively small numbers of patients.

Aged↗

MRI hyperintensities of the temporal lobe and external capsule in patients with CADASIL.

BACKGROUND: Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is an inherited, autosomal dominant condition caused by mutations of the Notch3 gene. Affected individuals have migraine, mood disturbance, and recurrent strokes, often progressing to subcortical dementia and premature death. MRI findings include focal lacunar infarcts and diffuse T2-weighted hyperintensity, or leukoaraiosis. However, such findings are seen much more commonly in patients with cardiovascular risk factors, particularly hypertension, where they are believed to represent cerebral small vessel disease. No previous study has sought to identify specific radiologic markers of CADASIL. METHODS: MRI scans from 20 consecutive patients with CADASIL and 20 patients with sporadic leukoaraiosis due to presumed small-vessel disease were compared using the previously validated semiquantitative MRI rating scale devised by Scheltens et al. Analysis was blinded to clinical category. RESULTS: Scores for hyperintensities of the temporal white matter and external capsule-insula region were significantly higher in patients with CADASIL. Hyperintensity confined to the pole of the temporal lobe was a characteristic finding in CADASIL, occurring in 19 patients with CADASIL but no patients with ischemic leukoaraiosis. Involvement of the external capsule, though less specific, was seen early in the disease course. In a few patients with CADASIL, involvement of the corpus callosum was observed. CONCLUSIONS: Temporal pole hyperintensity is a radiologic marker of CADASIL. Involvement of the external capsule and corpus callosum are also characteristic findings that may help to distinguish the disease.

Adult↗

Evaluation of a 1 MHz transducer for transcranial Doppler ultrasound including embolic signal detection.

A 1 MHz transducer for use with transcranial Doppler ultrasound may improve the intensity and therefore the detection of embolic signals (ES) and may also reduce the number of absent acoustic windows. A series of studies was performed to investigate its potential benefits. Firstly, ES were detected using a 1 MHz and a 2 MHz transducer both in vitro and in vivo. Secondly, the time taken to identify 100 middle cerebral arteries (MCA) was recorded for both transducers and the best Doppler signal obtained was reviewed off-line and graded for quality. ES were more intense when detected with the 1 MHz compared with the 2 MHz transducer, both in vitro (p <.0001) and in vivo (p <.0001). Of the 100 MCAs studied, 81 had acoustic windows identified with both transducers. The number of acoustic windows detected with one transducer but not the other was the same for both transducers (n = 3). The time taken to identify the MCA was longer with the 1 MHz transducer (p <.0001) and the quality of the signal achieved was poorer (p <.0001). In conclusion, the 1 MHz transducer improved embolic signal intensity but the overall quality of the flow spectrum obtained was poorer with the 1 MHz than with the 2 MHz transducer. A lower frequency transducer of 1 MHz or possibly 1.5 MHz with transcranial Doppler ultrasound may improve the application of embolic signal detection but may not improve the signal for routine measurement of flow velocities.

Endarterectomy, Carotid↗

MRI based diffusion and perfusion predictive model to estimate stroke evolution.

In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/- 0.19 and 1.20 +/- 0.36. For recovered tissue the mean values were 0.99 +/- 0.25 and 1.87 +/- 0.71, respectively. There was a significant difference between these two regions for both measures (p < 0.003 and p < 0.001, respectively). Mean absolute measures of CBF (ml/100g/min) and CBV (ml/100g) for the total infarcted territory were 33.9 +/- 9.7 and 4.2 +/- 1.9. For recovered MTT tissue, the mean values were 41.5 +/- 7.2 and 5.3 +/- 1.2, respectively. A significant difference was also found for these regions (p < 0.009 and p < 0.036, respectively). The mean measures of sensitivity, specificity, positive and negative predictive values for modeling infarct evolution for the validation patient data were 0.72 +/- 0.05, 0.97 +/- 0.02, 0.68 +/- 0.07 and 0.97 +/- 0.02. We propose that this automated strategy may allow possible guided therapeutic intervention to stroke patients and evaluation of efficacy of novel stroke compounds in clinical drug trials.

Aged↗

Ischaemic heart disease and Cag A strains of Helicobacter pylori in the Caerphilly heart disease study.

OBJECTIVE: To look for the presence of the more virulent strains of Helicobacter pylori (H pylori) in men who developed ischaemic heart disease over a 10 year period and in controls. DESIGN: The Caerphilly prospective heart disease study recruited 2512 men aged 45-59 years during 1979-83. Western blot analysis or enzyme linked immunosorbent assay (ELISA) was performed on serum taken from those who subsequently died of ischaemic heart disease, or developed non-fatal myocardial infarction, to determine H pylori and Cag A status. Similar information was available on age matched controls. RESULTS: During the first decade of the study, 312 men died of ischaemic heart disease or developed non-fatal myocardial infarction. Serum was available from 172 of these (55%). There was no evidence of an association between Cag A seropositivity and incident ischaemic heart disease or ischaemic heart disease mortality, either before or after adjustment for potential confounders (adjusted odds ratios 1.18 (95% confidence interval (CI) 0.76 to 1.85) and 1.13 (95% CI 0.61 to 2.07), respectively). Further, the odds ratios for ischaemic heart disease incidence and ischaemic heart disease mortality by H pylori seropositivity did not appear to depend on the presence or absence of Cag A strains (p = 0.76 and 0.77, respectively). CONCLUSIONS: In this cohort of middle aged men, followed over a 10 year period, there is little evidence of an association between Cag A seropositivity and either incident ischaemic heart disease or ischaemic heart disease mortality.

Antigens, Bacterial↗

Magnetic resonance markers of ischaemia: their correlation with vasodilatory reserve in patients with carotid artery stenosis and occlusion.

OBJECTIVES: Better methods of identifying patients with asymptomatic carotid artery stenosis who are at high risk of stroke are required. It has been suggested that proton magnetic resonance spectroscopy (MRS) may allow the identification of ongoing ischaemia in this patient group by the detection of a potentially reversible reduction of N-acetyl aspartate (NAA), a presumed marker of neuronal integrity, and the presence of lactate, a marker of anaerobic metabolism. Previous studies have reported metabolite ratios rather than absolute concentrations. This study was performed to determine if NAA was reduced ipsilateral to carotid stenosis or occlusion, and if its concentration was related to carbon dioxide reactivity, a marker of cerebrovascular reserve. METHODS: Twenty one patients with unilateral carotid stenosis (>70%) or occlusion were studied. Single voxel proton MRS was performed in the ipsilateral and contralateral hemispheres, with the voxel positioned in the arterial borderzone region between the middle and anterior cerebral artery territories. Absolute quantification of metabolite concentrations was performed. Cerebrovascular reactivity to 6% carbon dioxide was determined in both middle cerebral artery territories using transcranial Doppler ultrasonography. RESULTS: Mean (SD) cerebrovascular reactivity was significantly lower in the stenosed compared with the contralateral hemisphere (13.3 (7.7) v 19.2 (8.2)%/kPa, p=0.002). There were no significant differences in the absolute concentrations of NAA, choline, or creatine between the ipsilateral and contralateral hemispheres (for example, NAA 10.1 (1.1) v 10.5 (1.1) mmol/l, p=0.1). No lactate peak was seen in any spectra. For each metabolite measured, there was no correlation between the absolute concentration and cerebrovascular reactivity for either hemisphere. CONCLUSIONS: In patients with carotid stenosis and occlusion we found no evidence that chronic hypoperfusion is associated with a reduction in NAA or the presence of lactate. Magnetic resonance spectroscopy is unlikely to help in the selection of patients with asymptomatic carotid stenosis for endarterectomy.

Aged↗

The effect of the nitric oxide donor glyceryl trinitrate on global and regional cerebral blood flow in man.

Despite their potential use as cerebral vasodilatory agents there are few studies of the effect of nitric oxide (NO) donors on the cerebral circulation in non-anaesthetised man. We determined the effect of the NO donor glyceryl trinitrate (GTN) at clinically relevant doses on global and regional cerebral blood flow (CBF) in healthy non-anaesthetised volunteers, using H(2)(15)O PET, ultrasonic colour velocity flow imaging of carotid artery flow, and transcranial Doppler (TCD) of middle cerebral artery velocities (MCAv). Three rates of GTN infusion (0.1, 0.4, 1.0 microg/kg/min) were used. There was no significant change in common or internal carotid artery flow following GTN administration although a dose dependent fall in MCAv post GTN was observed. There was no significant change in either global or regional CBF following GTN. Thus intravenous GTN at therapeutic doses in awake humans does not alter global or regional CBF. However it does produce basal cerebral artery vasodilatation as evidenced by a fall in MCAv in the absence of a change in internal carotid artery flow.

Adult↗

Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging.

Quantitative, multislice dynamic susceptibility contrast-enhanced MRI perfusion measurements were used to determine the patterns of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and normalized first moment of the tissue deltaR2-time curve (N) in 11 subjects with carotid artery occlusion or stenosis. MTT correlated with degree of carotid stenosis, whereas a range of alterations in CBF and CBV were found presumably reflecting variables degrees of collateral flow. There was no significant correlation between MRI and SPET flow perfusion measurements, with increasing disparity between the two techniques at higher inter-hemispheric flow ratios. The effect of obtaining the arterial input function (AIF) from the middle cerebral artery (MCA) ipsilateral or contralateral to the stenosis was determined. Despite the use of an AIF from the MCA, which is distal to the circle of Willis, and hence the major sources of collateral supply, there was still some extra dispersion of the contrast agent bolus due to differences in arrival time.

Aged↗

Optimization of processing parameters for the analysis and detection of embolic signals.

The fast Fourier transform (FFT), which is employed by all commercially available ultrasonic systems, provides a time-frequency representation of Doppler ultrasonic signals obtained from blood flow. The FFT assumes that the signal is stationary within the analysis window. However, the presence of short duration embolic signals invalidates this assumption. For optimal detection of embolic signals if FFT is used for signal processing, it is important that the FFT parameters such as window size, window type, and required overlap ratio should be optimized. The effect of varying window type, window size and window overlap ratio were investigated for both simulated embolic signals, and recorded from patients with carotid artery stenosis. An optimal compromise is the use of a Hamming or Hanning window with a FFT size of 64 (8.9 ms) or 128 (17.9 ms). A high overlap ratio should also be employed in order not to miss embolic events occurring at the edges of analysis windows. The degree of overlap required will depend on the FFT size. The minimum overlap should be 65% for a 64-point window and 80% for a 128-point window.

Blood Flow Velocity↗

Genetics and ischaemic stroke.

Ischaemic stroke can be caused by a number of monogenic disorders, and in such cases stroke is frequently part of a multisystem disorder. Cerebral autosomal dominant arteriopathy with subcortical infarcts and leucoencephalopathy (CADASIL), due to mutations in the NOTCH: 3 gene, is increasingly appreciated as a cause of familial subcortical stroke. The genetics and phenotypes of monogenic stroke are covered in this review. However, the majority of cases of ischaemic stroke are multifactorial in aetiology. Strong evidence from epidemiological and animal studies has implicated genetic influences in the pathogenesis of multifactorial ischaemic stroke, but the identification of individual causative mutations remains problematic; this is in part limited by the number of approaches currently available. In addition, genetic influences are likely to be polygenic, and ischaemic stroke itself consists of a number of different phenotypes which may each have different genetic profiles. Almost all human studies to date have employed a candidate gene approach. Associations with polymorphisms in a variety of candidate genes have been investigated, including haemostatic genes, genes controlling homocysteine metabolism, the angiotensin-converting enzyme gene, and the endothelial nitric oxide synthase gene. The results of these studies, and the advantages and limitations of the candidate gene approach, are presented. The recent biological revolution, spurred by the human genome project, promises the advent of novel technologies supported by bioinformatics resources that will transform the study of polygenic disorders such as stroke. Their potential application to polygenic ischaemic stroke is discussed.

Animals↗

Reduced cerebral blood flow in white matter in ischaemic leukoaraiosis demonstrated using quantitative exogenous contrast based perfusion MRI.

OBJECTIVE: White matter hypoperfusion may play a part in the pathogenesis of ischaemic leukoaraiosis, but demonstration of this requires a high resolution quantitative method of cerebral blood flow (CBF) measurement. Initial exogenous contrast based MRI methods only allowed measurement of relative cerebral blood volume (CBV) values, but more recently a mathematical approach has been developed which enables absolute regional CBF and CBV to be determined. This technique was applied to patients with ischaemic leukoaraiosis to determine whether reduced white matter CBF in this patient group could be demonstrated. METHODS: Eight patients with ischaemic leukoaraiosis (radiological leukoaraiosis and clinical lacunar stroke), and nine age matched controls were studied. A spin echo echoplanar image sequence was used on a 1.5 Tesla MR system. An arterial input function was obtained from voxels placed over the middle cerebral arteries. Cerebral blood flow, CBV, and mean transit (MTT) maps were derived. Regions of interest were placed at standard positions in the white and grey matter and mean values of CBF, CBV, and MTT were compared between the two groups. RESULTS: Mean (SD) white matter CBF was significantly reduced in patients by 38% (13.40 (4.87) v 21.74 (3.53) ml/min/ 100 g, p=0.002). Significant reductions in CBF were seen in all white matter regions. By contrast there was no reduction in CBF in any grey matter region. There was no significant difference in white matter CBV between cases and controls; mean values were lower in all white matter regions for patients but this did not reach significance for any region. By contrast mean grey matter CBV was significantly higher in patients than in controls. Mean MTT values were higher in all regions of grey and white matter in the patient group, but this only achieved significance for the superior white matter. CONCLUSION: A quantitative MR perfusion method showed reduced white matter CBF in patients with ischaemic leukoaraiosis, but normal grey matter CBF. This is consistent with hypoperfusion playing a part in the pathogenesis of ischaemic leukoaraiosis. The absolute values of white matter and grey matter CBF obtained in the patient groups were very similar to those in previous PET studies, providing further evidence for the validity of the regional CBF measurements obtained using this quantitative MR perfusion technique. The high spatial resolution and lack of radioactive administration makes such techniques ideal for longitudinal studies in this condition.

Aged↗

Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts.

BACKGROUND AND PURPOSE: The clinical application of Doppler detection of circulating cerebral emboli will depend on a reliable automated system of embolic signal detection; such a system is not currently available. Previous studies have shown that frequency filtering increases the ratio of embolic signal to background signal intensity and that the incorporation of such an approach into an offline automated detection system markedly improved performance. In this study, we evaluated an online version of the system. In a single-center study, we compared its performance with that of a human expert on data from 2 clinical situations, carotid stenosis and the period immediately after carotid endarterectomy. Because the human expert is currently the "gold standard" for embolic signal detection, we also compared the performance of the system with an international panel of human experts in a multicenter study. METHODS: In the single-center evaluation, the performance of the software was tested against that of a human expert on 20 hours of data from 21 patients with carotid stenosis and 18 hours of data from 9 patients that was recorded after carotid endarterectomy. For the multicenter evaluation, a separate 2-hour data set, recorded from 5 patients after carotid endarterectomy, was analyzed by 6 different human experts using the same equipment and by the software. Agreement was assessed by determining the probability of agreement. RESULTS: In the 20 hours of carotid stenosis data, there were 140 embolic signals with an intensity of > or =7 dB. With the software set at a confidence threshold of 60%, a sensitivity of 85.7% and a specificity of 88.9% for detection of embolic signals were obtained. At higher confidence thresholds, a specificity >95% could be obtained, but this was at the expense of a lower sensitivity. In the 18 hours of post-carotid endarterectomy data, there were 411 embolic signals of > or =7-dB intensity. When the same confidence threshold was used, a sensitivity of 95.4% and a specificity of 97.5% were obtained. In the multicenter evaluation, a total of 127 events were recorded as embolic signals by at least 1 center. The total number of embolic signals detected by the 6 different centers was 84, 93, 108, 92, 63, and 78. The software set at a confidence threshold of 60% detected 90 events as embolic signals. The mean probability of agreement, including all human experts and the software, was 0.83, and this was higher than that for 2 human experts and lower than that for 4 human experts. The mean values for the 6 human observers were averaged to give P=0.84, which was similar to that of the software. CONCLUSIONS: By using the frequency specificity of the intensity increase occurring with embolic signals, we have developed an automated detection system with a much improved sensitivity. Its performance was equal to that of some human experts and only slightly below the mean performance of a panel of human experts

Algorithms↗

Transcranial Doppler ultrasound.

Transcranial Doppler ultrasound allows measurements of blood flow velocity to be made from the basal intracerebral vessels. The major advantages of transcranial Doppler ultrasound are that it is non-invasive, relatively cheap, can be performed with portable machines, allows monitoring for prolonged periods, and has a high temporal resolution making it ideal for studying dynamic cerebrovascular responses. In addition it has recently been demonstrated that it can be used to detect circulating cerebral emboli; these cannot be detected by any other currently available imaging modality.

Arterial Occlusive Diseases↗

Effect of inhibition of nitric oxide synthase on dynamic cerebral autoregulation in humans.

Cerebral blood flow is maintained constant over a range of cerebral perfusion pressures by cerebral autoregulation. Impaired cerebral autoregulation may be important in the pathogenesis of cerebral ischaemia. The mechanisms mediating normal cerebral autoregulation in humans are poorly understood. We used a recently described transcranial Doppler technique, which allows non-invasive measurement of dynamic cerebral autoregulation, to test the hypothesis that nitric oxide mediates cerebral autoregulation. The rate of rise of middle cerebral artery blood flow velocity, compared with that of arterial blood pressure, was determined following a stepwise fall in arterial blood pressure, in order to calculate an autoregulatory index. The effect of the nitric oxide synthase inhibitor N(G)-monomethyl-L-arginine (L-NMMA) on dynamic autoregulation was compared with that of noradrenaline titrated to result in a similar rise in blood pressure. Six healthy subjects were studied in each group. The mean (S.D.) change in autoregulatory index following noradrenaline at a similar pressor dose was significantly greater than the change following the L-NMMA bolus: 1. 1 (1.2) compared with -0.8 (0.8) for the left middle cerebral artery (P=0.002), and 1.1 (0.8) compared with -0.8 (0.8) for the right middle cerebral artery (P=0.002). There was no difference in the mean (S.D.) blood pressure increase resulting from the two agents: L-NMMA, 19.7 (7.4) mmHg; noradrenaline, 15.5 (4.8) mmHg (P=0.281). These results suggest that nitric oxide mediates at least part of the dynamic phase of cerebral autoregulation in humans. Reduced nitric oxide release may play a role in the impaired cerebral autoregulation seen in patients with, or at risk of, cerebral ischaemia.

Adult↗

Chlamydia pneumoniae infection and early asymptomatic carotid atherosclerosis.

BACKGROUND: Chronic Chlamydia pneumoniae infection has been implicated in the pathogenesis of atherosclerosis but whether it plays a role at an early stage in the disease is uncertain. An early estimate of atherosclerosis can be obtained by ultrasonic imaging of the carotid artery to determine intima-media thickness (IMT) and the thickness of any atheroma plaques. METHODS AND RESULTS: In 983 normal population individuals aged 30 to 70 years, we measured common carotid artery (CCA) and carotid bulb IMT, and also carotid plaque thickness and the degree of internal carotid artery (ICA) stenosis. C. pneumoniae IgA titers of >/=16 and IgG titers of >/=64 were taken as positive. There was no association between C. pneumoniae IgA or IgG seropositivity with right, left, or mean CCA or bulb IMT, or with the presence of carotid plaques. There was a significant association between IgA seropositivity and >50% mean carotid stenosis with an odds ratio of 5.24 (95% CI 1.24 to 22.21, P=0.0245) after controlling for age and sex; after controlling for other cardiovascular risk factors, this was not significant 3.96 (95% CI 0. 84 to 18.78, P=0.082). No association was found between IgA or IgG seropositivity and markers of fibrinogen, log C-reactive protein, or leukocyte count. CONCLUSIONS: We found no evidence that serological evidence of C. pneumoniae infection is associated with early atherosclerosis. It is possible that IgA seropositivity is associated with more advanced disease but this hypothesis needs to be examined in a population with a higher prevalence of advanced atherosclerosis. We found no evidence that C. pneumoniae results in a chronic systemic inflammatory state.

Adult↗

Frequency filtering improves ultrasonic embolic signal detection.

Problems in detection of Doppler cerebral embolic signals primarily occur for embolic signals of low relative intensity. A characteristic feature of embolic signals is that the intensity increase is maximal over a narrow frequency band. Therefore, frequency filtering of the data might improve embolic signal relative intensity and detectability. We implemented an off-line finite impulse response filter in software running on a commercially available transcranial Doppler system, using the time-domain audio data as input. The range of the filter was chosen by placing a box around the embolic signal on the spectral display. One hundred consecutive embolic signals from patients with carotid stenosis were analyzed; all had been recorded by a bigate system and the signal was analyzed in both proximal and distal channels. There was a highly significant increase in embolic signal relative intensity following frequency filtering; mean (SD) proximal channel prefiltering 12.75 (4.83) dB, postfiltering 16.36 (4.93) dB; distal channel prefiltering 13.42 (4.98) dB, postfiltering 16.60 (5.11) dB, for both p < 0.001. Despite all embolic signals being audible and visible in at least one channel on the frequency spectral display, in 17 cases, the amplitude increase associated with the embolic signal could not be clearly seen in time-domain data of one or both channels prior to filtering. Following frequency filtering, this was reduced to 5. Incorporation of such a frequency-filtering approach to an online system is likely to improve the sensitivity of online detection for embolic signals of low relative intensity.

Carotid Stenosis↗