Search PubMed⌕ Search

Biomedical subjects

H S Cardash

Publications and source records attributed to H S Cardash.

At least 19 recordsLinked to original sources

[Radiographic identification of dental implants in Israel].

Not infrequently a patient will attend seeking treatment for replacement of a lost abutment and crown from an implant placed by another dentist and no dental records are available. Many different root form implants of various designs, dimensions, surfaces, and connectors are available today posing a problem for the restorative dentist who must choose prosthetic parts that fit the implant or for a forensic dentist attempting to identify a victim. Implants installed in bone may be identified only by radiographs and knowledge of implant morphology. Four articles (1-4) were published between 1992-2002 dealing with the radiographic identification of implants. Since then many new implants have appeared on the market. Implants made in Israel do not appear at all on any of the lists. The object of this article is to provide radiographic pictures of implants available in Israel today together with a description of their radiographic features to enable Israeli dentists to identify implants where no dental records are available.

Dental Implantation, Endosseous↗

The flow rate of whole and submandibular/sublingual gland saliva in patients receiving replacement complete dentures.

Provision of complete dentures to a new denture wearer increases the salivary flow rate is well known. The new dentures act as an additional mechanical stimulus to the salivary reflexes, thus increasing the flow rate. The purpose of this study was to determine whether replacing complete dentures would elicit the same response. Unstimulated and stimulated whole and submandibular/sublingual (SM/SL) saliva were collected before inserting complete replacement dentures and again after 2 days and after 3 weeks of denture wearing. Unstimulated whole salivary flow rate increased significantly 2 days after inserting replacement dentures, decreasing at 3 weeks but remaining significantly above the baseline. Stimulated whole salivary flow rate increased significantly after 2 days but decreased to normal after 3 weeks. Stimulated and unstimulated SM/SL salivary flow rate increased significantly after 2 days, decreasing at 3 weeks while remaining significantly above the values found before denture insertion.

Aged↗

Relationship between occlusal plane determinants and craniofacial structures.

A cephalometric study was conducted on 34 complete denture wearers to investigate the relationship between the anatomical structures commonly used to determine the occlusal plane and the facial skeletal shape. The results showed no correlation between the shape of the skeletal face, the gonial angle and the length of the mandible versus the location of the retromolar pad, the occlusal plane and Camper's plane. However, a statistically significant linear correlation (P < 0.0001) was found between the facial skeletal shape designated SN POG and the location of Camper's plane. Cephalometric analysis alone cannot determine the location of the occlusal plane in edentulous patients. Intra-oral structures should also be considered.

Aged↗

Relationship between the craniofacial complex and size of the resorbed mandible in complete denture wearers.

A cephalometric study was conducted on 34 complete denture wearers to examine the relationship between the area of the mandible and the skeletal facial form, the area of the mandible and the gonial angle, and the area of the mandible and the length of the mandible. No significant correlation was found between the area of the mandible and the skeletal facial types or the gonial angle. A statistically significant correlation (P < 0.0028) was found between the length of the mandible and the area of the mandible. Residual resorption of the mandible appears to be independent of skeletal facial form and the gonial angle.

Aged↗

Effect of glaze thickness on the fracture toughness and hardness of alumina-reinforced porcelain.

STATEMENT OF PROBLEM: Although porcelain is the most esthetic restorative material available, it is subject to fracture during function. Glazing reduces the size of flaws in the surface of the porcelain and increases its resistance to crack propagation, but the optimum thickness of this glazed layer has not been determined. PURPOSE: This study compared the fracture toughness (Kc ) and Vickers hardness number (VHN) of an alumina-reinforced porcelain at different thicknesses of glaze. MATERIAL AND METHODS: Disks of feldspathic porcelain reinforced with 2% aluminum oxide were prepared and glazed for 0, 30, 60, 90, and 120 seconds. Fracture toughness and Vickers microhardness were determined with a microindentation technique. Thickness of the glazed layers was measured with a SEM. RESULTS: Mean Vickers hardness number and fracture toughness values both decreased significantly with glazing times from 0 to 60 seconds, and increased significantly with glazing times from 60 to 120 seconds (P <.001, ANOVA). SEM examination revealed an increase in glazed layer thickness with increased glazing time. CONCLUSIONS: Minimal and maximum thicknesses of glaze layers on alumina-reinforced porcelain resulted in a surface that was harder and more resistant to fracture than moderate glaze thicknesses.

Aluminum Oxide↗

A survey of output intensity and potential for depth of cure among light-curing units in clinical use.

OBJECTIVES: The light intensity of curing lights used in private dental offices was measured using commercial curing and heat radiometers and related to uniformity of cure depth of standardized composite specimens. METHODS: The intensity of 130 curing light from 107 dental offices was measured with curing and heat radiometers. Due to analogue readings, results were recorded in steps of 25 mW cm-2 and assigned a category number. A total of 50 lights were randomly selected to polymerize standardized 3 mm thick composite cylinders. The composite was irradiated for 50 s according to the manufacturer's instructions. The Knoop hardness value was measured at the top and bottom surfaces and the uniformity of cure depth was calculated from the ratio of these two values. RESULTS: Light intensity measured by the curing and heat radiometers was in the range of 25-825 and 0-325 mW cm-2, respectively. Functions of maximum likelihood estimation of the top and bottom surface hardness were 57 N/N + 1.3 and 80 N/N + 17.7, respectively (N = light intensity category number). The relationship between the logarithmic transformation of the hardness ratio and light intensity was linear (R2 = 0.84 p < 0.001). CONCLUSION: According to the manufacturer, a curing light is considered as unsuitable for use with a reading of < 200 mW cm-2 by the curing radiometer and > 50 mW cm-2 by the heat radiometer. Applying these criteria to the present study, 46% of the lights (without repetitions) required repair or replacement. The strong correlation found between the hardness ratio and light intensity verifies the usefulness of the curing radiometer in predicting the polymerization ability of the light activation units.

Composite Resins↗

In vivo retrospective study of cement thickness under crowns.

PURPOSE: This study evaluated the cement thickness under crowns cemented with zinc phosphate cement that had been in clinical use for at least 10 years. MATERIAL AND METHODS: A total of 97 teeth were extracted because of periodontal disease as part of a new treatment plan. Teeth were sectioned and the cement thickness measured at predetermined points on the occlusal and axial walls with a measuring microscope at x150 magnification. RESULTS: Mean cement thicknesses on buccal and lingual walls were similar (116 microns and 109 microns, respectively), but much smaller than on occlusal walls (310 microns). Cement thicknesses at occlusal locations were significantly thicker in molars than in premolars. Poor correlations existed between cement thicknesses on buccal and lingual walls (0.26) and between these and the occlusal walls (0.35) implying that incomplete seating is strongly related to tilting or oblique seating. CONCLUSION: Under clinical conditions where more inherent difficulties exist, special measures must be taken to alleviate the consequences of cement fluid dynamics.

Analysis of Variance↗

The closure of the gingival crevice following gingival retraction for impression making.

Scant attention has been paid to the effectiveness of chemomechanical displacement of the gingiva prior to impression making for fixed partial dentures. The closure of the gingival crevice following removal of medicated retraction cord was observed using a miniature video camera. Sulcular widths were measured at time intervals at the midbuccal and transitional line angle areas. The closure rate of the transitional line angle area was significantly faster than that of the mid-buccal area during the first 90 s. An average sulcular width of 0.2 mm was reached at the transitional line angle after less than 30 s.

Adult↗

The effect of marginal thickness on the distortion of different impression materials.

An impression of the margins of a prepared tooth and adjacent gingival sulcus must be of sufficient thickness to withstand distortion and tearing when the impression is removed from the mouth. The purpose of this study was to compare the dimensional accuracy of Elite, Examix, and Express polyvinyl siloxanes; Permadyne polyether; and Permlastic polysulfide elastomeric impression materials. These materials were used to make impressions of a metal model that simulated prepared abutments with gingival sulci of various widths. A traveling microscope was used to measure the abutments and impression widths, and the number of defects in each impression was recorded. Between 70% and 100% of the abutment impressions with sulcular widths of 0.05 mm exhibited defects, which prevented accurate measurements in this group. Express material demonstrated a high number of defects in the 0.10 and 0.16 mm sulcular width groups. No great difference in average maximum distortion values or coefficients of variation (CV) were detected among the materials used to make impressions of abutments with sulcular width groups of 0.2 to 0.4 mm. For the sulci of 0.16 mm and less, Examix and Permiastic materials exhibited distortion and a CV comparable to the impressions of the wider sulcular groups, whereas Elite and Permadyne showed greater distortions and CVs. The differences were not statistically significant (analysis of variance) because of the larger CV among the groups. The larger coefficient of variation in the 0.1 and 0.16 mm sulcular width groups demonstrated inconsistencies in obtaining good impressions of abutments with such narrow sulcular widths.

Analysis of Variance↗

Effect of different cooling rates on fracture toughness and microhardness of a glazed alumina reinforced porcelain.

Dental porcelain has superior esthetics but may be subject to fracture during mastication. Residual compressive stresses on the porcelain surface after cooling enhance resistance of porcelain to crack initiation, as quantified by its fracture toughness (Kc). The effect of different cooling rates on Kc and hardness of a glazed porcelain reinforced with approximately 2% aluminum oxide was examined in 45 porcelain disks that were divided into three groups. After final glaze firing, one group was cooled rapidly, the second was cooled at a medium rate, and the third was cooled slowly. Fracture toughness was determined with a microindentation procedure. The mean Kc recorded for rapidly cooled porcelain (1.74 +/- 0.09 MN/m3/2), for medium-cooled porcelain (1.41 +/- 0.07 MN/m3/2), and for slow-cooled porcelain (1.29 +/- 0.07 MN/m3/2) was statistically different (p < 0.001, analysis of variance and Bonferroni post hoc test). No statistically significant differences in Vickers hardness values were recorded when porcelain was cooled at different rates (530 to 540) (analysis of variance). The faster cooling rate of a glazed alumina reinforced porcelain resulted in greater fracture toughness but had no effect on hardness.

Aluminum Oxide↗

Surface roughness of tooth shoulder preparations created by rotary instrumentation, hand planing, and ultrasonic oscillation.

A dentinal shoulder with a smooth surface is necessary to ensure accurate adaptation of a porcelain crown. The surface roughness of dentinal shoulders prepared with different instruments was investigated in this in vitro study. Sixty shoulders, 1 mm wide, were prepared with coarse grit diamonds in extracted formalin-stored teeth. Of these 60 shoulders 20 were further refined with fine grit, and 20 more shoulders were refined with super-fine grit diamonds. The surface roughness (Ra) of the dentinal shoulders was recorded after each procedure. Thirty surfaces were further finished and refined with a hand chisel, and the other 30 surfaces were finished with a flat-ended diamond tip held in an ultrasonic generating device; the Ra was then recorded. These shoulder preparations were examined under a scanning electron microscope. The Ra of the dentinal shoulders prepared by the ends of the different grit diamonds was not significantly different (p > 0.05). Hand planing did not improve the Ra, and ultrasonic planing significantly increased the Ra (p < 0.05). Scanning electron micrographs revealed no apparent qualitative differences between surface roughness of the shoulders prepared by the diamonds or by the hand-planed surface. However, deeper scratches were evident at ultrasonically planed surfaces.

Crowns↗

The sealing of the tooth/amalgam interface by corrosion products.

A marginal gap exists between the amalgam restoration and the cavity walls. At this interface, there is a constant percolation of fluid containing ions, molecules and bacteria. With time, corrosion products of the amalgam components seal the gap at the amalgam/tooth interface. The corrosion processes for conventional and high copper amalgam and factors affecting the corrosion deposits are reviewed. Better amalgam adaptation to the cavity walls improves the chances of sealing the restoration by corrosion products. The effectiveness of cavity varnish in preventing microleakage until corrosive deposits are formed is discussed.

Copper↗

Modalities of treatment for the combination syndrome.

A series of destructive changes occurring in the jaws of patients wearing a complete maxillary denture opposed by a mandibular distal extension removable partial denture have been described as the combination syndrome. However, the syndrome does not occur in all patients. Those patients who have not developed signs of the combination syndrome and whose mandibular anterior teeth are well preserved and not overerupted may be treated conservatively with a mandibular removable partial denture. A properly designed removable partial denture that distributes occlusal stresses over hard and soft tissues minimizes the risk of developing the combination syndrome. Nevertheless, the overdenture seems to provide a more predictable prognosis, especially for patients who already have the combination syndrome or whose mandibular anterior teeth are structurally or periodontally compromised or overerupted. The treatment modality is determined by the apparent potential of the patient to develop the combination syndrome and by the condition of the remaining mandibular anterior teeth.

Alveolar Bone Loss↗

Removable partial denture with a lateral rotational path of insertion.

A removable partial denture with a lateral path of insertion is useful when unsightly facial clasps are objectional to the patient. Rounded rest seat preparations allow extensions of the minor connector to rotate laterally into embrasure undercuts, providing retention. Guiding planes on the contralateral side ensure a different path of withdrawal from the retentive elements. A Kennedy Class IV arch with a long edentulous span is used to illustrate the denture design.

Dental Clasps↗

Long term sealing properties of Amalgambond under amalgam restorations.

The degree of microleakage at 14 days, 6 months and 1 year between Class V amalgam restorations lined with Copalite varnish or with Amalgambond was compared in this in vitro study. The restored teeth were subjected to cyclic occlusal loading, thermocycling procedures and then stored in a dye solution at the appropriate intervals. Dye penetration was assessed at the gingival and occlusal margins of the restorations. The results showed that with Amalgambond, there was significantly better sealing of the dentin tubules than with Copalite or unlined restorations (P < 0.001) at all times tested. Amalgambond showed significantly less microleakage as compared to unlined restorations (P < 0.01) at all time periods, and significantly less short-term (14 days) microleakage compared with the Copalite-lined group (P < 0.01).

Dental Amalgam↗

The effect of porcelain color on the hardness of luting composite resin cement.

Visible light- and dual-curing composite resin luting cements were cured under porcelain disks of different colors to examine the effect of porcelain color on surface hardness. Knoop microhardness measurements were made at exposure times of 48, 72, and 120 seconds. Higher levels of hardness were obtained with dual-cured resin. Visible light-cured resin irradiated through colored porcelain required more prolonged exposure times to reach a degree of hardness approaching that of dual-cure resin. From the standpoint of microhardness, dual-cured composite resin is preferred for luting porcelain restorations of > or = 2 mm thickness.

Analysis of Variance↗

Varnish application technique and microleakage of amalgam restorations.

Various techniques for applying two types of varnish to control microleakage of Class V amalgam restorations were compared in vitro. The drying time for each layer of varnish with a gentle air spray was varied, including delays in applying the second coat and the placement of the amalgam restoration. Microleakage was recorded by dye penetration. Both varnishes were inefficient at reducing dye penetration at the gingival wall. There were no statistical differences in dye penetration at the gingival wall between the two varnishes, regardless of the method of application, or the presence of varnish. Both varnishes exhibited good sealing properties at the occlusal wall when used according to the manufacturer's instructions, but varnish application was technique-sensitive. Short-cuts in the procedure may increase leakage; too short a drying time of either varnish can cause microleakage similar to the control group without a varnish.

Analysis of Variance↗