Search PubMed⌕ Search

Biomedical subjects

H S An

Publications and source records attributed to H S An.

At least 19 recordsLinked to original sources

Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation.

STUDY DESIGN: Flexibility tests and finite element analyses were performed for the biomechanical evaluation of diagonal transfixation in pedicle screw instrumentation. OBJECTIVE: To assess the biomechanical advantages of diagonal transfixation compared with conventional horizontal transfixation. SUMMARY AND BACKGROUND DATA: A few pedicle screw instrumentation systems allow the use of cross-links in the diagonal direction. Such a diagonal transfixation is anticipated to improve the surgical construct stability, but its biomechanical qualities have not been completely evaluated. METHODS: Flexibility tests were performed on 10 calf lumbar spines (L2-L5). Specimens were subjected to pure moments up to 8.2 Nm in flexion, extension, lateral bending, and extension while the resulting movements of L3 and L4 were measured by a three-dimensional motion analysis system. The tested cases included (1) intact, (2) pedicle screw fixation without transfixation after total removal of the L3-L4 disc, (3) pedicle screw fixation with diagonal transfixation, and (4) pedicle screw fixation with horizontal transfixation. Three-dimensional finite element models of the tested surgical constructs were also developed by use of three-dimensional beam elements to investigate the effect of diagonal transfixation and horizontal transfixation on the construct stability and the corresponding stress changes in the screws. RESULTS: When compared with no transfixation, horizontal transfixation significantly improved the lateral bending and axial rotation stability by 15.7% and 13.9%, respectively, but there was no improvement of stability in flexion and extension. By contrast, diagonal transfixation significantly improved the flexion and extension stability by 12% and 10.7%, respectively, but not the lateral bending and axial rotation stability in comparison with no transfixation. Comparison between horizontal transfixation and diagonal transfixation showed that the stabilizing effect of diagonal transfixation was greater in flexion and extension (13% and 11%, P < 0.01) than that of horizontal transfixation but smaller in lateral bending (11%, P < 0.05) and axial rotation (6.6%, P > 0.1). Finite element model predictions of the motion changes were similar to the changes observed in flexibility tests. In horizontal transfixation, the load changes, compared with no transfixion, were a 0.02% increase in flexion-extension, a 27.5% increase in lateral bending, and a 58% decrease in axial rotation, and the magnitudes of the moments applied on both the right and left pedicle screws were identical. However, when diagonal transfixation was achieved by connecting the left superior screw and the right inferior screw, the loads in the left screw were increased by 11.5% in flexion-extension, 43.6% in lateral bending, and 7.9% in axial rotation, whereas the loads in the right screw were decreased by 10.9% in flexion-extension, increased by 0.06% in lateral bending, and decreased by 18.1% in axial rotation. CONCLUSIONS: The results of this study showed that diagonal transfixation provides more rigid fixation in flexion and extension but less in lateral bending and axial rotation in comparison with horizontal transfixation. Furthermore, greater stresses in the pedicle screws were predicted in the diagonal transfixation model. These limitations of diagonal transfixation should be considered carefully for clinical application.

Animals↗

Dorsal root ganglia morphologic features in patients with herniation of the nucleus pulposus: assessment using magnetic resonance myelography and clinical correlation.

STUDY DESIGN: Morphologic features of the dorsal root ganglia were investigated in patients with herniation of the nucleus pulposus by means of magnetic resonance myelography. OBJECTIVES: This study was undertaken to assess morphologic changes of the dorsal root ganglia in patients with herniation of the nucleus pulposus and to determine the relations between the morphologic features of the dorsal root ganglia and clinical features. SUMMARY OF BACKGROUND DATA: It has recently been reported that application of the nucleus pulposus to a nerve root induces edema in the rat dorsal root ganglion. Edema in the human dorsal root ganglion resulting from lumbar disc herniation has not been discussed in the literature, to the authors' knowledge. METHODS: Eighty-three consecutive patients (average age 42.1 years; range 17 to 77 years) with monoradicular symptoms were examined. Dorsal root ganglion morphologic features, i.e., indentations and swelling, were evaluated by magnetic resonance myelography. The dorsal root ganglion swelling at each level was quantitatively expressed as a ratio of the dorsal root ganglion width on the involved side to that of the contralateral side and was termed dorsal root ganglion ratio. Eighty-three uninvolved levels were chosen as controls in a randomized manner. Factors possibly contributing to the morphologic changes in the dorsal root ganglion were investigated. Neurologic symptoms, evaluated by the Japan Orthopaedic Association scoring system, were correlated to the morphologic changes. The morphologic features were followed up for 1 year after treatment in a small group of patients. RESULTS: Dorsal root ganglion indentations were always found in the narrowed intervertebral foramens. The incidence of indentations was significantly higher at the involved nerve roots (10.8%) than at the uninvolved nerve roots (4.0%) (P = 0.026). Patients with dorsal root ganglion indentations were significantly older (P = 0.0008). Leg pain scores in patients with indentations were significantly poor (P = 0.007). The dorsal root ganglion ratios were significantly higher at the involved levels than at the uninvolved levels (P = 0.001); the means +/- SD were 1.19 +/- 0.25 and 1.08 +/- 0.13, respectively. Patients with lateral herniated nucleus pulposus had significantly higher dorsal root ganglion ratios than those with central herniated nucleus pulposus (P = 0.0001); the mean ratios +/- SD were 1.48 +/- 0.32 and 1.10 +/- 0.12, respectively. A moderate positive correlation was found between dorsal root ganglion ratio and age (Pearson's correlation coefficient = 0.313). There was moderate negative correlation between the dorsal root ganglion ratio and leg pain, gait, motor, and total Japan Orthopaedic Association score (correlation coefficients were = -0.385, -0.350, -0.422, and -0.358, respectively). The dorsal root ganglion ratios were significantly diminished at 1-year follow-up (P = 0.001); the means +/- SD were 1.22 +/- 0.22 and 1.09 +/- 0.07, respectively. Indentations observed before treatment disappeared after treatment. CONCLUSIONS: Swelling and impingement in the involved dorsal root ganglion were clearly visualized by magnetic resonance myelography. The swelling and indentations were well correlated with severity of leg pain. These findings have important value in understanding the pathophysiology of the nerve roots in herniated nucleus pulposus.

Adolescent↗

A multicenter, prospective, randomized trial evaluating a new hemostatic agent for spinal surgery.

STUDY DESIGN: A prospective, randomized trial comparing Proceed, a gelatin-based hemostatic sealant (treatment), with Gelfoam-thrombin (control) in stopping intraoperative bleeding during spinal surgery. OBJECTIVES: To determine the effectiveness and safety of Proceed. SUMMARY OF BACKGROUND DATA: Proceed has been tested in animal models to determine its safety and effectiveness as a hemostatic agent. The current study was conducted under a Food and Drug Administration-approved Investigational Device Exemption to evaluate the effectiveness and safety of Proceed in humans. METHODS: For this study, 127 patients undergoing spinal surgery were randomized into either the treatment or control group after standard surgical means to control bleeding had failed. The bleeding site was evaluated at 1, 2, 3, 6, and 10 minutes after the hemostatic agent was applied. The application was considered successful if the bleeding stopped within 10 minutes. Follow-up evaluation was performed at 12 to 36 hours, then at 6 to 8 weeks after surgery. RESULTS: Proceed stopped bleeding in 98% of the patients (first bleeding site only) within 10 minutes, as compared with 90% of the control patients (P = 0.001). At 3 minutes, successful hemostasis had been achieved in 97% of the Proceed group, as compared with 71% of the control group (P = 0.0001). There was no difference in the adverse event profile between the two groups. CONCLUSIONS: A significantly larger number of bleeding sites had achieved hemostasis with Proceed than with Gelfoam-thrombin at 1, 2, and 3 minutes after application. Proceed was as safe as Gelfoam-thrombin when used for hemostasis during spinal surgery procedures.

Administration, Topical↗

Morphologic changes in the lumbar intervertebral foramen due to flexion-extension, lateral bending, and axial rotation: an in vitro anatomic and biomechanical study.

STUDY DESIGN: A biomechanical and anatomic study with human cadaveric lumbar spine. OBJECTIVES: The purpose of this study is to examine the morphologic changes in the intervertebral foramen during flexion, extension, lateral bending, and axial rotation of the lumbar spine and to correlate these changes with the flexibility of the spinal motion segments. SUMMARY OF BACKGROUND DATA: Previous studies showed morphologic changes in the intervertebral foramen during flexion and extension; however, those changes during lateral bending and axial rotation were not well known. METHODS: There were 81 motion segments obtained from 39 human cadaveric lumbar spines (mean age 69 years). The motion segments were imaged with CT scanner with 1-mm thick consecutive sections. For biomechanical testing each motion segment was applied with incremental pure moments of flexion, extension, lateral bending, and axial rotation. Rotational movements of the motion segment were measured using VICON cameras. After application of the last load, the specimens were frozen under load, and then CT was performed with the same technique described above. Six parameters of the intervertebral foramen were measured, including foraminal width (maximum and minimum), foraminal height, disc bulging, thickness of ligamentum flavum, and cross-sectional area of the foramen. RESULTS: Flexion increased the foraminal width (maximum and minimum), height, and area significantly while significantly decreasing the disc bulging and thickness of ligamentum flavum (P < 0.05). However, extension decreased the foraminal width (maximum and minimum), height, and area significantly. Lateral bending significantly decreased the foraminal width (maximum and minimum), height, and area at the bending side, whereas lateral bending significantly increased the foraminal width (minimum), height, and area at the opposite side of bending. Likewise, axial rotation decreased the foraminal width (minimum) and area at the rotation side significantly while significantly increasing the foraminal height and foraminal area at the opposite side. The percent change in the foraminal area was found significantly correlated with the amount of segmental spinal motion except for the extension motion. CONCLUSIONS: This study showed that the intervertebral foramen of the lumbar spine changed significantly not only on flexion-extension but also on lateral bending and axial rotation. The percent change in cross-sectional foraminal area was correlated with the amount of segmental motion except for extension motions. Further studies are needed to assess the morphologic changes in the intervertebral foramen in vivo and to correlate clinically.

Adult↗

Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion.

STUDY DESIGN: Destructive compression tests and finite element analyses were conducted to investigate the biomechanical strength at the graft-endplate interface in anterior cervical fusion. OBJECTIVES: To investigate the effect of endplate thickness, endplate holes, and bone mineral density of the vertebral body on the biomechanical strength of the endplate-graft interface in an anterior interbody fusion of the cervical spine. SUMMARY OF BACKGROUND: Subsidence of the graft into the vertebral body is a well-known complication in anterior cervical fusion. However, there is no information in the literature regarding the compressive strength of the graft-endplate interface in relation to the endplate thickness, holes in the endplate, and bone mineral density of the vertebral body. METHODS: Biomechanical destructive compression tests and finite element analyses were performed in this study. Cervical vertebral bodies (C3-C7) isolated from seven cadaveric cervical spines (age at death 69-86 years, mean 79 years) were used for compression tests. Bone mineral density of each vertebral body was measured using a dual energy radiograph absorptiometry unit. Endplate thickness was measured using three coronal computed tomography images of the middle portion of the vertebral body obtained using a computer-assisted imaging analysis. Then each vertebral body was cut into halves through the horizontal plane. A total of 54 specimens, consisting of one endplate and half of the vertebral body, were obtained after excluding eight vertebrae with gross pathology on plain radiograph. Specimens were assigned to one of three groups with different endplate conditions (Group I, intact; Group II, partial removal; and Group III, complete removal) so that group mean bone mineral density became similar. Each endplate was slowly compressed until failure using an 8-mm-diameter metal indenter, and the load to failure was determined as a maximum force on a recorded force-displacement curve. The effect on the strength of the graft-endplate interface of various hole patterns in the endplate was studied using a finite element technique. The simulatedhole patterns included the following: one large central hole, two lateral holes, two holes in the anterior and posterior portion of the endplate, and four holes evenly distributed from the center of the endplate. Stress distribution in the endplate was predicted in response to an axial compressive force of 110 N, and the elements with von Mises stress greater than 4.0 MPa were determined as failed. RESULTS: The endplate thickness and bone mineral density were similar at all cervical levels, and the superior and inferior endplates had similar thickness at all cervical levels. There was no significant association between bone mineral density and endplate thickness. Load to failure was found to have a significant association with bone mineral density but not with endplate thickness. However, load to failure tends to decrease with incremental removal of the endplate, and load to failure of the specimens with an intact endplate was significantly greater than that of the specimens with no endplate. Finite element model predictions showed significant influence of the hole pattern on the fraction of the upper endplate exposed to fracture stress. A large hole was predicted to be more effective than the other patterns at distributing a compressive load across the remaining area and thus minimizing the potential fracture area. CONCLUSION: Results of this study suggest that it is important to preserve the endplate as much as possible to prevent graft subsidence into the vertebral body, particularly in patients with poor bone quality. It is preferable to make one central hole rather than multiple smaller holes in the endplate for vascularity of the bone graft because it reduces the surface area exposed to fracture stresses.

Aged↗

Pyogenic spondylitis in an S1-S2 immobile segment.

STUDY DESIGN: A case of pyogenic spondylitis in S1-S2 is presented. OBJECTIVE: To describe the diagnosis and management of this rare spondylitis. SUMMARY OF BACKGROUND DATA: The segment including the first and second sacral vertebrae is not mobile. Therefore, discitis of S1-S2 and adjacent spondylitis is very rare. To the authors' knowledge, this is the first reported case of infectious spondylitis in an immobile segment: S1-S2. METHODS: In addition to radiography and bone scintigraphy, magnetic resonance imaging was used to confirm the diagnosis. Changes consistent with infectious spondylitis were shown, including an epidural abscess. RESULTS: The patient was treated with laparoscopic drainage and biopsy. Staphylococcus aureus was cultured, and adequate antibiotics were administered. Repeat magnetic resonance imaging at approximately 4 months demonstrated normal signal intensity and disappearance of the abscess. CONCLUSION: Findings from this study show that pyogenic spondylitis can occur in immobile S1-S2.

Adolescent↗

A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine.

STUDY DESIGN: A biomechanical study was designed to assess relative rigidity provided by anterior, posterior, or combined cervical fixation using cadaveric cervical spine models for flexion-distraction injury and burst fracture. OBJECTIVES: To compare the construct stability provided by anterior plating with locked fixation screws, posterior plating with lateral mass screws, and combined anterior-posterior fixation in clinically simulated 3-column injury or corpectomy models. SUMMARY OF BACKGROUND DATA: Anterior plating with locked fixation screws is the most recent design and is found to provide better stability than the conventional unlocked anterior plating. However, there are few data on the direct comparison of biomechanical stability provided by anterior plating with locked fixation screws versus posterior plating with lateral mass screws. Biomechanical advantages of using combined anterior-posterior fixation compared with that of using either anterior or posterior fixation alone also have not been well investigated yet. METHODS: Biomechanical flexibility tests were performed using cervical spines (C2-T1) obtained from 10 fresh human cadavers. In group I (5 specimens), one-level, 3-column injury was created at C4-C5 by removing the ligamentum flavum and bilateral facet capsules, the posterior longitudinal ligament, and the posterior half of the intervertebral disc. In group II (5 specimens), complete corpectomy of C5 was performed to simulate burst injury. In each specimen, the intact spine underwent flexibility tests, and the following constructs were tested: (1) posterior lateral mass screw fixation (Axis plate) after injury; (2) polymethylmethacrylate anterior fusion block plus posterior fixation; (3) polymethylmethacrylate block plus anterior (Orion plate) and posterior plate fixation; and (4) polymethylmethacrylate block plus anterior fixation. Rotational angles of the C4-C5 (or C4-C6) segment were measured and normalized by the corresponding angles of the intact specimen to study the overall stabilizing effects. RESULTS: Posterior plating with an interbody graft showed effective stabilization of the unstable cervical segments in all loading modes in all cases. There was no significant stability improvement by the use of combined fixation compared with the posterior fixation with interbody grafting, although combined anterior-posterior fixation tended to provide greater stability than both anterior and posterior fixation alone. Anterior fixation alone was found to fail in stabilizing the cervical spine, particularly in the flexion-distraction injury model in which no contribution of posterior ligaments is available. Anterior plating fixation provided much greater fixation in the corpectomy model than in the flexion-distraction injury model. This finding suggests that preservation of the posterior ligaments may be an important factor in anterior plating fixation. CONCLUSIONS: This study showed that the posterior plating with interbody grafting is biomechanically superior to anterior plating with locked fixation screws for stabilizing the one-level flexion-distraction injury or burst injury. More rigid postoperative external orthoses should be considered if the anterior plating is used alone for the treatment of unstable cervical injuries. It was also found that combined anterior and posterior fixation may not improve the stability significantly as compared with posterior grafting with lateral mass screws and interbody grafting.

Aged↗

Comparison of biomechanical response to surgical procedures used for cervical radiculopathy: posterior keyhole foraminotomy versus anterior foraminotomy and discectomy versus anterior discectomy with fusion.

The objective of this study was to compare the change in flexibility of C5-C6 caused by three procedures using a three-dimensional nonlinear finite element model: posterior foraminotomy (keyhole procedure), anterior foraminotomy with discectomy, and anterior discectomy with fusion. The keyhole procedure produced a minor increase in motion. The anterior foraminotomy and discectomy produced one to two times greater motion. Anterior discectomy with fusion produced 50% to 100% reduction in motion. The posterior keyhole foraminotomy has a much lesser effect on the stability of the cervical spine segment than does an anterior procedure, and fusion is a requisite part of the anterior decompression procedure.

Biomechanical Phenomena↗

Orientation and osteoarthritis of the lumbar facet joint.

Several studies have shown an association between sagittal orientation of the facet joint and degenerative spondylolisthesis. There is currently no information available on the association between orientation of the facet joint and osteoarthritis. This study examined the association between orientation and osteoarthritis of the lumbar facet joints. One hundred eleven consecutive patients underwent plain radiography and magnetic resonance imaging. These patients were divided into two groups: No Degenerative Spondylolisthesis Group (98 patients) and Degenerative Spondylolisthesis Group (13 patients). In the No Degenerative Spondylolisthesis Group, segments with higher grades of osteoarthritis showed more sagittal orientation of the facetjoints at the L3-L4 and L4-L5 levels. The facet joint was oriented significantly more sagittally in the Degenerative Spondylolisthesis Group than in the No Degenerative Spondylolisthesis Group at the L4-L5 and L5-S1 levels. The severity of facet joint osteoarthritis was significantly higher in the Degenerative Spondylolisthesis Group than in the No Degenerative Spondylolisthesis Group at the L3-L4, L4-L5, and L5-S1 levels. A significant association was found between sagittal orientation and osteoarthritis of the lumbar facet joints, even in patients without degenerative spondylolisthesis. Facet joint osteoarthritis, rather than spondylolisthesis, is the pathoanatomic feature that is associated with sagittal orientation of the facet joints in patients with degenerative spondylolisthesis.

Aged↗

Foraminal stenosis of the lumbar spine: a review of 65 surgical cases.

This study provides clinical and radiographic information and characteristics that may best define the presence of significant lumbar foraminal stenosis and reports on the outcome of surgical intervention. Although anatomy of the lumbar intervertebral foramen (including static and dynamic pathologic compression of the exiting nerve root) has been described, few studies have focused on the clinical and radiographic features of foraminal stenosis requiring surgical intervention. We retrospectively studied 65 patients with lumbar foraminal stenosis for presenting clinical and radiographic features and intraoperative findings. Symptoms included leg and back pain (100%), paresthesias (45%), and subjective weakness (31%). Examination revealed lumbar tenderness (71%), limited lumbar extension (57%), focal motor weakness (48%), and positive tension signs (42%). The L5 nerve root was most often involved (75%). Almost 50% of patients had already undergone spinal decompression surgery. Surgical procedures included laminectomy and foraminotomy (52 patients) and laminotomy and foraminotomy (23 patients). A concomitant arthrodesis was performed in 63 patients. There were 29 excellent, 25 good, 6 fair, and 5 poor results based on a modified outcome scale at 32.5-month follow-up. Findings suggest that foraminal stenosis is a frequent cause of persistent symptoms after surgery, is most common at the lumbosacral junction, is best identified on parasagittal magnetic resonance images or on images reconstructed with computed tomography, and may be static or dynamic in etiology.

Adult↗

The effect of disc degeneration and facet joint osteoarthritis on the segmental flexibility of the lumbar spine.

STUDY DESIGN: A biomechanical and imaging study of human cadaveric spinal motion segments. OBJECTIVE: To investigate the effect of both disc degeneration and facet joint osteoarthritis on lumbar segmental motion. SUMMARY OF BACKGROUND DATA: Spinal degeneration includes the osteoarthritic changes of the facet joint as well as disc degeneration. Disc degeneration has been reported to be associated with spinal motion. The association of facet joint osteoarthritis with lumbar segmental motion characteristics and the combined influence of disc degeneration and facet osteoarthritis has not yet been investigated. METHODS: A total of 110 lumbar motion segments (52 female, 58 male) from 44 human lumbar spines were studied (mean age = 69 years). Magnetic resonance images were used to assess the disc degeneration from Grade I (normal) to Grade V (advanced) and the osteoarthritic changes in the facet joints in terms of cartilage degeneration, subchondral sclerosis, and osteophytes. Disc height, endplate size, and facet joint orientation and width also were measured from the computed tomographic images. Rotational movements of the motion segment in response to the flexion, extension, lateral bending, and axial rotational moments were measured using a three-dimensional motion analysis system. RESULTS: Female motion segments showed significantly greater motion (lateral bending: P < 0. 001, flexion: P < 0.01, extension: P < 0.05) and smaller endplate size (P < 0.001) than male ones. The segmental motion increased with increasing severity of disc degeneration up to Grade IV, but decreased in both genders when the disc degeneration advanced to Grade V. In male segments, the disc degeneration-related motion changes were significant in axial rotation (P < 0.001), lateral bending (P < 0.05), and flexion (P < 0.05), whereas female segments showed significant changes only in axial rotation (P < 0.001). With cartilage degeneration of the facet joints, the axial rotational motion increased, whereas the lateral bending and flexion motion decreased in female segments. In male segments, however, motion in all directions increased with Grade 3 cartilage degeneration and decreased with Grade 4 cartilage degeneration. Subchondral sclerosis significantly decreased the motion (female: axial rotation, P < 0. 05; extension, P < 0.05 vs.- male:flexion,P < 0.05). Severity of osteophytes had no significant association with the segmental motion. CONCLUSION: Axial rotational motion was most affected by disc degeneration, and the effects of disc degeneration on the motion were similar between genders. Facet joint osteoarthritis also affected segmental motion, and the influence differed for male and female spines. Further studies are needed to clarify whether the degenerative process of facet joint osteoarthritis differs between genders and how facet joint osteoarthritis affects the stability of the spinal motion segment.

Cadaver↗

The effect of age on inflammatory responses and nerve root injuries after lumbar disc herniation: an experimental study in a canine model.

STUDY DESIGN: An experimental investigation on the effect of age on pathologic events surrounding the herniated disc and at the adjacent nerve root. OBJECTIVES: To investigate the role of age on the inflammatory responses and nerve root damage surrounding a sequestered lumbar disc fragment using a dog model. SUMMARY OF BACKGROUND DATA: Lumbar disc herniation is manifested in patients by variable clinical findings, natural history, and resorption phenomena in which the variability is particularly noted among patients with different ages. There are no previous reports on the effect of age on pathologic events induced by the herniated disc. METHODS: Six beagle dogs, including two animals of each age group of 6, 12, and 24 months (human equivalent ages of 10, 15, and 24 years), were used in this study. The dogs underwent L4-L5, L5-L6, and L6-L7 laminotomy and discectomy under general anesthesia. An autologous intervertebral disc from the tail was divided into anulus fibrosus and nucleus pulposus fragments. The anulus fibrosus and nucleus pulposus fragments were placed in the anterolateral epidural space of L5-L6 and L6-L7, respectively. The L4-L5 discectomy site served as a control. Dogs were killed at 12 weeks after surgery. The lumbar spine was removed en bloc, and histologic sections were prepared consecutively and examined. RESULTS: In the nucleus pulposus group at L6-L7, neovascularity, and intensive infiltration of lymphocytes, macrophages, and fibroblasts were observed surrounding the nucleus pulposus fragment in the 24-month-old group only. Degenerative changes of the nerve root fibers were observed in the 24-month-old group only. In the control and anulus fibrosus groups at L4-L5 and L5-L6, there were no marked inflammatory reactions in all age groups. The nerve root fibers around the anulus fibrosus were normal in all age groups. CONCLUSIONS: There is an effect of age on the inflammatory response and nerve root injury caused by the herniated disc. The apparent neuroprotective mechanism in the young animal, and the apparent inflammatory and resorption changes of the nucleus pulposus fragment in the older animal are quite intriguing.

Aging↗

Anterior cervical fusion: a finite element model study on motion segment stability including the effect of osteoporosis.

STUDY DESIGN: Three-dimensional, nonlinear finite element models were used to evaluate the stability of the mid cervical spine after anterior fusion in patients with and without osteoporosis. OBJECTIVES: The objective of this study was to compare the change in flexibility of C5-C6 after anterior discectomy with both loose-fitting and tight-fitting fusion graft. SUMMARY OF BACKGROUND DATA: Many factors such as surgical technique, osteoporosis, and excess neck motion during the postoperative period may contribute to fusion failure. Knowledge about changes in biomechanical properties after the surgical procedure is important for selection of grafts with appropriate strength and for guiding patients in postoperative care and rehabilitation. METHODS: Analyses with anterior fusion models with both loose-fitting and tight-fitting graft were performed in a normal and an osteoporotic spine. The motion of the C5 vertebra in relation to the C6 vertebra were calculated, after multidirectional moment loads of 0.5 Nm combined with a compressive preload of 105 N. RESULTS: Loose-fitting graft produced both an increase and a decrease in motion under various external moment loads, with graft compressive stress below the compressive strength of the graft material. A reduction in motion was observed under all moment loads when a tight-fitting graft was used. The compressive stress in the tight-fitting graft was higher than the strength of the graft material. Osteoporosis increased the principal motions with both the loose-fitting graft and tight-fitting graft. Maximum increase in motion with a loose-fitting graft construct was observed under extension and axial torsion moment loads. CONCLUSIONS: Anterior discectomy and insertion of the loose graft resulted in increased motion. A tight-fitting graft is beneficial in reducing motion, but the stress within the graftincreases beyond the graft strength. The presence of osteoporosis was nominally significant when the graft was tight fitting.

Adult↗

The anatomic relation among the nerve roots, intervertebral foramina, and intervertebral discs of the cervical spine.

STUDY DESIGN: An anatomic study of the cervical intervertebral foramina, nerve roots, and intradural rootlets performed using a surgical microscope. OBJECTIVES: To investigate the anatomy of cervical root compression, and to obtain the anatomic findings related to cervical foraminotomy for the treatment of cervical radiculopathy. SUMMARY OF BACKGROUND DATA: Cervical foraminotomy is a procedure performed frequently for the management of cervical radiculopathy. However, anatomic studies of cervical foraminotomy have not been fully elucidated. METHODS: In this study, 18 cadavers were obtained for the study of the cervical spine. All the soft tissues were dissected from the cervical spine. Thereafter, laminectomy and facetectomy were performed on C4 through T1 using a surgical microscope. The nerve roots and surrounding anatomic structures, including intervertebral discs and foramina, were exposed. In addition, the intradural rootlets and their intersegmental connections were observed. RESULTS: The shape of the intervertebral foramina approximated a funnel, the entrance zone being the most narrow part and the root sleeves conical, with their takeoff points from the central dural sac being the largest part. Therefore, compression of the nerve roots occurred at the entrance zone of the intervertebral foramina. Anteriorly, compression of the nerve roots was caused by protruding discs and osteophytes of the uncovertebral region, whereas the superior articular process, the ligamentum flavum, and the periradicular fibrous tissues affected the nerve posteriorly. The C5 nerve roots were found to exit over the middle aspect of the intervertebral disc, whereas the C6 and C7 nerve roots were found to traverse the proximal part of the disc. The C8 nerve roots had little overlap with the C7-T1 disc in the intervertebral foramen. The C6 and C7 rootlets passed two disc levels in the dural sac. Also, a high incidence of the intradural connections between the dorsal rootlets of C5, C6, and C7 segments was found. CONCLUSIONS: This study demonstrated the anatomy of the nerve roots, rootlets, and intervertebral foramina, and may aid in understanding the pathology of cervical radiculopathy. The presence of intradural connections between dorsal nerve roots and the relation between the course of the nerve root and the intervertebral disc may explain the clinical variation of symptoms resulting from-nerve root compression in the cervical spine. To perform cervical foraminotomy for cervical radiculopathy, it is necessary to understand the detailed anatomy of the intervertebral foramina thoroughly.

Aged↗

The interspinous ligament of the lumbar spine. Magnetic resonance images and their clinical significance.

STUDY DESIGN: A preliminary study of magnetic resonance features of the interspinous ligament in degenerative lumbar spine. OBJECTIVES: To classify the magnetic resonance imaging features of the interspinous ligaments in relation to the patient's age, disc degeneration, and radiographic instability. Magnetic resonance imaging also was correlated with the histologic findings of the interspinous ligaments. SUMMARY OF BACKGROUND DATA: As reported, rupture of the interspinous ligament frequently is found in the degenerative lumbar spine. However, little information is available in the literature on imaging assessment of the interspinous ligament in degenerative lumbar disorders. METHODS: In this study, 24 interspinous ligaments at L1-L2 or L2-L3 from 15 patients with nondegenerated discs were selected to represent normal magnetic resonance features of the interspinous ligament, and 38 patients with the mean age of 49 years underwent functional radiography and magnetic resonance imaging. The magnetic resonance features of the interspinous ligament were classified into five categories according to their signal intensities: Type 1A (low intensity on T1- and T2-weighted images without hypertrophy of the spinal process); Type 1B (same signal pattern as in Type 1A with hypertrophy of spinal process); Type 2 (low intensity on T1- and high intensity on T2-weighted images); Type 3 (high intensity on T1-weighted images); and Type 4 (others). Seven patients with variable patterns of the interspinous ligament were selected to undergo histologic examinations. RESULTS: Of the interspinous ligaments considered normal, 80% were classified as Type 1A. There were 14 Type 1A, 30 Type 1B, 19 Type 2, 16 Type 3, and 20 Type 4 ligaments. The mean age and disc degeneration grade of the patients with the Type 1B ligaments was significantly higher. Instability was found to be associated with Type 2 interspinous ligaments (7 of 19), whereas instability rarely was noted in Types 1A (1 of 14) and 1B (1 of 30) ligaments. The histologic examination revealed that chondrometaplasia and necrotization of fiber bundle predominated in Type 1B, proliferation of cells and vascular invasion in Type 2, fatty degeneration in Type 3 ligaments. CONCLUSIONS: The magnetic resonance imaging characteristics may be helpful in assessing normal or pathologic changes in the interspinous ligaments.

Adolescent↗

Spine update. Lumbar foraminal stenosis.

Lumbar foraminal stenosis is an important pathologic entity to identify in the patient being treated for radicular symptoms. This update reviews the anatomy, clinical presentation, neuroradiographic evaluation, and treatment of pathology located in the intervertebral foramen. Patients with significant leg pain refractory to conservative treatment and concordance between the demonstrated area of stenosis and radicular symptoms and signs are candidates for the decompressive procedures discussed. The role of arthrodesis and spinal instrumentation in the management of foraminal stenosis also is addressed.

Humans↗

Biomechanical effect of anterior grafting devices on the rotational stability of spinal constructs.

In the thoracolumbar spine, frequently strut grafting is used to restore the anterior and middle column defects. Biomechanical stability of the surgical construct may be altered significantly depending on the type of anterior grafting devices. In this study, a biomechanical flexibility test was conducted to compare the stabilizing role of various types of anterior grafting devices, such as a polymethylmethacrylate block, tricortical iliac crest bone graft, one large Harms cage, and two small Harms cages using a calf lumbar corpectomy model. The Harms cage, especially one large cage, improved the axial rotational stability significantly in both anterior and posterior fixation groups as compared with the iliac bone or polymethylmethacrylate. No significant difference in the stabilizing role was found among different grafting devices in lateral bending, flexion, and extension. These results suggest that a more rigid spinal construct can be obtained by using a metal cage with improved friction at the cage-bone interface.

Animals↗