MR imaging of experimental meningeal melanomatosis in nude rats.

MR imaging of the rat brain has become an increasingly frequently used method in experimental neuroradiology. On a generally available 1.5 T whole body tomograph, supplemented with an individually made small coil and a special SE sequence we obtained fairly fine images of the structures of the rat brain. With gadolinium-DTPA, we were able to visualize posterior fossa and cervical leptomeningeal growth of intrathecally injected B16 melanoma in nude rats. Using MRI to follow experimental leptomeningeal metastasis, may provide a new means for diagnostic evaluation and preclinical testing of treatment modalities.

Animals

Switched array coils.

Switched array coils (SACs) are a useful tool in local coil imaging since they allow in a user-friendly manner one to make the best choice in the trade-off between field of view and signal-to-noise ratio. This is done by selecting the current path within a conductor array equipped with suitable switches. Since the switching can be controlled by the system, this allows changing of the coil dimensions within multislice sequences. Thus image quality can be improved due to smaller coil dimensions for a given slice and a larger area can be covered by electronically shifting this sensitive area. The principle can be applied to surface--as well as volume--coil designs.

Electronics, Medical

[A simplified technic in high-resolution MR tomography of the shoulder: ZEPRA (Zoom of Eccentric Positioned Regions by active Aliasing)].

A fairly easy method for high-resolution MR imaging of the shoulder is described. The combination of a defined arrangement of the gradients with a small-volume Helmholtz coil provides the possibility of a high zoom of structures apart from the magnet's centre. The maximal achievable zoom factor depends on the ratio of FOV/sensitive coil volume. The ZEPRA method acts by phase-encoded aliasing only. With this technique all interesting soft tissue of the shoulder may readily be visualized in every direction and with every type of sequence.

Humans

[Results of magnetic resonance tomography of the temporomandibular joint using optimized surface coils].

One hundred temporo-mandibular joints were examined with a super-conducting nuclear resonance tomograph (1.0 Tesla) using various high resolution surface coils. The optimal method proved to be a spin echo sequence with a repetition time of 1,000 msec and an echo period of 28 msec with a 4 mm slice width. There were significant advantages from the non-invasive MRT diagnosis of the temporo-mandibular joints when compared with CT and with arthrography in recognising abnormal discs, changes in the tissues and for post-operative control.

Adult

[MR tomographic demonstration of liquor pulsation].

With ECG-gated FLASH-sequences motion of cerebrospinal fluid (CSF) is demonstrated in axial slices of the zervikal vertebral column. The course of the movement is dissolved by signal enhancement of flowing structures in magnitude images and by velocity-dependent phases. It is shown with both methods, that the oscillation of the CSF within the cardiac cycle is superimposed by a directed movement, with is cranial directed in the lateral cervical subarachnoidal spaces and caudal in the ventral subarachnoidal spaces.

Cerebrospinal Fluid

Surface coil with variable geometry: a new tool for MR imaging of the spine.

A switchable-array surface coil for magnetic resonance (MR) imaging of the spine has been built that enables the user to change the working size of the coil depending on the volume of interest. The prototype has achieved similar image quality to that obtained with conventional coils of equal size. This type of antenna may reduce the number of individual coils necessary for a high-quality MR imaging study.

Humans

[High-resolution nuclear spin tomography of the hip joint using a Helmholtz surface coil].

A specially constructed Helmholtz surface coil enables one to obtain high resolution nuclear tomograms of the hip. Anatomical structures which are clinically important and which can regularly be shown are described. A pilot study has been carried out on 16 patients and typical findings are described in necrosis of the femoral head, osteoarthritis and changes resulting from tumours in the region. Possible further applications are discussed.

Adult

[Magnetic resonance tomography of the orbit using surface coils. Study technic, anatomy and initial clinical experience].

MRI of the orbit is strongly improved by the use of surface coils due to a higher signal-to-noise ratio. Oblique views without moving the patient present the optic nerve in full length on one slice. First experience with a small number of cases demonstrates normal anatomy and lesions in detail only at T1-weighted pulse sequences. Losses in contrast variation and detail accuracy are caused by movements of the eyeballs. Edge artifacts due to chemical shifting impair the image quality. So far there are no pointers towards tissue-specific signal intensity behaviour. Procedure and most favourable parameters at 1 tesla are given.

Humans

[Nuclear magnetic resonance tomography with surface coils--initial experiences in orbital diagnosis].

The use of surface coils in magnetic resonance imaging of the orbit leads to an increase in spatial resolution. With the first 14 patients in whom we used the method we obtained detailed images of the orbital topography, especially in cases with tumors and foreign bodies, but the method proved to be little use in finding minimal tissue changes of the muscles or of the optic nerve. The use of oblique views without moving the patients, enables the optic nerve to be imaged in one slice. Edge artefacts caused by "chemical shift" and motion artefacts caused by motion of the bulbs still diminish detail accuracy and contrast differentiation range. Since no side effects have been described so far, magnetic resonance imaging with a surface coil is a highly suitable complementary procedure in the diagnosis of orbital disease.

Eye Foreign Bodies

MR imaging of the normal shoulder.

Magnetic resonance (MR) images of the shoulders of a healthy volunteer were obtained in axial, sagittal, and coronal orientations using a 0.5-T imaging system. Multiple high-resolution spin-echo images were generated using an off-center zoom technique and a specially designed surface coil. Several anatomic structures, including the rotator cuff, long biceps tendon, articular capsule, muscles, and bones, were visualized. The coronal and sagittal views were the most useful for demonstrating the rotator cuff. MR imaging has potential as a new non-invasive tool for the evaluation of the shoulder region.

Adult

Degenerative cartilage lesions of the hip--magnetic resonance evaluation.

The capability of magnetic resonance imaging (MRI) to visualize early degenerative arthritis of the hip was investigated. The study was performed on 8 healthy students and 45 elderly volunteers. Images were obtained by using an electronically variable Helmholtz coil (switched-array coil, SAC). In order to diagnose degenerative lesions of the joint cartilage, FISP sequences with a flip angle of 70 degrees were found preferable to compared sequences. MRI-detectable signs of degenerative arthritis of the hip were narrowed joint space due to partially thinned cartilage layers, focal areas of either increased or decreased signal intensity in the hyaline cartilage, complete loss of cartilage, and signal variation in the bone marrow. MRI of the hip may be appropriate to detect early degenerative changes in the hips of young high-risk patients to facilitate therapy planning.

Aged

The design and use of a dual-frequency surface coil providing proton images for improved localization in 31P spectroscopy of small lesions.

Nuclear magnetic resonance (NMR) spectroscopy of small lesions is restricted by the difficulties of localizing the surface coil with respect to the lesion and the problem of ensuring that signal is only obtained from the lesion and not from surrounding tissue. A double-tuned coil has been developed that permits NMR proton images to be obtained from a region of interest, prior to carrying out 31P spectroscopy of the same region with the same coil, without the need for further adjustment. The coil provides a means of accurately localizing the region from which the 31P signal is obtained, whilst offering a means of accurately applying 31P signal localization methods, and the possibility of making corrections for the nonuniform sensitivity of a given surface coil. The coil makes use of two parallel resonant circuits, with independent rf connections, but sharing a common coil. Simulated shorted and open circuit lambda /4 cables are used, respectively, to open circuit each circuit at the resonant frequency of the other circuit and ensure that the simulated lambda /4 line is short circuited for each circuit at the circuit's resonant frequency. At 63.6 MHz, the Q of the coil was 190 unloaded and 90 loaded, and at 25.7 MHz the Q was 210 unloaded and 140 loaded, for a 4-cm-diam coil. The coil has been used to obtain proton images and 31P spectra. A circuit employing only one input was also developed.

Humans