Effect of cigarette smoking on outcome after thrombolytic therapy for myocardial infarction.

BACKGROUND: Smoking is known to be a strong risk factor for premature atherosclerosis, myocardial infarction, and sudden cardiac death. Unexpectedly, in the reperfusion era, investigators have reported that patients who smoke have a more favorable prognosis after thrombolysis compared with non-smokers. Since smoking is associated with a relatively hyper-coagulable state, we hypothesized that the coronary occlusion responsible for infarction may be primarily thrombotic, with improved outcome relating to enhanced patency or the absence of a residual stenosis after thrombolytic therapy. METHODS AND RESULTS: To examine this issue, we evaluated 1619 patients treated with TPA, urokinase, or both in six consecutive myocardial infarction trials, of whom 878 (54%) were currently smoking. Patients underwent 90-minute and predischarge catheterizations, which were quantified blinded to the patients' smoking status. As expected, baseline fibrinogen (2.8 [2.5,3.6] versus 2.7 [2.4,3.5] g/dL, P = .003) and hematocrit (44% [41%, 47%] versus 43% [40%, 45%], P = .0001) levels were greater in smokers. Although there were no differences between smokers and nonsmokers with regard to 90-minute patency (73% versus 74%), smokers were more likely to have TIMI-3 flow (41.1% versus 34.6%, P = .034), with a larger minimum lumen diameter of the infarct stenosis both acutely (0.82 [0.51, 1.11] versus 0.72 [0.43, 1.04] mm, P = .0432) and at follow-up (1.2 [0.8, 1.74] versus 1.0 [0.7, 1.5], P = .002). Although smokers tended to have reduced in-hospital mortality compared with nonsmokers in univariate analysis (4.0% versus 8.9%, P = .0001), after adjustment for baseline differences between smokers and nonsmokers in age (54 [47, 62] versus 60 [54, 68] years, P < .0001), inferior infarct location (60% versus 53%, P < .0001), three-vessel disease (16% versus 22%, P < .001), and baseline ejection fraction (53% [44%, 60%] versus 50% [42%, 58%], P = .0069), smoking history was of no independent prognostic significance. CONCLUSIONS: Therefore, smokers have a relatively hypercoagulable state, documented by increased hematocrit and fibrinogen levels. Quantitative coronary angiographic analysis suggests that the mechanism of infarction in smokers is more often thrombosis of a less critical atherosclerotic lesion compared with nonsmokers. Enhanced perfusion status, as well as favorable baseline clinical and angiographic characteristics, may be responsible for the more benign prognosis of current smokers.

Adolescent↗

Intravascular ultrasound in the management of acute coronary artery dissection: a case report.

Crossing total occlusions is frequently difficult. The guidewire may enter a false lumen, thereby preventing successful balloon dilatations. We present a case of an acute arterial dissection following attempted angioplasty of a totally occluded right coronary artery. With an intravascular ultrasound probe in the false lumen, we were able to visualize a second guidewire and direct its passage into the true arterial lumen. This allowed for successful balloon dilatation and stent deployment restoring vessel patency.

Aortic Dissection↗

Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty.

Despite expectations that excimer laser ablation would result in a low incidence of coronary dissection, studies have documented a 15-20% incidence of dissection (including a 4-6% incidence of clinically significant dissection) during excimer interventions. This investigation sought to determine if pressure pulses produced by the exposure of fluid phase media (blood and contrast) to 308-nm excimer radiation might contribute to untoward outcomes. Pressure pulses generated in these media were quantitated to be > 100 atm. In vitro ablation of porcine aorta in the presence of blood or contrast resulted in tissue dissection, while ablation in pure crystalloid did not. Next, a "flush and bathe" technique designed to replace all blood and contrast with crystalloid was applied to a pilot population of 57 consecutive patients. There were no rhythm disturbances or laser-related clinically significant dissections in this group, and the clinical success rate was 95%. In summary, this report quantitates a potential etiology for excimer dissection and suggests that replacement of blood and contrast with crystalloid might improve procedural and clinical success rates.

Angioplasty, Laser↗

Percutaneous revascularization of chronic coronary occlusions: an overview.

Patients with a chronic coronary occlusion often undergo coronary angiography after weeks to months of occlusion. The published reports underestimate the extent of this problem because such patients are often arbitrarily assigned to receive medical therapy or undergo bypass surgery as a result of poor success with percutaneous revascularization and substantial restenosis. Thus, there is controversy about the role of angioplasty in this patient cohort. The goal of this overview was to evaluate the available information about angioplasty in chronic coronary occlusions. The primary indication for attempted recanalization of a chronic coronary occlusion has been symptomatic angina pectoris. Anginal status often improves after successful procedures (70% vs. 31% with a failed procedure); left ventricular function may improve; and subsequent referral for coronary artery bypass graft surgery is uncommon (3% vs. 28% in unsuccessful cases). Successful recanalization is achieved in approximately 65% of attempted procedures. Inability to cross the stenosis with a guide wire is the most common cause of procedural failure. Statistically significant predictors of procedural success include older occlusions (75% < 3 months old vs. 37% > or = 3 months old), absence of any anterograde flow through the occlusion (76% with vs. 58% without), angiographically abrupt-appearing occlusions (50% vs. 77% with tapered occlusions), presence of bridging collateral vessels (23% with vs. 71% without) and lesions > 15 mm. Procedural complications occur at a slightly lower incidence than in angioplasty of high grade subtotal stenoses. Long-term success is limited, and restenosis can be expected in > 50% of the patients. The experience with chronic total occlusions of saphenous vein bypass grafts is small, but there appear to be limited procedural success and significant procedural complications, particularly associated with distal emboli. The role of new pharmacologic agents has yet to be defined and that of new devices has been disappointing so far, but further technologic advances are on the horizon.

Angioplasty, Balloon, Coronary↗

Use of the perfusion balloon as a primary dilation device.

The development of more user-friendly and versatile perfusion balloon catheters has increased the use of prolonged dilations as a primary catheter treatment for coronary artery disease. In a multicenter randomized trial, the use of these devices to prolong initial inflation durations resulted in improved angiographic outcomes when compared with conventional short dilations. This benefit was most apparent in stenoses with complex morphology. Use of the perfusion balloon as a primary device is also appealing because of its ability to reduce anginal pain and hemodynamic changes during balloon inflation. Clinical experience suggests that primary use of the perfusion balloon may improve patient stability during procedures in which the treated segment jeopardizes a large percentage of the functional myocardium. An observational series has demonstrated the excellent outcomes which can be achieved in selected patients using a strategy of primary perfusion angioplasty with stent bailout when needed. Selection of a perfusion balloon rather than a conventional balloon as a primary device has the potential to decrease overall balloon usage approximately 25%, but the economic benefit of this strategy will depend on the cost of the perfusion balloon relative to a conventional balloon. Retrospective analyses suggest that perfusion angioplasty as a primary treatment strategy compares favorably with directional atherectomy for left anterior descending lesions. The use of coronary stents has not been directly compared to perfusion angioplasty as a primary treatment for coronary lesions, but use of a perfusion balloon as an initial device may have broader applicability, lower cost and less technical demands on the operator compared to stent deployment. In conclusion, when overall applicability, clinical outcome and cost are considered, the primary strategy of prolonged dilation with a perfusion balloon should have an important role in coronary intervention.

Angioplasty, Balloon, Coronary↗

The role of angioplasty after successful thrombolysis for acute myocardial infarction.

Soon after the efficacy of thrombolytic agents in recanalizing totally occluded arteries in the setting of AMI was shown, angiographic studies revealed a residual high-grade stenosis in a majority of these patients. To improve clinical outcome further, the role of coronary angioplasty at varying time intervals after myocardial infarction has been examined. In all studies examining the role of immediate angioplasty, no definite advantage was observed with the invasive strategy. In one study, a higher mortality rate was observed in the invasive group, whereas all studies demonstrated a significant increase in the number of non-fatal ischemic adverse events after PTCA. Although differences in clinical outcomes were noted, no difference in left ventricular function, the primary endpoint of all three studies, was demonstrated. Similar results were obtained in the randomized trials of delayed (< 48 h) or late (> 48 h) angioplasty versus conservative management. The majority of these latter trials suffer from the lack of a true control arm, as many patients in the conservative arms undergo PTCA. Observational series in conservatively treated patients after thrombolysis suggest that the coronary plaque remains unstable for several weeks after myocardial infarction. Pacifying the unstable plaque either by medical therapies or by PTCA with adjunctive therapies may in the future be the way to improve outcome in the post-infarction period. In the acute phase, aortic counterpulsation has been found to reduce ischemic events after PTCA in a randomized trial [36].(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

The impact of autoperfusion on quantitative electrocardiographic parameters of ischemia severity, extent, and "burden" during salvage of elective coronary angioplasty.

Long angioplasty inflations have been reported using an autoperfusion system that delivers oxygenated blood distal to the balloon segment. The safety and efficacy of this system has been demonstrated in anatomically selected patients. The clinical use, however, is frequently to stabilize intimal dissection in unselected patients. We reviewed 12-lead continuous electrocardiographic (ECG) recordings in 40 patients in whom prolonged salvage with autoperfusion was attempted. Sub-optimal results were stabilized in 36 of 40, while 4 patients had urgent bypass. The presence of ischemia, as > or = 100 uV ST elevation over the 12 lead ECG, and the total ST deviation over all leads over the entire inflation period (total ischemic "burden") were compared within each patient between the longest standard balloon and autoperfusion inflations. Median duration of inflation was 3.03 min. with balloon vs. 15.6 min. with autoperfusion (p < 0.00002). Of the 40 patients, 35 (87%) had ECG ischemia with balloon vs. 18 (45%) with autoperfusion (p < .00002). Median severity of peak ST deviation was 321 uV with balloon vs. 132 uV with autoperfusion (p = 0.0001). Median extent of ST elevation was 3 leads with balloon vs. 0 leads with autoperfusion (p = 0.0001). Median total ischemic burden was similar with balloon (1173 uVmin) and autoperfusion (1083 uVmin, NS) despite the fivefold longer inflation duration with autoperfusion. Thus, in patients selected by clinical necessity rather than optimal anatomy, severity and extent of ST elevation were significantly reduced, although not entirely eliminated, by autoperfusion.

Angioplasty, Balloon, Coronary↗

Transluminal extraction coronary atherectomy.

The TEC is a forward-cutting atherectomy catheter that has the unique potential to excise and aspirate atheroma, especially intraluminal thrombus. This device has been under clinical investigation for more than 6 years and received final marketing approval by the FDA for the treatment of lesions in the coronary vasculature in 1993. In the US TEC Multicenter Registry, the overall clinical and lesion successes were favorable. The success rates were similar for both native coronary vessels and saphenous vein bypass grafts. Importantly, the procedural success rates were maintained even in the presence of several unfavorable angiographic features, such as ostial location, intraluminal thrombus, and total occlusion. Further insights into the mechanisms of action of the TEC were made from studies using percutaneous angioscopy and intravascular ultrasound. Angioscopy clearly demonstrated that the TEC was indeed able to remove intraluminal thrombus, especially loosely adherent red thrombus, in a population of patients with unstable coronary syndromes. However, the TEC frequently leaves behind multiple intimal disruptions which not only create a possible nidus for restenosis but also explain the frequent hazy angiographic appearance of the vessel after TEC atherectomy. As is true for all new interventional devices, the specific niche for the TEC in interventional cardiology will best be determined in randomized clinical trials. There are several areas in which the TEC appears promising. First, this device may have a role in the management of patients with diffusely diseased saphenous vein grafts. Second, the TEC may be an effective primary therapy in lesions with intraluminal thrombus. Treatment with the TEC may then be followed by an adjunctive therapy to maximize the final vessel diameters. Finally, the TEC may be valuable in the treatment of lesions in patients with high-risk unstable coronary syndromes.

Atherectomy, Coronary↗

Current status of biodegradable stents.

Coronary angioplasty remains limited by abrupt closure and restenosis. Metallic stents are useful for suboptimal PTCA results or threatened closure and can reduce restenosis in de novo lesions. However, they are permanent devices that are used to treat a short-term problem and have only limited potential for local drug delivery. Several catheters have been designed for specific delivery of drugs or gene products. Unfortunately drug delivery efficiency and long-term retention remain problematic. To overcome these limitations and provide a scaffold for the remodeling vessel as well as a vehicle for sustained local drug delivery, bioabsorbed stents have been proposed as an alternative. This article describes the limitations of the current metallic stents, reviews the initial animal studies of polymeric stents, and proposes the biodegradable stent as a local drug delivery device to prevent restenosis and acute closure post-PTCA.

Angioplasty, Balloon, Coronary↗

Treatment of long coronary artery narrowings with long angioplasty balloon catheters.

Balloon angioplasty of long coronary artery narrowings has been associated with a lower rate of acute success, and a higher rate of acute complications and restenosis than that observed for short narrowings. Angioplasty catheters with longer length balloons (30 and 40 mm) are now available, and the objective of this study was to determine the acute and long-term success for patients with long coronary artery narrowings treated with these longer balloons. All patients with long narrowings (> or = 10 mm) treated with long balloons at 1 institution over a 1-year period were identified (93 narrowings in 89 patients), and acute and long-term outcomes were carefully documented. Procedural success (residual stenosis < or = 50%) was 97%. Abrupt closure occurred in 6% and major dissection in 11% of narrowings. Clinical success (procedural success without in-hospital death, bypass surgery or myocardial infarction) was achieved in 90% of patients. Repeat catheterization was performed in 61 patients (76% of those eligible), and restenosis was found in 50 to 55%, depending on the definition used. The treatment of long coronary artery narrowings using angioplasty catheters with longer balloons leads to high rates of acute success. However, there is a high rate of restenosis. New interventional devices for long lesions should be compared with long balloons in a randomized controlled trial.

Aged↗

In vivo validation of compensatory enlargement of atherosclerotic coronary arteries.

Necropsy examinations and epicardial ultrasound studies have suggested that atherosclerotic coronary arteries undergo compensatory enlargement. This increase in vessel size may be an important mechanism for maintaining myocardial blood flow. It also is of fundamental importance in the angiographic study of coronary disease progression and regression. The purpose of this study was to determine, using intracoronary ultrasound, whether coronary arteries undergo adaptive expansion in vivo. Forty-four consecutive patients were studied (30 men, 14 women; mean age 56 +/- 10 years). Eighty intravascular ultrasound images were analyzed (32 left main, 23 left anterior descending and 25 right coronary arteries). Internal elastic lamina area, a measure of overall vessel size increased as plaque area expanded (r = 0.57, p = 0.0001, SEE = 5.5 mm2). When the left main, left anterior descending and right coronary arteries were examined individually, there continued to be as great or greater positive correlation between internal elastic lamina and plaque area (left anterior descending: r = 0.75, p = 0.0001; right coronary arteries: r = 0.63, p = 0.0007; left main: r = 0.56, p = 0.0009), implying that each of the vessels and all in aggregate underwent adaptive enlargement. When only those vessels with < 30% area stenosis were examined, internal elastic lamina correlated well with plaque area (r = 0.79, and p = 0.0001), and for each 1 mm2 increase in plaque area, internal elastic lamina increased 2.7 mm2. This suggests that arterial enlargement may overcompensate for early atherosclerotic lesions.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Unrecognized left main coronary artery disease in patients undergoing interventional procedures.

Selective, coronary arteriographic, catheter-based, intravascular ultrasound images were obtained to determine the presence and extent of angiographically undetected or underestimated left main (LM) coronary arterial narrowing in patients receiving coronary interventional therapy. Coronary arteriograms were determined to be either normal or abnormal by visual inspection. Abnormal arteriograms were digitized and quantitated using a semiautomated edge-detection algorithm. Thirty-eight patients receiving percutaneous treatment of stenoses in the left coronary artery system were studied. Optimal LM coronary angiograms were obtained in 2 views, and intravascular ultrasound images were obtained after the coronary interventional procedure. Intravascular ultrasound detected plaque in 24 of 27 angiographically normal LM arteries (89%), whereas narrowing was observed in 11 of 11 angiographically abnormal LM arteries (100%). Eight of 38 patients (21%) had > 40% area stenosis by intravascular ultrasound. In patients with angiographic disease, there was no correlation between quantitative angiographic and ultrasound percent area stenosis (r = 0.12; p = 0.72; SEE 19%). The median plaque area was not different between angiographically normal (0.05 cm2; 0.03, 0.08 [25th, 75th percentile]) and abnormal (0.06 cm2; 0.03, 0.1) patients. The median percent area stenosis in arteriographically normal subjects (26%; 14, 32%) was less than that in abnormal ones (37%; 20, 46%) (p = 0.03). Unrecognized LM disease is widespread and often underestimated in patients with normal LM angiograms undergoing interventional procedures. Plaque area is similar for angiographically normal and insignificantly abnormal vessels. This study suggests that intravascular ultrasound overcomes the limitations of silhouette imaging and can be a clinically useful, adjunctive method to evaluate LM coronary artery disease.

Algorithms↗

Thermal-perfusion balloon coronary angioplasty: in vivo evaluation.

The goal of this study was to develop and test a new radio frequency thermal balloon system to allow longer balloon inflations at lower temperature levels than have been used with standard (laser) thermal balloon angioplasty. Radio frequency thermal capabilities were combined with perfusion balloon technology, creating a thermal-perfusion balloon catheter system for prolonged thermal inflations. Twenty-five dogs underwent thermal-perfusion angioplasty at 37 degrees, 60 degrees, or 80 degrees C for 1.5, 5, or 15 minutes with angiographic and morphologic assessments at 24 hours (n = 17) or 4-6 weeks later (n = 8). Treated segments and side branches remained patent. No coronary spasm, occlusive thrombus, or ischemic myocardial infarction occurred. Histologic extent of thermal injury in treated segments was proportional to treatment duration. Thus the thermal-perfusion balloon angioplasty system may be safely applied in canine coronary arteries. Integrating thermal and perfusion technologies provides prolonged treatment duration at moderate temperatures without excessive tissue damage.

Anesthesia, General↗

Intracoronary ultrasound predictors of adverse outcomes after coronary artery interventions.

OBJECTIVES: The purpose of this study was to determine the association between qualitative and quantitative lesion characteristics as assessed by intracoronary ultrasound imaging and adverse outcomes after coronary artery interventions. BACKGROUND: Restenosis and other adverse outcomes after coronary artery interventions may be difficult to predict from clinical or angiographic data. Intracoronary ultrasound imaging provides additional data that could prove useful. METHODS: Immediately after successful coronary artery interventions (angiographic residual stenosis < or = 50%), 69 patients underwent intracoronary ultrasound imaging. Images were assessed qualitatively for plaque composition and topography and for dissection. Quantitative data included measurement of minimal lumen diameter, lumen area, plaque area and percent area stenosis at the treatment and adjacent reference sites. Adverse outcome was defined as death, coronary bypass surgery, myocardial infarction or angiographic restenosis. RESULTS: Of the 69 patients, 1 died, 3 had bypass surgery and 1 had a myocardial infarction before planned 6-month repeat catheterization. Two patients were lost to follow-up study. Of the remaining 62 patients, 56 (90%) agreed to follow-up catheterization and 25 (45%) of the 56 had restenosis. Thus, 30 patients had an adverse outcome and 37 had no adverse event. The incidence of dissection detected by ultrasound imaging after an intervention was significantly greater in patients with than in those without a subsequent adverse event (63% vs. 35%, p < 0.05). The severity of dissection also appeared to be related to outcome (p < 0.05). Other qualitative and quantitative variables were not significantly different between the two patient groups. CONCLUSIONS: Dissection, as assessed by intracoronary ultrasound imaging after a coronary artery intervention, can identify patients at increased risk of subsequent adverse events. Additional studies are warranted to explore whether such imaging may allow modification of interventional procedures to improve outcome.

Angioplasty, Balloon, Coronary↗

Outcome after prolonged balloon inflations of greater than 20 minutes for initially unsuccessful percutaneous transluminal coronary angioplasty.

Prolonged balloon inflation with or without autoperfusion techniques is a common initial approach to major dissection or abrupt occlusion after percutaneous transluminal coronary angioplasty (PTCA). To assess such a strategy in the setting of unsuccessful angioplasty, 40 patients who underwent prolonged balloon inflations of greater than 20 minutes between January and July of 1991 after initially unsuccessful angioplasty were studied. These patients (median age 59 years) underwent PTCA for progressive or unstable angina (16[40%]), symptomatic or asymptomatic residual stenosis after myocardial infarction (10[25%]), acute myocardial infarction (3[8%]), stable angina (3[8%]), reinfarction (2[5%]), and other indications (6[15%]). The significant stenoses were primarily in the proximal and midportions of the right coronary (53%), left anterior descending (30%) and left circumflex (17%) coronary arteries. Before prolonged balloon inflation, the longest single inflation was 11 +/- 6 minutes and the total time of all inflations was 17 +/- 8 minutes (mean +/- standard deviation). Stenosis was reduced from 91 +/- 9 to 68 +/- 16% before prolonged inflation. After prolonged balloon inflation of 30 +/- 9 minutes, the residual stenosis was 47 +/- 21% (p = 0.0001 vs value before prolonged inflation). Furthermore, improvements in the appearance of filling defects or dissections, or both, occurred in 19 patients (48%). Procedural success was obtained in 32 of 40 patients (80%). Coronary bypass grafting was performed in 8 patients (20%): 4 after unsuccessful PTCA (3 emergently) and 4 electively after initially successful PTCA. Although 5 patients had creatine kinase-MB elevations greater than 20 IU/liter after the procedure, only 1 sustained a Q-wave myocardial infarction. There were no deaths in the hospital.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Coronary angioplasty performed with gradual and prolonged inflation using a perfusion balloon catheter: procedural success and restenosis rate.

The results of routine coronary angioplasty using gradual and prolonged balloon inflation with a perfusion balloon catheter were evaluated. One hundred forty patients were treated with inflation of the balloon to 6 atm over 3 minutes, with a median inflation time of 15 minutes. The procedural success rate (residual stenosis less than or equal to 50%) was 99%. In-hospital major complications occurred in five patients (3.6%), with one patient experiencing a periprocedural infarction, three patients requiring bypass surgery for abrupt closure, and one patient dying after elective bypass surgery following previous successful angioplasty of a culprit lesion. The restenosis rate in the 117 patients with angiographic follow-up (87% of those eligible) was 42%. Thus gradual and prolonged inflation using a perfusion balloon catheter resulted in a high procedural success rate and a restenosis rate similar to that reported in large studies of patients treated with standard angioplasty. These results warrant further study using a prospective randomized trial design.

Aged↗