Search PubMed⌕ Search

Biomedical subjects

H Mohammed

Publications and source records attributed to H Mohammed.

At least 55 records · Page 3Linked to original sources

Objective evaluation of surface microreplication by dental impression materials.

Twenty-two materials, including 19 dental impression elastomers, were compared in their ability to replicate microscopic detail. Some polysulfide, silicone, and polyether materials performed well. Curiously, microscopic replication ability generally correlated inversely with that expected from the nominal consistency. The test method developed appears to be a suitable microreplication evaluation standard.

Cellulose↗

Pulsed carbon dioxide laser for cartilage vaporization and subchondral bone perforation in horses. Part I: Technique and clinical results.

A carbon dioxide laser, used in a rapidly pulsed mode, was evaluated for intra-articular use in horses. Under arthroscopic guidance, a lensed 5 mm laser probe attached directly to a hand-held carbon dioxide laser was inserted into one intercarpal joint of eight horses. In four horses, a cartilage crater 1 cm in diameter was created to the level of the subchondral bone of the articular surface of the third carpal bone. In four horses, the laser was directed perpendicular to the articular surface of the third carpal bone and activated to penetrate the cartilage and subchondral bone. The intercarpal joint of the opposite carpus in each horse was subjected to arthroscopic examination and insertion of the laser probe for an equivalent time. The laser was not activated and these joints served as sham operated controls. The horses were evaluated clinically for 8 weeks, then euthanatized, and the joints were examined radiographically, grossly, and histologically. Pulsed carbon dioxide laser vaporized cartilage readily but penetrated bone poorly. Cartilage vaporization resulted in no greater swelling, heat, pain on flexion, lameness, or synovial fluid reaction than the sham procedure. Laser drilling resulted in a shallow, charred hole with a tenacious carbon residue, and in combination with the thermal damage to deeper bone, resulted in increased swelling, mild lameness and a low-grade, but persistent synovitis. The carbon dioxide laser is a useful intra-articular instrument for removal of cartilage and has potential application in inaccessible regions of diarthrodial joints. It does not penetrate bone sufficiently to have application in subchondral drilling.

Animals↗

Effect of breed and body weight on echocardiographic values in four breeds of dogs of differing somatotype.

Eighty normal dogs of four morphologically disparate breeds (Pembroke Welsh Corgi, Miniature Poodle, Afghan Hound, Golden Retriever) (twenty of each breed), were studied by echocardiography to determine the importance of breed and weight in establishing normal echocardiographic reference ranges. Echocardiographic measurements included left-ventricular chamber dimension at systole and end-diastole, right-ventricular chamber dimension at end-diastole, interventricular septal thickness at systole and end-diastole, left-ventricular free wall thickness at systole and end-diastole, E-point septal separation, aortic root dimension at end-diastole, left atrial dimension, and fractional shortening. Analyses of covariance indicated that for all measurements except right-ventricular chamber dimension, the means were significantly different among breeds, after the differences in weight were taken into account. Echocardiographic measurements are variable even within the same breed. Breed must be considered in establishing echocardiographic measurement reference ranges. Echocardiographic values for each breed are presented.

Analysis of Variance↗