Search PubMed⌕ Search

Biomedical subjects

H Meister

Publications and source records attributed to H Meister.

At least 19 recordsLinked to original sources

[Experiments on prosody perception with cochlear implants].

BACKGROUND AND OBJECTIVE: Prosody has a myriad of linguistic functions and involves specific aspects of speech, such as stress, intonation and pauses. The underlying acoustic quantities (amplitude envelope, pitch frequency, and temporal structure) can be processed and transmitted by cochlear implants (CI) only to a limited extent. At present, no adequate tests are available in the German-speaking world for evaluation of the perception of prosodic elements. Different experiments have been conducted to address several prosodic cues, and the results are to be used as a basis for appropriate tests. METHODS: Various prosodic materials were used for the experiments. Discrimination was measured for minimal pairs differing in frequency and/or duration, accents in words and phrases, questions versus statements and phrasing. Measurements were performed in ten normal-hearing subjects and five with cochlear implants. RESULTS AND CONCLUSIONS: In all test modules, the subjects with normal hearing proved to have high discrimination rates of 96-100%. The test of word stresses was problematic because the results were influenced by different confounders. The other measurements did prove to be basically suitable for use in the subjects with implants. Early results revealed that the subjects with CI had few problems with prosodic cues based on the temporal structure, the outcome being similar to that of the subjects with normal hearing in these tests. In contrast, the performance of subjects with CI in perceiving prosodic cues based on amplitude variations and, especially, on alterations in pitch frequency was worse, even though some of them achieved very good results in these tests too. These preliminary tests can form the basis for development of a German-language prosody test battery with a limited number of subtests addressing different prosodic cues.

Acoustic Stimulation↗

[A measurement system for assessing binaural masking level difference (BMLD) in children].

BACKGROUND: The binaural masking level difference (BMLD) is defined as the contrast between homophasic and antiphasic signal conditions, and can be regarded as a measure for noise suppression by the auditory system. METHODS: An adaptive two interval forced choice (IFC) measurement method was designed to assess BMLDs in children. The target tone was a 500 Hz sine pip which was masked with narrow band noise. The presentation of homo- and antiphasic signals was staggered in order to take into account artefacts--such as changes in vigilance--in a similar manner for both conditions. RESULTS: Measurement was feasible in 57 out of 85 children (6-14 y.) with suspected auditory processing disorders. Mean BMLD was 7.4(+/-4.5 SD) dB. Five children revealed a BMLD close to 0 dB suggesting that they had no advantage in signal detection for the antiphasic condition. Eleven children were not able to cope with the task of measurement. In another 17 children, the measurements did not converge to a stable threshold. DISCUSSION: The proposed measurement method was feasible with most of the children. With slight modifications of the threshold convergence, this proportion can be further increased. Whether or not the large inter-individual scatter of the results is an expression of the heterogeneous clinical clientele can only be determined when normative data are available.

Acoustic Stimulation↗

Recovery of fertility after grafting of cryopreserved germinative tissue in female rabbits following radiotherapy.

BACKGROUND: Many cancer survivors face infertility as a consequence of the aggressive treatment they must undergo. Cryopreservation of ovarian tissue before chemotherapy or radiotherapy may allow for tissue transplantation after the treatment, and restoration of fertility. We tested the potential of an orthotopic autografting of cryopreserved germinative tissue in female rabbits with ovarian failure following radiotherapy. METHODS: Ten adult multiparous female rabbits were randomly allocated into two groups, five in group I (control) and five in group II (transplant). All rabbits underwent right oophorectomy with cryopreservation of the germinative tissue, followed by sterilization of the remaining left ovary by radiotherapy. Later, group II rabbits received in the irradiated left ovary an implant of the frozen germinative tissue from the right ovary, whose small pieces were freely spread intracortically in a procedure we named 'intracortical sowing of germinative tissue' (ISGT). RESULTS: All group II rabbits conceived following spontaneous mating within 6 months of the transplant, whereas none of the remaining rabbits in group I had conceived up to 11 months after transplant. CONCLUSIONS: This study suggests that fertility can be restored in rabbits by sowing cortical tissue in a previously irradiated ovary. The clinical feasibility of this technique remains to be determined.

Animals↗

[Identifying factors before the provision of hearing aids. Results from a pilot study].

OBJECTIVE: Systematic research on factors before the provision of hearing aids is scarce. In order to identify parameters which promote or impede the use of hearing aids, a questionnaire-based survey was conducted. SUBJECTS AND METHODS: A total of 35 randomly chosen, hard of hearing adults indicated for a hearing aid were examined. The importance of speech in quiet and in noise, wearing comfort, sound quality, appearance and costs, as well as expectations, willingness to use a hearing aid and reasons for and against provision were determined. RESULTS: Speech in noise and quiet were most important, followed by comfort of wearing and appearance of the aid. Expectations towards the hearing aids were in general high. The willingness to use hearing devices was positively affected by the expectation that it would improve quality of life and negatively by the amount of social activity of the person. The main reasons against the use of hearing aids were appearance and lack of confidence in hearing aid technology. CONCLUSIONS: This pilot-study identified several parameters which might affect willingness to use hearing aids. In particular, expectations towards the aids, personal attitude towards hearing and communication problems and the appearance of hearing aids should be subject to further examination.

Adult↗

Effect of lung resection and sham surgery on the frequency of infection in alloxan-diabetic rats.

The present study was carried out in order to determine the effect of lung resection on the frequency of infections in alloxan-diabetic rats. Adult female Wistar rats were injected with alloxan (40 mg/kg, iv) to induce diabetes mellitus (group D; N = 45) or with vehicle (1.0 ml/kg, iv) to be used as controls (group C; N = 45). Thirty-six days after receiving alloxan both groups were randomly divided into three subgroups: no operation (NO; N = 15), sham operation (SO; N = 15), and left pneumonectomy (PE; N = 15). The rats were sacrificed 36 days after surgery and their lungs were examined microscopically and macroscopically. The occurrence of thoracic wall infection, thoracic wall abscess, lung abscess and pleural empyema was similar in groups D and C. In contrast, the overall infection rate was higher (P<0.05) in the diabetic rats (SO-D and PE-D subgroups, but not in the NO-D subgroup). Considering that the overall infection rate was similar in the SO-D and PE-D subgroups, we suggest that surgery but not pneumonectomy was related to the higher prevalence of infection in diabetic rats.

Alloxan↗

[Examination of binaural signal processing in normally hearing subjects using electrophysiological and psychoacoustical measurements].

BACKGROUND AND OBJECTIVE: At present, only a small number of validated, clinically usable methods for the assessment of binaural hearing capabilities exist. A proposed electrophysiological measure is the registration of the brainstem-based binaural difference potentials (BDP). PATIENTS/METHODS: The BDP is calculated as the difference between the binaurally evoked registration and the sum of the two monaural registrations. Detection and stability of the BDP were examined in 24 normally hearing adults within the framework of conventional registration of auditory brainstem responses. Furthermore, the influence of interaural time differences (ITD) on the BDP was determined. In addition, lateralization of the subjects was assessed using a psychoacoustical method. RESULTS: The components of the BDP could be detected in almost all of the subjects. Moreover, they showed sufficient test-retest reliability. The impact of ITD,which causes lateralization of the stimulus,was clearly detectable for the latencies and the amplitudes of the BDP. CONCLUSIONS: Binaural difference potentials, which are easily and reliably detectable reveal a relationship to the outcome of psychoacoustical assessment of lateralization and have the potential to provide a measure for binaural hearing capacity.

Acoustic Stimulation↗

Reaching high poloidal beta at Greenwald density with internal transport barrier close to full noninductive current drive.

In the ASDEX Upgrade tokamak, high poloidal beta up to beta(pol) = 3 at the Greenwald density with H-mode confinement has been reached. Because of the high beta, the plasma current is driven almost fully noninductively, consisting of 51% bootstrap and 43% neutral beam driven current. To reach these conditions the discharge is operated at low plasma current ( I(P) = 400 kA) and high neutral beam heating power ( P(NBI) = 10 MW). The discharge combines an edge (H mode) and internal transport barrier at high densities without confinement-limiting MHD activities. The extrapolation to higher plasma currents may offer a promising way for an advanced scenario based fusion reactor.

Journal Article↗

[Loudness scaling in children].

BACKGROUND AND OBJECTIVE: Loudness measurements in children have been carried out using different psychoacoustical methods. Besides absolute magnitude estimation (AME) and cross modality matching (CMM) category and non-category loudness scalings have been performed. However, there is a lack of systematic evaluation in loudness scalings with children. PATIENTS/METHODS: A clinically feasible categorical method is presented which was evaluated in 10 normally hearing children of 7 to 8 years. Furthermore, measurements with hearing disabled children were performed in the framework of hearing aid evaluation. RESULTS: Normal hearing children scaled slightly louder than a group of adult subjects with normal hearing. Regarding the shape of the loudness functions measured they were very similar. Particularly, they showed a steeper course at higher levels than for low input signals. Intraindividual scatter of the loudness judgements was larger for children than for adults. However, high correlation appeared between the data across test and retest. Hence, the outcome of the scalings appears to be sufficient reliable. CONCLUSIONS: Clinical measurements confirmed that the method is appropriate for children from approximately 5-10 years. Loudness judgements became more consistent and more subtly differentiated with increasing age and decreasing hearing loss. Especially with view of hearing aid evaluation the method can give valuable indications because of the possibility to directly measure individual loudness over a broad range of levels and frequencies.

Adult↗

Using conjoint analysis to examine the importance of hearing aid attributes.

OBJECTIVE: To introduce conjoint analysis (CA) as a method to explain choice decisions of hearing aid users and to measure the contributions of different hearing aid attributes involved. DESIGN: The study was conducted using CA, a method that is well established in marketing, but has not been used for hearing aid research. CA examines the contributions (importance) various attributes make to overall preference judgements. It is based on the premises that objects (i.e., hearing aids) can be described as different combinations of several attributes. The relative importance of the attributes is estimated from integral judgements of hypothetical hearing aids. The advantages of CA are a more realistic presentation of complete products instead of isolated attributes and the consideration of trade-offs between the features. The following attributes selected from 12 features in a prestudy were included in the application: speech perception in quiet, speech perception in noise, handling, sound quality, localization, and feedback. 93 randomly chosen experienced hearing aid wearers participated in the survey. RESULTS: It was found that the attributes concerning speech perception were by far most important. Speech discrimination in quiet and in noise were almost equally significant and contributed with 56% to the preference decisions of the subjects. The remaining attributes showed values in the range of 10% to 12%. When comparing various subgroups dependent on age, sex, hearing loss, satisfaction, etc., significant differences concerning the preferences were found. Elder and female subjects attached greater importance of the attribute "handling" whereas younger patients judged "speech in noise" more important. In general, subjects with greater hearing loss considered speech intelligibility in quiet to be more important than in noisy surroundings. Moreover, sound quality seems to be a significant indicator for satisfaction with the hearing aid. CONCLUSIONS: This study proposes CA as a survey technique to examine individual preferences for hearing aids. Several assumptions about the importance of hearing aid features for different groups of users could be confirmed quantitatively. Segmentation showed valid results depending on socio-demographic and user-specific parameters. The method used and the results are of interest for audiologists as well as the hearing aid industry. They provide valuable tools for future hearing aid design and should be considered in the development of self-assessment inventories.

Correction of Hearing Impairment↗

Simultaneous attainment of high electron and ion temperatures in discharges with internal transport barriers in ASDEX upgrade

Internal transport barriers have been demonstrated to exist also under conditions with T(e) approximately T(i) approximately 10 keV and predominant electron heating of the tokamak core region. Central electron cyclotron heating was added to neutral beam injection-heated ASDEX Upgrade discharges with a preexisting internal transport barrier, established through programmed current ramping leading to shear reversal. Compared to a reference internal transport barrier discharge without electron cyclotron resonance heating, the electron heat conductivity in the barrier region was found not to increase, in spite of a fivefold increase in electron heat flux, and also angular momentum and ion energy transport did not deteriorate.

Journal Article↗

[Categorical loudness scaling within the scope of hearing aid management].

The loudness perception of patients with hearing aids was measured with a one-stage category loudness scaling procedure. Data were obtained from 102 ears and were studied primarily in older patients who represented the majority of patients with hearing disorders evaluated in our department. In all, 75% of the patients were older than 45 years and had a mean age of 58 years. The reduction of dynamics at high frequencies was considered to be typical for age-related hearing disorders and was easily quantified with loudness scaling. Findings demonstrated that prediction of recruitment was not possible from pure-tone thresholds or even together with uncomfortable loudness levels, since the slopes of the level-loudness functions revealed a high interindividual variability. In contrast, the desired compression ratio can be easily calculated with data from the loudness scaling. In this study the loudness perception of patients with mainly non-linear hearing aids fitted with customary procedures was evaluated. The benefit from the hearing aids was proven with the outcome from the loudness scaling, with testing also allowing for a better fitting of the aids.

Adult↗

[Standardized measurement of sound transmission of different middle ear prostheses].

The sound transmission properties of three different commercially available middle ear implants and the prototype of a complete middle ear prosthesis (CoMEP) were evaluated with a special measurement system that permits standardized conditions. This system uses a mechanical middle ear model (MMM) which approximates the impedances of the tympanic membrane and inner ear. The implants were fitted under defined conditions into the MMM. Displacement of the artificial stapes footplate of the MMM was measured with an optical probe. The measurements of different middle ear prostheses showed that the mass of the implant was the most important factor for optimum high frequency transmission. The lightest implant (4 mg, titanium) showed the best results. The CoMEP revealed the highest sensitivity because of a slight enlargement of the diameter of the artificial tympanic membrane. These findings show that the CoMEP is able to restore sound transmission to a normal range. In a second experiment one of the implants was fitted into the MMM with different forces. The increase of stiffness produced a slightly better high frequency transmission at the expense of low frequency sensitivity. Hence, the fitting of the implant may not be too stiff because of its loss of mobility within a significant frequency range.

Acoustic Impedance Tests↗

[Clinical comparison of a digital with an analog hearing aid].

The benefit of innovative hearing aid technology can be evaluated in clinical trials. The present study describes the comparison of a new digital hearing aid with an analogue device serving as a reference. The tests were carried out with 15 experienced hearing aid wearers. To prevent the influence of different fitting algorithms such as prescriptive or loudness-based the digital devices were not renewed fitted but their level- and frequency-depending gain was adjusted to that of the reference. Different tests concerning loudness perception (category loudness scaling) speech discrimination in noise (the Göttingen sentence test) and self-assessment of the benefit by questionnaires were performed. All tests yielded slightly better results for the digital hearing aid. The speech audiometric evaluation showed somewhat better discrimination for the test-device. The questionnaires yielded a marked preference for the digital device. Because the study was not blinded influences due to the knowledge of the subjects of testing a new technology generally can occur. On the other hand, the question arises whether present audiometric tests sufficiently consider signal processing of modern hearing systems. Furthermore, one has to take into account that only a few of the features of digital technology such as noise-reduction and feedback-cancellation were considered in this study to allow for a sensible comparison. Because of the large number of possibilities offered by digital technology additional benefit by the hearing aid can be expected.

Analog-Digital Conversion↗

Standardized measurements of the sound transmission of middle ear implants using a mechanical middle ear model.

Several ways to evaluate the sound transmission properties of middle ear implants are now established. Besides computer-based simulations using acoustic and electrical analog circuits or finite element analysis, measurements can be performed with temporal bone preparations. Experiments with these preparations consider various anatomical properties, but a large number of parameters influence the outcome of measurements. To facilitate standardized measurements, a mechanical middle ear model was developed that allows comparison of the transfer function of middle ear implants on defined conditions. The model approximates the impedances of the tympanic membrane and inner ear with the aid of thin, flexible membranes. The implants are fit between the membranes, and displacement at an artificial stapes foot-plate is measured with an optical probe. Fundamental influences on the sound transmission properties of nine different middle ear implants (total ossicular replacement prostheses) were examined. Although the material and shape were different, some of the prostheses revealed very similar transfer functions. The mass of the implant showed the largest influence on sound conduction. With a higher mass, the frequency area above approximately 1 kHz was found to be significantly deteriorated. The lightest implant used was 4 mg and showed the best overall results. These findings show that middle ear prostheses should be as light as possible for optimum high-frequency transmission.

Acoustics↗

Malignant fibrous histiocytoma (MFH). A comparison of MFH in man and animals. A critical review.

This review gives information about localization and types of MFH in man and animals such as mouse, rat, cat, dog, opossum, cattle, horse and birds [e.g. mallard (a wild duck)]. Furthermore, this paper reports about cell culture dealing with MFH. The aim of this publication is to show that MFH originates from a primitive mesenchymal stem cell, fibroblastoid cell and fibroblasts. Histiocytes are, according to the literature in a small amount constituents of MFH and are reactive cells or without any meaning. In our own studies using rats [strain: Chbb: THOM (SPF)] the characteristic storiform or cartwheel pattern of tumour cells were evident. The cells were elongated, rich in endoplasmic reticulum and possessed no or very few lysosomes. The cells were predominantly fibroblasts and fibroblastoid cells. These cells were intermingled with giant cells. In other species mentioned above, the MFH showed very similar histological features. Our own results and findings obtained from the literature support our concept that the MFH represents a primitive phenotype or pleomorphic sarcoma which may differentiate in one or more directions. Histiocytes are not a neoplastic component.

Animals↗

[Measuring vibration properties of middle ear implants with the mechanical middle ear model. Initial results].

With the aid of a mechanical middle ear model (MMM) the sound transmission properties of different middle ear implants were investigated. Input of the MMM involved a broad-band signal from 100 to 5000 Hz that was supplied by a miniaturized loudspeaker. Displacement of an artificial stapes footplate was measured by a fiberoptic probe. The transfer functions of four different total ossicular replacement prostheses (TORPs) of different materials and shapes were compared. Three of the devices revealed similar transfer functions which corresponded to the typical curve of the normal middle ear. One of the prostheses demonstrated a high-frequency deterioration of approximately 5 dB. This effect was explained by a 3- to 6-times higher mass of the implant when compared to the others. Altogether, the weight of the prosthesis seems to have the most marked impact on sound transmission to the inner ear, whereas stiffness of the implant itself is less crucial as long as it can be regarded as a rigid body.

Acoustic Impedance Tests↗

Therapeutic efficacy of L-ornithine-L-aspartate infusions in patients with cirrhosis and hepatic encephalopathy: results of a placebo-controlled, double-blind study.

One hundred twenty-six patients with cirrhosis, hyperammonemia (>50 micromol/L), and chronic (persistent) hepatic encephalopathy (HE), which developed spontaneously without the existence of known precipitating factors, were enrolled in a randomized, double-blind, placebo-controlled clinical trial of intravenously administered L-ornithine-L-aspartate (OA). Patients with subclinical (grade 0, West-Haven criteria) hepatic encephalopathy (SHE), characterized by a prolonged number connection test A (NCT-A) time, and manifest HE (grades I and II, West-Haven criteria) were included in the investigation. The trial was planned as a confirmatory clinical trial OA administered in a dose of 20 g/d, as well as placebo, were dissolved in 250 mL of 5% fructose and infused intravenously for a period of 4 hours during 7 consecutive days with a superimposed protein load at the end of the daily treatment period. Primary variables were postprandial venous ammonia and NCT-A performance time measured following OA or placebo infusions to evaluate the net effect of the treatment on the prevention of the protein-induced hyperammonemia, and on parameters such as NCT-A influenced by hyperammonemia. Mental state gradation, portal systemic encephalopathy index (PSEI), and fasting ammonia levels were estimated as additional efficacy parameters. The data presented are based on the total study sample (intent-to-treat analysis), which included 63 patients in the placebo group and 63 patients in the OA group. Of the 126 patients, 114 met all the criteria for inclusion and completed the trial and treatment as outlined in the protocol (treated-per-protocol analysis). During baseline, the placebo and treatment groups were homogeneous with regard to mental states, NCT-A performance time, fasting venous blood ammonia levels, and Child-Pugh criteria. Although a slight improvement occurred in the placebo group, NCT-A performance times (P < .001) and postprandial venous ammonia concentrations in the OA-treated group showed improvements in comparison with placebo. In addition, venous fasting blood ammonia concentration (P < .01), mental state gradation (P < .001), and PSEI (P < .01), which includes the mental state gradation, NCT-A time, and postprandial venous ammonia in this trial, improved to a much higher degree in the OA group than in the placebo group. In subgroups retrospectively classified according to their initial mental state gradation, OA showed differential but uniformly significant efficacies in patients with manifest HE with respect to ammonia-lowering, improvement in NCT times, and mental state gradation. In patients with initial SHE, OA revealed differences between the medications in the psychometric test used. Adverse events consisting of mild gastrointestinal disturbances were observed in 3 of the OA-treated patients (5%). OA infusion appears to be a safe, effective treatment of chronic (persistent) manifest HE in cirrhotic patients. Additional investigations are required to assess the efficacy of OA in patients with SHE, as well as in patients with more severe grades of HE.

Adult↗

[A registration system for evaluating acusto-mechanical transmission of middle ear implants].

A measurement system was developed that permits objective comparisons of the sound conduction of middle ear implants. The implants are fitted into a mechanical middle ear model which approximates the impedances of the eardrum and the inner ear. A defined signal within the frequency range of 0-5 kHz is provided by a miniaturized loudspeaker at the input to the model and is measured by a probe microphone. Displacement of an artificial stapes footplate at the output of the model is measured by a fiberoptic probe with a sensitivity of 5 nm. The transmission function is calculated as the quotient of the output and the input signal. This system can be used to evaluate the sound-transmitting properties of different middle ear implants excepting other influences, such as surgical techniques. This work details the measurement system and demonstrates basic influences on the sound-transmission of middle ear implants.

Acoustic Impedance Tests↗