A liquid ionisation detector for digital radiography of therapeutic megavoltage photon beams.

Experiments with an ionisation detector were performed in order to determine whether it was possible to obtain high energy photon beam images for radiotherapy treatment verification. A small prototype detector with a field of view of 78 mm X 78 mm and constructed from printed circuit boards was used. The imaging area was a matrix ionisation chamber, filled with air or liquid (2,2,4-trimethylpentane). A minicomputer was used to control the data acquisition electronics and to reconstruct and restore the images. The images were displayed on a viewing console for computed tomography images. The liquid filled detector with a front-rear board separation of 1.0 mm gave the best results. The spatial resolution was about 3.8 mm with a density resolution of 0.5% for a data acquisition time of 120 s. Comparison of the liquid detector images with corresponding metal screen-film detector images showed that the image qualities were the same. An important advantage of the ionisation detector image is that grey scale modification, sharpening and smoothing by digital processing can easily be performed.

Humans↗

Digital processing of high-energy photon beam images.

The potentialities of digital megavoltage radiation field images for image quality improvement and evaluation of patient treatment setup errors are investigated. A treatment verification film is digitized with a densitometer and a treatment planning computer. The 256 X 256 picture matrix is displayed on a viewing console of a computer tomograph. The results of some processed pictures show an improved visibility of anatomical structures, which is of importance for comparison of the treatment beam images with the corresponding localization radiograph made on the simulator. In addition, automated techniques for comparison of irradiation and simulation setup are now possible.

Computers↗

Sampling methods for a matrix ionization chamber system.

To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizing voltage applied to rows of chambers. The ionization current of each column is measured by a separate amplifier. In this approach, instead of measuring row by row, more complex switching schemes can be applied for the polarizing voltage. These schemes are useful either for varying speed and spatial resolution of the imaging device or for coded sampling of the ionization signal. The former option allows for doubling or quadrupling the acquisition speed with a small loss in image quality, or for obtaining a large improvement in signal-to-noise ratio at the cost of image resolution. In the latter option, coded sampling, the image is reconstructed mathematically from the measured signals. It is shown that in this case the application of Hadamard or derived matrices for sampling leads, under certain circumstances, to a noise reduction in the reconstructed image.

Humans↗

A review of electronic portal imaging devices (EPIDs).

On-line electronic portal imaging devices are beginning to come into clinical service in support of radiotherapy. A variety of technologies are being explored to provide real-time or near real-time images of patient anatomy within x-ray fields during treatment on linear accelerators. The availability of these devices makes it feasible to verify treatment portals with much greater frequency and clarity than with film. This article reviews the physics of high-energy imaging and describes the operation principles of the electronic portal imaging devices that are under development or are beginning to be used clinically.

Humans↗

Radiological and functional assessment of radiation-induced lung injury in the rat.

The purpose of this study is to develop an experimental model to measure localized radiation-induced lung injury using multiple end-points including breathing frequency, high-resolution computed tomography (CT), and radionuclide perfusion. The rats were anesthetized and the right lung irradiated with a single dose of 18 Gy using 200-kVp x-rays. The lung function of the animals was measured every 2 weeks after irradiation with the breathing rate assay. CT scanning and radionuclide lung perfusion assay were performed prior to and 2, 4, 10, 16, and 34 weeks after irradiation. Significant elevation in breathing rate occurred after 16 weeks, with a maximal increase between 22 and 28 weeks. An increase in the right lung density started 4 weeks after irradiation. Regional measurements indicated a relatively uniform increase in density at 4 and 10 weeks, while foci of high-density areas were observed at the later time points. Changes in rat lung volume indicated shrinkage of the irradiated right lung and accompanying compensatory hypertrophy of the shielded left lung. Radionuclide perfusion assay showed significant decrease in relative blood flow in the irradiated right lung 4 weeks after hemithoracic irradiation. Changes in breathing rate provide an index of overall lung function while changes in lung density, volume, and perfusion are of particular importance for evaluating loco-regional differences in lung sensitivity. This study is the first demonstration that CT can be used to measure volume changes after thoracic irradiation in rats.

Animals↗