Search PubMed⌕ Search

Biomedical subjects

H Matsumura

Publications and source records attributed to H Matsumura.

At least 19 recordsLinked to original sources

Effectiveness of two-liquid silane primers on bonding sintered feldspathic porcelain with a dual-cured composite luting agent.

The purpose of the current study was to evaluate the effect of two-component ceramic primers on the bond strength of a composite material joined to a sintered porcelain material. Two sizes of porcelain discs (VMK 68; 10 and 8 mm in diameter by 2.5 mm thick) were ground (No. 1000 SiC), and surface-conditioned using one of the following systems: (i) unprimed, (ii) Liquid A of the Porcelain Liner M material (PLM-A), (iii) Liquid B of Porcelain Liner M (PLM-B), (iv) Liquids A and B of Porcelain Liner M (PLM-AB), (v) Liquid A of the Tokuso Ceramics Primer material (TCP-A), (vi) Liquid B of Tokuso Ceramics Primer (TCP-B) and (vii) Liquids A and B of Tokuso Ceramics Primer (TCP-AB). All specimens were bonded with the Bistite II dual-cured composite luting agent, and shear bond strengths were determined both after 24 h immersion in water and after subsequent thermocycling (4-60 degrees C, 1 min each, 20,000 cycles). Of the seven groups assessed, two groups (PLM-AB and TCP-AB) showed the greatest bond strength both before (30.7 MPa for PLM-AB and 29.7 MPa for TCP-AB) and after (19.7 MPa for PLM-AB and 22.4 MPa for TCP-AB) thermocycling (P < 0.05). No significant differences were found between the PLM-AB and TCP-AB groups regardless of the application of thermocycling (P > 0.05). It can be concluded that both of the acid-catalysed two-liquid ceramic primers showed superior bonding to the unhydrolysed single-liquid silane agents (PLM-B and TCP-A) when the feldspathic porcelain was bonded with the Bistite II luting composite.

Analysis of Variance↗

Comparative strength of metal-ceramic and metal-composite bonds after extended thermocycling.

The relative strengths of ceramic-to-metal and composite-to-metal bonds were compared after prolonged thermocycling. A total of 104 cast discs were produced from a gold alloy (Pontor LFC). A ceramic material (Duceragold) was fused to 24 discs to assess the strength of the metal-ceramic bond. An indirect composite material (New Metacolor Infis) was bonded to the remaining discs after surface preparation by Rocatec tribochemical coating, tin plating and priming with a phosphate conditioner [10-methacryloyloxydecyl dihydrogen phosphate (MDP), Cesead II], priming with a thione conditioner (V-Primer) or no treatment (unprimed control). Shear bond strengths were determined before and after thermocycling at 20,000 and 100,000 cycles. Pre-thermocycling bond strengths were ranked in the order: metal-ceramic (40.5 MPa); Rocatec treatment (33.1 MPa) and tin plating-MDP (31.0 MPa); V-Primer (20.9 MPa); and control (11.9 MPa). The bond strengths of the first three groups were not significantly different after 20,000 thermocycles, whereas those of the V-Primer and control groups were significantly reduced. After extended thermocycling (100,000 cycles) the metal-ceramic group had the highest mean shear bond strength (28.5 MPa; P < 0.05), followed by the Rocatec (23.9 MPa) and tin plating-MDP (22.1 MPa) groups. The metal-ceramic bond was the most durable, although its strength was reduced by 29.6% after extended thermocycling. On the basis of these results, we recommend the Rocatec and tin plating-MDP systems for composite-to-metal bonding. Metal-ceramic bonding, however, is superior to metal-composite bonding within the limitation of the current experiment.

Analysis of Variance↗

Serial Analysis of Gene Expression (SAGE) of Magnaporthe grisea: genes involved in appressorium formation.

Treatment with cyclic AMP (cAMP) induces appressorium formation in the phytopathogenic fungus Magnaporthe grisea, the causative agent of rice blast disease. In a search for the M. grisea genes responsible for appressorium formation and host invasion, SAGE (Serial Analysis of Gene Expression) was carried out using mRNA isolated from fungal conidia germinating in the presence and absence of cAMP. From cAMP-treated conidia 5087 tags including 2889 unique tags were isolated, whereas untreated conidia yielded 2342 unique tags out of total of 3938. cAMP treatment resulted in up- and down-regulation of genes corresponding to 57 and 53 unique tags, respectively. Upon consultation of EST/cDNA databases, 22 tags with higher representation in cAMP-treated conidia were annotated with putative gene names. Furthermore, 28 tags corresponding to cAMP-induced genes could be annotated with the help of the recently published genome sequence of M. grisea. cAMP-induced genes identified by SAGE included many genes that have not been described so far, as well as a number of genes known to be involved in pathogenicity, e.g. MPG1, MAS1 and MAC1. RT-PCR of 13 randomly selected genes confirmed the SAGE results, verifying the fidelity of the SAGE data.

Base Sequence↗

Properties of dual-curable luting composites polymerized with single and dual curing modes.

The purpose of this study was to evaluate the influence of visible-light exposure on water absorption, solubility and colour stability of dual-curable luting composites. Using eight dual-curable luting composites (2bond2, Bistite II, G-CERA Cosmotech II, Imperva Dual, Linkmax, Lute-It, Panavia Fluoro Cement and Variolink II), disk specimens were prepared by the following two methods: (i) dual-cured specimens; exposed with visible-light from a light-curing unit, and (ii) chemical-cured specimens; chemically polymerized without exposure. Five specimens were produced for each material and curing mode. Water absorption and solubility were determined according to standardized testing methods, and the data were compared using analysis of variance (ANOVA) and contrasts. With regard to colour stability, the colour difference (DeltaE*) values between 24 h and the other immersion periods (1, 2, 3, 4, 8, 12, 16, 20 and 24 weeks) were calculated and then analysed by repeated measure ANOVA. The dual-cured specimens exhibited significantly lower solubility values than the chemical-cured specimens except for the Lute-It material. The dual-cured Linkmax material exhibited the lowest solubility (0.51 +/- 0.01 microg mm(-3)) and the lowest DeltaE* value after 24 weeks (2.64 +/- 0.39). The dual-curable luting composites should be light-exposed after seating of restorations in order to reduce water absorption and solubility, and to improve colour stability.

Absorption↗

Adhesive bonding of super-elastic titanium-nickel alloy castings with a phosphate metal conditioner and an acrylic adhesive.

The purpose of the current study was to evaluate the bonding characteristics of super-elastic titanium-nickel (Ti-Ni) alloy castings. Disk specimens were cast from a Ti-Ni alloy (Ti-50.85Ni mol%) using an arc centrifugal casting machine. High-purity titanium and nickel specimens were also prepared as experimental references. The specimens were air-abraded with alumina, and bonded with an adhesive resin (Super-Bond C & B). A metal conditioner containing a phosphate monomer (Cesead II Opaque Primer) was also used for priming the specimens. Post-thermocycling average bond strengths (MPa) of the primed groups were 41.5 for Ti-Ni, 30.4 for Ti and 19.5 for Ni, whereas those of the unprimed groups were 21.6 for Ti, 19.3 for Ti-Ni and 9.3 for Ni. Application of the phosphate conditioner elevated the bond strengths of all alloy/metals (P < 0.05). X-ray fluorescence analysis revealed that nickel was attached to the debonded resin surface of the resin-to-nickel bonded specimen, indicating that corrosion of high-purity nickel occurred at the resin-nickel interface. Durable bonding to super-elastic Ti-Ni alloy castings can be achieved with a combination of a phosphate metal conditioner and a tri-n-butylborane-initiated adhesive resin.

Adhesives↗

Properties of a new photo-activated composite polymerized with three different laboratory photo-curing units.

This study determined the hardness, solubility and curing depth of a new photo-activated composite polymerized with three different laboratory photo-curing units for the purpose of evaluating the post-curing properties of the material. A new photo-activated composite material for both direct and indirect applications (DiamondCrown) was polymerized with three photo-curing units equipped with the following light sources: (i) two halogen lamps (DiamondLite-VL. Halogen Light Curing Booth); (ii) two metal halide lamps (Hyper LII) and (iii) two xenon stroboscopic tubes (UniXS II). Knoop hardness, water solubility and curing depth were determined for groups of five specimens according to standardized testing methods. All data were compared using analysis of variance (anova) and Scheffe's S intervals (P < 0.05). The Knoop hardness number (KHN) generated with the metal halide unit (63.3 +/- 2.4 KHN) was statistically (P < 0.05) greater than those produced by the other two curing units. Water solubility values for both the halogen unit (2.5 +/- 0.5 microg mm(-3)) and the metal halide unit (2.5 +/- 0.5 microg mm(-3)) were significantly (P < 0.05) lower than for the xenon unit (3.8 +/- 0.5 microg mm(-3)). Of the three photo-curing units, the metal halide curing-unit consistently exhibited the greatest depth of cure. The composite material appears to be reliable, although its post-curing properties were found to be influenced by the type of curing unit.

Analysis of Variance↗

Overexpression of Bax inhibitor suppresses the fungal elicitor-induced cell death in rice (Oryza sativa L) cells.

Treatment of suspension-cultured cells of rice (Oryza sativa L.) with cell wall extract of rice blast fungus (Magnaporthe grisea) elicits a rapid generation of H2O2, alkalinization of culture medium, and eventual cell death. To elucidate genes involved in these processes, we exploited SAGE (Serial Analysis of Gene Expression) technique for the molecular analysis of cell death in suspension-cultured cells treated with the elicitor. Among the downregulated genes in the elicitor-treated cells, a BI-1 gene coding for Bax inhibitor was identified. Transgenic rice cells overexpressing Arabidopsis BI-1 gene showed sustainable cell survival when challenged with M. grisea elicitor. Thus, the plant Bax inhibitor plays a functional role in regulating cell death in the rice cell culture system.

Apoptosis↗

Protein adsorption at polymer-grafted surfaces: comparison between a mixture of saliva proteins and some well-defined model proteins.

Grafting a dense layer of soluble polymers onto a surface is a well-established method for controlling protein adsorption. In the present study, polyethylene oxide (PEO) layers of three different grafting densities were prepared, i.e. 10-15 nm2, 5.5 nm2 and 4 nm2 per polymer chain, respectively. The adsorption of different proteins on the PEO grafted surfaces was measured in real time by reflectometry. Furthermore, the change of the zeta-potential of such surfaces resulting from adsorption of the proteins was determined using the streaming potential method. Both the protein adsorption and the zeta-potential were monitored for 1 h after exposure of the protein solution to the surface. The adsorption pattern for a mixture of saliva proteins was compared to those observed for a number of well-defined model-proteins (lysozyme, human serum albumin, beta-lactoglobulin and ovalbumin). The results of the adsorption kinetics and streaming potential measurements indicate that the effect of the PEO layer on protein adsorption primarily depends on the size and the charge of the protein molecules. The saliva proteins are strongly blocked for adsorption, whereas the change in the zeta-potential is larger than for the other proteins (except lysozyme). It is concluded that positively charged protein molecules, having dimensions larger than those of lysozyme, are involved in the initial stage of adsorption from saliva onto a negatively charged surface.

Adsorption↗

Relation between cavity design and marginal adaptation in a machine-milled ceramic restorative system.

The purpose of the current study was to evaluate the influence of inclination of the cusp as well as convergence/divergence of the cavity wall on marginal adaptation in a machine-milled ceramic restorative system. Sixty inlay specimens were prepared from a pre-fabricated feldspathic porcelain (Vitablocs Mark 2) by means of a computer integrated manufacturing system (Cerec 2). Specimens were divided into 12 groups according to original cavity preparations consisting of four inclinations of the cusp (0 degree, 15 degrees, 30 degrees and 45 degrees) and three types of cavity form (tapered box, regular box, and undercut box). The restorations were cemented with a dual-activated luting agent (Clapearl DC) and cut into two halves with a low speed cutting saw, after which adaptation at the occlusal surface of each inlay specimen was measured with a microscope. The results showed that the inclination of the cusp did not affect adaptation of the restorations (P > 0.05), whereas the inlay specimens inserted into undercut cavity preparation exhibited significantly poor adaptation as compared with those inserted into regular and tapered cavities in two inclinations of the cusp (0 degree and 15 degrees; P < 0.05). The experimental results suggest that either regular or tapered box form cavity preparation is preferable to the undercut box form to improve occlusal marginal adaptation of the Cerec 2 ceramic restorative system.

Aluminum Silicates↗

Adhesive bonding of composite material to cast titanium with varying surface preparations.

The purpose of the present study was to evaluate the surface preparation effects of eight metal conditioners and an adhesive system on bonding between a prosthodontic composite material and cast titanium. Eight primers designed for conditioning base metal alloys (Acryl Bond, All-Bond 2 Primer B, Alloy Primer, Cesead II Opaque Primer, Eye Sight Opaque Primer, Metafast Bonding Liner, Metal Primer II, and MR Bond) as well as a surface modification technique (Siloc) were assessed. Disk specimens cast from titanium (T-Alloy H) were either primed with one of the eight primers or treated with the Siloc system, and then bonded with a light-activated composite material (Artglass). Bond durability was evaluated by thermocycling (4 and 60 degrees C, 1 min each, 20, 000 cycles). After thermocycling, two groups either primed with the Cesead II Opaque Primer material or treated with the Siloc system exhibited significantly greater bond strength (20.0 and 19.0 MPa) than the other groups (0.2-12.6 MPa, P < 0.05). These two systems are considered to be useful for improving bonding between the titanium and the composite material tested.

Adhesives↗

Influence of visible-light exposure on colour stability of current dual-curable luting composites.

This study was conducted to evaluate influence of visible-light exposure on colour stability of dual-curable luting composite. Using six dual-curable luting composites [Bistite II (BI), Clapearl DC (CL), Dicor Light Activated Cement (DI), G-Cera Cosmotech II (GC), Lute-It (LU) and Variolink II (VA), disk specimens were prepared with the following two methods: (i) dual-cured specimens, exposure with visible-light from a photo-curing unit for 120 s and (ii) chemical-cured specimens, chemically cured without exposure. Five specimens were produced for each material and curing mode. After 24 h, all specimens were immersed in distilled water at 37 degrees C for 24 weeks, during which colour accuracy was measured with a dental colorimeter. The colours characterized in the Commission Internationale d'Eclairage (CIE) L*a*b* colour space were first determined 24 h after preparation (baseline colour evaluation), and again after 1, 2, 3, 4, 8, 12, 16 and 24 weeks. The colour difference (Delta E*) values between 24 h and the other immersion periods were calculated, and then analysed by repeated measure analysis of variance (ANOVA). In addition, the Delta E* values after 24 weeks for dual-cured specimens were compared with those for chemical-cured specimens by one-way ANOVA and by contrasts for each composite (P < 0.05). The Delta E* values were influenced by the material and curing mode as well as immersion period (P=0.0001). After 24 weeks the dual-cured specimens showed significantly lower Delta E* values than the chemical-cured specimens, except for the VA material. The CL material exhibited the least colour change (1.9 +/- 0.2) among the dual-cured specimens, and the VA material showed the least (4.5 +/- 0.9) among the chemical-cured specimens after 24 weeks. Dual-curable luting composites should be polymerized with the dual modes to ensure colour stability.

Acrylic Resins↗

Effect of disinfectants containing glutaraldehyde on bonding of a tri-n-butylborane initiated resin to dentine.

The purpose of this study was to evaluate the effects of disinfectants on the bond strength of resin to dentine. The surface of bovine dentine was exposed to formaldehyde (FA) aqueous solutions, glutaraldehyde (GA) aqueous solutions, 2-hydroxyethyl methacrylate aqueous solutions (HEMA), a commercially available dentine primer (Gluma CPS desensitizer, GLUMA), isotonic sodium chloride solution (IS), and distilled water (DW), and placed in a humidor (HU) at 37 degrees C, or non-stored (baseline). All dentine surfaces were conditioned with a 10% citric acid and 3% ferric chloride solution (10-3 liquid), and then bonded to an acrylic rod with a self-curing adhesive resin (Super-Bond C&B). The mean tensile bond strengths determined 24 h after bonding were compared by analysis of variance (ANOVA) and Fisher's protected LSD test (n=5, P < or = 0.05). The exposure of dentine to IS, DW and HU for both 48 and 168 h resulted in a decrease in bond strength when compared with the baseline. The highest bond strengths after 168 h of exposure were obtained with 5% GA, 10% HEMA, and GLUMA, the values of which were equivalent to baseline and were significantly higher than that of FA. It is concluded that disinfectant pre-treatment with 5% GA or GLUMA stabilizes the bonding of tri-n-butylborane (TBB) initiated luting agent to bovine dentine conditioned with 10-3 liquid.

Acid Etching, Dental↗

Effect of silane primers and unfilled resin bonding agents on repair bond strength of a prosthodontic microfilled composite.

This study examined the effect of silane primers and bonding agents on bonding between layers of a light-activated composite material when repaired in the laboratory process. Disk specimens were prepared with the dentin portion of a composite material (Dentacolor DA-30) and abraded with a silicon carbide rotary cutting instrument. The specimens were conditioned with either one of the two silane primers (Porcelain Liner M and Silicer) or one of the two unfilled resin bonding agents (Dentacolor Opaker liquid and New Metacolor Photo Opaque liquid), or one of four combinations of two primers and two bonding agents. An intact surface with a thin air-inhibited unpolymerized layer, and an unprimed surface with only silicone carbide abrasion were also used for references. After placement of the enamel portion of the same brand of composite material (Dentacolor SA-30) on each surface of the dentin material, the specimens were light-exposed, and stored for 24 h in either dry or wet condition. Shear bond strengths were then determined with a mechanical testing device. The results showed that combined use of a silane primer and a bonding agent generally showed the greatest magnitude of bond strength regardless of material variation. The use of an unfilled resin bonding agent after application of a silane primer (Porcelain Liner M) is recommended to ensure adequate repair bonding between layers of the composite material.

Adhesives↗

Evaluation of two thione primers and composite luting agents used for bonding a silver-palladium-copper-gold alloy.

The purpose of the current study was to evaluate the bond strength and durability of two metal adhesive systems bonded to a silver-palladium-copper-gold (Ag-Pd) alloy. Disk specimens were cast from an Ag-Pd alloy (Castwell M.C. 12), air-abraded with 50 micro m grain-sized alumina, and they were bonded with two primer-cement bonding systems (Alloy Primer and Panavia Fluoro Cement; Metaltite and Bistite II). For each cement, unprimed specimens were also prepared as experimental controls. Shear bond strengths were determined both before and after thermocycling (4-60 degrees C, 1 min each, 100 000 cycles). The average post-thermocycling bond strengths in MPa (n=8) were: 39.0 for the Metaltite-Bistite II system, 32.2 for the Alloy Primer-Panavia Fluoro Cement system, 23.1 for the Bistite II material and 21.0 for the Panavia Fluoro Cement material. The use of proprietary primers, both of which contain thione functional monomer, enhanced the post-thermocycling bond strengths of both cements (P < 0.05). After thermocycling, however, the difference in bond strength between the two cements was not significant regardless of the use of the primers (P > 0.05). It is concluded that the combined use of the thione primer and the luting agent is necessary for bonding the Ag-Pd alloy examined.

Analysis of Variance↗

Surface treatment of dentin with GLUMA and iron compounds for bonding indirect restorations.

The purpose of this study was to evaluate five dentin bonding systems simulating indirect restorations. The surface of bovine and human dentin was primed with a glutaraldehyde agent (GLUMA) and placed in a humidor at 37 degrees C for 168 h. In an experimental bonding system (GLUMA/CY/SB), the surfaces were etched with phosphoric acid, primed with cytochrome c, and then bonded to an acrylic rod with a self-curing resin (4-META/MMA-TBB). Specimens using two commercially available bonding systems [All-Bond 2 (AB2) and Super-Bond C & B (10-3/SB)] and two controls with and without GLUMA (GLUMA/10-3/SB and CY/SB) were also prepared. Tensile testing revealed that the bond strengths were influenced by the bonding system, 168 h dentin exposure and their interaction, but not by the tooth origin. AB2 showed the lowest bond strength. With the 10-3/SB system, exposing the dentin to humidity resulted in a decrease in bond strength. After 168 h of exposure, no significant differences were observed between 10-3/SB and CY/SB. The most effective bonding was obtained with the bonding systems of GLUMA/10-3/SB and GLUMA/CY/SB. Improved outcome is expected with these bonding systems when building up abutment teeth with indirect restorations.

Analysis of Variance↗

Alterations of quantitative EEG and mini-mental state examination in interferon-alpha-treated hepatitis C.

We have recently observed a diffuse slowing of brain waves using serial quantitative electroencephalographic (qEEG) examinations in interferon (IFN)-alpha-treated chronic hepatitis C patients. However, it remains unclear how this alteration could be assessed. We evaluated the correlation between the qEEG changes and three tests of mental status, including the Mini-Mental State Examination (MMSE), in such patients. This is the first study to undertake a clinical evaluation of the adverse effects on brain function due to IFN. We undertook blind, prospective and serial qEEG examinations on 56 chronic hepatitis C patients at three independent hospitals. IFN-alpha was administered intramuscularly at a dose of 9 x 10(6) IU daily for the first 4 weeks and then 3 times/week for the next 20 weeks. Serial EEGs were obtained before, at 2 and 4 weeks of treatment, and after the IFN-alpha treatment. The absolute power values of each frequency band in each patient at different stages of treatment were recorded by qEEG. Each patient was assessed by the MMSE, Hamilton Rating Scale for Depression (HSD), and Hamilton Rating Scale for Anxiety (HSA). We statistically evaluated the correlations between the changes in power values and alterations of scores on the mental status tests during IFN-alpha treatment. The decreased scores observed on the MMSE ranged from 2 to 5 points at both 2 and 4 weeks of IFN-alpha treatment. There were no significant differences in age distribution for each decreased score on the MMSE. As the alteration in MMSE score during IFN treatment increased, the alteration in absolute power values for the slow waves during IFN treatment increased significantly, while that for the alpha 2 and fast waves during treatment decreased significantly. However, the changes in the HDS and HSA revealed no significant correlations. The alteration of the qEEG was reversible after the treatment. MMSE scores represent one screening method for the clinical assessment of IFN-alpha-induced alterations of brain function.

Adult↗

Membrane electropermeabilization effects of frequency and membrane surface order on liposome leakage.

Liposomes containing fluorescence marker were exposed to an alternating electric field of 80 V peak to peak square electric waves at different frequencies 0.01, 1, and 100 kHz to perturb the liposome permeation. The efflux of fluorescence dye after application of the electric field was measured by recording the fluorescence emission due to the complex formation reaction between the fluorescence dye and calcium ions in the bulk medium solution. Two independent sets of experiments were conducted: 1) calcium ions were present during electropulsation; and 2) they were added after electric field application. Two parameters, fluorescence emission intensity and increment of temperature of the solution in the chamber, were studied. The effect of membrane surface order on the fluorescence dye leakage from the liposomes was studied by addition of urea at threshold concentration before the liposomes sealed. The data demonstrate the existence of frequency dependency window at 1 kHz. Furthermore, the data were interpreted according to the theory of interactions of electromagnetic fields with highly polarized and deformed materials such as liposome particles. The urea caused an enhancement of the fluorescence dye leakage at frequency of 100 kHz. This effect could be explained as a decrease of the membrane binding rigidity due to the disordering effect of urea on the membrane lipid surface. Our conclusion is that the frequency and the membrane surface order are additional parameters that influence the processes of membrane electropermeabilization.

Animals↗