Search PubMed⌕ Search

Biomedical subjects

H M Spotnitz

Publications and source records attributed to H M Spotnitz.

At least 37 records · Page 2Linked to original sources

Diastolic properties, myocardial water content, and histologic condition of the rat left ventricle: effect of varied osmolarity of a coronary perfusate.

BACKGROUND: Although myocardial edema is known to impair diastolic filling of the left ventricle, the interrelation of edema, histologic condition, and function has not been quantitated sufficiently for extrapolation to studies of multifactorial influences on diastolic properties. METHODS: Accordingly, ACI rat hearts arrested at 4 degrees C underwent coronary artery perfusion with a cardioplegia solution that was either unaltered (288 mOsm/L, P288 group, n = 6), diluted (144 mOsm/L, P144 group, n = 6), or concentrated (380 mOsm/L, P380 group, n = 6). Postmortem left ventricular pressure-volume curves and myocardial water content were measured. Myocardial samples were fixed in varying dilutions of glutaraldehyde. After dehydration and paraffin embedding, edema was graded subjectively (0 to 5), and myocardial interstitial spaces were determined by use of a semiquantitative method. RESULTS: Mean normalized left ventricular filling volume at 20 mm Hg filling pressure in the P144 group, 189 +/- 16 microliters (SEM), was reduced versus both the P288 (278 +/- 26 microliters) and the P380 (332 +/- 18 microliters) groups (p < 0.05, ANOVA). Mean myocardial water content in the P144 group, 80.7% +/- 1%, was increased versus the P380 (76.7% +/- 0.4%, p < 0.05) but not versus the P288 group (78.4% +/- 0.8%). In hearts preserved with 2.5% glutaraldehyde, mean edema grade and interstitial space in the P144 group (4.0 +/- 0.3) were increased versus the P380 (1.8 +/- 0.3, p < 0.05) but not the P288 group (2.7 +/- 0.5). Derived linear regressions relate water content to filling volume and histologic condition. CONCLUSIONS: Coronary perfusate osmolarity is thus associated with predictable changes in myocardial water content, left ventricular filling volume, and edema. These correlations allow definition of new hypotheses for the study of cardiac allograft rejection in patients and experimental animals.

Animals↗

Effect of improved myocardial protection on edema and diastolic properties of the rat left ventricle during acute allograft rejection.

BACKGROUND: Studies of myocardial edema and diastolic dysfunction in rat heart transplantation have been flawed by ischemic injury. This study uses improved methods to prevent ischemic contracture. METHODS: Hearts of 30 ACI rats were transplanted into the abdomen of Lewis rats by use of cold University of Wisconsin solution for improved preservation. Left ventricular diastolic properties were expressed as volume at standardized pressure intervals. RESULTS: On posttransplantation day 3, mean left ventricular volume at 15 mm Hg in allografts (290 +/- 9 microl, SEM) was not significantly different vs isografts (299 +/- 32 microl), allografts on day 0 (337 +/- 28 ml) or day 1 (324 +/- 20 microl), or native hearts (334 +/- 19 microl). However, volume was reduced to 173 +/- 17 microl on day 4 and to 70 +/- 23 microl on day 5 (p < 0.05). Similar findings were obtained for volume at 5 and 10 mm Hg. Allograft myocardial water content on day 3, 76.3% +/- 5%, similar to allografts on day 0 and 1 and to isografts on day 3, increased to 77.6% +/- 8% on day 4 (NS) and 79.4% +/- 6% on day 5 (p < 0.05 vs day 0). Histologically, rejection in allografts was mild on day 3, moderate on day 4, and severe on day 5. CONCLUSIONS: Reduced left ventricular filling volume during rejection is only partially explained by edema. Abnormalities of diastolic properties previously attributed to the unloaded state of nonworking heart models may actually reflect inadequate peritransplantation myocardial protection.

Adenosine↗

The risks of reoperative coronary artery bypass in chronic ischemic cardiomyopathy: results of the CABG Patch Trial.

BACKGROUND: Coronary artery bypass grafting in patients with chronic ischemic cardiomyopathy is increasing in frequency, as is reoperative bypass. However, there exist very little data on early outcomes of patients with severe left ventricular dysfunction undergoing reoperation. Hence, we tested the following hypotheses: (1) in the presence of severe left ventricular dysfunction, repeat coronary bypass carries a higher surgical mortality than the primary operation and (2) among reoperative patients with left ventricular dysfunction, the surgical mortality is higher in those with the lowest preoperative ejection fractions (EFs). METHODS AND RESULTS: We studied 1429 patients in the CABG Patch Trial, a prospective, controlled study involving 37 centers, to determine rates of early morbidity and mortality in reoperative coronary bypass patients with a reduced EF (<36%). Among patients with an EF <25%, reoperation carried a surgical mortality of 9.3%, compared with 4.3% for first-time bypass (P=NS by chi(2) analysis). With an EF <36%, surgical mortality rates were 12.0% and 4.6% for repeat and primary bypass, respectively (nominal P<.001). Among reoperative patients, there was no difference in surgical mortality at an EF <25% compared with 25% to 35%. Compared with individuals undergoing the primary bypass, reoperative patients were less stable on leaving the operating room and were more than twice as likely to sustain a postoperative myocardial infarction, cardiogenic shock, or open chest resuscitation. CONCLUSIONS: Reoperative coronary artery bypass grafting in chronic ischemic cardiomyopathy is associated with substantially higher rates of early morbidity and mortality than the initial operation and seems to be primarily attributable to postoperative heart failure.

Aged↗

Assessment of transmyocardial perfusion in alligator hearts.

BACKGROUND: Techniques for achieving myocardial perfusion directly from the left ventricular chamber are currently under investigation. Although originally based on the anatomy of reptilian hearts, which are rich in transmural channels and reported to have a poorly developed coronary vasculature, the blood flow capacity of a transmyocardial blood supply has not been studied in these hearts. With the ultimate goal of providing insight into the potential for achieving transmyocardial perfusion in human hearts, we studied the relative contribution of transmyocardial and coronary perfusion in alligator hearts. METHODS AND RESULTS: After explanation from six American alligators, the left ventricle was instrumented, and coronary arteries were perfused with oxygenated physiological solution. Using microspheres to estimate regional myocardial perfusion in the beating hearts, we show that although the epicardium was well perfused by the coronary arteries (0.20 +/- 0.08 versus 0.07 +/- 0.01 mL.min-1.g-1 owing to flow from the ventricular chamber), a significant proportion of endocardial perfusion was from the ventricular chamber (0.21 +/- 0.07 mL.min-1.g-1 from the left ventricle versus 0.13 +/- 0.04 mL.min-1.g-1 from coronary arteries). CONCLUSIONS: A significant amount of direct transmyocardial perfusion is present in alligator hearts. The conditions that apparently permit this situation in reptilian hearts are reviewed, and their implications for aiding in the optimization of techniques for achieving transmyocardial flow in humans are discussed.

Alligators and Crocodiles↗

Myocardial edema: comparison of effects on filling volume and stiffness of the left ventricle in rats and pigs.

BACKGROUND: This study compared the adverse effects of crystalloid-induced myocardial edema on left ventricular (LV) compliance in small and large hearts. METHODS: Plegisol (289 mOsm/L) was perfused into the coronary arteries of pigs (n = 8) and 1:1 dilute Plegisol (145 mOsm/L) into the coronary arteries of rats (n = 6). Pressure-volume relations, heart weight, and water content were then determined. The pressure-volume relations were compared using an LV volume at a pressure of 10 mm Hg. RESULTS: Edema in rats was associated with significant (p < 0.05) increases in heart weight (1.1 +/- 0.0 g versus 1.4 +/- 0.1 g [average +/- standard error of the mean]) and water content (76.8% +/- 0.4% versus 81.3% +/- 0.8%), but an increase in LV stiffness (7.91 +/- 0.52 versus 9.27 +/- 1.42) and a decrease in the LV volume at 10 mm Hg (0.25 +/- 0.02 mL versus 0.14 +/- 0.05 mL) were not statistically significant. Edema in pigs was associated with statistically significant (p < 0.05) increases in LV stiffness beta (0.050 +/- 0.004 versus 0.072 +/- 0.008), heart weight (207 +/- 8 g versus 274 +/- 9 g), and water content (79.8% +/- 0.6% versus 85.3% +/- 0.6%) and a significant decrease in the LV volume at 10 mm Hg (88.4 +/- 5.8 mL versus 60.4 +/- 6.8 mL). CONCLUSIONS: Myocardial edema is associated with an increase in water content and LV stiffness and a decrease in the LV volume at 10 mm Hg in both species. In rats, however, the water content is smaller in the control state and a more hypotonic perfusate is needed to induce a given degree of edema.

Animals↗

Histologic analysis of transmyocardial channels: comparison of CO2 and holmium:YAG lasers.

BACKGROUND: Transmyocardial laser revascularization using different lasers is being tested in the treatment of refractory angina. We conducted comparative analysis of the acute and chronic myocardial effects of these different lasers. METHODS: Transmyocardial channels were made in normal dog hearts with either a holmium:yttrium-aluminum garnet or a CO2 laser. Channels were examined histologically 6 to 24 hours, 2 to 3 weeks, and 6 weeks after creation. RESULTS: Regardless of the laser source, the channels were occluded by thrombus within 6 to 24 hours. Subsequently, organization and neovascularization of the channel region occurred. Thermoacoustic damage was initially greater with the holmium:yttrium-aluminum garnet laser, but the channel appearances were indistinguishable from those made with the CO2 laser by 6 weeks. CONCLUSIONS: Histologically, the myocardial effects of the CO2 and holmium:yttrium-aluminum garnet lasers are similar and differ predominantly in the amount of acute thermoacoustic injury. Channels are rapidly occluded by thrombus and are replaced by neovascularized collagen. This suggests that the physiologic effects of these two lasers may be similar and that mechanisms other than blood flow through chronic patent channels should be considered as contributing to the clinical benefits observed with this procedure.

Animals↗

Retrograde cardioplegia preserves myocardial function after induced coronary air embolism.

Coronary air embolism is a potential complication of cardiopulmonary bypass. We compared left ventricular function before and after the administration of antegrade or retrograde cardioplegic solution in a porcine model of coronary air embolism. Nineteen pigs were placed on cardiopulmonary bypass support and cooled to 32 degrees C. The heart was initially arrested with antegrade cold blood cardioplegic solution. The aortic crossclamp was released at 30 minutes and 0.02 cc/kg body weight of air was injected into the left anterior descending artery distal to the first diagonal branch. After 5 minutes the aorta was reclamped and the animals treated with 15 ml/kg body weight of 1:4 blood cardioplegic solution delivered by the antegrade (n = 6) or retrograde (n = 7) method. Control animals (n = 6) were not treated. Changes in regional preload recruitable stroke work were used to assess left ventricular performance before and after cardiopulmonary bypass. Two control animals could not be weaned from cardiopulmonary bypass. Left ventricular function was best preserved after treatment of induced coronary air embolism with retrograde cardioplegia (90% of baseline). Coronary air embolism treatment with antegrade cardioplegia resulted in diminished left ventricular performance (68% of baseline). In control animals left ventricular contractility was significantly impaired (39% of baseline). We conclude that administration of retrograde cardioplegic solution may be an effective method of treating coronary air embolism. The favorable outcome seen with cardioplegia may be in part because of its ability to protect the ischemic myocardium while the solution mechanically dislodges air from the vascular bed.

Animals↗

Heart reduction surgery: an analysis of the impact on cardiac function.

OBJECTIVES: Reports of improved ejection fraction, coupled with decreased filling pressures, have prompted a number of centers to begin evaluating the efficacy of heart reduction surgery to ameliorate symptoms of heart failure. However, the impact of this operation on cardiac mechanics is unknown. We applied a multiple compartment elastance model to simulate the effects of excising cardiac mass on heart function. METHODS: The left ventricle was divided into two functional compartments to simulate excision of part of the wall. At multiple increments of mass reduction, the resulting end-systolic elastance, ejection fraction, stroke volume, end-diastolic pressure and volume, and diastolic stiffness were determined. RESULTS: Changes in systolic function were accompanied by offsetting changes in diastolic function; consequently, overall pump function (the Frank-Starling Relationship) was found to be depressed. The geometric rearrangement associated with this operation leads to a reduction in wall stress for a given level of pressure generation, thus implying an increase in the efficiency with which wall stress is transduced into intraventricular pressure. CONCLUSIONS: Overall pump function is depressed in the short run after heart reduction surgery. However, on the basis of theoretic arguments, heart reduction surgery may have long-term beneficial implications. Importantly, this analysis revealed that changes in parameters of ventricular function have different implications during heart reduction surgery than when such changes are observed with inotropism caused by acute pharmacologic therapy.

Heart↗

Surgical aspects of a randomized trial of defibrillator implantation during coronary artery bypass surgery. The CABG Patch Trial.

BACKGROUND: Whether prophylactic insertion of an implantable cardioverter defibrillator (ICD) improves the survival of high-risk patients undergoing coronary artery bypass graft surgery (CABG) is being assessed in the CABG Patch Trial. This report describes the surgical aspects of the study. METHODS AND RESULTS: As of February 28, 1995, 847 patients (1.6% of 54102 screened) were enrolled and eligible for randomization to CABG or CABG plus ICD. Intraoperatively, 56 were eliminated by postenrollment exclusions, 67 were judged too unstable for randomization, and 724 were randomized (80% of the goal of 900). The average preoperative ejection fraction was 0.27 +/- 0.06 (n = 724); left ventricular (LV) end-diastolic pressure averaged 22 +/- 12 mm Hg (n = 548) Cardiopulmonary bypass (CPB) time averaged 108 minutes in control subjects, 126 minutes in the ICD group. After CPB, mechanical support was employed in 23% of patients and inotropic support in 73%; shock occurred in 8% and deep sternal wound infection in 1.3%. The surgical mortality was 6%; median length of stay was 8 days. Compared with randomized patients, patients whom surgeons judged too unstable to randomize were distinguished by statistically significant increases in mechanical support after CPB (51% versus 23%, P < .05) and postoperative shock (19% versus 8%, P < .05). Also, surgical mortality was greater (9% versus 6%) but was not statistically significant. CONCLUSIONS: The initial phases of the CABG Patch Trial have been conducted with acceptable surgical mortality, morbidity, and length of stay. Surgical exclusion of some patients from randomization has been corroborated by data indicating hemodynamic instability. This trial will provide information about the risks and outcome of CABG surgery in patients with impaired LV function.

Aged↗

Does blood flow through holmium:YAG transmyocardial laser channels?

BACKGROUND: Early reports indicate that transmyocardial laser revascularization improves symptoms in patients with refractory angina. However, there is little experimental evidence of whether blood flow through channels is the mechanism of action. METHODS: Endocardial channels were made in the distribution of the left anterior descending coronary artery in canine hearts (n = 5) using a holmium:yttrium-aluminum garnet laser. Hearts were excised acutely while perfused in a retrograde fashion from a second dog so that the aortic valve always remained closed. The proximal left anterior descending coronary artery was ligated. To measure direct transmyocardial blood flow, colored microspheres were injected into the left ventricular chamber. RESULTS: The number of spheres per gram of tissue in the channel region was significantly higher than in the control region (low load, 302.5 +/- 169.0 versus 41.8 +/- 59.4; high load, 208.4 +/- 138.3 versus 5.8 +/- 11.7; both, p < 0.05). However, the estimated regional blood flow through the channels was extremely low (<0.01 mL/g/min. In the chronic setting (n = 4) (2-week survival), no flow as detected through the channels, and the endocardial entry points were closed. CONCLUSIONS: Transmyocardial blood flow does not appear to occur through channels made with the holmium:yttrium-aluminum garnet laser. It remains to be determined whether this is the case with other types of lasers.

Animals↗

Validation of right and left ventricular conductance and echocardiography for cardiac function studies.

BACKGROUND: Continuous estimation of left ventricular volume from instantaneous conductance has compared favorably with "gold standards," is less labor intensive, and provides real-time data. Little information exists, however, correlating right ventricular conductance with such gold standards or examining the effects of an electrical field generated in the opposite ventricle. METHODS: In open-chested sheep, right and left ventricular conductance, two-dimensional echocardiography, and thermodilution cardiac outputs were measured at steady-state conditions. After these measurements, postmortem pressure-volume relations, ventricular mass, and ventricular casting were performed. RESULTS: The corrected end-diastolic volume measured by conductance correlated well with volumes measured by echocardiography (r = 0.89), postmortem pressure-volume relations (r = 0.84), and casts (r = 0.85). Left ventricular end-diastolic volume measured by conductance did not differ significantly from other standards by analysis of variance. The presence of an electrical field in the opposite ventricle did not affect measured conductance in the studied ventricle. CONCLUSIONS: Conductance is useful for the measurement of right and left ventricular end-diastolic volumes in the beating heart and is not affected by the presence of an electrical field in the opposite ventricle. Hence, conductance is a useful tool in studies involving interventricular dependence and function.

Animals↗

Iatrogenic myocardial edema: increased diastolic compliance and time course of resolution in vivo.

BACKGROUND: Perfusion-induced edema reduces diastolic compliance in isolated hearts, but this effect and the time for edema to resolve after blood reperfusion have not been defined in large animals. METHODS: Edema was induced by coronary perfusion with Plegisol (750 mL, 289 mOsm/L) during a 1-minute aortic occlusion in 6 pigs. This was followed by whole blood reperfusion, inotropic support, and circulatory assistance until sinus rhythm and contractile function were restored. A control group (n = 6) was treated similarly, with 1 minute of electrically induced ventricular fibrillation and no coronary perfusion. Recorded data included electrocardiogram, left ventricular pressure and conductance, aortic flow, and two-dimensional echocardiography. Preload reduction by vena caval occlusion was used to define systolic and diastolic properties. Data were recorded at baseline and at 15-minute intervals for 90 minutes after reperfusion. RESULTS: In the edema group, average left ventricular mass (132 +/- 7 [standard error of the mean] versus 106 +/- 4 g) and ventricular stiffness constant (0.15 +/- 0.02 versus 0.05 +/- 0.01) increased after Plegisol versus baseline (p < 0.05), returning to normal after 45 minutes of reperfusion. In controls, mass (118 +/- 6 versus 116 +/- 4 g) and ventricular stiffness (0.06 +/- 0.01 versus 0.05 +/- 0.01) did not change significantly. There was no significant change in systolic function. Myocardial water content at the end of the study was not different for the two groups. CONCLUSIONS: Crystalloid-induced edema and diastolic stiffness resolve after 45 minutes in pigs. This suggests that edema caused solely by cardioplegia during cardiac operations should not cause significant perioperative ventricular dysfunction.

Animals↗

Creation of a controlled venoarterial shunt. A surgical intervention for right-side circulatory failure.

BACKGROUND: Right-side circulatory failure (RSCF), a common complication of heart transplant and left ventricular assist device recipients, results in decreased cardiac output because of diminished flow across the pulmonary circuit. We hypothesized that creation of a controlled venoarterial shunt would result in decompression of the right ventricle and improved systemic cardiac output at tolerable oxygen saturations. METHODS AND RESULTS: A venoarterial shunt was created in a large-animal model (calf, n = 6). RSCF was induced by banding the pulmonary artery. Hemodynamic measures and blood gas determinations were obtained during nonshunted and shunted states. Pulmonary artery banding increased mean right ventricular systolic pressure from 44.9 +/- 2.1 mm Hg (mean +/- SEM) to 85.9 +/- 6.9 mm Hg (P < .05, paired t test) and decreased mean aortic flow from 7.8 +/- 1.0 to 4.2 +/- 1.1 L/min (P < .05). Flow through a venoarterial shunt at approximately 40% of cardiac output resulted in a decrease in right ventricular end-systolic pressure from 85.9 +/- 6.9 to 72.1 +/- 5.6 mm Hg (P < .01, ANOVA), a decrease in mean pulmonary artery pressure from 42.9 +/- 5.0 to 37.2 +/- 3.8 mm Hg (P < .01), and an increase in aortic flow from 4.2 +/- .05 to 5.1 L/min (P < .01). Left ventricular stroke work decreased from 2.22 +/- 0.28 to 1.55 +/- 0.88 (P < .05). Carotid artery oxygen saturation did not change significantly (99.9 +/- .02 to 97.6 +/- 1.7) during shunting. CONCLUSIONS: A controlled venoarterial shunt improved hemodynamics and cardiac output in a large animal model with RSCF. This strategy may be useful in the management of transplant and left ventricular assist device recipients with perioperative RSCF.

Animals↗

Right-to-left veno-arterial shunting for right-sided circulatory failure.

BACKGROUND: Right-sided circulatory failure, a complication of heart transplantation and left ventricular assist device use, results in decreased cardiac output due to diminished flow across the pulmonary circuit. We hypothesized that creation of a controlled right-to-left shunt would result in decompression of the right ventricle and improved systemic cardiac output at tolerable oxygen saturations. We also hypothesized that a peripheral veno-arterial shunt is physiologically superior to a central shunt. METHODS: Right atrial-femoral artery and right atrial-left atrial shunts were created in a large animal model (calf). Right-sided circulatory failure was induced by banding the pulmonary artery. Hemodynamic measures and blood gas determinations were obtained during nonshunted and shunted states. RESULTS: Peripheral and central shunts resulted in decreased right-sided pressures and increased cardiac output. Arterial oxygen saturation remained greater than 90% during shunting. The peripheral shunt had the added advantage of decreasing left ventricular end-diastolic pressure and left ventricular stroke work. CONCLUSIONS: A controlled right-to-left shunt improved hemodynamics and cardiac output in a large animal model with right-sided circulatory failure. This strategy may be useful in the management of transplant and left ventricular assist device recipients with perioperative right-sided circulatory failure. Our studies also indicate that creation of a peripheral shunt has both physiologic and technical advantages over a central shunt.

Animals↗

Implantable cardioverter-defibrillator. Evaluation of clinical neurologic outcome and electroencephalographic changes during implantation.

During placement of implantable cardioverter-defibrillators, ventricular arrhythmias are induced to test the function of the devices. Although cerebral hypoperfusion and ischemic electroencephalographic changes occur in patients while implantable cardioverter-defibrillators are being tested, no investigation has assessed neurologic outcome in these patients. Nine patients having either implantation or change of an implantable cardioverter-defibrillator underwent neurologic examination and neuropsychometric tests before and after the operation. After induction of general anesthesia and insertion of implantable cardioverter-defibrillator leads (when needed), ventricular fibrillation, ventricular flutter, or ventricular tachycardia, was induced by means of programmed electrical stimulation. Implantable cardioverter-defibrillator testing continued until satisfactory lead placement was confirmed. The intraoperative electroencephalographic recording was analyzed for evidence of ischemic change. In all, an electroencephalogram was recorded during 50 periods of circulatory arrest. Mean duration of the arrest periods was 13.6 seconds. By means of conventional visual inspection of the raw electroencephalogram, high-amplitude rhythmic delta or theta, voltage attenuation, or loss of fast frequency activity was observed in 30 of the arrests. By means of an automated technique of electroencephalographic interpretation based on power spectral analysis, electroencephalographic changes were correctly identified in 26 of the arrests. The incidence of these electroencephalographic changes was dependent on the arrest duration. The mean interval from arrest onset to electroencephalographic change was 7.5 seconds (standard deviation +/- 1.8 seconds). In patients with electroencephalographic changes during multiple arrests, no downward trend in this interval was detected in later arrests and no evidence of persistent ischemic change was observed in electroencephalograms recorded after the conclusion of implantable cardioverter-defibrillator testing. Postoperative neurologic and neuropsychometric testing was completed in eight patients, none of whom exhibited a new neurologic deficit, exacerbation of a preexisting neurologic condition, or significant deterioration in neuropsychometric performance. We conclude that the brief arrest of cerebral circulation induced during insertion of an implantable cardioverter-defibrillator is not associated with permanent neurologic injury.

Adult↗

The reliability of quantitative electroencephalography as an indicator of cerebral ischemia.

The electroencephalogram (EEG) has been used to detect episodes of cerebral ischemia during various surgical procedures. Recently, computerized systems for recording and interpreting the quantitative EEG (QEEG) have been used by anesthesiologists because of their ease of application, clarity of display, and reported ability to identify ischemic EEG changes. However, the extent to which automated techniques of QEEG interpretation reliably differentiate cerebral ischemia from the confounding effects of anesthetics and other sources of "artifact" is not completely established. In this study, EEGs were recorded before and after defibrillator testing in patients undergoing implantable cardioverter defibrillator (ICD) placement and during analogous time periods in control patients undergoing abdominal surgery. EEGs were subjected to standard visual inspection by an experienced electroencephalographer and QEEG analysis with a commercially available system was used for automated EEG interpretation in order to evaluate the reliability of this quantitative technique. The CIMON technique identified episodes which met previously defined criteria for QEEG cerebral dysfunction and ischemic pattern in both groups, despite the presumed absence of cerebral ischemia in the control patients. Since there was no evidence of cerebral ischemia in the raw EEGs of either the ICD patients or the controls, these QEEG changes were not confirmed by conventional techniques of EEG interpretation. Our results suggest that caution is warranted when using automated systems for intraoperative interpretation of EEG.

Adult↗

Effects of edema on systolic and diastolic function in vivo.

Recent advances in the study of myocardial edema are reviewed. A rat model, developed for the study of diastolic properties, is differentiated from larger mammals by less myocardial water content in the control state, by less cardioplegia-induced edema, and by more rapid evolution of ischemic contracture. The model has proven useful in defining the time course of recovery from iatrogenic edema, which requires less than 15 minutes, and in defining the time course and determinants of changes in compliance during transplant rejection. In pigs, a new experimental model allows study of left ventricular (LV) mass variation and changes in systolic and diastolic properties during resolution of iatrogenic edema. Initial studies indicate that iatrogenic edema and related increases in LV stiffness resolve in less than 45 minutes in pigs, in the absence of substantial ischemic injury. No significant changes in systolic performance were demonstrable statistically, but contractility was depressed immediately after reperfusion, requiring inotropic and mechanical circulatory support. In patients, measured changes in intraoperative LV mass are small and require correction for effects of changes in LV volume to define significance.

Animals↗

Assessment of right ventricular contractile state with the conductance catheter technique in the pig.

OBJECTIVE: Since the conductance catheter method has facilitated evaluation of left ventricular contractile state in both laboratory and clinical studies, the aim of this study was to determine whether the technique is similarly useful for the right ventricle. METHODS: A series of right ventricular pressure-volume loops was obtained in seven open chest pigs during transient vena caval occlusion using a 12-electrode conductance catheter. End systolic pressure-volume relationships, stroke work-end diastolic volume relationships, and dP/dt-end diastolic volume relationships were compared at control and during infusion of dobutamine and esmolol. RESULTS: Right ventricular pressure-volume loops generated with the conductance catheter were of a shape consistent with those previously reported by other volume measurement techniques, and responded to changes in inotropic state in a predictable fashion. Dobutamine shifted the three contractile relationships leftward, whereas esmolol shifted them rightward. Comparisons of stroke volume derived with the conductance catheter and with a pulmonary artery flow probe demonstrated the ability of the conductance technique to measure relative volume changes. CONCLUSIONS: The conductance catheter provides a continuous measure of right ventricular volume that was used to detect changes in right ventricular contractile state in pigs. This represents a promising and much needed method for the evaluation of right ventricular function.

Animals↗