Search PubMed⌕ Search

Biomedical subjects

H M Kooy

Publications and source records attributed to H M Kooy.

At least 37 records · Page 2Linked to original sources

Comparison of stereotactic radiosurgery and brachytherapy in the treatment of recurrent glioblastoma multiforme.

The purpose of this study was to compare the efficacy of stereotactic radiosurgery (SRS) and brachytherapy in the treatment of recurrent glioblastoma multiforme (GBM). The patients had either progressive GBM or pathologically proven GBM at recurrence after previous treatment for a lower grade astrocytoma. Thirty-two patients were treated with interstitial brachytherapy, and 86 received treatment with stereotactic radiosurgery (SRS). The patient characteristics were similar in the two groups. Those patients treated with SRS had a median tumor volume of 10.1 cm3 and received a median peripheral tumor dose of 13 Gy. Patients treated with brachytherapy had a median tumor volume of 29 cm3. Median dose to the periphery of the tumor volume was 50 Gy delivered at a median dose rate of 43 cGy/hour. Twenty-one patients (24%) treated with SRS were alive, with a median follow-up of 17.5 months. Median actuarial survival, measured from the time of treatment for recurrence, for all patients treated with SRS was 10.2 months, with survivals of 12 and 24 months being 45 and 19%, respectively. A younger age and a smaller tumor volume were predictive of better outcome. The tumor dose, the interval from initial diagnosis, and the need for reoperation were not predictive of outcome after SRS. Five patients (16%) treated with brachytherapy were alive, with a median follow-up of 43.3 months. The median actuarial survival for all patients treated with brachytherapy was 11.5 months. Survivals of 12 and 24 months were 44 and 17%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Magnetic resonance image-directed stereotactic neurosurgery: use of image fusion with computerized tomography to enhance spatial accuracy.

Distortions of the magnetic field, such as those caused by susceptibility artifacts and peripheral magnetic field warping, can limit geometric precision in the use of magnetic resonance (MR) imaging in stereotactic procedures. The authors have routinely found systematic error in MR stereotactic coordinates with a median of 4 mm compared to computerized tomography (CT) coordinates. This error may place critical neural structures in jeopardy in sme procedures. A description is given of an image fusion technique that uses a chamfer matching algorithm; the advantages of MR imaging in anatomical definition are combined with the geometric precision of CT, while eliminating most of the anatomical spatial distortion of stereotactic MR imaging. A stereotactic radiosurgical case is presented in which the use of MR localization alone would have led to both irradiation of vital neural structures outside the desired target volume and underdose of the intended target volume. The image fusion approach allows for the use of MR imaging, combined with stereotactic CT, as a reliable localizing technique for stereotactic neurosurgery and radiosurgery.

Algorithms↗

Stereotactic radiotherapy for pediatric and adult brain tumors: preliminary report.

PURPOSE: Stereotactic radiotherapy is a new modality that combines the accurate focal dose delivery of stereotactic radiosurgery with the biological advantages of conventional radiotherapy (1.8-2.0 Gy/day using 25-30 fractions). The modality requires sophisticated treatment planning, dedicated high-energy linear accelerator, and relocatable immobilization devices. We report here our early experience using stereotactic radiotherapy for intracranial neoplasms. METHODS AND MATERIALS: Between June 1992 and September 1993, we treated 82 patients with central nervous system lesions using stereotactic radiotherapy, delivered from a dedicated 6 MV stereotactic linear accelerator. A head fixation frame provided daily relocatable setup using a dental plate for all patients over 8 years of age. A modified head frame, which does not require a mouthpiece, was used for children requiring anesthesia. The patients ranged in age from 9 months to 76 years. Thirty-three patients were children less than 21 years of age. Selection criteria for the protocol included: (a) focal, small (< 5 cm) radiographically distinct lesions known to be radiocurable (pituitary adenoma, craniopharyngioma, meningioma, acoustic neuroma, pilocytic astrocytoma, retinoblastoma), and (b) lesions located in regions not amenable to surgery or radiosurgery such as the brain stem or chiasm. Standard fractionation and conventional doses were delivered. Patients with low-grade astrocytoma, oligodendroglioma, or ependymoma were treated using a dose escalation regime consisting of conventional doses plus a 10% increase. RESULTS: Although follow-up is 16 months (range 3-16 months), posttreatment radiographic studies in 77 patients have been consistent with changes similar to those found after conventional radiation therapy. To date, reduction of up to 50% of the original volume has been noted in 19 out of 77 patients, and 4 patients had a complete response, 2 with dysgerminoma, and 1 each with astrocytoma and retinoblastoma. In 56 patients disease was either stable or the follow-up was too short for evaluation. While the follow-up is relatively short, there have been no in-field or marginal recurrences. The only unexpected radiographic findings were in three patients with pilocytic astrocytomas, who developed asymptomatic edema in the treatment volume. Accuracy in daily fractionation was excellent. In over 2000 patient setups with 41,000 scalp measurements, reproducibility was found to be within 0.41 mm (median) of baseline readings, allowing for precise immobilization throughout the treatment course. The treatment in all cases was well tolerated with minimal acute effects. Our stereotactic radiotherapy facility can provide fractionated therapy for 10-12 patients a day efficiently and accurately. CONCLUSIONS: The treatment and relocatable stereotactic head frames were well tolerated with minimal acute effects. No long-term sequelae have been noted, although the observation period is short. To fully define the role of stereotactic radiotherapy, we are conducting prospective studies to evaluate neurocognitive and neuroendocrine effects. We expect that this innovative approach will make a significant impact on the treatment of intracranial neoplasms, particularly in children.

Adolescent↗

Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy.

PURPOSE: Stereotactic radiotherapy (SRT) combines techniques of stereotactic radiosurgery (SRS) with radiation therapy fractionation schemes. Fractionation in SRT necessitates a relocatable immobilization system to precisely reproduce the patient's position at each treatment. The Gill-Thomas-Cosman (GTC) head frame is such an immobilization device compatible with the Brown-Roberts-Wells (BRW) stereotactic system. We describe this device, our modifications to the original design, the repeat position accuracy, and the daily verification procedure. METHODS AND MATERIALS: The original GTC frame was tested on volunteers. This testing led to an improved strapping system, the decision to construct the oral fixation appliance at our dental clinic, and the construction of a depth confirmation helmet to rapidly confirm the position of the frame on a daily basis. The GTC frame, at our institution, is not acceptable for children requiring anesthesia, and a new frame, the "Boston Childrens' Hospital" frame, was designed. This device uses the base ring of the GTC frame. Airway access is maintained through fixation on the nasal-glabellar region and the ear canal rather than the hard palate and upper gingiva. RESULTS: The modifications of the GTC frame and the verification protocol result in repeat positioning of the frame with respect to the patient anatomy, with a standard deviation of 0.4 mm for both the modified GTC frame and the Boston Childrens' Hospital frame. The relocatibility of the frames has been established in over 2,000 patient setups in over 60 patients to date. DISCUSSION: The GTC frame is a noninvasive and versatile fixation system that provides patient comfort, as well as accurate relocatibility for SRT. The frame is not appropriate for single fraction radiosurgery, as a large setup error (> 2 mm) for a single treatment cannot be excluded. The GTC frame is compatible with the BRW system, and treatment planning for SRT and SRS patients is identical. We currently treat 10-13 SRT patients per day with intracranial neoplasms on a dedicated stereotactic therapy unit. In addition, the Boston Childrens' Hospital frame allows the use of stereotactic therapy in the treatment of children under 6 years of age. This population will benefit especially from precise and highly focal cranial irradiation.

Brain Neoplasms↗

Image fusion for stereotactic radiotherapy and radiosurgery treatment planning.

PURPOSE: We describe an image fusion application that addresses two basic problems that previously limited the use of magnetic resonance imaging (MRI) for geometric localization in stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). The first limitation is imposed by the use of a relocatable, MRI-incompatible, stereotactic frame for stereotactic radiotherapy. The second limitation is an inherent lack of geometric fidelity in current MRI scanners that invalidates the use of MRI for stereotactic localization. METHODS AND MATERIALS: We recently developed and implemented a novel automated method for fusing computerized tomography (CT) and MRI volumetric image studies. The method is based on a chamfer matching algorithm, and provides a quality assurance procedure to verify the accuracy of the fused image set. The image fusion protocol removes the need for stereotactic fixation of the patient for the MRI study. RESULTS: The image fusion protocol significantly improves on the spatial accuracy of the MRI study. We demonstrate the effect of distortion and the effectiveness of the fusion with a phantom study. We present two case studies, an acoustic neurinoma treated with SRS, and a pilocytic astrocytoma treated with SRT. CONCLUSION: The image fusion protocol significantly improves our logistical management of treating patients with radiosurgery and makes conformal therapy practical for treating patients with SRT. The image fusion protocol demonstrates both the superior diagnostic quality and the poor geometric fidelity of MRI. MRI is a required imaging modality in stereotactic therapy. Image fusion combines the superior MRI diagnostic quality with the superior CT geometric definition, and makes the use of MRI in stereotactic therapy possible and practical.

Astrocytoma↗

Stereotactic radiotherapy: a technique for dose optimization and escalation for intracranial tumors.

Stereotactic radiosurgery offers the ability to treat relatively small volume intracranial lesions with single fraction, high dose radiotherapy while sparing surrounding tissue due to rapid fall off of dose outside of the treatment volume. Conventional radiotherapy takes advantage of the sparing effects of dose fractionation, but includes relatively large amounts of normal brain in the treatment volume the tolerance of which is dose-limiting. For some intracranial lesions it may not be optimal to treat with large single fractions due to tumor location or size. Conventional fractionated radiotherapy may not be optimum in all cases due to the necessary inclusion of normal structures. Through the development of relocatable head frames, the precision of stereotactic techniques and the biologic advantages of fractionation may be combined in stereotactic radiotherapy (SRT). We report on the treatment of 68 patients with intracranial lesions using a dedicated stereotactic linear accelerator to deliver SRT between June 1992 and June 1993. SRT was used either in order to optimize dose distribution and spare normal tissues in patients with excellent prognosis or in order to increase the dose to tumor while keeping doses to normal tissues below tolerance levels in patients with poorer prognosis (dose escalation). Histologies treated included meningioma, low grade astrocytoma, pituitary adenoma and acoustic neuroma. The most common treatment sites were the parasellar region and cavernous sinuses. Most patients (79%) had surgical debulking prior to SRT. 10-12 patients were treated daily. Patient positioning using relocatable stereotactic frames was highly precise. Acute and subacute side effects were minimal and radiographic responses have been similar to those expected with conventional radiotherapy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching.

Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentation of the corresponding feature in the other modality. A distance transform is applied to the segmented volume and a cost function is defined that operates between the contour points and the distance transform. Matching is performed by iteratively optimizing the cost function for 3D translation, rotation, and scaling of the contour points. The complete matching process including segmentation requires no user interaction and takes about 100 s on an HP715/50 workstation. Perturbation tests on clinical data with cost functions based on mean, rms, and maximum distances in combination with two general purpose optimization procedures have been performed. The performance of the methods has been quantified in terms of accuracy, capture range, and reliability. The best results on clinical data are obtained with the cost function based on the mean distance and the simplex optimization method. The accuracy is 0.3 mm for CT-CT, 1.0 mm for CT-MRI, and 0.7 mm for CT-SPECT correlation of the head. The accuracy is usually at subpixel level but is limited by global geometric distortions, e.g., for CT-MRI correlation. Both for CT-CT and CT-MRI correlation the capture range is about 6 cm, which is higher than normal differences in patient setup found on the scanners (less than 4 cm). This means that the correlation procedure seldom fails (better than 98% reliability) and user interaction is unnecessary. For CT-SPECT matching the capture range is about 3 cm (80% reliability), and must be further improved. The method has already been introduced in clinical practice.

Biophysical Phenomena↗

Tolerance of cranial nerves of the cavernous sinus to radiosurgery.

PURPOSE: Stereotactic radiosurgery is becoming a more accepted treatment option for benign, deep seated intracranial lesions. However, little is known about the effects of large single fractions of radiation on cranial nerves. This study was undertaken to assess the effect of radiosurgery on the cranial nerves of the cavernous sinus. METHODS AND MATERIALS: We examined the tolerance of cranial nerves (II-VI) following radiosurgery for 62 patients (42/62 with meningiomas) treated for lesions within or near the cavernous sinus. Twenty-nine patients were treated with a modified 6 MV linear accelerator (Joint Center for Radiation Therapy) and 33 were treated with the Gamma Knife (University of Pittsburgh). Three-dimensional treatment plans were retrospectively reviewed and maximum doses were calculated for the cavernous sinus and the optic nerve and chiasm. RESULTS: Median follow-up was 19 months (range 3-49). New cranial neuropathies developed in 12 patients from 3-41 months following radiosurgery. Four of these complications involved injury to the optic system and 8 (3/8 transient) were the result of injury to the sensory or motor nerves of the cavernous sinus. There was no clear relationship between the maximum dose to the cavernous sinus and the development of complications for cranial nerves III-VI over the dose range used (1000-4000 cGy). For the optic apparatus, there was a significantly increased incidence of complications with dose. Four of 17 patients (24%) receiving greater than 800 cGy to any part of the optic apparatus developed visual complications compared with 0/35 who received less than 800 cGy (p = 0.009). CONCLUSION: Radiosurgery using tumor-controlling doses of up to 4000 cGy appears to be a relatively safe technique in treating lesions within or near the sensory and motor nerves (III-VI) of the cavernous sinus. The dose to the optic apparatus should be limited to under 800 cGy.

Abducens Nerve↗

Dynamic field shaping for stereotactic radiosurgery: a modeling study.

PURPOSE: This work assesses the relative field shaping advantages of dynamic field shaping devices for stereotactic radiosurgery using a linear accelerator. METHODS AND MATERIALS: We selected 43 intracranial tumors (2.0-4.2 cm maximum dimension, 1.5-25.5 cc tumor volume) out of the first 64 intracranial tumors treated with radiosurgery at the Joint Center for Radiation Therapy. We modeled five field shaping devices, each including a fixed auxiliary circular collimator: (a) fixed circular collimator alone; (b) two independent parallel jaws; (c) four independent rectangular jaws; (d) four independent rotatable jaws; and (e) "ideal" multileaf collimator. We adjusted the model parameters until the minimum target isodose was 80% of the dose delivered to isocenter. We defined the treatment volume ratio as the target volume divided by the treatment volume (volume receiving at least the minimum target dose). We used the treatment volume ratio to compare the five models and the actual patient treatments. RESULTS: For 34 tumors originally treated with one isocenter, the median Treatment Volume Ratio was higher for all of the device models except the fixed circular collimator compared to the actual patient treatments. For the nine tumors originally treated with multiple isocenters, the median Treatment Volume Ratio for the actual multiple isocenter treatments was similar to that for two parallel jaws, four rectangular jaws and four rotatable jaws. Only the median "ideal" collimator treatment volume ratio was higher for these nine tumors. CONCLUSION: Simple field shaping devices have approximately 50% of the conformal advantage of an "ideal" multileaf collimator. Approximately 50% of typical radiosurgical tumors between 2 and 4 cm have field shaping advantages which exceed the geometrical uncertainties inherent in linear accelerator radiosurgery treatments. The three models, two parallel, four rectangular, or four rotatable independent jaws would improve current linear accelerator technology by providing homogeneous doses with equivalent field shaping for most tumors originally treated with inhomogeneous multiple isocenter plans (6/9 tumors in the current series).

Brain Neoplasms↗

Radiosurgery as part of the initial management of patients with malignant gliomas.

PURPOSE: Between May 1988 and May 1991, 41 patients with malignant gliomas were enrolled onto a prospective study designed to evaluate the role of radiosurgery as a component of initial management. PATIENTS AND METHODS: Thirty-seven patients underwent radiosurgery according to the protocol and were assessable for survival and complications of treatment. Diagnoses included glioblastoma multiforme (GBM) in 23 (62%) cases and anaplastic astrocytoma in 14 (38%) cases. In 20 (54%) cases, surgical resection was attempted initially, whereas 17 (46%) patients underwent biopsy only. Patients in the study group received external-beam radiotherapy that consisted of 5,940 cGy given in 33 fractions to partial brain fields that encompassed the primary tumor with a 3 to 4 cm margin. Radiosurgery, used as a technique for boosting the dose to any residual contrast-enhancing mass lesion, was given 2 to 4 weeks after the completion of conventional radiotherapy. Minimum radiosurgical doses ranged from 1,000 to 2,000 cGy (median, 1,200 cGy), whereas maximum doses ranged from 1,250 to 2,500 cGy (median, 1,500 cGy). The median tumor volume at the time of radiosurgery was 4.8 cm3 (range, 1.2 to 72 cm3). Adjuvant chemotherapy was not given. RESULTS: After a median follow-up of 19 months, only nine of 37 (24%) patients have died. Six patients (all glioblastoma multiforme) died of recurrent tumor, whereas death was attributable to complications of treatment in two cases and intercurrent disease in one case. Four patients with recurrent tumor failed at the margins of the radiosurgical treatment volume, whereas two patients progressed locally. One patient is alive with local and marginal failure. Seven (19%) patients underwent reoperation at a median time of 5 months (range, 1 to 14 months) after radiosurgery. CONCLUSION: We conclude that radiosurgery is a useful adjunct to other modalities in the initial management of patients with small, radiographically well-defined malignant gliomas.

Actuarial Analysis↗

Treatment planning for stereotactic radiosurgery of intra-cranial lesions.

Stereotactic radiosurgery of intra-cranial lesions is a treatment modality where a well defined target volume receives a high radiation dose in a single treatment. Our technique delivers this dose using a set of non-coplanar arcs and small circular collimators. We use a standard linear accelerator in our treatments, and the adjustable treatment parameters are: isocenter location, gantry arc rotation interval, couch angle, collimator field size, and dose. The treatment planning phase of the treatment determines these parameters such that the target volume is sufficiently irradiated, and dose to surrounding healthy tissue and critical, dose-limiting structures is minimized. The attachment of a BRW localizing frame to the patient's cranium combined with CT imaging (and optionally MRI or angiography) provides the required accuracy for localizing individual structures in the treatment volume. The treatment is fundamentally 3-dimensional and requires a volumetric assessment of the treatment plan. The selection of treatment arcs relies primarily on geometric constraints and the beam's eye view concept to avoid irradiating critical structures. The assessment of a treatment plan involves isodose distributions throughout the volume and integral dose-volume histograms. We present the essential concepts of our treatment planning approach, and illustrate these in three clinical cases.

Adolescent↗

Results of stereotactic brachytherapy used in the initial management of patients with glioblastoma.

Recent studies have shown a survival benefit for patients with recurrent glioblastomas treated with stereotactic brachytherapy. On the basis of these encouraging results, we began a prospective study in 1987 to evaluate the use of brachytherapy in patients with newly diagnosed glioblastoma. Patients were considered eligible for this study if they met the following criteria: Karnofsky performance status 70% or greater; tumor size not greater than 5 cm in any dimension; a radiographically well delineated, supratentorial lesion not involving the ependymal surfaces; and pathologically confirmed glioblastoma. We treated 35 such patients between 1987 and 1990 with stereotactic brachytherapy as part of their initial therapy. The treatment protocol involved surgery, partial brain external-beam radiotherapy (59.4 Gy in 33 fractions), and stereotactic brachytherapy with temporary high-activity iodine 125 sources giving an additional 50 Gy to the tumor bed. Chemotherapy was not used in the initial management of these 35 patients. To compare our results with those obtained in a matched control group, we identified 40 patients with glioblastoma treated with surgery and external radiotherapy, with or without chemotherapy, between 1977 and 1986 at our institution. These patients had clinical and radiographic characteristics that would have made them eligible for the brachytherapy protocol. Survival rates at 1 and 2 years after diagnosis were 87% and 57%, respectively, for patients receiving brachytherapy versus 40% and 12.5%, respectively, for the controls (P less than .001). We conclude that stereotactic brachytherapy improves the survival of patients with glioblastoma when it can be incorporated into the initial treatment approach. Unfortunately, only about one in four patients with glioblastoma are suitable candidates for brachytherapy at the time of initial presentation.

Adolescent↗

The verification of an inverse problem in radiation therapy.

The inverse problem in radiation therapy presents a solution for a fluence distribution based on the specification of a region of dose in a patient. We show results for one such solution based on the inversion of an integral over a function of the fluence profile of a rotating beam. We use Monte Carlo methods and numerical integrations to evaluate dose distributions obtained with the inverse method and show the limitations of this theoretical approach. Our results show that dose to a single circular region at an arbitrary position in a 2-dimensional volume can be calculated. Uniform dose to arbitrarily shaped regions cannot be calculated with this formalism, although practical solutions can still be obtained.

Humans↗

The treatment of recurrent brain metastases with stereotactic radiosurgery.

Between May 1986 and August 1989, we treated 18 patients with 21 recurrent or persistent brain metastases with stereotactic radiosurgery using a modified linear accelerator. To be eligible for radiosurgery, patients had to have a performance status of greater than or equal to 70% and have no evidence of (or stable) systemic disease. All but one patient had received prior radiotherapy, and were treated with stereotactic radiosurgery at the time of recurrence. Polar lesions were treated only if the patient had undergone and failed previous complete surgical resection (10 patients). Single doses of radiation (900 to 2,500 cGy) were delivered to limited volumes (less than 27 cm3) using a modified 6MV linear accelerator. The most common histology of the metastatic lesion was carcinoma of the lung (seven patients), followed by carcinoma of the breast (four patients), and melanoma (four patients). With median follow-up of 9 months (range, 1 to 39), all tumors have been controlled in the radiosurgery field. Two patients failed in the immediate margin of the treated volume and were subsequently treated with surgery and implantation of 125I to control the disease. Radiographic response was dramatic and rapid in the patients with adenocarcinoma, while slight reduction and stabilization occurred in those patients with melanoma, renal cell carcinoma, and sarcoma. The majority of patients improved neurologically following treatment, and were able to be withdrawn from corticosteroid therapy. Complications were limited and transient in nature and no cases of symptomatic radiation necrosis occurred in any patient despite previous exposure to radiotherapy. Stereotactic radiosurgery is an effective and relatively safe treatment for recurrent solitary metastases and is an appealing technique for the initial management of deep-seated lesions as a boost to whole brain radiotherapy.

Adenocarcinoma↗

A three-dimensional electron pencil-beam algorithm.

We describe the implementation of a three-dimensional electron-dose algorithm based on a Gaussian pencil-beam model. The algorithm calculates dose to an arbitrarily distributed set of points in a heterogeneous volume. Multiple non-coplanar beams can be positioned relative to the volume. The algorithm consists of three basic components: (i) the transport of a pencil-beam through a heterogeneous volume, (ii) the evaluation of the pencil-beam fluence at a given depth in the volume in the presence of irregular fields, and (iii) the matching of points in the volume receiving a significant fluence contribution from a pencil-beam at a given depth in the volume and the calculation of dose to those points. An efficient point-matching algorithm reduces the computation time to the level of conventional two-dimensional implementations. The algorithm uses an optimised subdivision for irregular fields, and accurately predicts output factors for irregular fields placed between the final collimators and the patient. We show comparisons between the new algorithm and conventional two-dimensional calculations using measurements and calculations for finite heterogeneities, irregular fields and output factors.

Algorithms↗

Quadtrees as a representation for irregularly shaped fields in radiotherapy applications.

The choice of data representations in treatment planning software impacts on the accuracy of the treatment plan and the total computation time. We present the quadtree data structure as one such representation for irregularly shaped fields in a three-dimensional electron pencil-beam algorithm. The quadtree subdivides the irregular field into pencil-beams of unequal size and considerably reduces the number of pencil-beams needed in the dose calculation while preserving the calculational accuracy. Small pencil-beams are concentrated around the field edges to provide optimal resolution and computational accuracy in penumbra regions. The quadtree simplifies the evaluation of the pencil-beam fluence at a given depth, and removes systematic errors present in alternative implementations. The quadtree algorithm results in a ten-fold performance improvement when compared to alternative implementations for the irregular field.

Algorithms↗

Parallel-plate ionization chamber response in cobalt-60 irradiated transition zones.

The authors study the acceptance of a Capintec parallel-plate ionization chamber. The Capintec chamber is used for dose measurements in a lead and polystyrene slab phantom irradiated with cobalt-60 gamma rays. The authors define an enhancement ratio to quantify the dose measurements. The enhancement ratio equals the ratio of dose measured with the lead slab present to dose measured under equilibrium conditions in polystyrene at equal primary beam attenuation. The measured enhancement ratio at the exit side of the lead/polystyrene interface is 25% lower than the Monte Carlo predicted enhancement ratio. The authors propose that geometric acceptance limitations of the Capintec chamber to large-angle, low-energy electrons are the cause for this difference. A Monte Carlo simulation of the Capintec chamber acceptance confirms the hypothesis.

Cobalt Radioisotopes↗

Spherical harmonic expansion of cranial surfaces.

A three-dimensional analytical technique for the representation of the cranial surface based on a spherical harmonic expansion is presented. The analytical surface representation is used in conjunction with a sample iterative ray-intersection algorithm to compute the dose calculation depth. The technique is compared to other conventional techniques and it is determined that the spherical harmonic approach of approximating the cranial surface decreases the depth calculation time by approximately a factor of 60.

Algorithms↗