Search PubMed⌕ Search

Biomedical subjects

H Lingeman

Publications and source records attributed to H Lingeman.

At least 19 recordsLinked to original sources

Selective detection and identification of phosphorylated proteins by simultaneous ligand-exchange fluorescence detection and mass spectrometry.

A ligand-exchange method for the detection and identification of phosphorylated peptides in complex mixtures is presented that is based on the characterization of phosphorylated species by solution-phase interactions with Fe(III) ions and subsequent fluorescence readout. After the separation of the peptides and digest products on a reversed-phase LC column, the flow is split between the two detection systems. One part is directed towards an electrospray mass spectrometer for direct detection and identification of all the peptides present in the sample. The other part of the flow is directed towards a ligand-exchange detection system. This system relies on the specific release of a fluorescent reporter ligand from a Fe(III)-complex in the presence of phosphorylated peptides. To recognize false positive signals due to high-affinity non-phosphorylated high-acidic peptides and other compounds which are known to be a problem in for instance immobilized metal affinity chromatography (IMAC), a second run is performed after incubation of the sample with alkaline phosphatase. A positive signal in this second run indicates a high-affinity non-phosphorylated compound. The method is illustrated using digest from a phosphorylated alpha-casein. Automated switching between MS and MS-MS was performed to obtain additional information about the compounds present in the sample. The linearity of the method was tested in the range of 0.5-80 microM of phosphorylated peptides. A limit of detection (LOD) of 0.5 microM was obtained for a mono-phosphorylated peptide. The interday (n=4) and intraday precision (n=3) expressed as relative standard deviation was better than 10%.

Caseins↗

Screening for metal ligands by liquid chromatography--ligand-exchange--electrospray mass spectrometry.

Electrospray ionization mass spectrometry is applied for the selective detection of metal ligands after a post-column continuous-flow ligand-exchange reaction. The detection is based on the specific release of a reporter ligand from a metal-reporter ligand complex by a high affinity ligand. Constant infusion and direct-injection experiments are performed to optimize the method. The on-line coupling of a liquid chromatographic separation prior to the continuous flow ligand-exchange reaction enables the screening for high affinity ligands in complex samples. The feasibility of the method is demonstrated by using several ligands with a different affinity for either Cu(II) or Zn(II) ions. The selectivity of the ligand-exchange detection method can be tuned by the choice of the reporter ligand. This is demonstrated by using either 2,2'-bipyridyl or 5-methyl-1,10-phenanthroline as reporter ligands.

Chromatography, Liquid↗

Sample preparation for peptides and proteins in biological matrices prior to liquid chromatography and capillary zone electrophoresis.

The determination of peptides and proteins in a biological matrix normally includes a sample-preparation step to obtain a sample that can be injected into a separation system in such a way that peptides and proteins of interest can be determined qualitatively and/or quantitatively. This can be a rather challenging, labourious and/or time-consuming process. The extract obtained after sample preparation is further separated using a compatible separation system. Liquid chromatography (LC) is the generally applied technique for this purpose, but capillary zone electrophoresis (CZE) is an alternative, providing fast, versatile and efficient separations. In this review, the recent developments in the combination of sample-preparation procedures with LC and CZE, for the determination of peptides and proteins, will be discussed. Emphasis will be on purification from and determination in complex biological matrices (plasma, cell lysates, etc.) of these compounds and little attention will be paid to the proteomics area. Additional focus will be put on sample-preparation conditions, which can be 'hard' or 'soft', and on selectivity issues. Selectivity issues will be addressed in combination with the used separation technique and a comparison between LC and CZE will be made.

Chromatography, Liquid↗

Systematic development of an enzymatic phosphorylation assay compatible with mass spectrometric detection.

The enzymatic peptide phosphorylation by cAMP-dependent protein kinase A (PKA) was optimized and monitored by means of electrospray ionization mass spectrometry (ESI-MS). The direct detection of phosphorylated peptides by MS renders labeling unnecessary, reduces time and labor, due to less initial sample pretreatment. In this study the phosphorylation of the peptide malantide by PKA was performed in batch and reaction compounds were detected by ESI-MS after the incubation time. The subsequent product quantitation was accomplished by using one-point normalization. Applying this set-up, optimum solvent conditions (such as salt and modifier content), concentrations of essential reaction compounds (such as cAMP, Mg2+ and ATP), and the influence of reaction properties (such as pH and reaction time) were determined. The reaction milieu has to be suitable for both, the enzymatic reaction and the mass spectrometric detection. We found that the modifier content and the pH value had to be changed after the enzymatic reaction occurred. Through the addition of methanol and acetic acid, the reaction stopped immediately and a more sensitive mass spectrometric detection could be obtained simultaneously. Furthermore, an inhibitor study was performed, testing the inhibition potency of three protein kinase A inhibitors (PKIs). IC50 values were determined and used to calculate the Ki values, that were 7.4, 19.0 and 340.0 nmol/L for PKI(6-22)amide, PKI(5-24)amide, and PKI(14-24)amide, respectively. These data vary between factor 4.4 (for PKI(6-22)amide) and 8.3 (for PKI(5-24)amide) compared to the Ki values described in literature. However, the Ki values are in good agreement with the data mainly obtained by fluorescence- or radioactivity-based methods. Nevertheless, our results indicate that ESI-MS is a realistic alternative to radioactivity and fluorescence detection in determining enzymatic activity. Furthermore we were able to illustrate its high potential as a quantitative detection method.

Adenosine Triphosphate↗

Chiral ligand-exchange chromatography as the screening method for proposed modifications in exametazime synthesis to enhance diastereoselectivity.

99M Tc (V)-d,l-HM-PAO complex is well-known radiopharmaceutical for regional cerebral blood flow imaging. The proposed modifications in exametazime, hexamethylpropyleneamine oxime (HM-PAO) (4,8-diaza-3,6,6,9-tetramethylundecane-2,10-dione bisoxime) synthesis, for reduction of intermediary reactant diiminebisoxime (DI) (4,8-diaza-3,6,6,9-tetramethylundecane-3,8-diene-2,10-dione bisoxime) concerned two reductants (NaBH(4) and KBH(4)), two solvents (ethanol and 2-propanol), and three mole ratios of reactant/reductants (1:1, 1:1.5, and 1:2). The simultaneous analysis of diastereo-enantiomeric HM-PAO content, as well as the content of starting DI, in different reduction mixtures were performed using chiral ligand-exchange chromatography (CLEC). The separation of the samples of investigated reduction mixtures, obtained in the second step of HM-PAO synthesis, has been accomplished by using an achiral sorbent (RP-18) and a chiral mobile phase (CMP) containing copper(II) complex with N,N-dimethyl-l-phenylalanine (l-DM-PhA) as initial complex for CLEC. With 12 different reduction conditions, the obtained ratios of diastereoisomers d,l-HM-PAO: meso-HM-PAO varied from 69.2:30.8 to 15.9:84.1, in comparison to the reduction in routine synthesis of HM-PAO which gives an equal mixture of diastereoisomers. The ternary mixed complexes formation recorded spectrophotometrically on addition of HM-PAO or DI to the mobile phase with binary complex Cu(l-DM-PhA)(2), due to the evidence of bathochromic shift of 46nm for lambda(max) with significant difference in absorptivity contributes to separation mechanism.

Butanones↗

Ligand-exchange detection of phosphorylated peptides using liquid chromatography electrospray mass spectrometry.

Electrospray ionization mass spectrometry (ESI-MS) is used to selectively detect analytes with a high affinity for metal ions. The detection method is based on the selective monitoring of a competing ligand at its specific m/z value that is released during the ligand-exchange reaction of a metal-ligand complex with analyte(s) eluting from a reversed-phase liquid chromatography column. The ligand-exchange reaction proceeds in a postcolumn reaction detection system placed prior to the inlet of the electrospray MS interface. The feasibility of metal affinity detection by ESI-MS is demonstrated using phosphorylated peptides and iron(III)methylcalcein blue as reactant, as a model system. Methylcalcein blue (MCB) released upon interaction with phosphorylated peptides is detected at m/z 278. The ligand-exchange detection is coupled to a C8 reversed-phase column to separate several nonphosphorylated enkephalins and the phosphorylated peptides pp60 c-src (P) and M2170. Detection limits of 2 microM were obtained for pp60 c-src (P) and M2170. The linearity of the detection method is tested in the range of 2-80 micromol/L phosphorylated compounds (r(2) = 0.9996), and a relative standard deviation of less than 8% (n = 3) for all MCB responses of the different concentrations of phosphorylated compounds was obtained. The presented method showed specificity for phosphorylated peptides and may prove a useful tool for studying other ligand-exchange reactions and metal-protein interactions.

Chromatography, Liquid↗

On-line SPE-CE for the determination of insulin derivatives in biological fluids.

An on-line SPE-CE system is described for the determination of insulin derivatives in urine, serum and plasma. By combining techniques based on different separation mechanisms, in this case reversed-phase SPE and CE, a more selective sample clean-up is obtained. The described on-line SPE-CE procedure is able to desalt and clean biological samples, resulting in more repeatable electrophoretic results as well as a good linearity for urine, serum and plasma samples spiked with insulin derivatives, thus proving the elimination of detrimental effects caused by the sample matrix. The on-line SPE-CE system was linear for urine, serum and plasma samples spiked with insulin derivatives between 5 and 80 mg/l. The repeatability in migration time was below 1% relative standard deviation (R.S.D.). The repeatability of the peak was better (<2.4% R.S.D.) when no off-line precipitation reaction (<6.2% R.S.D.) was used, proving the beneficial characteristics of on-line sample pretreatment procedures over off-line sample pretreatment procedures which are prone to sample losses and contamination.

Amino Acid Sequence↗

Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime.

The diastereo-enantio separation of isomeric mixtures of exametazime (HM-PAO) by liquid chromatography is described using an achiral sorbent (RP-18). A chiral eluent with the initial complex of Cu(II) and the optically active selector N,N-dimethyl-l-phenylalanine (l-DM-PhA), based on the ligand-exchange principle, has been applied. The separation is based on the presence of the immobilized binary complex Cu(l-DM-PhA)(2) and formation of mixed ternary complex. The optimal mole ratio of Cu(II):l-DM-PhA is 1:4, the pH should be between 4.1 and 4.2 and up to 0.8 mM of triethylamine is added for column presaturation with the initial complex. The elution order has been defined using isolated l-HM-PAO via l-HM-PAO L(+)tartrate and meso-HM-PAO obtained by repeated recrystallization from the isomeric mixture of HM-PAO. Complete resolution between all isomers (R(S) from 2.14 to 3.91) and partial resolution for meso(EE)/l-HM-PAO (R(S)=0.83) has been obtained. This means that the proposed chiral ligand-exchange chromatography (CLEC) can be used for determination of the isomeric purity of HM-PAO. This as an alternative method for resolution measurements with chiral columns.

Butanones↗

On-line SPE-RP-LC for the determination of insulin derivatives in biological matrices.

An automated and on-line solid-phase extraction (SPE)-liquid chromatography (LC) procedure is described for the determination of insulin in biological matrices. The total procedure consists of two SPEs in series, followed by RP-LC separation. During the first SPE a strong anion-exchange (SAX) cartridge (ISOLUTE, 40-90 microm, 10 x 4 mm i.d.) is used, followed by a RP-cartridge (Luna C(8), 4 x 2.0 mm i.d.). The second SPE cartridge contains the same material as the LC column and is used to transfer the sample from the SAX cartridge to the LC column. The developed system can detect 100 nmol/l insulin in aqueous samples and 200 nmol/l insulin in spiked plasma samples using UV. When electrospray ionization (ESI)-mass spectrometry (MS), was coupled with the developed system, the LODs were lowered by a factor two to 50 and 100 nmol/l for aqueous and spiked plasma samples, respectively.

Amino Acid Sequence↗

Degradation kinetics of aplidine, a new marine antitumoural cyclic peptide, in aqueous solution.

The degradation kinetics of aplidine were investigated using reversed-phase high-performance liquid chromatography combined with UV detection. Aplidine consists of at least two isomers that undergo interconversion at a low rate. Influences of pH, temperature, buffer ions and ionic strength on the degradation kinetics were studied. The log kobs) -pH profile can be divided into three parts, a proton, a solvent and a hydroxyl-catalysed section. The stability-indicating properties of the used analysis technique as well as the identities of the main degradation products were checked using gradient liquid chromatography and mass spectrometric detection. The overall degradation rate constant as a function of the temperature under acidic and alkaline conditions obeys the Arrhenius equation. No catalytic influences were observed with phosphate and carbonate buffers and, in addition, the ionic strength showed no substantial effect on the stability, as expected. Results from gradient LC-MS indicated that hydrolysis of the ester groups present in the ring structure was the main degradation route. There is no difference in degradation rate constants for the individual isomers.

Antineoplastic Agents↗

Robust and cost-effective capillary electrophoresis-mass spectrometry interfaces suitable for combination with on-line analyte preconcentration.

This paper describes several successful cost-effective attempts to couple capillary electrophoresis (CE) and mass spectrometry (MS) without make-up flow or nebulizing gas. An in-depth analysis of several interfaces using conductive spray tips was performed as well as an easy-to-prepare T-junction with direct electrode contact, the latter being the most robust interface. No coating is necessary and the spray voltage is applied through a gold wire positioned at the gap between the separation and spray capillaries. The T-junction interface is made by puncturing a small piece of transparent rubber. The on-line preconcentration CE-MS system allows immunoassay sensitivity, as is demonstrated by a calibration plot in the picomolar range for angiotensin II and gonadorelin. It also shows good reproducibility and has the ability of excellent automation. The secure electrical contact gives a constant spray quality, even with 100% aqueous separation buffers. The described setup has a wide applicability as is demonstrated by the analysis of larger peptides, such as insulin and cytochrome c. Detailed information is given on critical factors in the preparation of the described interfaces.

Angiotensin II↗

Capillary electrophoretic bioanalysis of therapeutically active peptides with UV and mass spectrometric detection after on-capillary preconcentration.

An earlier developed capillary electrophoresis (CE) system with an on-capillary adsorptive phase is investigated for its suitability to quantitate low concentrations of angiotensin II and gonadorelin in plasma. An off-line solid-phase extraction is used for sample preparation. The on-line preconcentration CE system allows multiple capillary volumes of sample solution to be injected, increasing the concentration sensitivity of CE with 3-4 orders of magnitude. Furthermore, possible influence of matrix salts can be ruled out by employing a rinsing step after sample application. Using short-wavelength UV detection, reproducibility and linearity in the low nanomolar range were satisfactory. The capillary could be efficiently regenerated using a programmed between-run rinsing procedure, allowing 20-30 large injections of sample extracts. Coating of the capillary improved the robustness of the method. Mass spectrometric detection via a previously reported sheathless interface increased the selectivity and sensitivity substantially. Recommendations are provided for the sample preparation process, the most critical part of the system. Further purification of the sample is required to allow the loading of larger sample volumes and to optimize the system's robustness.

Angiotensin II↗

Quantitative analysis of pharmaceutically active peptides using on-capillary analyte preconcentration transient isotachophoresis.

An on-capillary adsorptive phase in combination with capillary electrophoresis (CE), frequently referred to as preconcentration CE, for quantitative analysis of low peptide concentrations was developed. The capillary containing the on-line analyte preconcentrator can be constructed within 5 min from commercially available extraction disks. These disks contain poly(styrenedivinylbenzene) adsorbent particles incorporated in a matrix of inert Teflon, creating a mechanically stable sorbent. Therefore, no frits are needed in the capillary to hold the stationary phase in place. Several parameters, such as the required minimal elution volume, required elution strength, sample application speed or ionic strength, and the capacity were investigated and special interest was given to the quantitative properties of the method. Instead of nL injections, volumes up to a least 25 microL are possible, yielding improvements in detection limits of 3-4 orders of magnitude. The observed limit of detection for both model peptides was 20 pg, corresponding to a 20 microL injection of a 1 ng/mL solution of both model peptides. Using low-wavelength UV detection, reproducibility and linearity in the low nanogram range were satisfactory. No influence of matrix salt concentrations was observed, extending the use of CE to all kinds of samples.

Electrophoresis, Capillary↗

Derivatization trends in capillary electrophoresis.

This survey gives an overview of recent derivatization protocols, starting from 1996, in combination with capillary electrophoresis (CE). Derivatization is mainly used for enhancing the detection sensitivity of CE, especially in combination with laser-induced fluorescence. Derivatization procedures are classified in tables in pre-, on- and postcapillary arrangements and, more specifically, arranged into functional groups being derivatized. The amine and reducing ends of saccharides are reported most frequently, but examples are also given for derivatization of thiols, hydroxyl, carboxylic, and carbonyl groups, and inorganic ions. Other reasons for derivatization concern indirect chiral separations, enhancing electrospray characteristics, or incorporation of a suitable charge into the analytes. Special attention is paid to the increasing field of research using on-line precapillary derivatization with CE and microdialysis for in vivo monitoring of neurotransmitter concentrations. The on-capillary derivatization can be divided in several approaches, such as the at-inlet, zone-passing and throughout method. The postcapillary mode is represented by gap designs, and membrane reactors, but especially the combination of separation, derivatization and detection on a chip is a new emerging field of research. This review, which can be seen as a sequel to our earlier reported review covering the years 1991-1995, gives an impression of current derivatization applications and highlights new developments in this field.

Carbohydrates↗

Coupling of biological sample handling and capillary electrophoresis.

The analysis of biological samples (e.g., blood, urine, saliva, tissue homogenates) by capillary electrophoresis (CE) requires efficient sample preparation (i.e., concentration and clean-up) procedures to remove interfering solutes (endogenous/exogenous and/or low-/high-molecular-mass), (in)organic salts and particulate matter. The sample preparation modules can be coupled with CE either off-line (manual), at-line (robotic interface), on-line (coupling via a transfer line) or in-line (complete integration between sample preparation and separation system). Sample preparation systems reported in the literature are based on chromatographic, electrophoretic or membrane-based procedures. The combination of automated sample preparation and CE is especially useful if complex samples have to be analyzed and helps to improve both selectivity and sensitivity. In this review, the different modes of solid-phase (micro-) extraction will be discussed and an overview of the potential of chromatographic, electrophoretic (e.g., isotachophoresis, sample stacking) and membrane-based procedures will be given.

Electrophoresis, Capillary↗

Comparison between transient isotachophoretic capillary zone electrophoresis and reversed-phase liquid chromatography for the determination of peptides in plasma.

Low levels of peptide drugs in human plasma can be determined employing off-line solid-phase extraction, followed by capillary zone electrophoresis with UV detection. A bioanalytical procedure is presented, using gonadorelin and angiotensin II in human plasma as model compounds. The solid-phase extraction method, based on a weak cation exchange mechanism, is able to remove interfering endogenous components from the plasma sample, extract the model peptides quantitatively, and give a possibility of concentrating the sample at the same time. Transient isotachophoretic conditions were kept to increase the sample loadability by about two orders of magnitude. Up to about 70% of the capillary was filled with the reconstituted extract, whereafter the peptides were selectively concentrated during the first 15 min. Subsequently, the concentrated sample zones were separated under capillary zone electrophoresis conditions, showing the technique's high resolution. For the model cationic peptides (gonadorelin, angiotensin II) good linearity and reproducibility was observed in the 20-100 ng/mL concentration range. A more extensive washing procedure permits quantitation of gonadorelin at the 5 ng/mL level. In comparison with a liquid chromatography analysis, superior mass sensitivity and separation are obtained with the transient isotachophoretic capillary zone electrophoresis method. Moreover, in this case equivalent sensitivity is achieved when it is directly compared with a liquid chromatography method with UV detection, keeping in mind that 60 times more sample is needed for the latter method. A further gain in sensitivity can be obtained when the analysis is combined with native fluorescence detection, as is demonstrated by combining liquid chromatography separation with fluorescence detection.

Chromatography, Liquid↗

Determination of roquefortine C in blue cheese using on-line column-switching liquid chromatography.

A method is described for the determination of roquefortine C in (blue) cheese. After liquid-liquid extraction with a mixture of hydrochloric acid and methanol, and filtration, an aliquot is analysed using column-switching reversed-phase liquid chromatography. The recovery of roquefortine C in Fetta cheese is about 85%, the calibration curve is linear from 10 to 2500 ng g(-1) (r2 = 0.998), and the detection limit is about 10 ng g(-1). In different batches of Danish Blue concentrations of 1000-2000 ng g(-1) of roquefortine C are found. As regards the stability of roquefortine C its half-life in diffuse daylight is ca. 50 min, while after irradiation with ultraviolet light, it is about 10 min.

Acetates↗

Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review.

This review article presents an overview of current research on the use of capillary electrophoretic techniques for the analysis of drugs in biological matrices. The principles of capillary electrophoresis and its various separation and detection modes are briefly discussed. Sample pretreatment methods which have been used for clean-up and concentration are discussed. Finally, an extensive overview of bioanalytical applications is presented. The bioanalyses of more than 200 drugs have been summarised, including the applied sample pretreatment methods and the achieved detection limits.

Chromatography, Micellar Electrokinetic Capillary↗