Search PubMed⌕ Search

Biomedical subjects

H L Smits

Publications and source records attributed to H L Smits.

At least 19 recordsLinked to original sources

Leptospirosis: an emerging health problem in Thailand.

Leptospirosis is an emerging health problem in Thailand, with dramatic increases in reported incidence since 1996. The annual number of reported leptospirosis cases increased from 398 cases in 1996 to 14,285 cases in 2000. In 2001, 2002, and 2003, the number of reported cases decreased, but still remained high at 10,217, 6,864, and 4,958 cases, respectively. The epidemiological characteristics of leptospirosis in Thailand include a peak incidence in September and October in association with the rainy season. A vast majority of the cases (90%) were reported in the Northeast region. The case fatality rate was as high as 4.4%, having a predominant association with male farmers aged 15 to 45 years. Outpatient cases were approximately 9 times more common than admitted cases, with an apparent recent shift in the pattern of infecting serovars among reservoir animals and humans.

Adolescent↗

Rapid serological assays for leptospirosis are of limited value in southern Vietnam.

Leptospirosis, although ubiquitous and potentially lethal, is often not diagnosed. The seroprevalence of anti-Leptospira antibodies and the utility of two rapid tests for the serodiagnosis of the disease were studied in Binh Thuan, an area in southern Vietnam with favourable conditions for Leptospira. In an initial survey, blood samples from 44 patients with undifferentiated fever and 83 healthy subjects were each examined for anti- Leptospira antibodies using three tests: an ELISA; a latex card-agglutination test (Dri Dot); and a lateral-flow assay (LeptoTek Lateral Flow). In the ELISA, samples from 35% of the healthy subjects and 40% of the febrile patients were found to have titres of anti- Leptospira IgM of at least 1:80. Only one of the 13 patients checked again, in ELISA, 3 weeks later, showed the marked increase in IgM titre that is indicative of acute leptospirosis. In the initial survey, although the positive results of the lateral-flow assay, applied to whole blood and serum, showed a good agreement with those of the ELISA (kappa = 0.743), the results of the lateral-flow assay were often indeterminate. The card-agglutination test was more specific. The overall agreement between the results of the rapid tests and those of the ELISA was generally poor. When the samples classified as 'indeterminate' in the lateral-flow assay were considered positive, the maximum kappa-value for this assay applied to whole blood was only 0.512. In conclusion, it appears that high seroprevalences of anti- Leptospira IgM and low incidences of acute leptospirosis limit the diagnostic value of the rapid tests that were investigated. The lateral-flow assay is not specific enough. The card-agglutination test is possibly better but, because of the low incidence, its sensitivity could not be evaluated adequately in the present study.

Adolescent↗

Clinical utility of a dipstick assay in patients with brucellosis: correlation with the period of evolution of the disease.

To examine the clinical utility of a dipstick assay for the detection of Brucella-specific IgM antibodies, and the correlation with the evolution of the disease. Twenty-six patients who were admitted to the General Hospital of Albacete (Spain) over a 2-year period and diagnosed with brucellosis were included in the study. One hundred and twenty-five serum samples collected at the time of diagnosis and at intervals during and after treatment were tested by the Coombs test, the standard seroagglutination test (SAT), the SAT in the presence of dithiothreitol (DTT-SAT), and a dipstick assay for the detection of Brucella-specific immunoglobulin M (IgM) antibodies. The sensitivity of the dipstick assay at the moment of the diagnosis was similar to that of the SAT (62% and 73%, respectively), somewhat higher than that of the DTT-SAT (50%), and lower than that of the Coombs test (100%). Patients with a negative dipstick test at the moment of diagnosis displayed a period of evolution of the disease longer than that of the dipstick-positive patients. After the beginning of therapy, the detection rate of the dipstick assay decreased faster than those of the SAT, the DTT-SAT, and the Coombs test. Thirty days after the start of therapy, the detection rate of the dipstick assay had decreased to 7%, whereas that of the SAT and DTT-SAT was 46%, and that of the Coombs test was still 92%. The dipstick assay could be used as a rapid diagnostic test for patients in the early stages of illness. Patients with a long period of illness will probably have a negative dipstick test, and could be diagnosed with the aid of the Coombs test and classical clinical findings.

Agglutination Tests↗

Simple and fast lateral flow test for classification of leprosy patients and identification of contacts with high risk of developing leprosy.

The interruption of leprosy transmission is one of the main challenges for leprosy control programs since no consistent evidence exists that transmission has been reduced after the introduction of multidrug therapy. Sources of infection are primarily people with high loads of bacteria with or without clinical signs of leprosy. The availability of a simple test system for the detection of antibodies to phenolic glycolipid-I (PGL-I) of Mycobacterium leprae to identify these individuals may be important in the prevention of transmission. We have developed a lateral flow assay, the ML Flow test, for the detection of antibodies to PGL-I which takes only 10 min to perform. An agreement of 91% was observed between enzyme-linked immunosorbent assay and our test; the agreement beyond chance (kappa value) was 0.77. We evaluated the use of whole blood by comparing 539 blood and serum samples from an area of high endemicity. The observed agreement was 85.9% (kappa = 0.70). Storage of the lateral flow test and the running buffer at 28 degrees C for up to 1 year did not influence the results of the assay. The sensitivity of the ML Flow test in correctly classifying MB patients was 97.4%. The specificity of the ML Flow test, based on the results of the control group, was 90.2%. The ML Flow test is a fast and easy-to-perform method for the detection of immunoglobulin M antibodies to PGL-I of M. leprae. It does not require any special equipment, and the highly stable reagents make the test robust and suitable for use in tropical countries.

Antibodies, Bacterial↗

Latex based, rapid and easy assay for human leptospirosis in a single test format.

Leptospirosis is an often severe disease which requires prompt treatment. Laboratory testing is required to reach a valid diagnosis. An agglutination assay for the detection of Leptospira-specific antibodies consisting of individually wrapped agglutination cards containing a stable, dried detection reagent is evaluated. The assay is simply performed by suspending the dried reagent with a drop of serum. The result is obtained within 30 s. The sensitivity of the assay varied with the stage of the disease and was 72.3% for samples collected during the first 10 days of the illness and 88.2% for samples collected at a later stage. The specificity was 93.9% and 89.8%, respectively. These characteristics make the test ideal for use in areas where the disease is common and where laboratory support is not routinely available.

Antibodies, Bacterial↗

Evaluation of three methods to measure anti-Brucella IgM antibodies and interference of IgA in the interpretation of mercaptan-based tests.

The results of a dipstick assay for the detection of immunoglobulin M (IgM) to Brucella smooth lipopolysaccharide (S-LPS) correlated with those of an enzyme-linked immunosorbent assay (ELISA) for IgM and of the serum agglutination test (SAT) performed with and without dithiothreitol. Two sera which were dithiothreitol-sensitive and were dipstick negative were shown to contain specific IgA. The dipstick assay is recommended as a simple method for detecting specific IgM antibodies in acute-phase brucellosis patients.

Agglutination Tests↗

Lateral-flow assay for rapid serodiagnosis of human leptospirosis.

An assay device for the rapid detection of Leptospira-specific immunoglobulin M (IgM) antibodies in human sera is presented. The sensitivity (85.8%) and specificity (93.6%) of the assay compared well (91.9% agreement) with those of an IgM enzyme-linked immunosorbent assay routinely used in the serodiagnosis of leptospirosis. The sensitivity of the assay varied with the stage of the disease. The assay uses stabilized components and is simply performed by the addition of serum and sample fluid to the sample well of the assay device. The assay is read after 10 min, and a positive result is obtained when staining of the test line is observed.

Antibodies, Bacterial↗

International multi-centre evaluation of a dipstick assay for human leptospirosis.

A dipstick assay for the detection of Leptospira-specific immunoglobulin M (IgM) antibodies in human sera was evaluated in 27 laboratories in 23 countries. 873 serum samples from 711 patients including 329 laboratory-confirmed leptospirosis case patients, 239 noncase patients and 69 patients with viral infections causing heamorrhagic fever were tested. Relative to the results of the reference leptospirosis test, the sensitivity of the dipstick assay was 84.5% for serum samples collected during the first 10 days of the disease and 92.1% for serum samples collected 10-30 days after the onset of disease. The specificity was 87.5% and 94.4%, respectively. Similar to viral haemorrhagic fevers, leptospirosis may cause bleeding. A small number of serum samples from patients with haemorrhagic viral infections gave a weak (1 +) stain. All other samples were negative. In conclusion, the dipstick assay is sensitive and specific and reacts well with serum samples from patients infected with a range of leptospiral strains. It is also easy to use and does not require special equipment or refrigeration. Therefore the assay is ideal for use in developing countries and rural settings.

Antibodies, Bacterial↗

Simple latex agglutination assay for rapid serodiagnosis of human leptospirosis.

A newly developed latex agglutination assay for the detection of genus-specific Leptospira antibodies in human sera was evaluated. The assay is performed by mixing, on an agglutination card, serum with equal volumes of stabilized antigen-coated, dyed test and control latex beads and is read within 2 min. The latex agglutination test was evaluated with groups of serum samples from patients with leptospirosis and control patients from Hawaii, the Seychelles, Thailand, and The Netherlands. The mean overall sensitivity was 82.3%, and the mean overall specificity was 94.6%. The assay is easy to perform and does not require special skills or equipment. The reagents have a long shelf life, even at tropical temperatures. Together, these factors make the assay suitable for use even at the peripheral level of a health care system as a rapid screening test for leptospirosis.

Antibodies, Bacterial↗

Introduction of a rapid dipstick assay for the detection of Leptospira-specific immunoglobulin m antibodies in the laboratory diagnosis of leptospirosis in a hospital in Makassar, Indonesia.

An easy, rapid and robust dipstick assay for detection of leptospira-specific immunoglobulin M (IgM) antibodies was evaluated on 403 patients admitted for hospitalization because of fever. The clinical symptoms and signs of 35 patients were consistent with leptospirosis. The final diagnosis for the remaining patients was as follows: 136 with typhoid fever, 82 with hepatitis, 74 with malaria, 48 with infections of the respiratory tract, and 20 with fever of unknown origin. The clinical diagnosis of leptospirosis was confirmed for 24 (68.6%) patients by the combined results of the microscopic agglutination test (MAT), the reference test for leptospirosis, and of IgM ELISA, a standard laboratory test for the serodiagnosis of leptospirosis. In addition, serum specimens from 8 (2.2%) patients with a final clinical diagnosis other than leptospirosis were found to be positive in MAT and/or IgM ELISA. Compared with the results of MAT and IgM ELISA a sensitivity of 91.6% and specificity of 93.6% was calculated for the dipstick assay. Most of the serum samples from the laboratory confirmed patients gave a moderate to strong staining intensity of the antigen band of the dipstick and were easy to read. The results demonstrate that the dipstick assay is convenient to use and allows the rapid and accurate confirmation of patients with clinical suspicion of leptospirosis in areas where the disease is endemic.

Antibodies, Bacterial↗

Field evaluation of a one-step dipstick assay for the diagnosis of human leptospirosis in the Seychelles.

OBJECTIVE AND METHOD: To compare the response of a dipstick assay (DSA) detecting Leptospira-specific immunoglobulin M (IgM) antibodies with that of an enzyme-linked immunosorbent assay (ELISA), an indirect haemagglutination assay (IHA), the microagglutination test (MAT) and a polymerase chain reaction assay (PCR) in patients with leptospirosis confirmed by MAT alone or by MAT and/or PCR (MAT/PCR). RESULT: In 75 patients with acute leptospirosis diagnosed by MAT (respectively, 90 patients diagnosed by MAT/PCR), the response in paired early and convalescent sera was positive in 78.9% (67.9%) by DSA, 76.0% (67.8%) by ELISA, 58.7% (55.6%) by IHA, 44.0% (53.3%) by PCR, and 100% (90.0%) by MAT. In early serum only, the response in patients diagnosed by MAT (respectively by MAT/PCR) was positive in 36.0% (38.9%) by DSA, 36.0% (37.8%) by ELISA, 14.7% (18.9%) by IHA, 39.2% (48.3%) by PCR, and 53.3% (58.9%) by MAT titre > or =1:100. DSA detected the main serogroups implicated in human leptospirosis in Seychelles and demonstrated sensitivity comparable to ELISA. In 124 single sera from control subjects without overt disease, the response was positive in 4.8% by DSA, 3.2% by ELISA, 3.2% by IHA, 13.8% by PCR, 37.9% by MAT titre > or =1:100, and 2.4% by MAT titre > or =1:800, giving evidence of the frequency of both past and current subclinical infection in Seychelles and that DSA was less sensitive than MAT to detect moderate levels of leptospiral antibodies. CONCLUSION: DSA is a simple and reproducible assay well adapted to field conditions and could usefully contribute to the evaluation of leptospirosis in areas devoid of serological laboratory facilities.

Acute Disease↗

Development and evaluation of a rapid dipstick assay for serodiagnosis of acute human brucellosis.

A dipstick assay for the detection of brucella-specific immunoglobulin M antibodies was evaluated with 707 sera from 247 laboratory-confirmed brucellosis patients and 342 control sera from brucellosis-free individuals. These sera were collected from six different countries. The assay was found to be highly sensitive and specific. In addition, the test is easy to use and does not require specialized training or equipment, and the components are stable without a requirement for refrigeration. All of these factors make the test ideal for developing countries and rural settings.

Acute Disease↗

International multicenter evaluation of the clinical utility of a dipstick assay for detection of Leptospira-specific immunoglobulin M antibodies in human serum specimens.

We performed a multicenter evaluation of a robust and easily performed dipstick assay for the serodiagnosis of human leptospirosis. The assay is aimed at the detection of Leptospira-specific immunoglobulin M (IgM) antibodies. The study involved 2,665 serum samples collected from 2,057 patients with suspected leptospirosis in 12 countries on five continents with different levels of endemicity and different surveillance systems. The patients were grouped as laboratory-confirmed leptospirosis case patients and noncase patients based on the results of culturing and the microscopic agglutination test. Paired samples from 27.7% of the subjects were tested. Of the 485 case patients, 87.4% had a positive dipstick result for one or more samples. Of the 1,513 noncase patients, only 7.2% had a positive result. Whereas most (88.4%) of the positive samples from the case patients showed moderate to strong (2+ to 4+) staining in the dipstick assay, most (68.1%) of the positive samples from the noncase patients showed weak (1+) staining. The sensitivity of the dipstick assay increased from 60.1% for acute-phase serum samples to 87.4% for convalescent-phase samples. The specificities for these two groups of samples were 94.1 and 92.7%, respectively. The dipstick assay detected a broad variety of serogroups. The results of the dipstick assay were concordant (observed agreement, 93.2%; kappa value, 0.76) with the results of an enzyme-linked immunosorbent assay for the detection of specific IgM antibodies, a test which is often used in the laboratory diagnosis of current or recent leptospirosis. This study demonstrated that this easily performed dipstick assay is a valuable and useful test for the quick screening for leptospirosis; has a wide applicability in different countries with different degrees of endemicity; can be used at all levels of the health care system, including the field; and will be useful for detecting and monitoring outbreaks of leptospirosis.

Agglutination Tests↗

Increase of leptospirosis in dengue-negative patients after a hurricane in Puerto Rico in 1996 [correction of 1966].

Leptospirosis has rarely been reported in Puerto Rico, although in the period from 1948 to 1952, 208 cases of leptospirosis and an island-wide seroprevalence of antibody to Leptospira of 14% were documented. In Puerto Rico in October 1996, following rainfall and a period of flooding generated by Hurricane Hortense, serum specimens of 4 patients with suspected dengue fever that were negative for dengue tested positive for Leptospira-specific IgM antibodies in a dipstick assay. Subsequently, we used an island-wide dengue laboratory-based surveillance system to determine the increase in leptospirosis after hurricane-generated floods. All anti-dengue IgM-negative patients (n = 142) with disease onset from August 8 to October 6, 1996 from prehurricane and posthurricane groups were investigated for leptospirosis. Laboratory-confirmed leptospirosis cases were defined as microscopic agglutination test titers > or = 1 :400 to 1 or more serovars, or positive immunohistochemistry in autopsy tissues. Four (6%) of 72 prehurricane and 17 (24%) of 70 posthurricane patients had laboratory-confirmed cases of leptospirosis (relative risk [RR] = 4.4, 95% confidence interval [CI] = 1.6-12.4). The mean age of case-patients was 34 years (range = 13-64). Eighteen (86%) of 21 confirmed case-patients were males, including one patient who died (31 years old). Patients were located in 18 (38%) of 48 municipalities that submitted serum samples. Clinical features significantly associated with leptospirosis were eye pain (RR = 1.5, 95% CI = 1.3-1.9), joint pain (RR = 1.4, 95% CI = 1.1-1.6), diarrhea (RR = 1.7, 95% CI = 1.2-2.5), and jaundice (RR = 3.3, 95% CI = 1.5-7.2). This study demonstrates the utility of a dengue laboratory-based surveillance system for the detection of an increase of leptospirosis, which most likely would have gone unrecognized. Leptospirosis is treatable with antibacterial agents; knowledge of this diagnosis may significantly reduce morbidity and mortality.

Adolescent↗

Risk factors for HPV detection in archival Pap smears. A population-based study from Greenland and Denmark.

The most important risk factor for cervical cancer is genital infection with certain types of human papillomavirus (HPV). The presence of HPV was studied in archival smears from a random sample of women living in Greenland (GW) and Denmark (DW) having, respectively, a high risk and an intermediate risk for cervical cancer. Risk factors were also examined of the original 126 Danish and 129 Greenlandic archived smears collected during October and November 1988. 125 were located from each country including all abnormal smears. HPV DNA was isolated from the smears and detected by means of a consensus polymerase chain reaction (PCR) detecting a broad spectrum of genital HPV types. HPV was detected in all the abnormal smears and in 22 and 33% respectively of the cytological normal smears from DW and GW. Risk of HPV was significantly higher in smears from women who started sexual life relatively recently (respectively, < or = 4 and < or = 6 years ago in DW and GW) compared with > or = 10 years ago (adjusted prevalence-OR: 9.3; 95% CI: 2.2-39.2 in DW and 5.9; 95% CI: 1.4-25.3 in GW). Among other important risk factors were age in both areas, lifetime number of sex partners and current smoking in DW and ever and gonorrhoea in GW. This study confirms the usefulness of the method as all abnormal smears were positive and, furthermore, the predictors for HPV presence in the normal smears corroborate with those found in recent studies of HPV in fresh cervical swabs. Thus, this method can be useful for large-scale epidemiological studies of HPV DNA in already sampled material.

Adult↗

A simple dipstick assay for the detection of antibodies to phenolic glycolipid-I of Mycobacterium leprae.

Among the many reported applications of the detection of antibodies to phenolic glycolipid-I (PGL-I) of Mycobacterium leprae, in particular, the use of seroprevalence as an indicator of the magnitude of the leprosy problem may turn out to be very useful in leprosy control programs. An operational function of serology within the leprosy control services requires a simple test system. We have developed a simple dipstick assay for the detection of antibodies to PGL-I and compared its performance with that of an ELISA. A high degree of agreement (97.2%) was observed between the ELISA and the dipstick assay when tested on 435 sera; the agreement beyond chance (Kappa value) was 0.92. No significant difference was found between the dipstick assay and the ELISA when seropositivity rates obtained in groups of leprosy patients, household contacts, and controls were compared. The interpretation of the dipstick results as positive or negative was unequivocal, as illustrated by the high agreement between different persons reading the test (Kappa values > 0.88). Storage of the only reagents required, the dipsticks and the stabilized detection reagent, up to three weeks under tropical conditions of high temperatures, high humidity, and exposure to light, did not influence the results of the assay. The dipstick assay described here is an easy-to-perform method for the detection of IgM antibodies to PGL-I of M. leprae; it does not require any special equipment and the highly stable reagents make the test robust and suitable for use in tropical countries. An internal control validates the performance of the assay. This dipstick assay may be the method of choice for epidemiologic mapping of leprosy.

Antibodies, Bacterial↗

Managing the interface between medical schools, hospitals, and clinical research.

OBJECTIVE: To review how academic health centers are coping with the changing environment of health care delivery with special emphasis on the impact of the changing health care system on clinical research. DESIGN: In response to Health and Human Services Secretary Donna Shalala's 1995 mandated review of the National Institutes of Health (NIH) Warren Grant Magnuson Clinical Center, an NIH review team visited 30 health facilities and government-owned organizations throughout the country. The review team determined what strategies are used by academic health centers to survive and thrive in the changing health care marketplace. The findings have implications for the NIH Clinical Center as well as academic health centers. CONCLUSIONS: Management strategies in successful academic health centers include streamlined governance structures whereby small groups of highly empowered group leaders allow institutions to move quickly and decisively; an active strategic planning process; close integration of hospital and medical school management; heavy investment in information systems; and new structures for patient care delivery. Successful centers are initiating discussions with third-party payers and are implementing new initiatives, such as establishing their own managed care organizations, purchasing physician practices, or owning hospitals. Other approaches include establishing revenue-generating centers for clinical research and new relations with industry. Attention to the infrastructure required to support the training and conduct of clinical research is essential for the future vitality of medical schools.

Academic Medical Centers↗

Generation of a human melanocyte cell line by introduction of HPV16 E6 and E7 genes.

Availability of a standard human melanocyte cell line with unlimited growth potential and otherwise normal melanocytic properties will greatly facilitate research in melanocyte biology and in vitro studies on the etiology of pigmentary disorders and melanoma. Using a retroviral vector, E6 and E7 open reading frames of human papilloma virus type 16 (HPV 16) have been introduced into cultured normal human melanocytes. Cells selected by increased resistance to geneticin conveyed by the vector and expressing E6E7 mRNA have been cloned to ensure genetic homogeneity. Since their establishment as primary cells, cloned PIG1 cells have undergone more than twice the amount of population doublings of senescent parental cells. Moreover, in passage numbers when parental cells had become senescent, proliferation of clonal cells was retained at levels exceeding those of normal human melanocytes in third passage by 100%. Further characterization has revealed that the cells remain dependent on tetradecanoyl phorbol 13-acetate (TPA) for growth and do not proliferate in soft agar nor form tumors in nude mice. The antigenic profile of the cells was slightly altered as compared to parental cells, but was incomparable to that of M14 melanoma cells. Importantly, PIG1 cells contain more melanin pigment than parental cells.

Animals↗