Search PubMed⌕ Search

Biomedical subjects

H K Gold

Publications and source records attributed to H K Gold.

At least 73 records · Page 4Linked to original sources

Detection of coronary artery reperfusion with creatine kinase-MB determinations during thrombolytic therapy: correlation with acute angiography.

Increases in plasma creatine kinase-MB (MB CK) were correlated with the onset of coronary artery reperfusion determined angiographically in 32 patients with acute myocardial infarction who were treated with recombinant human tissue-type plasminogen activator (rt-PA). Reperfusion occurred in 14 (70%) of 20 patients with left anterior descending coronary artery occlusion and in 8 (73%) of 11 patients with right coronary artery occlusion. One patient had persistent left circumflex coronary artery occlusion. Plasma MB CK levels (radioimmunometric assay) did not increase significantly in patients with persistent occlusion, but increased by a mean (+/- SEM) of 8 +/- 1 and 6 +/- 1 times over pretreatment levels at the end of the infusion in patients with a reperfused left anterior descending and right coronary artery, respectively. When a greater than or equal to 2.5-fold increase in MB CK levels at the end of the rt-PA infusion was taken as evidence of reperfusion of the left anterior descending coronary artery, 13 (93%) of 14 patients with reperfusion and 5 (83%) of 6 with persistent occlusion were correctly identified. When a greater than or equal to 2.2-fold increase in MB CK levels was used to identify right coronary artery reperfusion, seven (89%) of eight patients with persistent occlusion were correctly identified. The sensitivity and specificity of these indexes, derived from and applied to the same patient group, were 91 and 89%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Angiography↗

Continuous monitoring of left ventricular function by an ambulatory radionuclide detector in patients with coronary artery disease.

Global left ventricular function and a modified V5 electrocardiographic (ECG) lead were continuously monitored by a radionuclide recorder in 12 normal subjects and 39 patients with coronary artery disease while the subjects were performing various daily activities. The ambulatory studies revealed that walking on a level surface caused 11 of 12 normal subjects and 18 of 32 patients to increase their left ventricular ejection fraction by greater than 6% units. A transient decrease in left ventricular ejection fraction (6 to 18%) lasting greater than or equal to 1 min was observed on 36 occasions in 16 patients with coronary artery disease; 12 episodes were accompanied by chest pain or shortness of breath and 24 were asymptomatic. Electrocardiographic ST segment depression suggestive of ischemia was recorded in 6 of the 12 symptomatic and 5 of the 24 asymptomatic episodes. In 10 of the 12 symptomatic episodes, left ventricular ejection fraction began to decrease 30 to 90 s before the onset of symptoms. These studies suggest that continuous monitoring of both left ventricular function and the ECG may permit stratification of episodes of ST depression suggesting ischemia by the degree of left ventricular dysfunction they produce.

Activities of Daily Living↗

Effect of hyaluronidase on mortality and morbidity in patients with early peaking of plasma creatine kinase MB and non-transmural ischaemia. Multicentre investigation for the limitation of infarct size (MILIS).

A multicentred, randomised, blind study was started in 1978 to compare propranolol or hyaluronidase with placebo in patients with acute myocardial infarction admitted within 18 hours of onset of symptoms. Patients were randomised to group A and received hyaluronidase, propranolol, or placebo, or, if propranolol was contraindicated, to group B and received hyaluronidase or placebo. Hyaluronidase (500 U/kg given every six hours for 48 hours) had no effect on mortality or infarct size in the overall population. Because spontaneous reperfusion was more common in patients with early peaking of plasma creatine kinase MB or non-transmural electrocardiographic changes or both, the results were reanalysed for two subgroups: those in whom plasma creatine kinase peaked less than 15 hours after the onset of symptoms (early peak, n = 184) and those with a peak greater than 15 h after the onset of symptoms (late peak, n = 546). The distribution of time to peak activity of creatine kinase MB was similar in the hyaluronidase and placebo groups. In the early peak patients who were given hyaluronidase (groups A and B) total mortality and cardiac-specific four year mortality were significantly lower. This was most pronounced in group B in which the total mortality was 45% and cardiovascular mortality was 47% less than in the placebo group. Similarly, mortality from cardiovascular disease in patients (groups A and B) with nontransmural ischaemia (ST-T changes) given hyaluronidase was significantly lower, with group B showing a 50% reduction. In the subsets of patients with late peaking of creatine kinase MB or those presenting with transmural electrocardiographic changes there was no difference in total mortality or deaths from cardiac disease between those given hyaluronidase and those given placebo. Hyaluronidase was associated with improved survival in patients with early peaking of plasma creatine kinase MB, suggesting the possibility of salvage of myocardium in patients who have early spontaneous reperfusion and possibly after therapeutic reperfusion.

Clinical Trials as Topic↗

Thrombolytic therapy.

Thrombolytic agents are plasminogen activators that convert plasminogen, the inactive proenzyme of the fibrinolytic system in blood, to the proteolytic enzyme plasmin. Plasmin in turn dissolves the fibrin of a blood clot, but may also degrade normal components of the hemostatic system and predispose to bleeding. The first-generation thrombolytic agents, streptokinase and urokinase, are only moderately efficacious, and their administration is associated with extensive systemic fibrinogen breakdown. In three major clinical trials in patients with acute myocardial infarction, early intravenous streptokinase significantly reduced in-hospital mortality. Tissue-type plasminogen activator (t-PA) is a more effective and fibrin-specific coronary arterial thrombolytic agent than streptokinase, but its impact on mortality remains to be established. Single-chain urokinase-type plasminogen activator (scu-PA, pro-urokinase) is more fibrin specific than urokinase but has only reached the stage of early clinical investigation. The acylated plasminogen streptokinase activator complex (Apsac) has a profile of thrombolytic efficacy and fibrin specificity that is probably very similar to that of streptokinase, but it can be administered as a single bolus injection. New trends toward further improved efficacy and fibrin specificity of thrombolytic therapy include the use of combinations of synergistic thrombolytic agents, mutants of t-PA or scu-PA, chimeric t-PA/scu-PA molecules, or antibody-targeted thrombolytic agents.

Clinical Trials as Topic↗

Rapid and sustained coronary artery recanalization with combined bolus injection of recombinant tissue-type plasminogen activator and monoclonal antiplatelet GPIIb/IIIa antibody in a canine preparation.

The effects of bolus injections of recombinant single-chain tissue-type plasminogen activator (rt-PA) and of F(ab')2 fragments of a murine monoclonal antibody (7E3) against the human platelet GPIIb/IIIa receptor [7E3-F(ab')2] on coronary arterial thrombolysis and reocclusion was studied in a canine preparation of coronary artery thrombosis superimposed on high-grade stenosis. Bolus intravenous injections of rt-PA at a dose of 0.45 mg/kg, repeated at 15 min intervals until reperfusion occurred (maximum of four injections) caused reperfusion in five of seven dogs within 100 min (33 +/- 15 min, mean +/- SD). Reperfusion was rapidly followed (generally within 10 min) by reocclusion and then by periods of cyclical reflow and reocclusion. A single intravenous injection of 7E3-F(ab')2 alone at 0.8 mg/kg caused reperfusion within 100 min in two of six dogs (19 and 37 min) without subsequent reocclusion. Single bolus injections of different amounts (0.1 to 0.8 mg/kg) of 7E3-F(ab')2 were then combined with bolus injections of 0.45 mg/kg of rt-PA. Stable reperfusion without reocclusion was accomplished with 0.8 or 0.6 mg/kg 7E3-F(ab')2 and a single injection of 0.45 mg/kg rt-PA within 6 +/- 3 min (n = 6, p less than .01) and 8 +/- 5 min (n = 5, p less than .02), respectively. None of these animals suffered reocclusion of the coronary artery. Lower doses (0.1 to 0.2 mg/kg) of 7E3-F(ab')2 did not significantly shorten the time to reperfusion and did not prevent reocclusion.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Prevention of coronary artery reocclusion and reduction in late coronary artery stenosis after thrombolytic therapy in patients with acute myocardial infarction. A randomized study of maintenance infusion of recombinant human tissue-type plasminogen activator.

Sixty-eight patients with acute "transmural" myocardial infarction presenting within 6 hours (range, 1.3-5.8 hours) of onset of chest pain were given intravenous recombinant tissue-type plasminogen activator (rt-PA) at a dosage of 1 mg/kg during 90 minutes. Coronary angiography at 90 minutes revealed a patent infarct-related coronary artery in 52 patients (76%). These patients were randomized either to treatment by continuous infusion of heparin alone (27 patients) or to treatment by heparin and a maintenance infusion of rt-PA at a dosage of 0.8 mg/kg during 4 hours (25 patients). Coronary angiography was repeated 60 minutes after the start of the maintenance infusion and again after 8-14 days. Acute symptomatic reocclusion of the infarct-related artery occurred during the 1-hour observation period in five (19%) patients treated with heparin alone but in none of the patients treated with rt-PA (p = 0.05). The measured residual stenosis of the patent infarct-related coronary artery was similar in the heparin-treated and the rt-PA-treated groups at 90 minutes infusion: 66 +/- 14% versus 68 +/- 13% diameter stenosis, respectively (mean +/- SD) and 1.1 +/- 1.1 mm2 versus 0.82 +/- 0.7 mm2 area (p = 0.35). At 8-14 days after infusion, residual stenosis was unchanged in the heparin-treated group, but it improved to 55 +/- 17% (p = 0.001) and 1.6 +/- 1.2 mm2 (p = 0.003) in the rt-PA-treated group. At 90 minutes of infusion, residual intraluminal thrombus was observed in 29 of the 52 patients (56%) with a comparably measured distribution in the two groups (p = 0.43). At 150 minutes, however, the extent of intraluminal thrombus was significantly reduced in the rt-PA-treated group as compared with the heparin-treated group (p = 0.03). In-hospital ischemic events (symptomatic reocclusion, unstable angina, or cardiovascular death) occurred in 12 patients of the heparin-treated group but only in three patients of the rt-PA-treated group (p = 0.03). Fibrinogen levels decreased to 65 +/- 21% of baseline at 90 minutes of rt-PA infusion. During the rt-PA maintenance infusion, fibrinogen fell slightly from 63 +/- 26 to 57 +/- 28% (p = 0.18). This study shows that after successful reperfusion with 1 mg/kg rt-PA during 90 minutes, a maintenance infusion of 0.8 mg/kg rt-PA during 4 hours prevents acute symptomatic coronary artery reocclusion, and it reduces the frequency of ischemic events and the severity of residual coronary artery stenosis at hospital discharge.

Aged↗

Monoclonal antibody against the platelet glycoprotein (GP) IIb/IIIa receptor prevents coronary artery reocclusion after reperfusion with recombinant tissue-type plasminogen activator in dogs.

Localized thrombosis was produced in the left anterior descending (LAD) coronary artery of open chest dogs by constricting a segment so as to produce greater than 90% stenosis (reducing blood flow to 40 +/- 10% of baseline), and placing a thrombus in the segment immediately proximal to the stenosis by inducing endothelial cell injury and instilling a mixture of blood and thrombin. Intravenous infusion of recombinant tissue-type plasminogen activator (rt-PA) at a rate of 15-30 micrograms/kg per min for 30 or 60 min in eight dogs induced coronary artery reperfusion within 23 +/- 7 min (mean +/- SD), but reocclusion occurred despite heparin anticoagulation in all but one of these dogs within 7 +/- 5 min. Intravenous injection of 0.8 mg/kg of the F(ab')2 fragment of a monoclonal antibody (7E3) directed against the platelet GPIIb/IIIa receptor, prevented reocclusion in 10/10 dogs during an observation period of 2 h (P less than 0.001 vs. rt-PA alone). The antibody abolished ADP-induced platelet aggregation and markedly prolonged the bleeding time. Intravenous aspirin or dipyridamole prevented reocclusion for 1 h or more in only 2/7 and 1/6 dogs, respectively. We conclude that the monoclonal antibody is very effective in preventing reocclusion after successful thrombolysis of occluded coronary arteries with rt-PA.

Animals↗

Evolutionary changes in left and right ventricular function in acute myocardial infarction.

To determine the evolutionary changes in right and left ventricular function in acute myocardial infarction, 3 serial gated blood pool scans were performed in 76 patients within 24 hours (24 H), at 10 days (10 D) and 3 months (3 M) following the onset of myocardial infarction. The patients were divided into 3 groups: ANT (anterior MI), INF (inferior MI without right ventricular dysfunction) and RVF (inferior MI with right ventricular dysfunction). LVEF in ANT was significantly lower than that of INF and RVF at 24 H, 10 D and 3 M. The ratio of right ventricular volume to LV volume (RVV/LVV) was compared among 3 groups. The mean values of RVV/LVV in RVF were 1.3 through 24 H and 3 M and they were significantly higher than the other two groups. The RVV/LVV in ANT and INF were around 1.0. LVEDVI in RVF was rather smaller than that of ANT and INF. LVESVI in ANT at 24 H was significantly larger than that of INF and RVF and the mean value of LVESVI in ANT were around 60 ml/M2 from 24 H to 3 M. LVEF in ANT, RVF and INF did not increase significantly during peak exercise at 3 M. However, quantitative regional wall motion analysis revealed that regional wall motion of R2 (posterolateral wall motion) in ANT and R5 (septal wall motion) in INF decreased significantly during peak exercise. These impairments in regional wall motion might be due to the exacerbation of ischemia of non-infarcted area.

Adult↗

Comparative properties of two clinical preparations of recombinant human tissue-type plasminogen activator in patients with acute myocardial infarction.

The biologic properties of two clinical preparations of recombinant human tissue-type plasminogen activator were studied in 52 patients with acute myocardial infarction. The first preparation (G11021) has been used in all clinical trials reported to date, whereas the second preparation (G11035) is now produced for future clinical use. When both preparations were infused intravenously for 90 minutes at rates of 4 to 11 micrograms/kg per min, plateau levels of the drug in plasma ranged from 0.52 +/- 0.15 to 1.8 +/- 0.4 micrograms/ml and were linearly correlated with the infusion rate. However, G11035 yielded plasma levels that were approximately 35% lower than those obtained with G11021 (p less than 0.025). The postinfusion disappearance rate of the drug from plasma could be described by a two compartment disposition model with the following pharmacokinetic variables. For G11021, an alpha half-life of 4.1 to 6.3 minutes, a beta half-life of 41 to 50 minutes, a central compartment volume of 3.5 to 5.4 liters, a total distribution volume of 28 to 44 liters and a plasma clearance of 450 to 640 ml/min. For G11035 these variables were 3.6 to 4.6 minutes, 39 to 53 minutes, 3.8 to 6.6 liters, 27 to 40 liters and 520 to 1,000 ml/min, respectively, indicating that G11035 is cleared more rapidly from the circulation. G11021 at 4 micrograms/kg per min and G11035 at 7 micrograms/kg per min did not effectively produce thrombolysis. A coronary reperfusion rate of 81% (13 of 16 patients) was obtained with 5.3 micrograms/kg per min of G11021 and a rate of 86% (6 of 7 patients) was obtained with 9.4 micrograms/kg per min of G11035.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Thrombolytic therapy for unstable angina pectoris: rationale and results.

The coronary lesion in unstable angina consists of disrupted atherosclerotic plaque with nonocclusive intraluminal thrombus, which frequently persists despite heparin anticoagulation. A 12 hour infusion of recombinant tissue-type plasminogen activator combined with heparin effectively lyses the thrombus and stabilizes the clinical syndrome but is associated with a high incidence of bleeding. Therapeutic schemes of thrombolytic therapy associated with a lower bleeding frequency may be useful for the treatment of unstable angina.

Angina Pectoris↗

Left and right ventricular function after streptokinase reperfusion: assessment by gated blood pool scans.

Twenty-three patients with acute anterior or inferior myocardial infarction (AMI, IMI) were investigated by gated blood pool scans at a mean 4.9 h after reperfusion and 10 days later. Eighteen (78%) successful reperfusion cases were divided into two groups; reperfusion in less than 4 h (Rp less than 4 h, n = 9) and reperfusion in more than 4 h (Rp greater than 4 h, n = 9) from the onset of chest pain. As control group, gated blood pool scans were also performed in the early hours following infarction in an additional 42 patients who received conventional treatments. Rp less than 4 h demonstrated significant improvement of mean LVEF in AMI (from 39.5 +/- 3.3 to 50.3 +/- 3.1%, p less than 0.01) and IMI (from 54.6 +/- 4.3 to 60.4 +/- 5.8%, p less than 0.01). Improvement of initially abnormal segments was noticed in 68% of AMI and 65% of IMI by quantitative wall motion analysis, while Rp greater than 4 h showed only slight improvement of LVEF and regional wall motion compared to Rp less than 4 h. On the other hand, the control group showed no significant change in left ventricular performance and regional wall motion. In patients with AMI, RVEF remained within normal range. In IMI, whether reperfused or not, the RVEF showed moderate improvement. In conclusion, these studies indicated that the time of reperfusion and location of infarction may influence functional recovery after streptokinase reperfusion.

Adult↗

A randomized, blinded, placebo-controlled trial of recombinant human tissue-type plasminogen activator in patients with unstable angina pectoris.

Twenty-four patients with unstable angina pectoris, defined as chest pain at rest with transient ST segment deviation of at least 1 mm, were randomly assigned to blinded treatment with either placebo or intravenous recombinant human tissue-type plasminogen activator (rt-PA). Before randomization, all patients were treated with oral beta-blockers, calcium antagonists, nitrates, and continuous intravenous heparin for a monitoring period of 12 to 28 hr. After this monitoring period the 24 patients were randomly assigned to receive either placebo or 1.75 mg/kg intravenous rt-PA given over 12 hr at a rate of 0.75 mg/kg over 1 hr, 0.5 mg/kg over 4 hr, and 0.5 mg/kg over 7 hr. One patient, assigned to receive placebo, developed acute myocardial infarction after randomization but before receiving the study drug. Ischemic events were recorded during a hospital follow-up period of at least 4 days unless a further intervention was indicated or the coronary angiogram was normal. The follow-up period was 7 +/- 5 days (mean +/- SD) after the placebo infusion and 8 +/- 4 days after the infusion of rt-PA. Unstable angina pectoris persisted after the completion of the infusion in six of 11 patients receiving placebo and only one of 12 patients receiving rt-PA (p less than .03). Coronary angiography, performed 38 +/- 19 hr after the infusion, demonstrated subocclusive thrombus in eight of 11 patients receiving placebo but in none of 11 patients treated with rt-PA (p less than .002). One patient on rt-PA refused coronary angiography.(ABSTRACT TRUNCATED AT 250 WORDS)

Angina Pectoris↗

Indium 111-monoclonal antimyosin antibody imaging in the diagnosis of acute myocarditis.

A definitive diagnosis of myocarditis requires right ventricular biopsy. Despite its specificity, however, right ventricular biopsy may lack sensitivity due to the focal nature of the disease. Because indium 111-monoclonal antimyosin antibody imaging can be used to detect myocardial necrosis, this procedure was performed on 28 patients clinically suspected of having myocarditis, 25 of whom had left ventricular ejection fractions of less than 45%, and the results were compared with those of right ventricular biopsy performed within 48 hr of the scan. Antimyosin scans were positive in nine patients who had evidence of myocarditis on right ventricular biopsy, and negative in 11 who had no evidence of myocarditis by biopsy. The remaining eight had positive antimyosin scans but showed no evidence of myocarditis on right ventricular biopsy. On the basis of a right ventricular biopsy standard, the sensitivity of this method was 100%, the specificity 58%. We conclude that antimyosin antibody imaging is a reliable screening method for the evaluation of patients suspected of having myocarditis, and that a positive antimyosin scan indicates the need for right ventricular biopsy to establish the histologic diagnosis.

Acute Disease↗

Myocardial damage delineated by indium-111 antimyosin Fab and technetium-99m pyrophosphate.

Technetium-99m-labeled pyrophosphate and radiolabeled antimyosin antibodies are two infarct localizing agents with apparently different kinetics of localization. To determine whether these agents localize in a similar fashion in early acute myocardial necrosis, we studied the simultaneous distribution of 111In-labeled antimyosin and 99mTc-labeled pyrophosphate in dogs after intracoronary (i.c.) (n = 9) or intravenous (i.v.) (n = 9) administration of a mixture of these two agents in a reperfused infarct model. The mean infarct size (+/- s.d.) delineated by pyrophosphate [20.2 +/- 14.1 (i.v.), 29.8 +/- 12.3 (i.c.)] was larger than that by antimyosin [14.2 +/- 11.3 (i.v.) (p = 0.05), 20.0 +/- 11.8 (i.c.) (p = 0.05)] which was larger than that by triphenyl tetrazolium chloride [13.9 +/- 8.0 (i.v.) (p = 0.05), 15.3 +/- 6.5 (i.c.) (p = 0.05)]. This overestimation persisted whether the radiopharmaceuticals were administered by intracoronary or intravenous injections, although the latter with antimyosin was only slightly larger (TTC:AM = 13.9:14.2) (p = n.s.). There was a good correlation, however, between antimyosin and pyrophosphate delineated infarct sizes in dogs with intracoronary injection (y = 0.82x + 13.33, r = 0.79) or i.v. injection (y = 1.208x + 3.01, r = 0.97) of the mixture of the two agents. Since the images of the 111In and 99mTc activities were obtained consecutively by identical methods, the overestimation of infarct size by pyrophosphate cannot be due to differences in spatial resolution of the techniques used. The differences in the areas of myocardial damage delineated by pyrophosphate and antimyosin in our study most probably denote the area of viable but compromised myocardium.

Animals↗

Acute myocardial infarct imaging with indium-111-labeled monoclonal antimyosin Fab.

Indium-111 monoclonal antimyosin Fab scintigraphy was used to detect myocardial necrosis in 52 of 54 patients (96.3%) with acute myocardial infarction. Infarcts were visualized when coronary arteries were persistently occluded (n = 10), became patent after thrombolysis (n = 33), or became patent after spontaneous reperfusion (n = 7). Posteroinferolateral visualizations were obtained in two patients with clinical and enzymatic evidence of infarction but normal electrocardiograms. Of the two patients in whom no infarcts were visualized, one had an anterior myocardial infarct. This patient underwent successful thrombolytic therapy, with attendant minimization of creatine kinase release. The other patient had a small, nonreperfused inferior myocardial infarct. Five patients with a history of remote infarction and acute necrosis showed antimyosin uptake only in regions concordant with the acute episodes of infarction, and radiolabeled antimyosin Fab localized in neither old infarcts nor normal, noninfarcted myocardium. Antimyosin Fab scintigraphy, thus, appears to be a highly specific means of delineating necrotic myocardium, at least in this limited and selected group of patients.

Antibodies, Monoclonal↗

Dose-dependent thrombolysis, pharmacokinetics and hemostatic effects of recombinant human tissue-type plasminogen activator for coronary thrombosis.

The pharmacokinetics, thrombolytic profile and effects on hemostasis of graded intravenous doses of recombinant human tissue-type plasminogen activator (rt-PA) were studied in 45 patients with acute myocardial infarction. Infusion of rt-PA at a rate of 4 to 8.3 micrograms/kg/min resulted in plateau levels of the drug in plasma of 0.52 to 1.4 micrograms/ml. A linear relation between infusion rate and plasma rt-PA concentration was observed, although plasma drug levels varied substantially among subjects who received infusions at the same rate. The ratio between plateau levels of rt-PA in plasma and infusion rate was inversely related to initial distribution volume (7.3 +/- 2.9 liters, n = 21). The decline in plasma concentration of rt-PA, x(t), as a function of time after cessation of the infusion, was described adequately by the biexponential equation: x(t) = 0.71exp(-0.13t) + 0.29exp(-0.015t). The initial and terminal half-lives of rt-PA in the blood were 5.3 +/- 1.7 and 46.2 +/- 14 minutes, respectively. The efficacy of rt-PA for coronary thrombolysis was dose-dependent. With 4 micrograms/kg/min of rt-PA for 90 minutes, no reperfusion was achieved, whereas infusion rates of 5 micrograms/kg/min or more for 90 minutes accomplished reperfusion in more than 80% of the patients. However, the frequency of occurrence of residual intraluminal thrombus was significantly lower with an infusion rate of 7 micrograms/kg/min for 90 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Thrombosis↗

Spontaneous changes in regional wall motion abnormalities in acute myocardial infarction.

The incidence of improvement in regional wall motion of segments with severe contractile abnormalities in the first 10 days after a first acute myocardial infarction (AMI) was assessed with serial gated blood pool scans in 95 patients who received standard medical therapy. Regional wall motion was quantitatively assessed as percent chord shortening in 4 segments in the anterior view and 4 segments in the 45 degree left anterior oblique view. Among 237 segments with no more than 15% shortening (severely hypokinetic or akinetic [SH/A] segments), 59 (25%) improved at least 15% at 10 days, 166 (70%) did not change and 12 (5%) deteriorated by at least 15%. Among 91 patients who had SH/A segments, 37 (41%) had improvement in at least 1 SH/A segment (group 1) and 54 had no improvement in SH/A segments (group 2). Group 1 had a higher initial ejection fraction (EF) (50 +/- 12%) than group 2 (45 +/- 13%, p less than 0.05). The changes in percent shortening of SH/A segments were compared with coronary anatomy in 37 patients who underwent coronary angiography. The 17 patients with 1-vessel coronary artery disease (CAD) had significantly improved wall motion (8.2 +/- 13.4%, p less than 0.005), in contrast to the 20 patients with multivessel CAD (1.8 +/- 11.5%, difference not significant). Among patients with 1-vessel CAD, the improvement was greater in patients with right coronary or left circumflex artery disease (12.8 +/- 14.4%) than in those with left anterior descending disease (4.1 +/- 13.4%, p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗