"Magic-angle" phenomenon: a cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee.

OBJECTIVE: Increased signal intensity is frequently present in the upsloping, medial segment of the posterior horn of the normal lateral meniscus on routine short-TE MR images of the knee. This attribute can mimic or obscure abnormalities in this portion of the meniscus. In the present study, we examined whether this appearance could be accounted for by the "magic-angle" phenomenon resulting from the angular orientation of this meniscal segment relative to the static magnetic field. SUBJECTS AND METHODS: Fifty-eight consecutive knee MR examinations were studied. Sixteen were excluded because of frank evidence of preexisting abnormality of the lateral meniscus. In the remaining 42 examinations, the signal intensity in the medial segment of the posterior horn of the lateral meniscus on short-TE (< 20 msec) sequences was correlated with the angular alignment of this meniscal segment relative to the static magnetic field. In five asymptomatic volunteers, meniscal signal intensities were monitored as the leg was positioned in various degrees of abduction. RESULTS: Increased signal was present in the medial segment of the posterior horn of the lateral meniscus in 31 (74%) of the 42 patients. In 25 (81%) of these, this meniscal segment was oriented at 55-60 degrees. Increased signal intensity was also present in this meniscal segment in three (60%) of five asymptomatic knees imaged in the neutral position. In each of these, abduction of the leg decreased the meniscal signal by 52-80%. Pathologic evaluation of two menisci showed numerous concentrically arranged collagen fibers. CONCLUSION: Increased signal in the upsloping portion of the posterior horn of the lateral meniscus on short-TE images often is due to the magic-angle phenomenon rather than to meniscal degeneration or tear.

Adult↗

Cystic lesions around the knee joint: MR imaging findings.

A wide variety of cystic lesions may be encountered in the soft tissues and bones during routine MR imaging of the knee. These lesions represent encapsulated fluid collections and exhibit low signal intensity on T1-weighted images and high signal intensity on T2-weighted images because of their high content of free water. Many lesions produce clinical features suggestive of internal derangement of the knee, so correct MR diagnosis is needed to avoid unnecessary arthroscopy and to guide specific therapy. The purpose of this essay is to illustrate the MR appearance of cystic lesions that can be found around the knee and to explain the clinical features and significance of these lesions.

Bone Cysts↗

Morphometric X-ray absorptiometry of the spine: correlation in vivo with morphometric radiography. Study of Osteoporotic Fractures Research Group.

The diagnosis of vertebral fractures has been based on lateral thoracic and lumbar spine films and entails the determination of crush, endplate and wedge deformities of the vertebral bodies, generally between T4 and L4. Accuracy and precision of X-ray based morphometry are limited by geometric distortion and other technique-related factors. This paper proposes the use of morphometric X-ray absorptiometry (MXA) as a method which overcomes many of the limitations of morphometric radiography. MXA generates paired anteroposterior and lateral images of the spine using a scanning fan beam geometry that significantly reduces distortions inherent in the cone beam geometry used in conventional X-rays. Intra-observer precision of MXA on 41 subjects aged 65 years and older was 1 mm for vertebral height assessments and 4.7% for vertebral wedge parameters. Linear correlation with vertebral heights and wedge parameters on 32 subjects evaluated by both MXA and morphometric radiography demonstrated a root of the mean squared error of 2.1-2.4 mm and 7.0%, respectively. Vertebral deformities could be identified by MXA. The study documents the feasibility of MXA for the assessment of vertebral deformities. However, further investigation is needed to document the ability of MXA to diagnose prevalent and incident fractures.

Absorptiometry, Photon↗

Noninvasive bone mineral density measurement in the evaluation of osteoporosis.

Bone densitometry has developed considerably during the past several decades. Because the techniques have become more precise than before, osteoporotic patients can now be followed over time, allowing for assessment of disease or response to treatment. Several densitometry techniques have been shown to allow for the assessment of fracture risk. Factors other than density, however, additionally influence fracture risk. The next step will be the evaluation of microstructure and bone quality.

Aged↗

Bone density at various sites for prediction of hip fractures. The Study of Osteoporotic Fractures Research Group.

Women with low bone density in the radius or calcaneus are at increased risk of hip fracture. To see whether bone density of the hip measured by dual X-ray absorptiometry is a better predictor of hip fracture than measurements of other bones, we assessed bone density at several sites in 8134 women aged 65 years or more. 65 women had hip fractures during a mean follow-up of 1.8 years. Each SD decrease in femoral neck bone density increased the age-adjusted risk of hip fracture 2.6 times (95% CL 1.9, 3.6). Women with bone density in the lowest quartile had an 8.5-fold greater risk of hip fracture than those in the highest quartile. Bone density of the femoral neck was a better predictor than measurements of the spine (p < 0.0001), radius (p < 0.002), and moderately better than the calcaneus (p = 0.10). Low hip bone density is a stronger predictor of hip fracture than bone density at other sites. Efforts to prevent hip fractures should focus on women with low hip bone density.

Absorptiometry, Photon↗

Vertebral fracture assessment using a semiquantitative technique.

The assessment of vertebral fracture by conventional radiography has been refined and improved using either semiquantitative or quantitative criteria. The inter- and intraobserver variability was determined for a semiquantitative visual approach that we routinely use in clinical studies for assessing prevalent and incident vertebral fractures. In addition, the semiquantitative approach was compared with a quantitative morphometric approach. The incidence and prevalence of vertebral fractures were determined in 57 postmenopausal women (age 65-75 years) by three independent observers. The radiographic basis for fracture definitions and the source of interobserver agreement for the semiquantitative technique. We conclude that the semiquantitative approach can be applied reliably in vertebral fracture assessment when performed using well-defined criteria.

Aged↗

Simple measurement of femoral geometry predicts hip fracture: the study of osteoporotic fractures.

Based on engineering principles, geometric measurements of femoral size should be related to femoral strength and the risk for hip fracture. To evaluate whether a simple measurement of femoral geometry is associated with hip fracture risk, we obtained dual x-ray absorptiometry scans of the proximal femur on 8074 white women age 67 or older. During an average of 1.6 years of follow-up, 64 participants suffered hip fractures. In all fracture cases and in a random sample of 134 women who did not subsequently suffer a hip fracture, we measured hip axis length (the distance from greater trochanter to inner pelvic brim), neck width, and the neck/shaft angle on the scan printout, with the observer blinded to subsequent fracture status of the participant. Results were analyzed using multiple logistic models, and odds ratios were determined. After adjustment for age, each standard deviation decrease in femoral neck bone mineral density increased hip fracture risk 2.7-fold (95% confidence interval 1.7, 4.3), and each standard deviation increase in hip axis length nearly doubled the risk of hip fracture (odds ratio = 1.8; 95% CI 1.3, 2.5). The relationship between hip axis length and fracture risk persisted even after adjustment for age, femoral neck density, height, and weight. A longer hip axis length was associated with an increased risk of both femoral neck (OR = 1.9; 95% CI 1.3, 3.0) and trochanteric fractures (1.6; 1.0, 2.4). We found no significant association between the neck width (1.1; 0.8, 1.5) or the neck/shaft angle (1.4; 0.9, 2.2) and risk of hip fracture.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Hematopoietic bone marrow in the adult knee: spin-echo and opposed-phase gradient-echo MR imaging.

Hematopoietic bone marrow in the distal femur of the adult may be mistaken for a pathologic marrow process in magnetic resonance imaging of the knee. We investigated the incidence of hematopoietic marrow in the distal femur in a series of 51 adult patients and compared spin-echo (TR/TE in ms: 500/35, 2000/80) and opposed-phase gradient-echo (0.35 T, TR/TE in ms: 1000/30, theta = 75 degrees) magnetic resonance images. Zones with intermediate to low signal intensity on T1-weighted spin-echo and opposed-phase gradient-echo sequences representing hematopoietic marrow within high signal intensity fatty marrow were observed in 18 of the 51 patients. Five patterns of marrow signal reduction were identified; type 0: uniform high signal, i.e., no signal change; type I, focal signal loss; type II, multifocal signal loss without confluence; type III, confluent signal loss; and type IV, complete homogeneous reduction in marrow signal. Opposed-phase gradient-echo sequences demonstrated markedly greater red-yellow marrow contrast than conventional spin-echo sequences. Follow-up studies in three patients using a gradient-echo sequence with TE varying from 10 to 21 ms at 1-ms increments showed a cyclic increase and decrease in red and yellow marrow signal intensity depending on the TE. The contribution of intravoxel chemical shift effects on red-yellow marrow contrast in opposed-phase gradient-echo images was verified by almost complete cancellation of the TE-dependent marrow signal oscillation with use of a chemically selective pulse presaturating the water protons. Hematopoietic marrow in the adult distal femur in the absence of hematologic abnormalities is found primarily in women of menstruating age.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Cross-calibration of DXA equipment: upgrading from a Hologic QDR 1000/W to a QDR 2000.

In this study, the cross-calibration of a fan beam DXA system (Hologic QDR-2000) to a pencil beam scanner from the same manufacturer (Hologic QDR-1000/W) is described. The scanners were calibrated by the manufacturer using the same anthropomorphic spine phantom at installation. To verify consistent machine calibration, a group of 69 female subjects, aged 46-75, had anteroposterior (AP) spine and proximal femur scans on the QDR-1000/W followed by pencil and array scans of the same sites on the QDR-2000 during the same visit. Many of the subjects had bilateral examinations of the proximal femur for a total of 123 hip scans. Pencil and array area, bone mineral content (BMC), and bone mineral density (BMD) from the QDR-2000 were compared with the values obtained on the QDR-1000/W, and linear regression equations were derived for relating the two instruments. At the spine, no differences were found between the QDR-1000/W BMD values and the QDR-2000 array BMD values. A slight difference between pencil beam modes was detected but was not deemed clinically significant. Linear regression models relating the QDR-2000 and QDR-1000/W AP spine BMD measurements showed correlation coefficients greater than 0.99, with slopes of 1.00, intercepts equivalent to zero, and small root mean square errors. Comparisons at the proximal femur showed equivalency at the femoral neck and trochanter regions for the two machines in pencil mode, but slight increases in BMC and BMD at the other femoral sites on the QDR-2000 in both pencil and array mode. Correlation coefficients were 0.97-0.99 for all measurement regions except for Ward's.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data.

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women.

We evaluated the ability of bone density and vertebral fractures at baseline to predict vertebral fracture incidence in a cohort of postmenopausal women with osteoporosis. The study population was 380 postmenopausal women (mean age 65 years) treated for osteoporosis in a randomized, placebo-controlled, clinical trial of the bisphosphonate etidronate at seven geographic centers in the United States. Baseline measurements of bone mineral density were obtained in 1986 by quantitative computed tomography at the spine and dual-photon absorptiometry at the lumbar spine and hip. Vertebral fractures were documented on serial spine radiographs. Proportional hazards models were used to evaluate the ability to predict the risk of subsequent fractures during an average of 2.9 years of follow-up. Presence of one or two fractures increased the rate of new vertebral fractures 7.4-fold (95% confidence interval = 1.0 to 55.9). Additional fractures at baseline further increased the fracture rate. A decrease of 2 standard deviations in spinal bone density by absorptiometry was associated with a 5.8-fold increase in fracture rate (95% confidence interval = 2.9 to 11.6). The lowest and highest quintiles of bone density had absolute fracture rates of 120 and 6 cases per 1000 patient-years, respectively. In general, the simultaneous use of two predictors (bone density and prevalent fractures or two bone density measurements) improved fracture prediction, compared with the use of a single predictor. We conclude that both bone density and prevalent vertebral fractures are strong, complementary predictors of vertebral fracture risk. The results suggest that physicians can use bone density and prevalent vertebral fractures, individually or in combination, as risk factors to identify patients at greatest risk of new fractures.

Aged↗