Search PubMed⌕ Search

Biomedical subjects

H J Kreuzer

Publications and source records attributed to H J Kreuzer.

12 recordsLinked to original sources

Comment on "Reconstruction algorithm for high-numerical-aperture holograms with diffraction-limited resolution".

We comment on a recent Letter by Zhang et al. [Opt. Lett. 31, 1633 (2006)] in which the authors proposed a reconstruction algorithm for high-numerical-aperture (NA) holograms. Such an algorithm has been available for in-line holography for more than a decade. The authors' "achievement" of high NA for digital in-line holography, NA=0.17, is below what was reported already several years ago (NA=0.30) and is considerably lower than what is routinely achieved now. We present reconstructions of holograms acquired with NAs above 0.4 in which we show maximal achievable resolution.

Comment↗

Theoretical modeling and interpretation of X-ray absorption spectra of liquid water.

We report extensive calculations to examine the capability of theory to explain the XAS spectra of liquid water. Several aspects that enter the theoretical model are addressed, such as the quantum mechanical methods, the statistics and the XAS model. As input into our quantum mechanical calculations we will use structural information on liquid water obtained from first principles and from classical molecular dynamics simulations. As XAS models, we will examine the full core hole and the half core hole approximations to transition state theory. The quantum mechanics is performed on the basis of density functional theory. We conclude from this study that recent experimental results are fully consistent with, and can be completely explained by, present day theory, in particular, the pre-edge peak is reproduced. We also find that the average bond coordination in liquid water is 3.1 and that the assertion in a recent paper that the hydrogen bond number is much less than that cannot be substantiated. Our calculations emphasize that further advances in our understanding of water can only be made by more sophisticated spectroscopy with significantly increased resolution.

Absorption↗

Oxygen adsorption on gold nanofacets and model clusters.

We have studied oxygen interaction with Au crystals (field emitter tips) using time-resolved (atom-probe) field desorption mass spectrometry. The results demonstrate no adsorption to take place on clean Au facets under chosen conditions of pressures (p < 10(-4) m/bar) and temperatures (T = 300-350 K). Steady electric fields of 6 V/nm do not allow dissociating the oxygen molecule. The measured O2+ intensities rather reflect ionization of O2 molecules at critical distances above the Au tip surface. Certain amounts of Au-O2 complex ions can be found at the onset of Au field evaporation. Calculations by density functional theory (DFT) show weak oxygen end-on interaction with Au10 clusters (Delta E = 0.023 eV) and comparatively stronger interaction with Au1/Au(100) model surfaces (Delta E = 0.25 eV). No binding is found on {210} facets. Including (positive) electric fields in the DFT calculations leads to an increase of the activation energy for oxygen dissociation thus providing an explanation for the absence of atomic oxygen ions from the field desorption mass spectra.

Journal Article↗

Field-induced CO adsorption and formation of carbonyl waves on gold nanotips.

We report a study of the adsorption and reaction of CO on a gold nanotip in high electrostatic fields. Field ion microscopy is used to investigate the emergence of a Au-carbonyl wave that is made visible with oxygen as the imaging gas. We set up a simple kinetic model that reproduces the adsorption wave and confirms that the presence of oxygen merely serves as an imaging gas and does not lead to field-induced oxidation of CO.

Journal Article↗

Immersion digital in-line holographic microscopy.

Digital in-line holographic microscopy is a promising new tool for high resolution imaging. We demonstrate, by using latex beads, that a considerable increase in numerical aperture, and, therefore, resolution can be achieved if the space between a source and a CCD camera chip is filled with a high refractive index medium. The high refractive index medium implies a shorter effective wavelength so that submicrometer resolution can be obtained with laser light in the visible range.

Holography↗

Tracking particles in four dimensions with in-line holographic microscopy.

We describe a simple holographic method that has enabled us to capture as a single data set the trajectories of micrometer-sized objects suspended in water. By subtracting consecutive holograms of a particle suspension and then adding these difference holograms, we constructed a final data set that contains the time evolution of the particle trajectories free from spurious background interference effects. The method is illustrated by a recording of the motion of 5-10-microm diameter algae in water.

Journal Article↗

Digital in-line holography of microspheres.

We have used digital in-line holography (DIH) with numerical reconstruction to image micrometer-sized latex spheres as well as ferrimagnetic beads suspended in gelatin. We have examined in detail theoretically and experimentally the conditions necessary to achieve submicrometer resolution of holographic reconstructions. We found that both transparent and opaque particles could be imaged with a resolution that was limited only by the wavelength of the light used. Simple inspection of intensity profiles through a particle allowed an estimate to be made of the particle's three position coordinates within an accuracy of a few hundred nanometers. When the derivative of a second-order polynomial fitted to the intensity profiles was taken, the X, Y, Z position coordinates of particles could be determined within +/-50 nm. More-accurate positional resolution should be possible with the help of more-advanced computer averaging techniques. Because a single hologram can give information about a large collection of distributed particles, DIH offers the prospect of a powerful new tool for three-dimensional tracking of particles.

Holography↗

Photo- and thermodesorption of helium on Pt(111).

In a detailed study of thermal desorption of monolayers of both 4He and 3He adsorbed on Pt(111) (binding energy about 9 meV), we have observed photodesorption induced by the blackbody radiation from a room temperature environment. This process proceeds independently of the thermal desorption. Theoretical treatments of both thermal and photodesorption are given and agree very well with the data in all important aspects. We conclude that the photodesorption is due to direct coupling of photons to the adsorbate.

Journal Article↗

Optimization of the low energy electron point source microscope: imaging of macromolecules.

Optimal conditions for low energy electron point source microscopy are investigated by the simulation and numerical reconstruction of holograms of phthalocyaninato polysiloxane, PcPS, a rod-like macromolecule. The effects of the electron energy, width of the electron beam and the detector size on the spatial resolution in the reconstructed images are modeled. We find that for electron energies around 200eV, with the specimen 0.1 microm from the source, a screen recording the image in a cone of at least 15 degrees half angle (7 cm lateral dimension at 10 cm from the source) with at least 512 x 512 pixel and 8-bit resolution will result in near atomic resolution.

Journal Article↗

Digital in-line holography for biological applications.

Digital in-line holography with numerical reconstruction has been developed into a new tool, specifically for biological applications, that routinely achieves both lateral and depth resolution, at least at the micron level, in three-dimensional imaging. The experimental and numerical procedures have been incorporated into a program package with a very fast reconstruction algorithm that is now capable of real-time reconstruction. This capability is demonstrated for diverse objects, such as suspension of microspheres and biological samples (diatom, the head of Drosophila melanogaster), and the advantages are discussed by comparing holographic reconstructions with images taken by using conventional compound light microscopy.

Algorithms↗

Stretching a macromolecule in an atomic force microscope: statistical mechanical analysis.

We formulate the proper statistical mechanics to describe the stretching of a macromolecule under a force provided by the cantilever of an atomic force microscope. In the limit of a soft cantilever the generalized ensemble of the coupled molecule/cantilever system reduces to the Gibbs ensemble for an isolated molecule subject to a constant force in which the extension is fluctuating. For a stiff cantilever we obtain the Helmholtz ensemble for an isolated molecule held at a fixed extension with the force fluctuating. Numerical examples are given for poly (ethylene glycol) chains.

Biophysical Phenomena↗

Stretching a macromolecule in an atomic force microscope: statistical mechanical analysis.

We formulate the proper statistical mechanics to describe the stretching of a macromolecule under a force provided by the cantilever of an Atomic Force Microscope. In the limit of a soft cantilever, the generalized ensemble of the coupled molecule-cantilever system reduces to the Gibbs ensemble for an isolated molecule subject to a constant force in which the extension is fluctuating. For a stiff cantilever, one obtains the Helmholtz ensemble for an isolated molecule held at a fixed extension with the force fluctuating. Numerical examples and predictions for experiments with cantilevers of differing stiffness are given for short and long chains of poly (ethylene glycol), based on parameter-free ab initio calculations.

Biomechanical Phenomena↗