Search PubMed⌕ Search

Biomedical subjects

H Iida

Publications and source records attributed to H Iida.

At least 217 records · Page 12Linked to original sources

Noninvasive quantification of regional myocardial metabolic rate of oxygen by 15O2 inhalation and positron emission tomography. Experimental validation.

BACKGROUND: The purpose of this study was to validate a novel method for noninvasive quantification of regional myocardial oxygen consumption (MMRO2, mL.min-1 x 100 g-1) and oxygen extraction fraction (OEF) by use of positron emission tomography (PET) and inhalation of 15O-labeled molecular oxygen gas (15O2). METHODS AND RESULTS: Twenty-four measurements were performed in eight closed-chest anesthetized greyhounds at baseline and during infusions of adenosine (100 to 200 micrograms.kg-1.min-1), isoproterenol (1 to 10 microgram/min), and propranolol (5 mg botus +0.2 to 1 mg/min) with morphine (5 mg slow infusion +0.2 to 0.5 mg/ min) to obtain a wide range of oxidative metabolism. The PET imaging protocol consisted of 15O2 emission (OEF and MMRO2), transmission, [15O]CO emission (blood pool), and [15O]CO2 emission (myocardial blood flow: MBF(pets) mL.min-1.g-1) scans. OEF was calculated from the PET data (OEFpet) by three different analytical techniques: steady-state, 5-minute, and 8-minute autoradiographic analyses. Reference measurements of MBF (MBFref) and OEF (OEFref) were obtained during 15O2 inhalation with radiolabeled microspheres and paired arterial and coronary sinus blood sampling, respectively. MMRO2 was calculated from the PET (MMRO2pet) and the reference (MMRO2ref) data as follows: MMRO2 = OEF x MBF x (O2 content of arterial blood). OEF measured by the steady-state PET method was well correlated with the reference data over the range 0.16 to 0.73 (OEFpet = 1.03 OEFref -0.01, r = .97), as was MMRO2 over the range 2.4 to 27.5 mL.min-1 x 100 g-1 (MMRO2pet = 0.98 MMRO2ref +0.91, r = .94). OEFpet calculated by use of the 5-minute and 8-minute autoradiographic analyses were equally well correlated with the reference measurements (r = .95 and r = .97, respectively). There were no significant differences between values of MMRO2pet calculated by use of the steady-state, 5-minute, and 8-minute autoradiographic analyses (P = NS by ANOVA). Regional values of MBFpet, OEFpet, and MMRO2pet were homogeneously distributed and similar to the whole-heart values both at baseline and during the various pharmacological interventions. CONCLUSIONS: Accurate quantification of OEF and MMRO2 is feasible with 15O2 inhalation and PET imaging using both the steady-state and autoradiographic analytical approaches. These studies suggest the applicability of this method for quantitative assessments of regional cardiac oxidative metabolism in clinical studies.

Adenosine↗

Glucose uptake in the chronically dysfunctional but viable myocardium.

BACKGROUND: The regulation of glucose uptake in the dysfunctional but viable myocardium has not been studied previously in humans. METHODS AND RESULTS: Seven patients with an occluded major coronary artery but no previous infarction were studied twice with 2-[(18)F]fluoro-2-deoxy-D-glucose positron emission tomography, once in the fasting state and once during hyperinsulinemic euglycemic clamping. Myocardial blood flow was measured with [(15)O]H2O. The myocardial region beyond an occluded artery that showed stable wall-motion abnormality represented chronically dysfunctional but viable tissue. Six of the patients were later revascularized, and wall-motion recovery was detected in the corresponding regions, which confirmed viability. A slightly reduced myocardial blood flow was detected in the dysfunctional than in the remote myocardial regions (0.81 +/- 0.27 versus 1.02 +/- 0.23 mL x g(-1) x min(-1),P=.036). In the fasting state, glucose uptake was slightly increased in the dysfunctional regions compared with normal myocardium (15 +/- 10 versus 11 +/- 10 micromol/100 g per minute, P=.038). During insulin clamping, a striking increase in glucose uptake by insulin was obtained in both the dysfunctional and the normal regions (72 +/- 22 and 79 +/- 21 micromol/100 g per minute, respectively; P<.001, fasting versus clamping). CONCLUSIONS: Contrary to previous suggestions, glucose uptake can be increased strikingly by insulin in chronically dysfunctional but viable myocardium. This demonstrates that insulin control over glucose uptake is preserved in the dysfunctional myocardium and provides a rational basis for metabolic intervention.

Aged↗

Role of blood flow in regulating insulin-stimulated glucose uptake in humans. Studies using bradykinin, [15O]water, and [18F]fluoro-deoxy-glucose and positron emission tomography.

Defects in insulin stimulation of blood flow have been used suggested to contribute to insulin resistance. To directly test whether glucose uptake can be altered by changing blood flow, we infused bradykinin (27 microgram over 100 min), an endothelium-dependent vasodilator, into the femoral artery of 12 normal subjects (age 25+/-1 yr, body mass index 22+/-1 kg/m2) after an overnight fast (n = 5) and during normoglycemic hyperinsulinemic (n = 7) conditions (serum insulin 465+/-11 pmol/liter, 0-100 min). Blood flow was measured simultaneously in both femoral regions using [15O]-labeled water ([15O]H2O) and positron emission tomography (PET), before and during (50 min) the bradykinin infusion. Glucose uptake was measured immediately after the blood flow measurement simultaneously in both femoral regions using [18F]-fluoro-deoxy-glucose ([18F]FDG) and PET. During hyperinsulinemia, muscle blood flow was 58% higher in the bradykinin-infused (38+/-9 ml/kg muscle x min) than in the control leg (24+/-5, P<0.01). Femoral muscle glucose uptake was identical in both legs (60.6+/-9.5 vs. 58.7+/-9.0 micromol/kg x min, bradykinin-infused vs control leg, NS). Glucose extraction by skeletal muscle was 44% higher in the control (2.6+/-0.2 mmol/liter) than the bradykinin-infused leg (1.8+/-0.2 mmol/liter, P<0.01). When bradykinin was infused in the basal state, flow was 98% higher in the bradykinin-infused (58+/-12 ml/kg muscle x min) than the control leg (28+/-6 ml/kg muscle x min, P<0.01) but rates of muscle glucose uptake were identical in both legs (10.1+/-0.9 vs. 10.6+/-0.8 micromol/kg x min). We conclude that bradykinin increases skeletal muscle blood flow but not muscle glucose uptake in vivo. These data provide direct evidence against the hypothesis that blood flow is an independent regulator of insulin-stimulated glucose uptake in humans.

Adult↗

Quantitative evaluation of neutral amino acid transport in cerebral gliomas using positron emission tomography and fluorine-18 fluorophenylalanine.

To elucidate the mechanism of large neutral amino acid (LNAA) transport in cerebral gliomas and to evaluate the clinical usefulness of positron emission tomography (PET) with fluorine-18 fluorophenylalanine (18F-Phe), we examined 18 patients with cerebral glioma using dynamic PET and 18F-Phe. By employing two-compartment model analysis, the influx rate K1, the efflux rate k2 and the distribution volume (Vd) of 18F-Phe were estimated in tumour tissue and contralateral normal grey matter. 18F-Phe showed increased accumulation in tumour tissue regardless of the grade of malignancy in all patients. The rate of uptake of 18F-Phe in high-grade glioma was significantly higher than in low-grade glioma (P <0.05). However, it was difficult to evaluate the tumour grade only from the 18F-Phe accumulation in individual cases. Values of K1 and Vd were significantly increased in the tumour tissue. The K1 value of the tumour tissue tended to decrease with increasing LNAA concentration in plasma. Therefore, influx of 18F-Phe into tumour tissue is mainly related to the carrier-mediated active transport. It is concluded that PET with 18F-Phe is of clinical value for tumour detection rather than assessment of tumour malignancy.

Amino Acids↗

Coronary flow reserve is impaired in young men with familial hypercholesterolemia.

OBJECTIVES: We sought to investigate whether functional abnormalities in coronary vasomotion exist in young adults by studying 15 men (age 31 +/- 8 years [mean +/- SD]) with familial hypercholesterolemia (FH) and a matched group of 20 healthy control subjects. BACKGROUND: Precursors of morphologic coronary artery disease are known to be present in adolescents and young adults with a high risk factor profile. METHODS: Myocardial blood flow was measured at the basal state and during dipyridamole-induced hyperemia using positron emission tomography and oxygen-15-labeled water. RESULTS: Serum total and low density lipoprotein cholesterol concentrations were higher in the patients than in the control subjects (mean +/- SD): 7.7 +/- 1.9 versus 5.3 +/- 1.5 mmol/liter (298 +/- 73 vs. 205 +/- 58 mg/dl) and 6.1 +/- 1.8 versus 3.5 +/- 1.4 mmol/liter (236 +/- 70 vs. 135 +/- 54 mg/dl), respectively (both p < 0.001). The baseline myocardial blood flow was similar in the patients and control subjects: 0.92 +/- 0.24 versus 0.83 +/- 0.13 ml/g per min, respectively (p = 0.21). A significant increase in flow was observed in both groups after dipyridamole infusion, but the flow at maximal vasodilation was 29% lower in the patients: 3.19 +/- 1.59 versus 4.49 +/- 1.27 ml/g per min (p = 0.011). Consequently, coronary flow reserve (the ratio of hyperemia flow to basal flow) was 35% lower in the patients than in the control subjects: 3.5 +/- 1.6 versus 5.4 +/- 1.5 (p = 0.0008). Total coronary resistance during hyperemia was higher in the patients than in the control subjects: 36 +/- 25 versus 21 +/- 10 mm Hg/min per g per ml (p = 0.045). Coronary flow reserve was inversely associated with serum total cholesterol concentration: r = -0.43 (p = 0.009). CONCLUSIONS: Coronary flow reserve is reduced in young men with FH, and, consequently, coronary resistance during hyperemia is increased. The results demonstrate very early impairment of coronary vasomotion in hypercholesterolemic patients.

Adult↗

Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT.

Scatter correction is a prerequisite for quantitative SPECT, but potentially increases noise. Monte Carlo simulations (EGS4) and physical phantom measurements were used to compare accuracy and noise properties of two scatter correction techniques: the triple-energy window (TEW), and the transmission dependent convolution subtraction (TDCS) techniques. Two scatter functions were investigated for TDCS: (i) the originally proposed mono-exponential function (TDCSmono) and (ii) an exponential plus Gaussian scatter function (TDCSGauss) demonstrated to be superior from our Monte Carlo simulations. Signal to noise ratio (S/N) and accuracy were investigated in cylindrical phantoms and a chest phantom. Results from each method were compared to the true primary counts (simulations), or known activity concentrations (phantom studies). 99mTc was used in all cases. The optimized TDCS(Gauss) method overall performed best, with an accuracy of better than 4% for all simulations and physical phantom studies. Maximum errors for TEW and TDCS(mono) of -30 and -22%, respectively, were observed in the heart chamber of the simulated chest phantom. TEW had the worst S/N ratio of the three techniques. The S/N ratios of the two TDCS methods were similar and only slightly lower than those of simulated true primary data. Thus, accurate quantitation can be obtained with TDCS(Gauss), with a relatively small reduction in S/N ratio.

Air↗

Minimum cross-entropy reconstruction of PET images using prior anatomical information.

An algorithm is presented for the reconstruction of PET images using prior anatomical information derived from MR images of the same subject. The cross-entropy or Kullback-Leiber distance is a measure of dissimilarity between two images. We propose to reconstruct PET images by minimizing a weighted sum of two cross-entropy terms. The first is the cross-entropy between the measured emission data and the forward projection of the current estimate of the PET image. Minimizing this term alone is equivalent to the ML-EM reconstruction. The second term is the cross-entropy between the current estimate of the PET image and a prior image model which incorporates anatomical information derived from registered MR images. A weighting parameter determines the relative emphasis given to the emission data and the prior model in the reconstruction. Details of this algorithm are presented as well as test reconstructions for real and simulated data. The performance of the algorithm was evaluated with respect to errors in prior anatomical information. The algorithm provided significant improvement in the quality of reconstructed images as compared with the ML-EM reconstruction technique. The reconstructed images had higher resolution as compared with the images obtained from MAP-like reconstructions which do not utilize anatomical information. The algorithm displayed robustness with respect to errors in prior anatomical information.

Algorithms↗

A multicenter validation of regional cerebral blood flow quantitation using [123I]iodoamphetamine and single photon emission computed tomography.

Recently, two methods have been proposed for regional cerebral blood flow (rCBF) quantitation using [123I]iodoamphetamine (IMP) and single-photon emission computed tomography (SPECT). The table look-up (TLU) method has been shown to provide both rCBF and volume of distribution, Vd, images from two SPECT scans, while a single-scan autoradiographic (ARG) technique provided rCBF using a fixed and assumed Vd. In both methods, a single blood sample was referred to calibrate the previously determined standard input function. The present multicenter project was designed to evaluate the accuracy of both methods for use as clinical investigative tools. Ten independent institutions performed [123I]IMP-SPECT studies according to both methods in 76 subjects (10 normal volunteers, 32 patients with cerebrovascular disease, and 34 patients with other diseases). Calculated rCBF values were compared with those obtained by the following reference methods available in the participating institutions; [15O] H2O positron emission tomography (PET) (five institutions), [133Xe]SPECT (four institutions), and the [123I]IMP microsphere method (three institutions). Both ARG and TLU methods provided rCBF values that were significantly correlated with those measured by the [15O] H2O PET technique (p < 0.001 for all subjects; overall regression equation, y = 15.14 + 0.54x) and those measured by the [123I]IMP-microsphere method (p < 0.001 for all subjects: y = 2.0 + 0.80x). Significant correlation (p < 0.05) was observed in 18 of 24 subjects studied with the [133Xe] SPECT reference technique (overall regression equation, y = 15.0 + 0.55x). Mean cortical gray matter rCBF in a group of normal subject was 43.9 +/- 3.3 and 43.4 +/- 2.0 ml/min/100 g for the ARG and TLU methods, respectively. Regional Vd of [123I]IMP estimated by the TLU method was 45 ml/ml +/- 20% in the normal cortical region. Close agreement between ARG and TLU rCBF values was observed (y = -3.21 + 1.07x, r = 0.97), confirming the validity of assuming a fixed Vd in the ARG method. Results of this study demonstrate that both the ARG and TLU methods accurately and reliably estimate rCBF in a variety of clinical settings.

Adolescent↗

Identification of rab12 as a secretory granule-associated small GTP-binding protein in atrial myocytes.

A subfamily of small GTP-binding proteins, rab, has been shown to be involved in regulation of vesicular traffic in eukaryotic cells. The goal of this study was to identify the rab proteins associated with atrial secretory granules. A [32P]GTP-overlay assay showed the presence of multiple small GTP-binding proteins on the atrial granules. By biochemical analysis, we have demonstrated that one of the small GTP-binding proteins associated with the atrial granules is a rab12 protein (rab12p), one of the rab proteins that are most closely related to a Sec4 protein of yeast. Association of rab12p with the atrial granules was confirmed by immunogold electron microscopy. Immunoprecipitation followed by immunoblot analysis with anti-rab12 antibody showed that in addition to atria, rab12p was expressed in multiple other organs and cell lines. These results suggest that rab12p may function in vesicular traffic in multiple diverse types of cells.

Animals↗

Experimental studies on bovine Hyena disease induced by administration of excessive vitamin AD3E premix, vitamin A, or vitamin D3.

The effects of the excessive administration of the vitamin AD3E(V-AD3E) premix, vitamin A (V-A) or vitamin D3 (V-D3) on experimental development of Hyena disease in the calves were examined. Hyena disease was recognized in 4 calves, both of the 2 calves administered a high dose of V-AD3E premix (V-A 3,000,000, V-D3 300,000, and V-E 1,200 IU/day, V-AD3E group), 1 of the 2 calves administered a half dose of the V-AD3E premix, and 1 of the 2 calves administered only V-A (V-A 3,000,000 IU/day, V-A group) when each vitamin was administered orally for 10 days from 1 week after birth. Both of 2 calves administered only V-D3 (V-D3 300,000 IU/day) did not developed. In the 4 calves with Hyena disease (Hyena calves), the plasma retinylpalmitate showed high values which was suggesting the hypervitaminosis A, and the epiphysial growth plate was narrow and destroyed structure of column. Compared with the Hyena calf in the V-A group, the Hyena calves in the V-AD3E group showed earlier appearance time of Hyena disease, lower growth rate and shorter lengths of fore and hind limb bones. In conclusion, the present findings suggested that excessive V-A administration to suckling calves might cause Hyena disease by V-A effects to the epiphysial growth plate, moreover such effects may be promoted by the V-D3.

Aging↗

Colocalization of connexin 43 and connexin 45 but absence of connexin 40 in granulosa cell gap junctions of rat ovary.

The expression and localization of gap junction family proteins (connexins) were examined in nonstimulated and gonadotrophin-stimulated ovarian follicles of immature rats. Immunoblot and RNA blot analysis showed the presence of connexin (Cx) 43, Cx40 and Cx45 in ovarian tissue. Of these connexin proteins, Cx43 and Cx45 were identified by immunofluorescent microscopy between granulosa cells in characteristic expression patterns related to follicular developmental stages, while Cx40 was not expressed in granulosa cells but was detected in blood vessels in ovarian stroma. In some plaques of gap junction between granulosa cells, Cx45 was found to be colocalized with Cx43. In immunofluorescent microscopy, the expression of Cx43 was increased with follicular growth, but decreased after induction of ovulation by injection of human chorionic gonadotrophin. In contrast, the Cx45 protein was constantly expressed through follicular development; however, after ovulation, no staining of Cx45 was detected in the corpus luteum. Dual expression and the functional role of Cx43 and Cx45 in cell-to-cell communication in ovarian granulosa cells at various developmental stages were discussed.

Animals↗

Evidence for dissociation of insulin stimulation of blood flow and glucose uptake in human skeletal muscle: studies using [15O]H2O, [18F]fluoro-2-deoxy-D-glucose, and positron emission tomography.

We determined the effect of insulin on muscle blood flow and glucose uptake in humans using [15O]H2O, [18F]fluoro-2-deoxy-D-glucose ([18F]FDG), and positron emission tomography (PET). Femoral muscle blood flow was measured in 14 healthy volunteers (age 34 +/- 8 years, BMI 24.6 +/- 3.4 kg/m2 [means +/- SD]) before and at 75 min during a 140-min high-dose insulin infusion (serum insulin 2,820 +/- 540 pmol/l) under normoglycemic conditions. A dynamic scan of the femoral region was performed using PET for 6 min after injection of [15O]H2O to determine the 15O concentration in tissue. Regional femoral muscle blood flow was calculated using an autoradiographic method from the dynamic data obtained with PET and [15O]H2O. Femoral muscle glucose uptake was measured during hyperinsulinemia immediately after the flow measurement using PET-derived [18F]FDG kinetics and a three-compartment model. Whole-body glucose uptake was quantitated using the euglycemic insulin clamp technique. In the basal state, 84 +/- 8% of blood flow was confined to skeletal muscle. Insulin increased leg blood flow from 29 +/- 14 to 54 +/- 29 ml x kg-1 leg x min-1 (P < 0.001) and muscle flow from 31 +/- 18 to 58 +/- 35 ml x kg-1 muscle x min-1 (P < 0.005). Under insulin-stimulated conditions, 81 +/- 8% of blood flow was in muscle tissue (NS versus basal). Skeletal muscle explained 70 +/- 25% of the increase in leg blood flow. No correlation was observed between blood flow and glucose uptake when analyzed individually in identical regions of interest within femoral muscles. These data demonstrate that skeletal muscle accounts for most of the insulin-induced increase in blood flow. Insulin-stimulated rates of blood flow and glucose uptake do not colocalize in the same regions of muscle tissue, suggesting that insulin's hemodynamic and metabolic effects are differentially regulated.

Adult↗

[Observation of relation between object size or length and count rate for 3D PET].

We obtained the concentration range of better S/N in 3D than 2D acquisition by measuring count rate for phantoms of different size and length. We used noise equivalent count rate (NECR) for evaluation of S/N of images. For 20 cm diameter 15 cm length cylindrical phantom, NECR of 2D was higher than that of 3D more than 1.2 microCi/ml. For 30 cm diameter 15 cm length cylindrical phantom, NECR of 2D was higher than that of 3D more than 0.7 microCi/ml. For 14 cm diameter 25 cm length cylindrical phantom, NECR of 3D was lower than that of 25 cm length phantom. With these results, though 3D is useful when administered dose is small, image quality of 2D becomes better than 3D more than a certain concentration. For the larger diameter or longer object, the advantage of 3D is diminished at lower concentration.

Body Constitution↗

[Effects of compton scatter in quantitative brain SPECT].

Effects of Compton scatter has been investigated for quantitative single-photon emission computed tomography. Using a technique proposed by Ichihara and Ogawa (triple-energy window method) as a gold standard, effects of correcting the scatter has been evaluated for 5 different phantom configurations, as well as a clinical cerebral blood flow study with use of 123I-IMP. Without the scatter correction but with a correction for attenuation, a conventional reconstruction provided a non-uniform distribution for uniform phantom configurations, and the quantitative pixel counts being highly dependent on size and shape of the objects. On the other hand, a uniform distribution and quantitative pixel counts that were independent of size or shape of the object were obtained by applying the scatter correction using a conventional attenuation correction technique with use of a theoretical mu value of 0.146 cm-1, thus suggesting importance of the scatter correction. Similar results were observed without the scatter correction, if an empirical value of mu of 0.07 cm-1 was used in the attenuation correction. However, this procedure was found to decrease the image contrast between the high count and low count regions. Significant underestimation of 20-30% was caused in cortical gray matter regions, and overestimation of 20% in the white matter regions. In practical clinical studies, magnitude of the error is still unknown, and is probably dependent on shape, size and radioactivity distribution of the object. A further systematic study is required in order to investigate significance of the scatter correction in real clinical studies.

Adult↗

[Development of a front shield for a 3D positron emission tomograph].

Accidental coincidence rate and scatter coincidence rate of 3-dimensional (3D) acquisition of positron emission tomograph (PET) are higher than 2-dimensional (2D) acquisition and count loss becomes higher because slice shield collimator is not used in 3D acquisition. If one could decrease the gamma ray from outside of the axial field of view (FOV), it may be possible to improve image quality of 3D acquisition. Thus, using a Shimadzu SET-2300W (Headtome V) PET camera, we developed and tested a front shield for brain study to shut off gamma ray from the outside of the axial FOV. Using the front shield, gamma ray from outside of the FOV and the accidental coincidence rate could be decreased. The count loss in high count rate was also decreased. With these effect, the image quality of the clinical studies in 3D acquisition could be increased.

Brain↗

[Tizanidine for preanesthetic medication].

The effect of tizanidine given as a premedication on perioperative hemodynamics (mean blood pressure, heart rate), sedation, hypnosis and midazolam requirements for induction were assessed in 68 patients scheduled for elective surgery under general anesthesia. Patients were assigned to three groups. Group 1 was premedicated 90 min prior to induction with tizanidine 4 mg po (n = 28); group 2 was premedicated with tizanidine 2 mg po (n = 12); group 3 received no premedication (n = 28). In group 1, increase of mean blood pressure on anesthesia induction was attenuated significantly and sedative and hypnotic effects were stronger significantly compared with other groups. We also found that the amounts of midazolam necessary for loss of consciousness were significantly less in patients who had received tizanidine 4 mg. In conclusion, tizanidine is a useful drug as preanesthetic medication for general anesthesia.

Adjuvants, Anesthesia↗

[Hemocirculation and metabolism in intraventricular tumors: kinetic analysis of glucose metabolism].

To estimate hemocirculation and proliferating activity of intraventricular tumor, we measured kinetic rate constants (k1, k2, k3) and glucose metabolic rate (kinetic-rCMRGl) using dynamic positron emission tomography (PET), as well as regional cerebral blood flow (rCBF), blood volume (rCBV), oxygen extraction fraction (rOEF), oxygen metabolic rate (rCMRO2) and autoradiographic rCMRGl (arg-rCMRGl), in patients with intraventricular tumor. The subjects included ten patients, five males and five females, aged from 13 to 53 years with a mean age of 32 years old. Eight tumors were located in the lateral ventricle and two extended into the third ventricle through the foramen of Monro. Another two tumors were located in the fourth ventricle. Histological diagnosis was as follows: five cases of central neurocytoma, one subependymal giant cell astrocytoma, one ependymoma, one choroid plexus carcinoma, one subependymoma, and one meningioma. Tumor lesion on the PET images was determined using CT or MRI, which was performed at levels equivalent to those for the PET scans. For quantitative analysis, regions of interest (ROI) on PET images were delineated on the tumor and the contralateral gray matter. Hemocirculation (rCBF, rCBV) of the tumor was similar to or higher than that of the contralateral gray matter, which corresponded to neuroradiological findings of abundant tumor vessels. Oxygen metabolic parameters (rOEF, rCMRO2) were significantly lower than those of the contralateral gray matter. Especially, low rOEF resulted in an excessive blood flow beyond oxygen demand of the tumor. The raised metabolic rate (rCMRO2/rCMRGl), as compared with that of meningiomas or malignant gliomas, suggested aerobic glycolysis. The kinetic rate constants of tracer transport from blood to brain (k1), reverse transport from brain to blood (k2), and phosphorylation (k3) were analyzed according to the three-compartment model of 18F-fluorodeoxyglucose (18FDG). Tumor k1 and k2 values were similar to or higher than those of the contralateral gray matter, suggesting high permeability due to lack of blood-brain barrier and an abundant blood supply. Tumor k3 value, an indicator of hexokinase activity, and kinetic-rCMRGl were lower in six of eight patients. These six patients have been free from tumor recurrence or regrowth, postoperatively. In the other two patients, tumor kinetic-rCMRGl was similar to or higher than that of the contralateral gray matter, suggesting high activity of proliferation. However, one patient received irradiation and has been followed up, and the other received total resection and has shown no recurrence. Functional information concerning intraventricular tumor is obtained by PET analysis, and kinetic analysis of the rate constants is useful for interpreting a detailed metabolic process of glucose, and provides additional information on intraventricular tumor aggressiveness.

Adolescent↗