Search PubMed⌕ Search

Biomedical subjects

H I Glass

Publications and source records attributed to H I Glass.

At least 37 records · Page 2Linked to original sources

Criteria in radioisotope detection of venous thrombosis.

Forty-one patients out of a larger series undergoing elective surgery were examined for the presence of venous thrombosis in the legs by means of the (125)I-fibrinogen technique. The radioisotope data were analysed by three different methods. The percentage uptake was calculated and, by the generally accepted difference of 15%, 22 patients had evidence of thrombosis. The statistical index, which takes account of the errors due to radioactivity counting inherent in the percentage uptake calculation, indicated thrombosis in 36 patients. The relative uptake index, which allows for the errors due to unequal distribution of radioactivity throughout the normal limb as well as the errors due to radioactivity counting, provided evidence of thrombosis in a total of 34 patients, compared with only 22 patients when assessed by the "15%" criterion.

Diagnostic Errors↗

Gastric emptying of solid meals after truncal vagotomy and pyloroplasty in human subjects.

Gastric emptying of isotopically labelled solid meals was studied in normal human subjects and in patients at different intervals after truncal vagotomy and Heineke-Mikulicz pyloroplasty. One to four weeks after vagotomy and pyloroplasty gastric emptying was delayed grossly in some patients regardless of the completeness of vagotomy. Patients with gross delay had symptoms of gastric retention. Eight weeks later emptying had returned towards normal and one or more years after vagotomy and pyloroplasty emptying was within the normal range.A subthreshold dose of carbachol injected during the course of emptying of a meal in some of the postvagotomy patients had no detectable influence on the rate of emptying of the meal.

Carbachol↗

Use of 99 Tc m for the routine assessment of thyroid function.

(99)Tc(m)-pertechnetate is concentrated in the thyroid in the same way as iodide but it does not become organically bound. The uptake of (99)Tc(m) is a measure of the thyroid trap, and this measurement is satisfactory as a routine test in the diagnosis of thyrotoxicosis. The reproducibility of the method is such that suppression tests can be carried out when necessary even when uptake is within the normal range of 0.4-3%. (99)Tc(m) gives a low radiation dose to the thyroid and has certain other advantages over radioactive isotopes of iodine for early thyroid uptake measurements. It is particularly suitable when serial tests of thyroid function are required during treatment with an antithyroid drug.

Blood Proteins↗