Quantitative measurement of renal function using Ga-68-EDTA.

We studied renal function using a positron emission tomography with C15O gas and 68Ga-EDTA in 6 normal subjects (male, 21-77 years old). The blood volume (ml/100 g (kidney] was 19.2 +/- 1.8 for the one 21 years old subject and 11.8 +/- 2.0 for the rest (65-77 years old). The glomerular filtration rate (ml/min/100 g (kidney] was 57.8 +/- 1.1 for the 21 years old subject and 30.4 +/- 2.8 for the rest.

Aged↗

An alternative method of vascular anastomosis by laser: experimental and clinical study.

In vascular surgery, it is now very difficult to maintain the long-term patency after a conventional vascular anastomosis, especially for small-caliber vessels. A low-energy CO2 laser was experimentally employed to make a vascular anastomosis with only a few sutures. Subsequently, it could be confirmed that optimal conditions for vascular anastomosis by laser were 20-40 mW in output and 6-12 sec/mm in irradiation time. On the other hand, pressure tolerance test as well as tensile strength test and microscopic examinations at the sites of anastomoses by laser were compared with the conventional suture method. There were no significant differences between laser and suture methods. On the basis of the excellent results of this study, the laser was clinically applied for anastomoses of the peripheral vessels in 35 patients. The first clinical laser application in the world was successful in a 44-year-old female patient with chronic renal failure in 1985. All patients are doing well without any complications from vascular anastomosis by laser. From these experimental and clinical studies, it can be concluded that anastomosis by laser should be recommended for small-caliber vessels such as aortocoronary bypass surgery.

Adult↗

[A new method of vascular anastomosis by CO2 laser: experimental and clinical study].

It is difficult to maintain the long-term patency after conventional anastomosis especially for the small caliber vessels. Since 15 years we have performed aortocoronary bypass with suture materials for the patients with ischemic heart disease. There are some problems in maintaining the long-term patency of the bypass grafts. Low energy CO2 laser was utilized to make vascular anastomosis with a few stay sutures. Vascular anastomoses (side-to-side, end-to-end, end-to-side) were carefully made by CO2 laser in the regions of the femoral arteries and veins, the carotid arteries and jugular veins in dog. A-C bypass was also successfully carried out between the internal mammary artery and the left anterior descending artery under the beating heart in experiment. Outputs of 20-40 mW and irradiation times of 6-12 sec/mm were optimal conditions for anastomosis of the small caliber vessels. There were no problems in the intensity and the healing of the anastomotic sites in comparison with the conventional suture method. On the basis of these excellent experimental results a low energy CO2 laser was employed clinically for vascular anastomosis of the peripheral vessels in 28 patients with angina pectoris or chronic renal failure and cardiac failure. There were no complications such as bleeding and suture line aneurysm after surgery. In conclusion, vascular anastomosis by laser might be recommended in performing with safety and rapidity for small caliber vessels.