Measurement of back clearance.

With improvement in dialysis membranes, back filtration becomes the focus of study. Because new membranes that remove low molecular weight proteins, such as beta 2-microglobulin by diffusion are now available for clinical use, both back filtration and back diffusion become problems. This paper gives the mass transfer rate of solutes from the dialysate to blood compartment. As markers of toxic or antigenic substances, inulin (MW 5,200), lysozyme (MW 14,300), and alpha-lactoalbumin (MW 14,400) were used. The dialyzers tested were the CLSU-12W, AM-FP10, BK-1.0P, and FB-110U. The UFR controller set the flow rate on the blood side at 200, dialysate at 500, and ultrafiltration (QF) as 0 to 50 ml/min. Under these conditions, the inulin back clearance is 16 (CLSU) to 26 ml/min (FB), even if the QF is 50 ml/min, and is 10 to 34 ml/min for lysozyme at QF = 0 ml/min. Although a substantial amount of solute moves into the blood compartment, back clearance does not drastically decrease with increase in QF. To avoid contamination of the blood side, clean-up techniques for the dialysis line or online protein adsorber should be followed.

Antigens↗

Nondestructive evaluation by x-ray computed tomography of dialysate flow patterns in capillary dialyzers.

It is hard to evaluate dialysate flow patterns inside the fiber bundle of capillary dialyzers. The current study describes a novel determination of dialysate flow by x-ray computed tomography. The authors did steady and nonsteady state tracer experiments with adipiodone to observe the dialysate flow pattern in capillary dialyzers held vertically and horizontally. The hollow fibers were filled with paraffin to avoid permeation of adipiodone from the dialysate to blood compartment. In steady state tracer experiments, adipiodone solution (50 vol%) was injected into the dialysate compartment at a flow rate of 1.5 ml/min. Horizontal sectional dialysate flow patterns were observed every 2 cm from the point of the adipiodone injection. Adipiodone solution flowed along broken and twisted fiber bundles at dialysate flow rates ranging from 200 to 600 ml/min. In nonsteady state tracer experiments, dialysate was switched from pure water to adipiodone solution by solenoid-controlled valves after a steady state was reached, and adipiodone solution (2.4 vol%) was infused into the dialysate compartment for 30 sec at a flow rate of 500 ml/min. Vertical sectional dialysate flow patterns were observed every 2 sec after the start of adipiodone infusion. Values for dialysate flow velocity at the outer and inner regions of the fiber bundle were 3.5 and 0.6 cm/sec for the CA-170, and 1.4 and 0.7 cm/sec for the HF-200 capillary dialyzer, respectively. This study demonstrates the usefulness of x-ray computed tomography in visually and quantitatively determining dialysate flow patterns in capillary dialyzers.

Iodipamide↗