Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches.

PURPOSE: To investigate the dosimetric accuracy of commercial treatment planning systems used in intensity-modulated radiotherapy (IMRT) for thoracic cancer. METHODS AND MATERIALS: Clinical IMRT plans for lung and esophageal cancers and mesothelioma were used to investigate the accuracy of dose calculations from two commercial treatment planning systems (Pinnacle and Corvus systems). Dose distributions were measured with ion chambers and thermoluminescent dosimeters for individual IMRT fields and composite treatment plans in water phantoms and anthropomorphic phantoms. A Monte Carlo-based system was established to compute three-dimensional dose distributions to compare with the treatment planning system calculations. RESULTS: Dose calculations from the Pinnacle system were acceptable within 5% of the local dose or a 5-mm distance-to-agreement for 80% of the points measured with ion chambers, 74% of the points measured with thermoluminescent dosimeters, and 96% of the points compared with the Monte Carlo calculations. For the Corvus system, 89% of the points agreed with the measured dose and 98% agreed with the Monte Carlo calculations. Underestimation of the dose from the treatment planning system was found in the low-dose regions (<50% of the prescribed dose), possibly caused by inadequate modeling of the multileaf collimators. CONCLUSION: The Pinnacle and Corvus dose calculations were acceptable for thoracic IMRT in high-dose regions. Beam modeling is likely the most critical factor for the accuracy of IMRT dose calculations.

Algorithms↗

Dose-volume modeling of the risk of postoperative pulmonary complications among esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgery.

PURPOSE: The aim of this study was to investigate the effect of radiation dose distribution in the lung on the risk of postoperative pulmonary complications among esophageal cancer patients. METHODS AND MATERIALS: We analyzed data from 110 patients with esophageal cancer treated with concurrent chemoradiotherapy followed by surgery at our institution from 1998 to 2003. The endpoint for analysis was postsurgical pneumonia or acute respiratory distress syndrome. Dose-volume histograms (DVHs) and dose-mass histograms (DMHs) for the whole lung were used to fit normal-tissue complication probability (NTCP) models, and the quality of fits were compared using bootstrap analysis. RESULTS: Normal-tissue complication probability modeling identified that the risk of postoperative pulmonary complications was most significantly associated with small absolute volumes of lung spared from doses > or = 5 Gy (VS5), that is, exposed to doses < 5 Gy. However, bootstrap analysis found no significant difference between the quality of this model and fits based on other dosimetric parameters, including mean lung dose, effective dose, and relative volume of lung receiving > or = 5 Gy, probably because of correlations among these factors. The choice of DVH vs. DMH or the use of fractionation correction did not significantly affect the results of the NTCP modeling. The parameter values estimated for the Lyman NTCP model were as follows (with 95% confidence intervals in parentheses): n = 1.85 (0.04, infinity), m = 0.55 (0.22, 1.02), and D50 = 17.5 Gy (9.4 Gy, 102 Gy). CONCLUSIONS: In this cohort of esophageal cancer patients, several dosimetric parameters including mean lung dose, effective dose, and absolute volume of lung receiving < 5 Gy provided similar descriptions of the risk of postoperative pulmonary complications as a function of the radiation dose distribution in the lung.

Analysis of Variance↗

Risk factors for acute esophagitis in non-small-cell lung cancer patients treated with concurrent chemotherapy and three-dimensional conformal radiotherapy.

PURPOSE: To determine the risk factors for acute esophagitis (AE) in non-small-cell lung cancer (NSCLC) patients treated with concurrent chemotherapy (CCT) and three-dimensional conformal radiotherapy (3D-CRT). METHODS AND MATERIALS: Clinical data were retrospectively analyzed for 215 NSCLC patients treated with CCT and 3D-CRT during 2000-2003, 127 of whom also had induction chemotherapy (ICT). Carboplatin and paclitaxel were the most commonly used agents for both ICT and CCT. The median prescription dose of radiotherapy was 63.5 Gy in 35 fractions. AE was graded during each treatment week and 1-month follow-up visits. The factors related to clinical and disease characteristics, CCT and 3D-CRT treatments, and treatment planning were reviewed and analyzed for their association with Grade > or =3 AE using univariate and multivariate logistic tests. RESULTS: The rate of any grade AE was 93.0% and of Grade > or =3 was 20.5%. Univariate analyses showed that none of the clinical factors was significantly associated with Grade > or =3 AE. However, the mean radiation dose to the esophagus, the absolute esophageal volume treated above 15 Gy (aV15) through aV45 Gy, and the relative esophagus volume treated above 10 Gy (rV10) through rV45 Gy were significant risk factors for Grade > or =3 AE. Only rV20 was retained as the single risk factor in multivariate analyses. CONCLUSIONS: The risk of AE in the NSCLC patients treated with CCT and 3D-CRT was primarily determined by dosimetric factors. These factors should be carefully considered during treatment planning to minimize the incidence of AE.

Acute Disease↗

Beam angle optimization and reduction for intensity-modulated radiation therapy of non-small-cell lung cancers.

PURPOSE: To optimize beam angles and reduce the number of beams used for intensity-modulated radiation therapy (IMRT) of non-small-cell lung cancer (NSCLC). METHODS AND MATERIALS: An exhaustive search scheme was used to perform beam angle optimization (BAO) for IMRT of NSCLC. This approach involved intercomparison of all possible beam angle combinations and selection of the best angles based on the scores or costs of the objective functions used in the treatment plan optimization. Ten Stage III NSCLC cases were selected to evaluate the BAO algorithm and dosimetry benefits of IMRT-BAO. IMRT plans using five or seven coplanar beams were optimized and compared with those using nine equal-spaced beams. Results of BAO were also compared between plans using different numbers of beams with or without fluence modulation. RESULTS: Each anatomic structure, e.g., tumor or lung, had its own preferred beam angles. Thus, BAO required appropriate balance of competing objective functions. Plans using fewer angles (five or seven beams) could achieve plan quality similar to those using nine equal-spaced beams, however with reduced monitor units and field segments. The number of beams used for the treatment (five vs. seven) and the fluence modulation (open or IMRT beams) did not have a significant impact on the results of the BAO. CONCLUSIONS: Use of fewer beams (e.g., five) for lung IMRT could result in acceptable plan quality but improved treatment efficiency. A multiresolution search scheme could be developed for BAO using fewer and nonmodulated beams to reduce the computation cost of BAO.

Algorithms↗

Development and commissioning of a multileaf collimator model in monte carlo dose calculations for intensity-modulated radiation therapy.

A multileaf collimator (MLC) model, "MATMLC," was developed to simulate MLCs for Monte Carlo (MC) dose calculations of intensity-modulated radiation therapy (IMRT). This model describes MLCs using matrices of regions, each of which can be independently defined for its material and geometry, allowing flexibility in simulating MLCs from various manufacturers. The free parameters relevant to the dose calculations with this MLC model included MLC leaf density, interleaf air gap, and leaf geometry. To commission the MLC model and its free parameters for the Varian Millennium MLC-120 (Varian Oncology Systems, Palo Alto, CA), we used the following leaf patterns: (1) MLC-blocked fields to test the effects of leaf transmission and leakage; (2) picket-fence fields to test the effects of the interleaf air gap and tongue-groove design; and (3) abutting-gap fields to test the effects of rounded leaf ends. Transmission ratios and intensity maps for these leaf patterns were calculated with various sets of modeling parameters to determine their dosimetric effects, sensitivities, and their optimal combinations to give the closest agreement with measured results. Upon commissioning the MLC model, we computed dose distributions for clinical IMRT plans using the MC system and verified the results with those from ion chamber and thermoluminescent dosimeter measurements in water phantoms and anthropomorphic phantoms. This study showed that the MLC transmission ratios were strongly dependent on both leaf density and the interleaf air gap. The effect of interleaf air gap and tongue-groove geometry can be determined most effectively through fence-type MLC patterns. Using the commissioned MLC model, we found that the calculated dose from the MC system agreed with the measured data within clinically acceptable criteria from low- to high-dose regions, showing that the model is acceptable for clinical applications.

Humans↗

The prevalence of myocardial ischemia after concurrent chemoradiation therapy as detected by gated myocardial perfusion imaging in patients with esophageal cancer.

UNLABELLED: The detection of myocardial perfusion abnormalities after radiation therapy (RT) has been investigated previously in patients with lymphoma and breast cancer. However, the prevalence and association of such abnormalities with RT in esophageal cancer patients have not been investigated previously. METHODS: The prevalence of myocardial perfusion abnormalities detected using gated myocardial perfusion imaging (GMPI) in patients with esophageal cancer after RT (RT group) was compared with that in patients with esophageal cancer who did not undergo RT (NRT group). The patients' data were extracted from a prospectively collected database. The results of GMPI that were read by multiple readers were tested further by an expert reader who was unaware of the patients' clinical information. This reader's findings were correlated with the different RT isodose lines as seen in the CT for RT planning. Isodose lines containing the affected segments in GMPI as well as the rest of the left ventricle were recorded. Additionally, information with regard to the mean radiation dose to the heart for each patient was collected. An overall, mean radiation dose to the heart in patients with abnormal GMPI studies was compared with that in patients with normal GMPI studies. RESULTS: Fifty-one patients were included, 26 in the RT group and 25 in the NRT group. The mean and median interval between RT and GMPI was 7.5 and 3.0 mo, respectively. We identified myocardial perfusion defects in 14 patients (54%) in the RT group and in 4 patients (16%) in the NRT group. Eleven patients (42%) in the RT group had mild inferior wall ischemia versus only 1 patient (4%) in the NRT group (P = 0.001). All of the patients with inferior wall ischemia had distal esophageal cancer. The remaining 12 patients in the RT group and 21 patients in the NRT group had normal GMPI results. The mean left ventricular ejection fraction was 59.0% +/- 10.7% in the RT group and 59.3% +/- 9.8% in the NRT group (P = not significant). Good agreement was found between the GMPI results interpreted by multiple readers and those of the single expert reader (kappa = 0.84). In 7 of 10 patients (70%) who had abnormal GMPI results in the RT group, the myocardial perfusion defect was encompassed in RT isodose lines >/= 45 Gy, whereas in only 5 of 20 patients (25%) the normal left ventricle was included in the RT isodose line >/= 45 Gy. CONCLUSION: RT is associated with a high prevalence of inferior left ventricular ischemia, as detected using GMPI in patients with distal esophageal cancer. Most perfusion defects are encompassed within an isodose line >/= 45 Gy in the RT plan.

Aged↗

Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer.

BACKGROUND AND PURPOSE: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal lung than three-dimensional conformal radiotherapy (3 DCRT) in treating distal esophageal malignancies. PATIENTS AND METHODS: Ten patient cases with cancer of the distal esophagus were selected for a retrospective treatment-planning study. IMRT plans using four, seven, and nine beams (4B, 7B, and 9B) were developed for each patient and compared with the 3 DCRT plan used clinically. IMRT and 3 DCRT plans were evaluated with respect to PTV coverage and dose-volumes to irradiated normal structures, with statistical comparison made between the two types of plans using the Wilcoxon matched-pair signed-rank test. RESULTS: IMRT plans (4B, 7B, 9B) reduced total lung volume treated above 10 Gy (V(10)), 20 Gy (V(20)), mean lung dose (MLD), biological effective volume (V(eff)), and lung integral dose (P<0.05). The median absolute improvement with IMRT over 3DCRT was approximately 10% for V(10), 5% for V(20), and 2.5 Gy for MLD. IMRT improved the PTV heterogeneity (P<0.05), yet conformity was better with 7B-9B IMRT plans. No clinically meaningful differences were observed with respect to the irradiated volumes of spinal cord, heart, liver, or total body integral doses. CONCLUSIONS: Dose-volume of exposed normal lung can be reduced with IMRT, though clinical investigations are warranted to assess IMRT treatment outcome of esophagus cancers.

Dose-Response Relationship, Radiation↗

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency.

PURPOSE: To compare treatment plans for multileaf collimators (MLCs) with different leaf widths and different finite pencil beam (FPB) sizes, to determine the planning quality and delivery efficiency of segmented MLC (SMLC) delivery of intensity-modulated radiation therapy (IMRT) for malignant pleural mesothelioma (MPM). METHODS AND MATERIALS: Computerized tomography images of 10 right-side MPM patients were used for this planning study on a CORVUS treatment-planning system (NOMOS Corporation, Sewickley, PA) for a Varian Millennium 120-MLC (Varian Medical Systems, Palo Alto, CA). Three beam models were used. The first model forced two 0.5-cm MLC leaves to move in tandem to simulate a 1-cm leaf-width MLC and a FPB size of 1 x 1 cm2. The second model used 0.5-cm leaves with a FPB size of 0.5 x 1 cm2 (1 cm in the direction of leaf movement). The third model used 0.5-cm leaves, with a FPB size of 0.5 x 0.5 cm2. For optimization, the same dose constraints and beam parameters were used for each data set. Tissue heterogeneity corrections were used during optimization and dose calculation. Plans were optimized such that the clinical target volume received 50 Gy in 25 fractions. Dose distributions to the target and normal structures were evaluated. The number of monitor units, the number of segments, and delivery times were used to evaluate delivery efficiency. RESULTS: All three beam models could be used for IMRT planning for MPM. The doses to clinical target volume, spinal cord, lung, liver, heart, and contralateral kidney were acceptable with all three beam models. The 0.5 x 0.5-cm2 beam model used the most monitor units (6883 +/- 974 vs. 3332 +/- 406 and 3407 +/- 443 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively) and treated the most segments (4297 +/- 802 vs. 1357 +/- 156 and 1767 +/- 212 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively). The plan generated with the 1 x 1-cm2 model required the least amount of time to deliver. CONCLUSIONS: The quality of the MPM IMRT plans generated with the three beam models presented here was similar; however, the 1 x 1-cm2 model provided the most efficient delivery of MPM IMRT with the CORVUS planning system.

Aged↗

Interactively exploring optimized treatment plans.

PURPOSE: A new paradigm for treatment planning is proposed that embodies the concept of interactively exploring the space of optimized plans. In this approach, treatment planning ignores the details of individual plans and instead presents the physician with clinical summaries of sets of solutions to well-defined clinical goals in which every solution has been optimized in advance by computer algorithms. METHODS AND MATERIALS: Before interactive planning, sets of optimized plans are created for a variety of treatment delivery options and critical structure dose-volume constraints. Then, the dose-volume parameters of the optimized plans are fit to linear functions. These linear functions are used to show in real time how the target dose-volume histogram (DVH) changes as the DVHs of the critical structures are changed interactively. A bitmap of the space of optimized plans is used to restrict the feasible solutions. The physician selects the critical structure dose-volume constraints that give the desired dose to the planning target volume (PTV) and then those constraints are used to create the corresponding optimized plan. RESULTS: The method is demonstrated using prototype software, Treatment Plan Explorer (TPEx), and a clinical example of a patient with a tumor in the right lung. For this example, the delivery options included 4 open beams, 12 open beams, 4 wedged beams, and 12 wedged beams. Beam directions and relative weights were optimized for a range of critical structure dose-volume constraints for the lungs and esophagus. Cord dose was restricted to 45 Gy. Using the interactive interface, the physician explored how the tumor dose changed as critical structure dose-volume constraints were tightened or relaxed and selected the best compromise for each delivery option. The corresponding treatment plans were calculated and compared with the linear parameterization presented to the physician in TPEx. The linear fits were best for the maximum PTV dose and worst for the minimum PTV dose. Based on the root-mean-square error between the fit values and their corresponding data values, the linear fit appears to be adequate, although higher order polynomials could give better results. Some of the variance in fit is due to the stochastic nature of the simulated annealing optimization algorithm, which does not reproduce the exact same results in repetitions of the same calculation. Using a directed search algorithm for plan optimization should produce better parameter fits and, therefore, better predictions of plan characteristics by TPEx. CONCLUSIONS: Using TPEx, the physician can easily select the optimum plan for a patient, with no imposed arbitrary definition of the "best" plan. More importantly, the physician can readily see what can be achieved for the patient with a given delivery technique. There is no more uncertainty about whether or not a better plan exists. By comparing the "best" plans for different delivery options (e.g., three-dimensional conformal radiotherapy versus intensity-modulated radiation therapy), the physician can gauge the clinical benefits of greater technical complexity. However, before the TPEx process can be clinical useful, faster computers and/or algorithms are needed and more studies are needed to better model the spaces of optimized solutions.

Algorithms↗

Intensity modulated radiation therapy and proton radiotherapy for non-small cell lung cancer.

Local failure of non-small-cell lung cancer (NSCLC) radiotherapy may cause continuous tumor seeding and death. Radiotherapy dose escalation has been shown to improve local control and survival. However, the toxicities associated with dose escalation are significant and limit the potential of dose escalation. Intensity modulated radiotherapy (IMRT) may have the potential to improve the therapeutic ratio for photon treatment of lung cancer by sparing surrounding normal tissues. However, low-dose exposure to normal lung and organ motion is a major concern. We have conducted several studies to address these issues and started clinical studies to evaluate the potential benefit of IMRT in patients with NSCLC. Proton radiotherapy may have greater potential to spare normal tissue and allow for further dose escalation and acceleration. We are conducting preclinical and clinical studies for imaging-guided proton radiotherapy in NSCLC. In this paper, we discuss the preliminary data, IMRT treatment guidelines, and ongoing studies for proton therapy in NSCLC.

Carcinoma, Non-Small-Cell Lung↗

Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators.

The current study presents the reference photon dosimetry data (RPDD) and reference phase space data (RPSD) for the 6 MV photon beam from Varian 2100 series linear accelerators. The RPDD provide the basic photon dosimetry data, typically collected during the initial commissioning of a new linear accelerator, including output factors, depth dose data, and beam profile data in air and in water. The RPSD provide the full phase space information, such as position, direction, and energy for each particle generated inside the head of any particular linear accelerator in question. The dosimetric characteristics if the 6 MV photon beam from the majority of the aforementioned accelerators, which are unaltered from the manufacturer's original specifications, can be fully described with these two data sets within a clinically acceptable uncertainty (approximately +/-2 %). The current study also presents a detailed procedure to establish the RPDD and RPSD using measured data and Monte Carlo calculations. The RPDD were constructed by compiling our own measured data and the average data based on the analysis of more than 50 sets of measured data from the Radiological Physics Center (RPC) and 10 sets of clinical dosimetry data obtained from 10 different institutions participating in the RPC's quality assurance monitoring program. All the measured data from the RPC and the RPC-monitored institutions were found to be within a statistically tight range (i.e., 1sigma approximately 1% or less) for each dosimetric quantity. The manufacturer's standard data, except for in-air off-axis factors that are available only from the current study, were compared with the RPDD, showing that the manufacturer's standard data could also be used as the RPDD for the photon beam studied in this study. The RPSD were obtained from Monte Carlo calculations using the BEAMnrc/ DOSXYZnrc code system with 6.2 MeV (a spread of 3% full width at half maximum) and 1.0 mm full width at half maximum as the values of the energy and radial spread of a Gaussian electron pencil beam incident on the target, respectively. The RPSD were capable of generating Monte Carlo data that agreed with the RPDD within the acceptance criteria adopted in the current study (e.g., 1% or 1 mm for depth dose). A complete set of the RPDD and RPSD from the current study is available from the RPC website (http://rpc.mdanderson.org) or via mass storage media such as DVD or CD-ROM upon request.

Electrons↗

Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.

Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory.

Computer Simulation↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part II-margin reduction of internal target volume.

PURPOSE: To analyze the relationship between lung motion and skin surface motion during respiration, determine the uncertainties and variability of such a relationship, and assess the potential of reducing internal target margin for gated radiotherapy. METHODS AND MATERIALS: Three healthy volunteers and four lung cancer patients were recruited in a prospective imaging study using MRI to track the internal lung and external skin motion during breathing. The relationship between the lung and skin motion was modeled using linear regression analysis. The slope of the linear fit and its confidence interval were analyzed for different lung locations, skin surface locations, and breathing patterns from separate imaging sessions. The margins of the internal target volume were calculated based on the residual lung motion during gating and its uncertainties from multiple treatment fractions for the gated treatment. RESULTS: The slope and confidence interval of the linear regression from the motion analysis were uniquely defined by the locations of the lung, skin surface, and breathing patterns. Statistically significant differences were observed among individuals and between different times of measurement. The normal free-breathing motion averaged from all volunteer and patient data was 13.4 +/- 7.4 mm along the superior-inferior (SI) direction and 6.9 +/- 2.6 mm along the anterior-posterior (AP) direction. With simulated respiratory gating, the average margin reduction was 5.5 +/- 4.8 mm and 1.6 +/- 1.0 mm, respectively, along the SI and AP directions (or 36% +/- 15% and 25% +/- 14%, respectively, relative to free-breathing motion). CONCLUSION: Because respiratory movement is rather complex, the relationship between the lung and skin surface motion is affected by many anatomic and physiologic factors. The reduction of internal target margin and efficacy of the free-breathing gating technique should be assessed for individual cases.

Adult↗

Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion.

PURPOSE: To measure the internal lung motion due to respiration using magnetic resonance images (MRIs); to evaluate the correlation between lung motion and skin surface motion and the reliability of tracking lung motion with external fiducials. METHODS AND MATERIALS: An MRI protocol using fast gradient-echo sequences was developed to acquire dynamic cine images of the thoracoabdominal region along the axial, sagittal, and coronal planes. The subjects (3 healthy volunteers and 4 lung cancer patients) were instructed to perform normal or altered breathing during MRI. Lung vessels identified on MRI were used as anatomic landmarks for internal lung structures. From sagittal cine MRI scans, the positions of the lung vessels and skin surface were tracked and their movements measured. Correlation between the movements of the external markers and internal structures was then calculated and analyzed. RESULTS: Lung vessel motion in the superior-inferior (SI) direction correlated best with mid-upper abdominal skin surface movement (correlation coefficient, 0.89 +/- 0.09 and 0.87 +/- 0.23 for volunteers and patients, respectively). The anterior-posterior (AP) vessel motion generally correlated poorly with the skin surface movement, with marker placement on the upper chest yielding the strongest results (correlation coefficient, 0.72 +/- 0.23 and 0.44 +/- 0.27 for volunteers and patients, respectively). The strength of the correlation depended on the locations of the tracked vessels, locations of the skin surface, and subjects' breathing patterns. The best correlation was seen between the motion of an abdominal fiducial and SI lung motion. Significant intersubject variability was also observed. CONCLUSION: Movement of an external fiducial may not correlate fully with, or predict, internal lung motion. Effective monitoring of respiration may have to rely on a combination of multiple fiducials and other physiologic parameters, such as lung volume and/or air flow.

Adult↗

Comparison of rectal dose-wall histogram versus dose-volume histogram for modeling the incidence of late rectal bleeding after radiotherapy.

PURPOSE: To compare the fits of normal-tissue complication probability (NTCP) models based on rectal dose-wall histograms (DWHs) vs. dose-volume histograms (DVHs) when the two are used to analyze a common set of late rectal toxicity data. METHODS AND MATERIALS: Data were analyzed from 128 prostate cancer patients treated with 3-dimensional conformal radiotherapy (3D-CRT) at The University of Texas M.D. Anderson Cancer Center (UTMDACC). The DVH for total rectal volume, including contents, was obtained for each patient from the treatment-planning system. A DWH was also computed, using the outer rectal contour plus an autogenerated inner contour that corresponds to an assumed 3-mm rectal wall thickness. The endpoint for analysis was Grade 2 or higher late rectal bleeding within 2 years of treatment; all patients had at least 2 years of follow-up. Four different NTCP models were fitted to the response data by using either the DVH or the DWH to describe the dose distribution to rectum or rectal wall, respectively. The 4 models considered were the Lyman model, the mean dose model, the parallel-architecture model, and a model based on the volume of a organ receiving more than a specified dose (the "cutoff-dose" model). RESULTS: For each of the models, the fit to the late rectal bleeding data was slightly improved when the analysis was based on the rectal DWH instead of on the DVH. In addition, the results of the cutoff dose and parallel architecture models were consistent with one another for the DWH data but not for the DVH data. For the DWH data, both models predict a 50% or higher incidence of Grade 2 or worse late rectal bleeding within 2 years if 80% or more of the rectal wall is exposed to doses greater than 32 Gy. A 50% or higher incidence of rectal bleeding is also predicted if the mean dose to rectal wall exceeds 53.2 Gy. CONCLUSIONS: A consistent, although modest, improvement occurs in the fits of NTCP models to the UTMDACC 2-year late rectal bleeding data when the fit is based on the rectal dose-wall histogram instead of on the dose-volume histogram for entire rectum, including contents.

Confidence Intervals↗

Cluster models of dose-volume effects.

PURPOSE: Describe cluster models, normal-tissue complication probability models in which both the number and the spatial location of radiation-sterilized functional subunits play a role in defining complication probability. METHODS AND MATERIALS: Computer simulation was used to determine the maximum size cluster of sterilized subunits associated with a given dose distribution. Complications were associated with large clusters. RESULTS: Cluster models showed a volume effect, as increasing effect for constant dose when the volume increased or constant effect when the dose was reduced with increasing volume. Cluster models gave similar results to existing models when tissues were irradiated uniformly. With inhomogeneous dose distributions, on the other hand, different spatial distributions of "hot spots" may lead to different predictions of complication probability by cluster models. The result was that a higher complication probability resulted when hot spots were contiguous (clustered) than when they were dispersed, even if both situations are characterized by the same dose-volume histogram. A potential advantage of cluster models is to provide an easy, internally consistent way to predict complications arising from the inhomogeneous dose distributions that sometimes arise with intensity-modulated radiotherapy. CONCLUSION: Cluster models offer a new way to quantify complication probability in treatment situations in which a wide variety of hot-spot distributions occur.

Animals↗

Dose-volume response analyses of late rectal bleeding after radiotherapy for prostate cancer.

PURPOSE: To compare the fits of various normal tissue complication probability (NTCP) models to a common set of late rectal toxicity data, with the aim of identifying the best model for predicting late rectal injury after irradiation. METHODS AND MATERIALS: Late toxicity data from 128 prostate cancer patients treated on protocol with three-dimensional conformal radiotherapy at The University of Texas M.D. Anderson Cancer Center (UTMDACC) were analyzed. The dose-volume histogram for total rectal volume, including contents, was obtained for each patient, and the presence or absence of Grade 2 or worse rectal bleeding within 2 years of treatment was scored. Five different NTCP models were fitted to the data using maximum likelihood analysis: the Lyman model, the mean dose model, a parallel architecture model, and models based on either a cutoff dose or a cutoff volume. RESULTS: All five of the NTCP models considered provided very similar fits to the UTMDACC rectal bleeding data. In particular, none of the more highly parameterized models (the four-parameter parallel model, three-parameter Lyman model, or three-parameter cutoff dose and volume models) provided a better fit than the simplest of the models, the two-parameter NTCP model describing rectal bleeding as a probit function of mean dose to rectum. CONCLUSION: No dose-volume response model has yet been identified that provides a better description of the UTMDACC rectal toxicity data than the mean dose model. Because this model has relatively low predictive accuracy, the need to identify a better model remains.

Dose-Response Relationship, Radiation↗

Feasibility of sparing lung and other thoracic structures with intensity-modulated radiotherapy for non-small-cell lung cancer.

PURPOSE: To investigate the possibility of using intensity-modulated radiotherapy (IMRT) to reduce the irradiated volumes of the normal lung and other critical structures in the treatment of non-small-cell lung cancer (NSCLC) and to investigate the effect of IMRT on the potential of spreading low doses to large volumes of normal tissues in such treatment. METHODS AND MATERIALS: A retrospective treatment planning study was performed to compare IMRT and conventional three-dimensional conformal radiation therapy (3D-CRT) for 10 NSCLC patients (Stage I-IIIB). In the IMRT plans, three to nine coplanar beams were designed to treat 95% of the planning target volume with 63 Gy and to minimize the volumes of the normal lung, esophagus, heart, and spinal cord irradiated above their tolerance doses. The two types of plans were compared with respect to the planning target volume coverage, dose-volume histograms, and other dosimetric indexes of the normal structures. RESULTS: Comparing the nine-beam IMRT plan with the 3D-CRT plan, the percentage of lung volume that received >20 Gy and the mean lung dose were reduced for all cases, with a median reduction of 8% and 2 Gy, respectively. An additional reduction of the >5-Gy volume and >10-Gy volume for the lung and thoracic tissue was more difficult with IMRT, although still possible using fewer beams in IMRT. The integral dose to the entire thorax was equivalent and even reduced for 8 of 10 cases using IMRT. CONCLUSION: It is possible to reduce the volumes of low doses (such as the >10-Gy volume and >20-Gy volume) for thoracic normal tissues using IMRT. The increased integral dose and low-dose volumes can be avoided for IMRT if such concerns are addressed carefully in the inverse planning process and with optimization of the IMRT beam configuration.

Carcinoma, Non-Small-Cell Lung↗